-
XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad,
J. J. Cuenca-García,
V. D'Andrea
, et al. (139 additional authors not shown)
Abstract:
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 t…
▽ More
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
The XENONnT Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
M. Balata,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui
, et al. (170 additional authors not shown)
Abstract:
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in…
▽ More
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Scaling slowly rotating asteroids by stellar occultations
Authors:
A. Marciniak,
J. Ďurech,
A. Choukroun,
J. Hanuš,
W. Ogłoza,
R. Szakáts,
L. Molnár,
A. Pál,
F. Monteiro,
E. Frappa,
W. Beisker,
H. Pavlov,
J. Moore,
R. Adomavičienė,
R. Aikawa,
S. Andersson,
P. Antonini,
Y. Argentin,
A. Asai,
P. Assoignon,
J. Barton,
P. Baruffetti,
K. L. Bath,
R. Behrend,
L. Benedyktowicz
, et al. (154 additional authors not shown)
Abstract:
As evidenced by recent survey results, majority of asteroids are slow rotators (P>12 h), but lack spin and shape models due to selection bias. This bias is skewing our overall understanding of the spins, shapes, and sizes of asteroids, as well as of their other properties. Also, diameter determinations for large (>60km) and medium-sized asteroids (between 30 and 60 km) often vary by over 30% for m…
▽ More
As evidenced by recent survey results, majority of asteroids are slow rotators (P>12 h), but lack spin and shape models due to selection bias. This bias is skewing our overall understanding of the spins, shapes, and sizes of asteroids, as well as of their other properties. Also, diameter determinations for large (>60km) and medium-sized asteroids (between 30 and 60 km) often vary by over 30% for multiple reasons.
Our long-term project is focused on a few tens of slow rotators with periods of up to 60 hours. We aim to obtain their full light curves and reconstruct their spins and shapes. We also precisely scale the models, typically with an accuracy of a few percent.
We used wide sets of dense light curves for spin and shape reconstructions via light-curve inversion. Precisely scaling them with thermal data was not possible here because of poor infrared data: large bodies are too bright for WISE mission. Therefore, we recently launched a campaign among stellar occultation observers, to scale these models and to verify the shape solutions, often allowing us to break the mirror pole ambiguity.
The presented scheme resulted in shape models for 16 slow rotators, most of them for the first time. Fitting them to stellar occultations resolved previous inconsistencies in size determinations. For around half of the targets, this fitting also allowed us to identify a clearly preferred pole solution, thus removing the ambiguity inherent to light-curve inversion. We also address the influence of the uncertainty of the shape models on the derived diameters.
Overall, our project has already provided reliable models for around 50 slow rotators. Such well-determined and scaled asteroid shapes will, e.g. constitute a solid basis for density determinations when coupled with mass information. Spin and shape models continue to fill the gaps caused by various biases.
△ Less
Submitted 13 October, 2023;
originally announced October 2023.
-
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai
, et al. (141 additional authors not shown)
Abstract:
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid targe…
▽ More
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid target were reduced to unprecedentedly low levels, giving an electronic recoil background rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ in the region of interest. A blind analysis of nuclear recoil events with energies between $3.3$ keV and $60.5$ keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ for a WIMP mass of $28~\mathrm{GeV}/c^2$ at $90\%$ confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.
△ Less
Submitted 5 August, 2023; v1 submitted 26 March, 2023;
originally announced March 2023.
