Selective temperature sensing in nanodiamonds using dressed states
Authors:
Nathaniel M Beaver,
Paul Stevenson
Abstract:
Temperature sensing at the nanoscale is a significant experimental challenge. Here, we report an approach using dressed states to make a leading quantum sensor (the nitrogen vacancy (NV) center in diamond) selectively sensitive to temperature, even in the presence of normally-confounding magnetic fields. Using an experimentally straightforward approach, we are able to suppress the magnetic sensiti…
▽ More
Temperature sensing at the nanoscale is a significant experimental challenge. Here, we report an approach using dressed states to make a leading quantum sensor (the nitrogen vacancy (NV) center in diamond) selectively sensitive to temperature, even in the presence of normally-confounding magnetic fields. Using an experimentally straightforward approach, we are able to suppress the magnetic sensitivity of the NV center by a factor of seven while retaining full temperature sensitivity and narrowing the NV center linewidth. These results demonstrate the power of engineering the sensor Hamiltonian using external control fields to enable sensing with improved specificity to target signals.
△ Less
Submitted 6 June, 2024;
originally announced June 2024.
Optimizing Off-Axis Fields for Two-Axis Magnetometry with Point Defects
Authors:
N. M. Beaver,
N. Voce,
P. Meisenheimer,
R. Ramesh,
P. Stevenson
Abstract:
Vector magnetometry is an essential tool in characterizing the distribution of currents and magnetization in a broad range of systems. Point defect sensors, like the nitrogen vacancy (NV) center in diamond, have demonstrated impressive sensitivity and spatial resolution for detecting these fields. Measuring the vector field at a single point in space using single defects, however, remains an outst…
▽ More
Vector magnetometry is an essential tool in characterizing the distribution of currents and magnetization in a broad range of systems. Point defect sensors, like the nitrogen vacancy (NV) center in diamond, have demonstrated impressive sensitivity and spatial resolution for detecting these fields. Measuring the vector field at a single point in space using single defects, however, remains an outstanding challenge. We demonstrate that careful optimization of the static bias field can enable simultaneous measurement of multiple magnetic field components with enhanced sensitivity by leveraging the nonlinear Zeeman shift from transverse magnetic fields. This work quantifies the trade-off between the increased frequency shift from second-order Zeeman effects with decreasing contrast as off-axis field components increase, demonstrating the measurement of multiple components of the magnetic field from an exemplar antiferromagnet with a complex magnetic texture.
△ Less
Submitted 7 June, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.