-
Preliminary results of the Single Event Effect testing for the ULTRASAT sensors
Authors:
Vlad Dumitru Berlea,
Arooj Asif,
Merlin F. Barschke,
David Berge,
Juan Maria Haces Crespo,
Gianluca Giavitto,
Shashank Kumar,
Andrea Porelli,
Nicola de Simone,
Jason Watson,
Steven Worm,
Francesco Zappon,
Adi Birman,
Shay Alfassi,
Amos Feningstein,
Eli Waxman,
Udi Netzer,
Tuvia Liran,
Ofer Lapid,
Viktor M. Algranatti,
Yossi Schvartzvald
Abstract:
ULTRASAT (ULtra-violet TRansient Astronomy SATellite) is a wide-angle space telescope that will perform a deep time-resolved all-sky survey in the near-ultraviolet (NUV) spectrum. The science objectives are the detection of counterparts to short-lived transient astronomical events such as gravitational wave sources and supernovae. The mission is led by the Weizmann Institute of Science and is plan…
▽ More
ULTRASAT (ULtra-violet TRansient Astronomy SATellite) is a wide-angle space telescope that will perform a deep time-resolved all-sky survey in the near-ultraviolet (NUV) spectrum. The science objectives are the detection of counterparts to short-lived transient astronomical events such as gravitational wave sources and supernovae. The mission is led by the Weizmann Institute of Science and is planned for launch in 2026 in collaboration with the Israeli Space Agency and NASA. DESY will provide the UV camera, composed by the detector assembly located in the telescope focal plane and the remote electronics unit. The camera is composed out of four back-metallized CMOS Image Sensors (CIS) manufactured in the 4T, dual gain Tower process. As part of the radiation qualification of the camera, Single Event Effect (SEE) testing has been performed by irradiating the sensor with heavy ions at the RADEF, Jyvaskyla facility. Preliminary results of both Single Event Upset (SEU) and Single Event Latch-up (SEL) occurrence rate in the sensor are presented. Additionally, an in-orbit SEE rate simulation has been performed in order to gain preliminary knowledge about the expected effect of SEE on the mission.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
Total Ionizing Dose Effects on CMOS Image Sensor for the ULTRASAT Space Mission
Authors:
Vlad D. Berlea,
Steven Worm,
Nirmal Kaipachery,
Shrinivasrao R. Kulkarni,
Shashank Kumar,
Merlin F. Barschke,
David Berge,
Adi Birman,
Shay Alfassi,
Amos Fenigstein
Abstract:
ULTRASAT (ULtraviolet TRansient Astronomy SATellite) is a wide-angle space telescope that will perform deep time-resolved surveys in the near-ultraviolet spectrum. ULTRASAT is a space mission led by the Weizmann Institute of Science and the Israel Space Agency and is planned for launch in 2025. The camera implements backside-illuminated, stitched pixel sensors. The pixel has a dual-conversion-gain…
▽ More
ULTRASAT (ULtraviolet TRansient Astronomy SATellite) is a wide-angle space telescope that will perform deep time-resolved surveys in the near-ultraviolet spectrum. ULTRASAT is a space mission led by the Weizmann Institute of Science and the Israel Space Agency and is planned for launch in 2025. The camera implements backside-illuminated, stitched pixel sensors. The pixel has a dual-conversion-gain 4T architecture, with a pitch of $9.5$ $μm$ and is produced in a $180$ $nm$ process by Tower Semiconductor. Before the final sensor was available for testing, test sensors provided by Tower were used to gain first insights into the pixel's radiation tolerance. One of the main contributions to sensor degradation due to radiation for the ULTRASAT mission is Total Ionizing Dose (TID). TID measurements on the test sensors have been performed with a Co-60 gamma source at Helmholz Zentrum Berlin and CC-60 facility at CERN and preliminary results are presented.
△ Less
Submitted 27 June, 2023;
originally announced June 2023.