-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Starspots, chromospheric emission lines, and flares of zero-age main-sequence stars
Authors:
Mai Yamashita,
Yoichi Itoh,
Yumiko Oasa
Abstract:
Zero-age main-sequence (ZAMS) stars are considered to have enormous starspots and show strong chromospheric emission lines because of their strong surface magnetic field. We discuss the dynamo activities of ZAMS stars with respect to their periodic light variation caused by a starspot and with respect to the strength of the chromospheric emission lines. The light curves of $33$ ZAMS stars in IC 23…
▽ More
Zero-age main-sequence (ZAMS) stars are considered to have enormous starspots and show strong chromospheric emission lines because of their strong surface magnetic field. We discuss the dynamo activities of ZAMS stars with respect to their periodic light variation caused by a starspot and with respect to the strength of the chromospheric emission lines. The light curves of $33$ ZAMS stars in IC 2391 and IC 2602 were obtained from \textit{TESS} photometric data. The light curves can be grouped into the following four categories: single frequency, possible shape changer, beater, and complex variability. The amplitudes of the light curves are $0.001-0.145\,\mathrm{mag}$, similar to those of ZAMS stars in Pleiades. The starspot coverages are $0.1-21\%$. We found that the light variations and Ca\,\emissiontype{II} emission line strength of ZAMS stars in IC 2391, IC 2602, and the Pleiades cluster are as large as those of the most active superflare stars and two orders larger than those of the Sun, and are located on the extensions of the superflare stars. These results suggest that superflare stars link the properties of the Sun to those of the ZAMS stars of ages between $30$ and $120\,\mathrm{Myr}$. ZAMS stars with a single frequency or possible shape change in the light curve tend to have both large light variation, indicating large spot coverage, and saturated Ca\,\emissiontype{II} emission line strength. ZAMS stars with beat or complex variability have small spot coverage and a faint Ca\,\emissiontype{II} emission line. We also detected $21$ flares in the \textit{TESS} light curves of $12$ ZAMS stars in IC 2391 and IC 2602, where most of these stars have saturated chromospheric Ca\,\emissiontype{II} emission lines. The energies of the flares are estimated to be $\sim 10^{33}-10^{35}\,\mathrm{erg}$, which is comparable with the energy of a superflare.
△ Less
Submitted 11 August, 2022; v1 submitted 10 August, 2022;
originally announced August 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Measurements of Chromospheric Mg I Emission Lines of Zero-Age Main-Sequence Stars
Authors:
Mai Yamashita,
Yoichi Itoh
Abstract:
The chromosphere is the active atmosphere in which energetic eruption events, such as flares, occur. Chromospheric activity is driven by the magnetic field generated by stellar rotation and convection. The relationship between chromospheric activity and the Rossby number, the ratio of the rotational period to the convective turnover time, has been extensively examined for many types of stars, by u…
▽ More
The chromosphere is the active atmosphere in which energetic eruption events, such as flares, occur. Chromospheric activity is driven by the magnetic field generated by stellar rotation and convection. The relationship between chromospheric activity and the Rossby number, the ratio of the rotational period to the convective turnover time, has been extensively examined for many types of stars, by using narrow chromospheric emission lines, such as the Ca II lines and the Mg II h and k lines. However, the stars with small Rossby numbers, i.e., stars with rapid rotations and/or long convective turnover times, show constant strengths of such lines against the Rossby number. In this study, we investigate the infrared Mg I emission lines at 8807 A of 47 zero-age main-sequence (ZAMS) stars in IC 2391 and IC 2602 using the archive data of the Anglo-Australian Telescope at the University College London Echelle Spectrograph. After subtracting the photospheric absorption component, the Mg I line is detected as an emission line for 45 ZAMS stars, whose equivalent widths are between 0.02 A and 0.52 A. A total of 42 ZAMS stars show the narrower Mg I emission lines instead of the Ca II infrared triplet emission lines, suggesting that they are formed at different depths. The ZAMS stars with smaller Rossby numbers show stronger Mg I emission lines. The Mg I emission line is not saturated even in "the saturated regime of the Ca II emission lines," i.e., Rossby number < 10^(-1.1). The Mg I emission line is considered to be a good indicator of chromospheric activity, particularly for active objects.
△ Less
Submitted 4 February, 2022;
originally announced February 2022.
-
Material radiopurity control in the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino,
M. Clark
, et al. (128 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove…
▽ More
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
△ Less
Submitted 26 January, 2023; v1 submitted 10 December, 2021;
originally announced December 2021.
