-
Swirling and snaking, 3D oscillatory bifurcations of vesicle dynamics in microcirculation
Authors:
**ming Lyu,
Paul G. Chen,
Alexander Farutin,
Marc Jaeger,
Chaouqi Misbah,
and Marc Leonetti
Abstract:
Vesicles are soft elastic bodies with distinctive mechanical properties such as bending resistance, membrane fluidity, and their strong ability to deform, mimicking some properties of biological cells. While previous three-dimensional (3D) studies have identified stationary shapes such as slipper and axisymmetric ones, we report a complete phase diagram of 3D vesicle dynamics in a bounded Poiseuil…
▽ More
Vesicles are soft elastic bodies with distinctive mechanical properties such as bending resistance, membrane fluidity, and their strong ability to deform, mimicking some properties of biological cells. While previous three-dimensional (3D) studies have identified stationary shapes such as slipper and axisymmetric ones, we report a complete phase diagram of 3D vesicle dynamics in a bounded Poiseuille flow with two more oscillatory dynamics, 3D snaking and swirling. 3D snaking is characterized by planar oscillatory motion of the mass center and shape deformations, which is unstable and leads to swirling or slipper. Swirling emerges from supercritical pitchfork bifurcation. The mass center moves along a helix, the preserved shape rolls on itself and spins around the flow direction. Swirling can coexist with slipper.
△ Less
Submitted 16 June, 2021;
originally announced June 2021.
-
Effect of pulse width on the dynamics of a deflated vesicle in unipolar and bipolar pulsed electric fields
Authors:
Sudip Das,
Marc Jaeger,
Marc Leonetti,
Rochish M. Thaokar,
Paul G. Chen
Abstract:
Giant unilamellar vesicles subjected to pulsed direct-current (pulsed-DC) fields are promising biomimetic systems to investigate the electroporation of cells. In strong electric fields, vesicles undergo significant deformation, which strongly alters the transmembrane potential, consequently the electroporation. Previous theoretical studies investigated the electrodeformation of vesicles in DC fiel…
▽ More
Giant unilamellar vesicles subjected to pulsed direct-current (pulsed-DC) fields are promising biomimetic systems to investigate the electroporation of cells. In strong electric fields, vesicles undergo significant deformation, which strongly alters the transmembrane potential, consequently the electroporation. Previous theoretical studies investigated the electrodeformation of vesicles in DC fields (which are not pulsed). In this work, we computationally investigate the deformation of a deflated vesicle under unipolar, bipolar, and two-step unipolar pulses and show sensitive dependence of intermediate shapes on type of pulse and the pulse width. Starting with the stress-free initial shape of a deflated vesicle, which is similar to a prolate spheroid, the analysis is presented for the cases with higher and lower conductivities of the inner fluid medium relative to the outer fluid medium. For the ratio of inner to outer fluid conductivity, $σ_\mathrm{r}$ = 10, the shape always remains prolate, including when the field is turned off. For $σ_\mathrm{r} = 0.1$, several complex dynamics are observed, such as the prolate-to-oblate (PO), prolate-to-oblate-to-prolate (POP) shape transitions in time depending upon the strength of the field and the pulse properties. In this case, on turning off the field, a metastable oblate equilibrium shape is seen, that seems to be a characteristics of a deflated vesicle leading to POPO transitions. When a two-step unipolar pulse (a combination of a strong and a weak subpulse) is applied, a vesicle can reach an oblate or a prolate final shape depending upon the relative durations of the two subpulses.
△ Less
Submitted 30 July, 2021; v1 submitted 3 December, 2020;
originally announced December 2020.
-
Shape transition and hydrodynamics of vesicles in tube flow
Authors:
Paul G. Chen,
J. M. Lyu,
M. Jaeger,
M. Leonetti
Abstract:
The steady motion and deformation of a lipid-bilayer vesicle translating through a circular tube in low Reynolds number pressure-driven flow are investigated numerically using an axisymmetric boundary element method. This fluid-structure interaction problem is determined by three dimensionless parameters: reduced volume (a measure of the vesicle asphericity), geometric confinement (the ratio of th…
▽ More
The steady motion and deformation of a lipid-bilayer vesicle translating through a circular tube in low Reynolds number pressure-driven flow are investigated numerically using an axisymmetric boundary element method. This fluid-structure interaction problem is determined by three dimensionless parameters: reduced volume (a measure of the vesicle asphericity), geometric confinement (the ratio of the vesicle effective radius to the tube radius), and capillary number (the ratio of viscous to bending forces). The physical constraints of a vesicle -- fixed surface area and enclosed volume when it is confined in a tube -- determine critical confinement beyond which it cannot pass through without rupturing its membrane. The simulated results are presented in a wide range of reduced volumes [0.6, 0.98] for different degrees of confinement; the reduced volume of 0.6 mimics red blood cells. We draw a phase diagram of vesicle shapes and propose a shape transition line separating the parachute-like shape region from the bullet-like one in the reduced volume versus confinement phase space. We show that the shape transition marks a change in the behavior of vesicle mobility, especially for highly deflated vesicles. Most importantly, high-resolution simulations make it possible for us to examine the hydrodynamic interaction between the wall boundary and the vesicle surface at conditions of very high confinement, thus providing the limiting behavior of several quantities of interest, such as the thickness of lubrication film, vesicle mobility and its length, and the extra pressure drop due to the presence of the vesicle. This extra pressure drop holds implications for the rheology of dilute vesicle suspensions. Furthermore, we present various correlations and discuss a number of practical applications.
△ Less
Submitted 12 March, 2020; v1 submitted 14 December, 2019;
originally announced December 2019.