-
ULTRASAT: A wide-field time-domain UV space telescope
Authors:
Y. Shvartzvald,
E. Waxman,
A. Gal-Yam,
E. O. Ofek,
S. Ben-Ami,
D. Berge,
M. Kowalski,
R. Bühler,
S. Worm,
J. E. Rhoads,
I. Arcavi,
D. Maoz,
D. Polishook,
N. Stone,
B. Trakhtenbrot,
M. Ackermann,
O. Aharonson,
O. Birnholtz,
D. Chelouche,
D. Guetta,
N. Hallakoun,
A. Horesh,
D. Kushnir,
T. Mazeh,
J. Nordin
, et al. (19 additional authors not shown)
Abstract:
The Ultraviolet Transient Astronomy Satellite (ULTRASAT) is scheduled to be launched to geostationary orbit in 2026. It will carry a telescope with an unprecedentedly large field of view (204 deg$^2$) and NUV (230-290nm) sensitivity (22.5 mag, 5$σ$, at 900s). ULTRASAT will conduct the first wide-field survey of transient and variable NUV sources and will revolutionize our ability to study the hot…
▽ More
The Ultraviolet Transient Astronomy Satellite (ULTRASAT) is scheduled to be launched to geostationary orbit in 2026. It will carry a telescope with an unprecedentedly large field of view (204 deg$^2$) and NUV (230-290nm) sensitivity (22.5 mag, 5$σ$, at 900s). ULTRASAT will conduct the first wide-field survey of transient and variable NUV sources and will revolutionize our ability to study the hot transient universe: It will explore a new parameter space in energy and time-scale (months long light-curves with minutes cadence), with an extra-Galactic volume accessible for the discovery of transient sources that is $>$300 times larger than that of GALEX and comparable to that of LSST. ULTRASAT data will be transmitted to the ground in real-time, and transient alerts will be distributed to the community in $<$15 min, enabling a vigorous ground-based follow-up of ULTRASAT sources. ULTRASAT will also provide an all-sky NUV image to $>$23.5 AB mag, over 10 times deeper than the GALEX map. Two key science goals of ULTRASAT are the study of mergers of binaries involving neutron stars, and supernovae: With a large fraction ($>$50%) of the sky instantaneously accessible, fast (minutes) slewing capability and a field-of-view that covers the error ellipses expected from GW detectors beyond 2025, ULTRASAT will rapidly detect the electromagnetic emission following BNS/NS-BH mergers identified by GW detectors, and will provide continuous NUV light-curves of the events; ULTRASAT will provide early (hour) detection and continuous high (minutes) cadence NUV light curves for hundreds of core-collapse supernovae, including for rarer supernova progenitor types.
△ Less
Submitted 27 April, 2023;
originally announced April 2023.
-
Performance of the MALTA Telescope
Authors:
Milou van Rijnbach,
Giuliano Gustavino,
Phil Allport,
Igancio Asensi,
Dumitru Vlad Berlea,
Daniela Bortoletto,
Craig Buttar,
Edoardo Charbon,
Florian Dachs,
Valerio Dao,
Dominik Dobrijevic,
Leyre Flores Sanz de Acedo,
Andrea Gabrielli,
Martin Gazi,
Laura Gonella,
Vicente Gonzalez,
Stefan Guindon,
Matt LeBlanc,
Heinz Pernegger,
Francesco Piro,
Petra Riedler,
Heidi Sandaker,
Abhishek Sharma,
Carlos Solans Sanchez,
Walter Snoeys
, et al. (5 additional authors not shown)
Abstract:
MALTA is part of the Depleted Monolithic Active Pixel sensors designed in Tower 180nm CMOS imaging technology. A custom telescope with six MALTA planes has been developed for test beam campaigns at SPS, CERN, with the ability to host several devices under test. The telescope system has a dedicated custom readout, online monitoring integrated into DAQ with realtime hit map, time distribution and ev…
▽ More
MALTA is part of the Depleted Monolithic Active Pixel sensors designed in Tower 180nm CMOS imaging technology. A custom telescope with six MALTA planes has been developed for test beam campaigns at SPS, CERN, with the ability to host several devices under test. The telescope system has a dedicated custom readout, online monitoring integrated into DAQ with realtime hit map, time distribution and event hit multiplicity. It hosts a dedicated fully configurable trigger system enabling to trigger on coincidence between telescope planes and timing reference from a scintillator. The excellent time resolution performance allows for fast track reconstruction, due to the possibility to retain a low hit multiplicity per event which reduces the combinatorics. This paper reviews the architecture of the system and its performance during the 2021 and 2022 test beam campaign at the SPS North Area.
△ Less
Submitted 21 April, 2023; v1 submitted 3 April, 2023;
originally announced April 2023.