-
Rotation-Activity Relation of Ca II and Mg I Infrared Emission Lines of Young Stars
Authors:
Mai Yamashita,
Yoichi Itoh,
Yuhei Takagi
Abstract:
To reveal the detail of the internal structure, the relationship between chromospheric activity and the Rossby number, N_R (= rotational period P / convective turnover time tau_c), has been extensively examined for main-sequence stars. The goal of our work is to apply the same methods to pre-main-sequence (PMS) stars and identify the appropriate model of tau_c for them. Yamashita et al. (2020) inv…
▽ More
To reveal the detail of the internal structure, the relationship between chromospheric activity and the Rossby number, N_R (= rotational period P / convective turnover time tau_c), has been extensively examined for main-sequence stars. The goal of our work is to apply the same methods to pre-main-sequence (PMS) stars and identify the appropriate model of tau_c for them. Yamashita et al. (2020) investigated the relationship between N_R and strengths of the Ca II infrared triplet (IRT; lambda 8498, 8542, 8662 A) emission lines of 60 PMS stars. Their equivalent widths are converted into the emission line to stellar bolometric luminosity ratio (R'). The 54 PMS stars have N_R < 10^{-1.0} and show R' \sim 10^{-4.2} as large as the maximum R' of the zero-age main-sequence (ZAMS) stars. However, because all R' was saturated against N_R, it was not possible to estimate the appropriate tau_c model for the PMS stars. We noticed that Mg I emission lines at 8808 A is an optically thin chromospheric line, appropriate for determination of the adequate tau_c for PMS stars. Using the archive data of the Anglo-Australian Telescope (AAT)/the University College London Echelle Spectrograph (UCLES), we investigated the Mg I line of 52 ZAMS stars. After subtracting photospheric absorption component, the Mg I line is detected as an emission line in 45 ZAMS stars, whose R' is between 10^{-5.9} and 10^{-4.1}. The Mg I line is not saturated yet in "the saturated regime for the Ca II emission lines", i.e. 10^{-1.6} < N_R < 10^{-0.8}. Therefore, the adequate tau_c for PMS stars can be determined by measuring of their R' values.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Search for inelastic scattering of WIMP dark matter in XENON1T
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
S. Andaloro,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (116 additional authors not shown)
Abstract:
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of i…
▽ More
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2$σ$. A profile-likelihood ratio analysis is used to set upper limits on the cross-section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100 GeV/c${}^2$, with the strongest upper limit of $3.3 \times 10^{-39}$ cm${}^2$ for 130 GeV/c${}^2$ WIMPs at 90\% confidence level.
△ Less
Submitted 26 February, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Measurements of the Ca II infrared triplet emission lines of pre-main-sequence stars
Authors:
Mai Yamashita,
Yoichi Itoh,
Yuhei Takagi
Abstract:
We investigated the chromospheric activity of 60 pre-main-sequence (PMS) stars in four molecular clouds and five moving groups. It is considered that strong chromospheric activity is driven by the dynamo processes generated by the stellar rotation. In contrast, several researchers have pointed out that the chromospheres of PMS stars are activated by mass accretion from their protoplanetary disks.…
▽ More
We investigated the chromospheric activity of 60 pre-main-sequence (PMS) stars in four molecular clouds and five moving groups. It is considered that strong chromospheric activity is driven by the dynamo processes generated by the stellar rotation. In contrast, several researchers have pointed out that the chromospheres of PMS stars are activated by mass accretion from their protoplanetary disks. In this study, the Ca II infrared triplet (IRT) emission lines were investigated utilizing medium- and high-resolution spectroscopy. The observations were conducted with Nayuta/MALLS and Subaru/HDS. Additionally, archive data obtained by Keck/HIRES, VLT/UVES, and VLT/X-Shooter was used. The small ratios of the equivalent widths indicate that Ca II IRT emission lines arise primarily in dense chromospheric regions. Seven PMS stars show broad emission lines. Among them, four PMS stars have more than one order of magnitude brighter emission line fluxes compared to the low-mass stars in young open clusters. The four PMS stars have a high mass accretion rate, which indicates that the broad and strong emission results from a large mass accretion. However, most PMS stars exhibit narrow emission lines. No significant correlation was found between the accretion rate and flux of the emission line. The ratios of the surface flux of the Ca II IRT lines to the stellar bolometric luminosity, R'_IRT, of the PMS stars with narrow emission lines are as large as the largest R'_IRT of the low-mass stars in the young open clusters. This result indicates that most PMS stars, even in the classical T Tauri star stage, have chromospheric activity similar to zero-age main-sequence stars.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (115 additional authors not shown)
Abstract:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c…
▽ More
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
△ Less
Submitted 17 November, 2020; v1 submitted 17 July, 2020;
originally announced July 2020.
