-
Nuclear Recoil Identification in a Scientific Charge-Coupled Device
Authors:
K. J. McGuire,
A. E. Chavarria,
N. Castello-Mor,
S. Lee,
B. Kilminster,
R. Vilar,
A. Alvarez,
J. Jung,
J. Cuevas-Zepeda,
C. De Dominicis,
R. Gaïor,
L. Iddir,
A. Letessier-Selvon,
H. Lin,
S. Munagavalasa,
D. Norcini,
S. Paul,
P. Privitera,
R. Smida,
M. Traina,
R. Yajur,
J-P. Zopounidis
Abstract:
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing nuclear recoil signals from electronic recoil backgrounds in the CCD silicon target. We present a technique for event-by-event identification of nuclear recoils bas…
▽ More
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing nuclear recoil signals from electronic recoil backgrounds in the CCD silicon target. We present a technique for event-by-event identification of nuclear recoils based on the spatial correlation between the primary ionization event and the lattice defect left behind by the recoiling atom, later identified as a localized excess of leakage current under thermal stimulation. By irradiating a CCD with an $^{241}$Am$^{9}$Be neutron source, we demonstrate $>93\%$ identification efficiency for nuclear recoils with energies $>150$ keV, where the ionization events were confirmed to be nuclear recoils from topology. The technique remains fully efficient down to 90 keV, decreasing to 50$\%$ at 8 keV, and reaching ($6\pm2$)$\%$ at 1.5--3.5 keV. Irradiation with a $^{24}$Na $γ$-ray source shows no evidence of defect generation by electronic recoils, with the fraction of electronic recoils with energies $<85$ keV that are spatially correlated with defects $<0.1$$\%$.
△ Less
Submitted 11 October, 2023; v1 submitted 14 September, 2023;
originally announced September 2023.
-
The DAMIC excess from WIMP-nucleus elastic scattering
Authors:
A. E. Chavarria,
H. Lin,
K. J. McGuire,
A. Piers,
M. Traina
Abstract:
Two dark matter searches performed with charge-coupled devices (CCDs) in the DAMIC cryostat at SNOLAB reported with high statistical significance the presence of an unidentified source of low-energy events in bulk silicon. The observed spectrum is consistent with nuclear recoils from the elastic scattering of weakly interacting massive particles (WIMPs) with masses between 2 and 4 GeV. In the stan…
▽ More
Two dark matter searches performed with charge-coupled devices (CCDs) in the DAMIC cryostat at SNOLAB reported with high statistical significance the presence of an unidentified source of low-energy events in bulk silicon. The observed spectrum is consistent with nuclear recoils from the elastic scattering of weakly interacting massive particles (WIMPs) with masses between 2 and 4 GeV. In the standard scenario of spin-independent WIMP-nucleus scattering, the derived cross section is conclusively excluded by results in argon by the DarkSide-50 experiment. We identify isospin-violating and spin-dependent scenarios where interactions with $^{40}$Ar are strongly suppressed and the interpretation of the DAMIC excess as WIMP-nucleus elastic scattering remains viable.
△ Less
Submitted 26 March, 2024; v1 submitted 23 August, 2023;
originally announced August 2023.
-
Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M
Authors:
I. Arnquist,
N. Avalos,
D. Baxter,
X. Bertou,
N. Castello-Mor,
A. E. Chavarria,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
J. Duarte-Campderros,
E. Estrada,
N. Gadola,
R. Gaior,
T. Hossbach,
L. Iddir,
B. J. Kavanagh,
B. Kilminster,
A. Lantero-Barreda,
I. Lawson,
S. Lee,
A. Letessier-Selvon,
P. Loaiza,
A. Lopez-Virto,
K. J. McGuire
, et al. (15 additional authors not shown)
Abstract:
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from D…
▽ More
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with periods in the range 1-48 h. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs
Authors:
A. Aguilar-Arevalo,
I. Arnquist,
N. Avalos,
L. Barak,
D. Baxter,
X. Bertou,
I. M. Bloch,
A. M. Botti,
M. Cababie,
G. Cancelo,
N. Castelló-Mor,
B. A. Cervantes-Vergara,
A. E. Chavarria,
J. Cortabitarte-Gutiérrez,
M. Crisler,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
A. Drlica-Wagner,
J. Duarte-Campderros,
J. C. D'Olivo,
R. Essig,
E. Estrada,
J. Estrada
, et al. (47 additional authors not shown)
Abstract:
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. W…
▽ More
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
△ Less
Submitted 26 March, 2024; v1 submitted 2 June, 2023;
originally announced June 2023.
