-
First Results from a Broadband Search for Dark Photon Dark Matter in the $44$ to $52\,μ$eV range with a coaxial dish antenna
Authors:
Stefan Knirck,
Gabe Hoshino,
Mohamed H. Awida,
Gustavo I. Cancelo,
Martin Di Federico,
Benjamin Knepper,
Alex Lapuente,
Mira Littmann,
David W. Miller,
Donald V. Mitchell,
Derrick Rodriguez,
Mark K. Ruschman,
Matthew A. Sawtell,
Leandro Stefanazzi,
Andrew Sonnenschein,
Gary W. Teafoe,
Daniel Bowring,
G. Carosi,
Aaron Chou,
Clarence L. Chang,
Kristin Dona,
Rakshya Khatiwada,
Noah A. Kurinsky,
Jesse Liu,
Cristián Pena
, et al. (3 additional authors not shown)
Abstract:
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are re…
▽ More
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon - photon mixing parameters $χ\gtrsim 10^{-12}$ in this range at 90% confidence level. This surpasses existing constraints by about two orders of magnitude and is the most stringent bound on dark photons in this range below 49 $μ$eV.
△ Less
Submitted 3 May, 2024; v1 submitted 20 October, 2023;
originally announced October 2023.
-
The First GECAM Observation Results on Terrestrial Gamma-ray Flashes and Terrestrial Electron Beams
Authors:
Y. Zhao,
J. C. Liu,
S. L. Xiong,
W. C. Xue,
Q. B. Yi,
G. P. Lu,
W. Xu,
F. C. Lyu,
J. C. Sun,
W. X. Peng,
C. Zheng,
Y. Q. Zhang,
C. Cai,
S. Xiao,
S. L. Xie,
C. W. Wang,
W. J. Tan,
Z. H. An,
G. Chen,
Y. Q. Du,
Y. Huang,
M. Gao,
K. Gong,
D. Y. Guo,
J. J. He
, et al. (37 additional authors not shown)
Abstract:
Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a space-borne instrument dedicated to monitoring high-energy transients, including Terrestrial Gamma-ray Flashes (TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB-like events are identified during an effe…
▽ More
Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a space-borne instrument dedicated to monitoring high-energy transients, including Terrestrial Gamma-ray Flashes (TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB-like events are identified during an effective observation time of $\sim$9 months. We show that, with gamma-ray and charged particle detectors, GECAM can effectively identify and distinguish TGFs and TEBs, and measure their temporal and spectral properties in detail. A very high TGF-lightning association rate of $\sim$80\% is obtained between GECAM and GLD360 in east Asia region.
△ Less
Submitted 17 June, 2023;
originally announced June 2023.
-
GECAM detection of a bright type-I X-ray burst from 4U 0614+09: confirmation its spin frequency at 413 Hz
Authors:
Y. P. Chen,
J. Li,
S. L. Xiong,
L. Ji,
S. Zhang,
W. X. Peng,
R. Qiao,
X. Q. Li,
X. Y. Wen,
L. M. Song,
S. J. Zheng,
X. Y. Song,
X. Y. Zhao,
Y. Huang,
F. J. Lu,
S. N. Zhang,
S. Xiao,
C. Cai,
B. X. Zhang,
Z. H. An,
C. Chen,
G. Chen,
W. Chen,
G. Q. Dai,
Y. Q. Du
, et al. (65 additional authors not shown)
Abstract:
One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered w…
▽ More
One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered with \textit{Swift}/BAT \citep{Strohmayer2008}, and therefore confirms the spin frequency of this source. This burst is the brightest one in the normal bursts (except the superburst) ever detected from 4U~0614+09, which leads to an upper limit of distance estimation as 3.1 kpc. The folded light curve during the burst oscillation shows a multi-peak structure, which is the first case observed during a single burst oscillation in nonpulsating sources. The multi-peak profile could be due to additional harmonics of the burst oscillation, which is corresponding to several brighter/fainter spots at the stellar surface.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Ground-based calibration and characterization of GRD of GECAM: 8-160 keV
Authors:
J. J. He,
Z. H. An,
W. X. Peng,
X. Q. Li,
S. L. Xiong,
D. L. Zhang,
R. Qiao,
D. Y. Guo,
C. Cai,
Z. Chang,
C. Chen,
G. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
K. Gong,
D. J. Hou,
C. Y. Li,
G. Li,
L. Li,
M. S. Li,
X. B. Li,
X. F. Li,
Y. G. Li,
X. H. Liang
, et al. (36 additional authors not shown)
Abstract:
As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy ban…
▽ More
As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.