-
Excess Electronic Recoil Events in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (114 additional authors not shown)
Abstract:
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is o…
▽ More
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$σ$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$, $g_{ae}g_{an}^{eff}<4.8\times 10^{-18}$, and $g_{ae}g_{aγ}<7.7\times10^{-22} GeV^{-1}$, and excludes either $g_{ae}=0$ or $g_{ae}g_{aγ}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic moment signal is similarly favored over background at 3.2$σ$ and a confidence interval of $μ_ν \in (1.4,2.9)\times10^{-11}μ_B$ (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by $β$ decays of tritium at 3.2$σ$ with a trace amount that can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are reduced to 2.0$σ$ and 0.9$σ$, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ($2.3\pm0.2$) keV (68% C.L.) with a 3.0$σ$ global (4.0$σ$ local) significance. We also consider the possibility that $^{37}$Ar may be present in the detector and yield a 2.82 keV peak. Contrary to tritium, the $^{37}$Ar concentration can be tightly constrained and is found to be negligible.
△ Less
Submitted 16 October, 2020; v1 submitted 17 June, 2020;
originally announced June 2020.
-
Search for exotic neutrino-electron interactions using solar neutrinos in XMASS-I
Authors:
XMASS collaboration,
K. Abe,
Y. Chen,
K. Hiraide,
K. Ichimura,
S. Imaizumi,
N. Kato,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Martens
, et al. (13 additional authors not shown)
Abstract:
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three spec…
▽ More
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three species of neutrino have common millicharge. We also set flavor dependent limits assuming the respective neutrino flavor is the only one carrying a millicharge, $7.3 \times 10^{-12} e$ for $ν_e$, $1.1 \times 10^{-11} e$ for $ν_μ$, and $1.1 \times 10^{-11} e$ for $ν_τ$. These limits are the most stringent yet obtained from direct measurements. We also obtain an upper limit for the neutrino magnetic moment of 1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for the coupling constant of dark photons in the $U(1)_{B-L}$ model of 1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$, and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
△ Less
Submitted 14 August, 2020; v1 submitted 24 May, 2020;
originally announced May 2020.
-
Energy resolution and linearity of XENON1T in the MeV energy range
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (113 additional authors not shown)
Abstract:
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN…
▽ More
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
△ Less
Submitted 9 September, 2020; v1 submitted 8 March, 2020;
originally announced March 2020.
-
New constraint on the atmosphere of (50000) Quaoar from a stellar occultation
Authors:
Ko Arimatsu,
Ryou Ohsawa,
George L. Hashimoto,
Seitaro Urakawa,
Jun Takahashi,
Miyako Tozuka,
Yoichi Itoh,
Misato Yamashita,
Fumihiko Usui,
Tsutomu Aoki,
Noriaki Arima,
Mamoru Doi,
Makoto Ichiki,
Shiro Ikeda,
Yoshifusa Ita,
Toshihiro Kasuga,
Naoto Kobayashi,
Mitsuru Kokubo,
Masahiro Konishi,
Hiroyuki Maehara,
Noriyuki Matsunaga,
Takashi Miyata,
Mikio Morii,
Tomoki Morokuma,
Kentaro Motohara
, et al. (13 additional authors not shown)
Abstract:
We report observations of a stellar occultation by the classical Kuiper belt object (50000) Quaoar occurred on 28 June 2019. A single-chord high-cadence (2 Hz) photometry dataset was obtained with the Tomo-e Gozen CMOS camera mounted on the 1.05 m Schmidt telescope at Kiso Observatory. The obtained ingress and egress data do not show any indication of atmospheric refraction and allow to set new…
▽ More
We report observations of a stellar occultation by the classical Kuiper belt object (50000) Quaoar occurred on 28 June 2019. A single-chord high-cadence (2 Hz) photometry dataset was obtained with the Tomo-e Gozen CMOS camera mounted on the 1.05 m Schmidt telescope at Kiso Observatory. The obtained ingress and egress data do not show any indication of atmospheric refraction and allow to set new $1σ$ and $3σ$ upper limits of 6 and 16 nbar, respectively, for the surface pressure of a pure methane atmosphere. These upper limits are lower than the saturation vapor pressure of methane at Quaoar's expected mean surface temperature ($T \sim 44$ K) and imply the absence of a $\sim$10 nbar-level global atmosphere formed by methane ice on Quaoar's surface.
