-
FINER: Far-Infrared Nebular Emission Receiver for the Large Millimeter Telescope
Authors:
Yoichi Tamura,
Takeshi Sakai,
Ryohei Kawabe,
Takafumi Kojima,
Akio Taniguchi,
Tatsuya Takekoshi,
Haoran Kang,
Wenlei Shan,
Masato Hagimoto,
Norika Okauchi,
Airi Tetsuka,
Akio K. Inoue,
Kotaro Kohno,
Kunihiko Tanaka,
Tom J. L. C. Bakx,
Yoshinobu Fudamoto,
Kazuyuki Fujita,
Yuichi Harikane,
Takuya Hashimoto,
Bunyo Hatsukade,
David H. Hughes,
Takahiro Iino,
Yuki Kimura,
Hiroyuki Maezawa,
Yuichi Matsuda
, et al. (12 additional authors not shown)
Abstract:
Unveiling the emergence and prevalence of massive/bright galaxies during the epoch of reionization and beyond, within the first 600 million years of the Universe, stands as a pivotal pursuit in astronomy. Remarkable progress has been made by JWST in identifying an immense population of bright galaxies, which hints at exceptionally efficient galaxy assembly processes. However, the underlying physic…
▽ More
Unveiling the emergence and prevalence of massive/bright galaxies during the epoch of reionization and beyond, within the first 600 million years of the Universe, stands as a pivotal pursuit in astronomy. Remarkable progress has been made by JWST in identifying an immense population of bright galaxies, which hints at exceptionally efficient galaxy assembly processes. However, the underlying physical mechanisms propelling their rapid growth remain unclear. With this in mind, millimeter and submillimeter-wave spectroscopic observations of redshifted far-infrared spectral lines, particularly the [O III] 88 micron and [C II] 158 micron lines, offers a crucial pathway to address this fundamental query.
To this end, we develop a dual-polarization sideband-separating superconductor-insulator-superconductor (SIS) mixer receiver, FINER, for the Large Millimeter Telescope (LMT) situated in Mexico. Harnessing advancements from ALMA's wideband sensitivity upgrade (WSU) technology, FINER covers radio frequencies spanning 120-360 GHz, delivering an instantaneous intermediate frequency (IF) of 3-21 GHz per sideband per polarization, which is followed by a set of 10.24 GHz-wide digital spectrometers. At 40% of ALMA's light-collecting area, the LMT's similar atmospheric transmittance and FINER's 5 times wider bandwidth compared to ALMA culminate in an unparalleled spectral scanning capability in the northern hemisphere, paving the way for finer spectral-resolution detection of distant galaxies.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
Large-Scale Map** Observations of DCN and DCO$^+$ toward Orion KL
Authors:
Kotomi Taniguchi,
Prathap Rayalacheruvu,
Teppei Yonetsu,
Tatsuya Takekoshi,
Bunyo Hatsukade,
Kotaro Kohno,
Tai Oshima,
Yoichi Tamura,
Yuki Yoshimura,
Víctor Gómez-Rivera,
Sergio Rojas-García,
Arturo I. Gómez-Ruiz,
David H. Hughes,
F. Peter Schloerb,
Liton Majumdar,
Masao Saito,
Ryohei Kawabe
Abstract:
We present emission maps (1.5'$\times$1.5' scale, corresponding to 0.18 pc) of the DCN ($J=2-1$) and DCO$^+$ ($J=2-1$) lines in the 2 mm band toward the Orion KL region obtained with the 2 mm receiver system named B4R installed on the Large Millimeter Telescope (LMT). The DCN emission shows a peak at the Orion KL hot core position, whereas no DCO$^+$ emission has been detected there. The DCO$^+$ e…
▽ More
We present emission maps (1.5'$\times$1.5' scale, corresponding to 0.18 pc) of the DCN ($J=2-1$) and DCO$^+$ ($J=2-1$) lines in the 2 mm band toward the Orion KL region obtained with the 2 mm receiver system named B4R installed on the Large Millimeter Telescope (LMT). The DCN emission shows a peak at the Orion KL hot core position, whereas no DCO$^+$ emission has been detected there. The DCO$^+$ emission shows enhancement at the west side of the hot core, which is well shielded from the UV radiation from OB massive stars in the Trapezium cluster. We have derived the abundance ratio of DCN/DCO$^+$ at three representative positions where both species have been detected. The gas components with $V_{\rm {LSR}} \approx 7.5-8.7$ km/s are associated with low abundance ratios of $\sim4-6$, whereas much higher abundance ratios ($\sim22-30$) are derived for the gas components with $V_{\rm {LSR}} \approx 9.2-11.6$ km/s. We have compared the observed abundance ratio to our chemical models and found that the observed differences in the DCN/DCO$^+$ abundance ratios are explained by different densities.
△ Less
Submitted 11 January, 2024;
originally announced January 2024.
-
Observational demonstration of a low-cost fast Fourier transform spectrometer with a delay-line-based ramp-compare ADC implemented on FPGA
Authors:
Atsushi Nishimura,
Takeru Matsumoto,
Teppei Yonetsu,
Yuka Nakao,
Shinji Fujita,
Hiroyuki Maezawa,
Toshikazu Onishi,
Hideo Ogawa
Abstract:
In this study, a novel type of Fourier transform radio spectrometer (termed as all-digital radio spectrometer; ADRS) has been developed in which all functionalities comprising a radio spectrometer including a sampler and Fourier computing unit were implemented as a soft-core on a field-programmable gate array (FPGA). A delay-line-based ramp-compare analog-to-digital converter (ADC), one of complet…
▽ More
In this study, a novel type of Fourier transform radio spectrometer (termed as all-digital radio spectrometer; ADRS) has been developed in which all functionalities comprising a radio spectrometer including a sampler and Fourier computing unit were implemented as a soft-core on a field-programmable gate array (FPGA). A delay-line-based ramp-compare analog-to-digital converter (ADC), one of completely digital ADC, was used, and two primary elements of the ADC, an analog-to-time converter (ATC) and a time-to-digital converter (TDC), were implemented on the FPGA. The sampling rate of the ADRS $f$ and the quantization bit rate $n$ are limited by the relation, $τ= \frac{1}{2^{n}f}$, where $τ$ is the latency of the delay element of the delay-line. Given that the typical latency of the delay element implemented on FPGAs is $\sim10$ ps, adoption of a low quantization bit rate, which satisfies the requirements for radio astronomy, facilitates the realization of a high sampling rate up to $\sim$100 GSa/s. In addition, as the proposed \ADRS does not require a discrete ADC and can be implemented on mass-produced evaluation boards, its fabrication cost is much lower than that of conventional spectrometers. The ADRS prototype was fabricated with values of $f$ = 600 MSa/s and $n$ = 6.6 using a PYNQ-Z1 evaluation board, with a $τ$ of 16.7 ps. The performance of the prototype, including its linearity and stability, was measured, and a test observation was conducted using the Osaka Prefecture University 1.85-m mm-submm telescope; this confirmed the potential application of the prototype in authentic radio observations. With 10 times better cost performance ($\sim$800 USD GHz$^{-1}$) than conventional radio spectrometers, the prototype facilitates cost-effective coverage of intermediate frequency (IF) bandwidths of $\sim100$ GHz in modern receiver systems.
△ Less
Submitted 1 April, 2021;
originally announced April 2021.