-
First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons
Authors:
I. Arnquist,
N. Avalos,
D. Baxter,
X. Bertou,
N. Castello-Mor,
A. E. Chavarria,
J. Cuevas-Zepeda,
J. Cortabitarte Gutierrez,
J. Duarte-Campderros,
A. Dastgheibi-Fard,
O. Deligny,
C. De Dominicis,
E. Estrada,
N. Gadola,
R. Gaıor,
T. Hossbach,
L. Iddir,
L. Khalil,
B. Kilminster,
A. Lantero-Barreda,
I. Lawson,
S. Lee,
A. Letessier-Selvon,
P. Loaiza,
A. Lopez-Virto
, et al. (20 additional authors not shown)
Abstract:
We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the sub-electron charge resolution and low level of dark current of DAMIC-M Charge-Coupled Devices (CCDs). Dark-matter-induced ionization signals above the detector dark current…
▽ More
We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the sub-electron charge resolution and low level of dark current of DAMIC-M Charge-Coupled Devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7 e-. With this data set we place limits on dark matter particles of mass between 0.53 and 1000 MeV/c2, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/c2 and [1.5,15.1] MeV/c2 for ultra-light and heavy mediator interactions, respectively.
△ Less
Submitted 5 February, 2023;
originally announced February 2023.
-
The DAMIC-M Experiment: Status and First Results
Authors:
I. Arnquist,
N. Avalos,
P. Bailly,
D. Baxter,
X. Bertou,
M. Bogdan,
C. Bourgeois,
J. Brandt,
A. Cadiou,
N. Castelló-Mor,
A. E. Chavarria,
M. Conde,
N. J. Corso,
J. Cortabitarte Gutiérrez,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
R. Desani,
M. Dhellot,
J-J. Dormard,
J. Duarte-Campderros,
E. Estrada,
D. Florin,
N. Gadola
, et al. (47 additional authors not shown)
Abstract:
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV…
▽ More
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.
△ Less
Submitted 25 November, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection
Authors:
D. Norcini,
N. Castello-Mor,
D. Baxter,
N. J. Corso,
J. Cuevas-Zepeda,
C. De Dominicis,
A. Matalon,
S. Munagavalasa,
S. Paul,
P. Privitera,
K. Ramanathan,
R. Smida,
R. Thomas,
R. Yajur,
A. E. Chavarria,
K. McGuire,
P. Mitra,
A. Piers,
M. Settimo,
J. Cortabitarte Gutierrez,
J. Duarte-Campderros,
A. Lantero-Barreda,
A. Lopez-Virto,
I. Vila,
R. Vilar
, et al. (19 additional authors not shown)
Abstract:
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a…
▽ More
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $γ$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.
△ Less
Submitted 2 July, 2022;
originally announced July 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Results on Low-Mass Weakly Interacting Massive Particles from a 11 kg d Target Exposure of DAMIC at SNOLAB (ICRC2021 Proceedings)
Authors:
Michelangelo Traina
Abstract:
Experimental efforts of the last decades have been unsuccessful in detecting WIMPs (Weakly Interacting Massive Particles) in the 10-to-10$^4$ GeV/$c^2$ range, thus motivating the search for lighter dark matter. The DAMIC (DArk Matter In CCDs) at SNOLAB experiment aims for direct detection of light dark matter particles ($m_χ<$ 10 GeV/$c^2$) by means of CCDs (Charge-Coupled Devices). Fully-depleted…
▽ More
Experimental efforts of the last decades have been unsuccessful in detecting WIMPs (Weakly Interacting Massive Particles) in the 10-to-10$^4$ GeV/$c^2$ range, thus motivating the search for lighter dark matter. The DAMIC (DArk Matter In CCDs) at SNOLAB experiment aims for direct detection of light dark matter particles ($m_χ<$ 10 GeV/$c^2$) by means of CCDs (Charge-Coupled Devices). Fully-depleted 675 $μ$m-thick CCDs are used to such end. The optimized readout noise and operation at cryogenic temperatures allow for a detection threshold of 50 eV$_{\text{ee}}$ electron-equivalent energy. Focusing on nuclear and electronic scattering as potential detection processes, DAMIC has so far set competitive constraints on the detection of low mass WIMPs and hidden-sector particles. In this work, an 11 kg-day exposure dataset is exploited to search for light WIMPs by building the first comprehensive radioactive background model for CCDs. Different background sources are discriminated making conjoint use of the spatial distribution and energy of ionization events, thereby constraining the amount of contaminants such as tritium from silicon cosmogenic activation and surface lead-210 from radon plate-out. Despite a conspicuous, statistically-significant excess of events below 200 eV$_{\text{ee}}$, this analysis places the strongest exclusion limit on the WIMP-nucleon scattering cross section with a silicon target for 1 GeV $< m_χc^2<$ 9 GeV.
△ Less
Submitted 3 October, 2021; v1 submitted 12 August, 2021;
originally announced August 2021.
-
Results on Low-Mass Weakly Interacting Massive Particles from an 11 kg-day Target Exposure of DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaior,
Y. Guardincerri,
E. W. Hoppe,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
C. T. Overman,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis
, et al. (7 additional authors not shown)
Abstract:
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An exces…
▽ More
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $σ_{χ-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_χ$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_χ$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.
△ Less
Submitted 25 December, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.