△ Less
Submitted 22 October, 2019;
originally announced October 2019.
-
Search for WIMP-$^{129}$Xe inelastic scattering with particle identification in XMASS-I
Authors:
XMASS Collaboration,
T. Suzuki,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classific…
▽ More
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classification based on scintillation timing that distinguished $γ$-rays and $β$-rays, and simultaneous fitting of the energy spectra of $γ$-like and $β$-like samples. No evidence of a WIMP signal was found. Thus, we set the upper limits of the inelastic channel cross section at 90\% confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\; {\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm GeV}/c^2$ than the existing experimental limit.
△ Less
Submitted 19 March, 2019; v1 submitted 14 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Direct dark matter search by annual modulation with 2.7 years of XMASS-I data
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more…
▽ More
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.
△ Less
Submitted 25 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Using 220Rn to calibrate liquid noble gas detectors
Authors:
M. Kobayashi,
M. Yamashita,
A. Takeda,
K. Kishimoto,
S. Moriyama
Abstract:
In this paper, we describe 220Rn calibration source that was developed for liquid noble gas detectors. The key advantage of this source is that it can provide 212Bi-212Po consecutive events, which enables us to evaluate the vertex resolution of a detector at low energy by comparing low-energy events of 212Bi and corresponding higher-energy alpha-rays from 212Po. Since 220Rn is a noble gas, a hot m…
▽ More
In this paper, we describe 220Rn calibration source that was developed for liquid noble gas detectors. The key advantage of this source is that it can provide 212Bi-212Po consecutive events, which enables us to evaluate the vertex resolution of a detector at low energy by comparing low-energy events of 212Bi and corresponding higher-energy alpha-rays from 212Po. Since 220Rn is a noble gas, a hot metal getter can be used when introduced using xenon as the carrier gas. In addition, no long-life radioactive isotopes are left behind in the detector after the calibration is complete; this has clear advantage over the use of 222Rn which leaves long- life radioactivity, i.e., 210Pb. Using a small liquid xenon test chamber, we developed a system to introduce 220Rn via the xenon carrier gas; we demonstrated the successful introduction of 6 times 10^2 220Rn atoms in our test environment.
△ Less
Submitted 7 March, 2016;
originally announced March 2016.
-
Direct Dark Matter Search with XMASS-I
Authors:
Masaki Yamashita
Abstract:
XMASS-I uses single phase liquid xenon technology for aiming at the direct detection of dark matter. The detector observes only scintillation light by 2 inch 642 PMTs which are placed in sphere shape around an active volume. With its large mass target and high photoelectron yield, we conducted a search for dark matter by annual modulation with 832 kg $\times$ 359.2 days exposure of data. We find n…
▽ More
XMASS-I uses single phase liquid xenon technology for aiming at the direct detection of dark matter. The detector observes only scintillation light by 2 inch 642 PMTs which are placed in sphere shape around an active volume. With its large mass target and high photoelectron yield, we conducted a search for dark matter by annual modulation with 832 kg $\times$ 359.2 days exposure of data. We find no modulation signal in the data so that we set an upper limit 4.3$\times10^{-41} \rm{cm}^{2} $ at WIMP mass of 8 GeV/$c^{2}$ which excluded an interpreted DAMA/LIBRA allowed region.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Search for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Ichimura,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi
, et al. (20 additional authors not shown)
Abstract:
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data…
▽ More
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data no significant excess above background was observed in the fiducial mass of 41 kg. The present limit for the vector super-WIMPs excludes the possibility that such particles constitute all of dark matter. The absence of a signal also provides the most stringent direct constraint on the coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented sensitivity was achieved exploiting the low background at a level $10^{-4}$ kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
△ Less
Submitted 21 August, 2014; v1 submitted 2 June, 2014;
originally announced June 2014.
-
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from the XMASS-I experiment
Authors:
H. Uchida,
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (21 additional authors not shown)
Abstract:
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to…
▽ More
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to derive our limits without explicitly subtracting the remaining events which are compatible with background expectations and derive for e.g. a 50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei of 3.2 pb at the 90% confidence level.
△ Less
Submitted 29 April, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.
-
XMASS detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Nishiie,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (23 additional authors not shown)
Abstract:
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
△ Less
Submitted 13 January, 2013;
originally announced January 2013.