-
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
Authors:
J. Aalbers,
D. S. Akerib,
C. W. Akerlof,
A. K. Al Musalhi,
F. Alder,
A. Alqahtani,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
S. Azadi,
A. J. Bailey,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
M. J. Barry,
J. Barthel,
D. Bauer,
A. Baxter
, et al. (322 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis s…
▽ More
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.
△ Less
Submitted 2 August, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
Measuring the stability of fundamental constants with a network of clocks
Authors:
G. Barontini,
L. Blackburn,
V. Boyer,
F. Butuc-Mayer,
X. Calmet,
J. R. Crespo Lopez-Urrutia,
E. A. Curtis,
B. Darquie,
J. Dunningham,
N. J. Fitch,
E. M. Forgan,
K. Georgiou,
P. Gill,
R. M. Godun,
J. Goldwin,
V. Guarrera,
A. C. Harwood,
I. R. Hill,
R. J. Hendricks,
M. Jeong,
M. Y. H. Johnson,
M. Keller,
L. P. Kozhiparambil Sajith,
F. Kuipers,
H. S. Margolis
, et al. (19 additional authors not shown)
Abstract:
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the…
▽ More
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the goal of the recently launched QSNET project: A network of clocks for measuring the stability of fundamental constants. QSNET will include state-of-the-art atomic clocks, but will also develop next-generation molecular and highly charged ion clocks with enhanced sensitivity to variations of fundamental constants. We describe the technological and scientific aims of QSNET and evaluate its expected performance. We show that in the range of parameters probed by QSNET, either we will discover new physics, or we will impose new constraints on violations of fundamental symmetries and a range of theories beyond the Standard Model, including dark matter and dark energy models.
△ Less
Submitted 11 May, 2022; v1 submitted 20 December, 2021;
originally announced December 2021.
-
QSNET, a network of clocks for measuring the stability of fundamental constants
Authors:
G. Barontini,
V. Boyer,
X. Calmet,
N. J. Fitch,
E. M. Forgan,
R. M. Godun,
J. Goldwin,
V. Guarrera,
I. R. Hill,
M. Jeong,
M. Keller,
F. Kuipers,
H. S. Margolis,
P. Newman,
L. Prokhorov,
J. Rodewald,
B. E. Sauer,
M. Schioppo,
N. Sherrill,
M. R. Tarbutt,
A. Vecchio,
S. Worm
Abstract:
The QSNET consortium is building a UK network of next-generation atomic and molecular clocks that will achieve unprecedented sensitivity in testing variations of the fine structure constant, $α$, and the electron-to-proton mass ratio, $μ$. This in turn will provide more stringent constraints on a wide range of fundamental and phenomenological theories beyond the Standard Model and on dark matter m…
▽ More
The QSNET consortium is building a UK network of next-generation atomic and molecular clocks that will achieve unprecedented sensitivity in testing variations of the fine structure constant, $α$, and the electron-to-proton mass ratio, $μ$. This in turn will provide more stringent constraints on a wide range of fundamental and phenomenological theories beyond the Standard Model and on dark matter models.
△ Less
Submitted 12 October, 2021;
originally announced October 2021.
-
Sensor characterization for the ULTRASAT space telescope
Authors:
Benjamin Bastian-Querner,
Nirmal Kaipachery,
Daniel Küsters,
Julian Schliwinski,
Shay Alfassi,
Arooj Asif,
Merlin F. Barschke,
Sagi Ben-Ami,
David Berge,
Adi Birman,
Rolf Bühler,
Nicola De Simone,
Amos Fenigstein,
Avishay Gal-Yam,
Gianluca Giavitto,
Juan M. Haces Crespo,
Dmitri Ivanov,
Omer Katz,
Marek Kowalski,
Shrinivasrao R. Kulkarni,
Ofer Lapid,
Tuvia Liran,
Ehud Netzer,
Eran O. Ofek,
Sebastian Philipp
, et al. (9 additional authors not shown)
Abstract:
The Ultraviolet Transient Astronomical Satellite is a scientific space mission carrying an astronomical telescope. The mission is led by the Weizmann Institute of Science in Israel and the Israel Space Agency, while the camera in the focal plane is designed and built by Deutsches Elektronen Synchrotron in Germany. Two key science goals of the mission are the detection of counterparts to gravitatio…
▽ More