-
Search for solar axions in XMASS, a large liquid-xenon detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi,
A. Murata
, et al. (21 additional authors not shown)
Abstract:
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The b…
▽ More
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are 1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced the most stringent limit, which is better than that previously derived from astrophysical arguments regarding the Sun to date.
△ Less
Submitted 29 May, 2013; v1 submitted 26 December, 2012;
originally announced December 2012.
-
Light WIMP search in XMASS
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi,
A. Murata
, et al. (21 additional authors not shown)
Abstract:
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the analysis threshold can be lowered to 0.3 keVee (electron-equivalent) to search for light dark matter. With low-threshold data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and without discr…
▽ More
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the analysis threshold can be lowered to 0.3 keVee (electron-equivalent) to search for light dark matter. With low-threshold data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and without discriminating between nuclear-recoil and electronic events, XMASS excludes part of the parameter space favored by other experiments.
△ Less
Submitted 16 January, 2013; v1 submitted 22 November, 2012;
originally announced November 2012.
-
The XENON100 Dark Matter Experiment
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
E. Brown,
J. M. R. Cardoso,
B. Choi,
D. Cline,
S. Fattori,
A. D. Ferella,
K. L. Giboni,
A. Kish,
C. W. Lam,
R. F. Lang,
K. E. Lim,
J. A. M. Lopes,
T. Marrodan Undagoitia,
Y. Mei,
A. J. Melgarejo Fernandez,
K. Ni,
U. Oberlack,
S. E. A. Orrigo
, et al. (11 additional authors not shown)
Abstract:
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science ru…
▽ More
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of σ= 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
△ Less
Submitted 8 February, 2012; v1 submitted 11 July, 2011;
originally announced July 2011.
-
A search for light dark matter in XENON10 data
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_χ=8 GeV. We f…
▽ More
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_χ=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
△ Less
Submitted 7 May, 2013; v1 submitted 15 April, 2011;
originally announced April 2011.
-
Lowering the low-energy threshold of xenon detectors
Authors:
P. Sorensen,
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey
, et al. (12 additional authors not shown)
Abstract:
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This me…
▽ More
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
△ Less
Submitted 29 November, 2010;
originally announced November 2010.
-
Design and Performance of the XENON10 Dark Matter Experiment
Authors:
E. Aprile,
J. Angle,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (14 additional authors not shown)
Abstract:
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been publ…
▽ More
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
△ Less
Submitted 16 January, 2010;
originally announced January 2010.
-
Constraints on inelastic dark matter from XENON10
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of…
▽ More
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_χ\gtrsim150$ GeV are disfavored.
△ Less
Submitted 30 November, 2010; v1 submitted 19 October, 2009;
originally announced October 2009.
-
New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
Authors:
E. Aprile,
L. Baudis,
B. Choi,
K. L. Giboni,
K. E. Lim,
A. Manalaysay,
M. E. Monzani,
G. Plante,
R. Santorelli,
M. Yamashita
Abstract:
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitiv…
▽ More
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for maximum light collection. Greater than 95% of the interior surface of this detector was instrumented with photomultiplier tubes, giving a scintillation yield of 19.6 photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying constant around this value up to 10 keV. For higher energy recoils we measure a value around 20%, consistent with previously reported data. In light of this new measurement, the XENON10 experiment's results on spin-independent WIMP-nucleon cross section, which were calculated assuming a constant 0.19 relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to $9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from $4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30 GeV/c$^2$.
△ Less
Submitted 16 May, 2010; v1 submitted 1 October, 2008;
originally announced October 2008.
-
The scintillation and ionization yield of liquid xenon for nuclear recoils
Authors:
P. Sorensen,
A. Manzur,
C. E. Dahl,
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
D. N. McKinsey
, et al. (12 additional authors not shown)
Abstract:
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relati…
▽ More
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
△ Less
Submitted 30 December, 2008; v1 submitted 3 July, 2008;
originally announced July 2008.
-
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of…
▽ More
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
△ Less
Submitted 10 September, 2008; v1 submitted 19 May, 2008;
originally announced May 2008.
-
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind…
▽ More
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
△ Less
Submitted 3 December, 2007; v1 submitted 31 May, 2007;
originally announced June 2007.
-
Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
Authors:
E. Aprile,
K. L. Giboni,
P. Majewski,
K. Ni,
M. Yamashita
Abstract:
A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by reduced electron-ion recombination fluctuations of the combined signal compared to fluctuations of the individual signals. Simultaneous measurements of ionization…
▽ More
A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by reduced electron-ion recombination fluctuations of the combined signal compared to fluctuations of the individual signals. Simultaneous measurements of ionization and scintillation signals were carried out with Cs-137, Na-22 and Co-60 gamma rays, as a function of electric field in the liquid. A resolution of 1.7%(sigma) at 662 keV was measured at 1 kV/cm, significantly better than the resolution from either scintillation or ionization alone. A detailed analysis indicates that further improvement to less than 1%(sigma) is possible with higher light collection efficiency and lower electronic noise.
△ Less
Submitted 9 April, 2007;
originally announced April 2007.
-
3D Position Sensitive XeTPC for Dark Matter Search
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
L. Coelho,
E. Dahl,
L. DeViveiros,
A. Ferella,
L. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. -L. Giboni,
R. Gomez,
R. Hasty,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. McKinsey,
M. E. Monzani,
K. Ni,
U. Oberlack
, et al. (8 additional authors not shown)
Abstract:
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
△ Less
Submitted 26 September, 2006;
originally announced September 2006.
-
Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
Authors:
K. Ni,
E. Aprile,
K. L. Giboni,
P. Majewski,
M. Yamashita
Abstract:
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a me…
▽ More
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best achievable energy resolution, by removing the instrumental fluctuations, from liquid xenon scintillation light is estimated to be around 6-8% (sigma) for gamma-ray with energy between 662 keV and 122 keV.
△ Less
Submitted 4 August, 2006; v1 submitted 3 August, 2006;
originally announced August 2006.
-
Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
Authors:
E. Aprile,
C. E. Dahl,
L. DeViveiros,
R. Gaitskell,
K. L. Giboni,
J. Kwong,
P. Majewski,
K. Ni,
T. Shutt,
M. Yamashita
Abstract:
We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber prototypes, developed for the XENON Dark Matter project. We find that the charge yield increases with decreasing recoil energy, and exhibits only a weak field dependen…
▽ More
We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber prototypes, developed for the XENON Dark Matter project. We find that the charge yield increases with decreasing recoil energy, and exhibits only a weak field dependence. These results are a first demonstration of the capability of dual phase xenon detectors to discriminate between electron and nuclear recoils, a key requirement for a sensitive dark matter search at recoil energies down to 20 keV.
△ Less
Submitted 24 January, 2006;
originally announced January 2006.
-
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Authors:
E. Aprile,
K. L. Giboni,
P. Majewski,
K. Ni,
M. Yamashita,
R. Hasty,
A. Manzur,
D. N. McKinsey
Abstract:
Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report o…
▽ More
Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report on new measurements of the scintillation yield of Xe recoils with kinetic energy as low as 10 keV. The dependence of the scintillation yield on applied electric field was also measured in the range of 0 to 4 kV/cm. Results are in good agreement with recent theoretical predictions that take into account the effect of biexcitonic collisions in addition to the nuclear quenching effect.
△ Less
Submitted 29 March, 2005;
originally announced March 2005.
-
Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber
Authors:
K. Ni,
E. Aprile,
D. Day,
K. L. Giboni,
J. A. M. Lopes,
P. Majewski,
M. Yamashita
Abstract:
Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric fiel…
▽ More
Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded ionization chamber to measure the charge yield. We confirm that using a LAAPD in LXe does not introduce impurities which inhibit the drifting of free electrons.
△ Less
Submitted 14 February, 2005;
originally announced February 2005.
-
The XENON Dark Matter Search Experiment
Authors:
E. Aprile,
K. L. Giboni,
P. Majewski,
K. Ni,
M. Yamashita,
R. Gaitskell,
P. Sorensen,
L. DeViveiros,
L. Baudis,
A. Bernstein,
C. Hagmann,
C. Winant,
T. Shutt,
J. Kwong,
U. Oberlack,
D. McKinsey,
R. Hasty
Abstract:
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/g…
▽ More
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.
△ Less
Submitted 28 July, 2004;
originally announced July 2004.