The Ultraviolet Transient Astronomical Satellite is a scientific space mission carrying an astronomical telescope. The mission is led by the Weizmann Institute of Science in Israel and the Israel Space Agency, while the camera in the focal plane is designed and built by Deutsches Elektronen Synchrotron in Germany. Two key science goals of the mission are the detection of counterparts to gravitational wave sources and supernovae. The launch to geostationary orbit is planned for 2024. The telescope with a field-of-view of $\approx200$deg$^2$, is optimized to work in the near-ultraviolet band between $220$ and $280$nm. The focal plane array is composed of four $22.4$-megapixel, backside-illuminated CMOS sensors with a total active area of 90x90mm$^2$. Prior to sensor production, smaller test sensors have been tested to support critical design decisions for the final flight sensor. These test sensors share the design of epitaxial layer and anti-reflective coatings (ARC) with the flight sensors. Here, we present a characterization of these test sensors. Dark current and read noise are characterized as a function of the device temperature. A temperature-independent noise level is attributed to on-die infrared emission and the read-out electronics` self-heating. We utilize a high-precision photometric calibration setup to obtain the test sensors` quantum efficiency (QE) relative to PTB/NIST-calibrated transfer standards ($220$-$1100$nm), the quantum yield for $λ< 300$nm, the non-linearity of the system, and the conversion gain. The uncertainties are discussed in the context of the newest results on the setup`s performance parameters. From three ARC options, Tstd, T1 and T2, the latter optimizes out-of-band rejection and peaks in the mid of the ULTRASAT operational waveband (max. QE $\approx80\%$ at $245\mathrm{nm}$). We recommend ARC option T2 for the final ULTRASAT UV sensor.
△ Less
Submitted 5 August, 2021;
originally announced August 2021.
-
Design of the ULTRASAT UV camera
Authors:
Arooj Asif,
Merlin Barschke,
Benjamin Bastian-Querner,
David Berge,
Rolf Bühler,
Nicola De Simone,
Gianluca Giavitto,
Juan M. Haces Crespo,
Nirmal Kaipachery,
Marek Kowalski,
Shrinivasrao R. Kulkarni,
Daniel Küsters,
Sebastian Philipp,
Heike Prokoph,
Julian Schliwinski,
Mikhail Vasilev,
Jason J. Watson,
Steven Worm,
Francesco Zappon,
Shay Alfassi,
Sagi Ben-Ami,
Adi Birman,
Kasey Boggs,
Greg Bredthauer,
Amos Fenigstein
, et al. (12 additional authors not shown)
Abstract:
The Ultraviolet Transient Astronomical Satellite (ULTRASAT) is a scientific UV space telescope that will operate in geostationary orbit. The mission, targeted to launch in 2024, is led by the Weizmann Institute of Science (WIS) in Israel and the Israel Space Agency (ISA). Deutsches Elektronen Synchrotron (DESY) in Germany is tasked with the development of the UV-sensitive camera at the heart of th…
▽ More
The Ultraviolet Transient Astronomical Satellite (ULTRASAT) is a scientific UV space telescope that will operate in geostationary orbit. The mission, targeted to launch in 2024, is led by the Weizmann Institute of Science (WIS) in Israel and the Israel Space Agency (ISA). Deutsches Elektronen Synchrotron (DESY) in Germany is tasked with the development of the UV-sensitive camera at the heart of the telescope. The camera's total sensitive area of ~90mm x 90mm is built up by four back-side illuminated CMOS sensors, which image a field of view of ~200 deg2. Each sensor has 22.4 megapixels. The Schmidt design of the telescope locates the detector inside the optical path, limiting the overall size of the assembly. As a result, the readout electronics is located in a remote unit outside the telescope. The short focal length of the telescope requires an accurate positioning of the sensors within +-50 mu along the optical axis, with a flatness of +-10 mu. While the telescope will be at around 295K during operations, the sensors are required to be cooled to 200K for dark current reduction. At the same time, the ability to heat the sensors to 343K is required for decontamination. In this paper, we present the preliminary design of the UV sensitive ULTRASAT camera.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
H. M. Araújo,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
D. Bauer,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
B. Carlson
, et al. (153 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up…
▽ More
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector.
For a 1000~live day run using a 5.6~tonne fiducial mass, LZ is projected to exclude at 90\% confidence level spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$~cm$^{2}$ for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5σ$ discovery potential is projected reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.3 \times 10^{-43}$~cm$^{2}$ ($7.1 \times 10^{-42}$~cm$^{2}$) for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
△ Less
Submitted 2 December, 2019; v1 submitted 16 February, 2018;
originally announced February 2018.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.