Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera
Authors:
S. Go,
Y. Tsuzuki,
H. Yoneda,
Y. Ichikawa,
T. Ikeda,
N. Imai,
K. Imamura,
M. Niikura,
D. Nishimura,
R. Mizuno,
S. Takeda,
H. Ueno,
S. Watanabe,
T. Y. Saito,
S. Shimoura,
S. Sugawara,
A. Takamine,
T. Takahashi
Abstract:
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdT…
▽ More
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdTe) Compton camera can be a state-of-the-art gamma-ray polarimeter for nuclear spectroscopy with the high position sensitivity and the detection efficiency. We demonstrated the capability to operate this detector as a reliable gamma-ray polarimeter by using polarized 847-keV gamma rays produced by the $^{56}\rm{Fe}({\it p},{\it p'}γ)$ reaction. By combining the experimental data and simulated calculations, the modulation curve for the gamma ray was successfully obtained. A remarkably high polarization sensitivity was achieved, compatible with a reasonable detection efficiency. Based on the obtained results, a possible future gamma-ray polarimetery is discussed.
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
2-mm-Thick Large-Area CdTe Double-sided Strip Detectors for High-Resolution Spectroscopic Imaging of X-ray and Gamma-ray with Depth-Of-Interaction Sensing
Authors:
Takahiro Minami,
Miho Katsuragawa,
Shunsaku Nagasawa,
Shin'ichiro Takeda,
Shin Watanabe,
Yutaka Tsuzuki,
Tadayuki Takahashi
Abstract:
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in tens to hundreds keV. The detector can be employed in a wide variety of fields for quantitative observations of hard X-ray and soft gamma-ray with spectroscopic…
▽ More
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in tens to hundreds keV. The detector can be employed in a wide variety of fields for quantitative observations of hard X-ray and soft gamma-ray with spectroscopic imaging, for example, space observation, nuclear medicine, and non-destructive elemental analysis. This detector is thicker than the 0.75-mm-thick one previously developed by a factor of $\sim$2.7, thus providing better detection efficiency for hard X-rays and soft gamma rays. The increased thickness could potentially enhance bias-induced polarization if we do not apply sufficient bias and if we do not operate at a low temperature, but the polarization is not evident in our detector when a high voltage of 500 V is applied to the CdTe diode and the temperature is maintained at -20 $^\circ$C during one-day experiments. The ''Depth Of Interaction'' (DOI) dependence due to the CdTe diode's poor carrier-transport property is also more significant, resulting in much DOI information while complicated detector responses such as charge sharings or low-energy tails that exacerbate the loss in the energy resolution.
In this paper, we developed 2-mm-thick CdTe-DSDs, studied their response, and evaluated their energy resolution, spatial resolution, and uniformity. We also constructed a theoretical model to understand the detector response theoretically, resulting in reconstructing the DOI with an accuracy of 100 um while estimating the carrier-transport property. We realized the detector that has high energy resolution and high 3D spatial resolution with a uniform large imaging area.
△ Less
Submitted 17 December, 2023; v1 submitted 13 December, 2023;
originally announced December 2023.
-
Tomographic Imaging by a Si/CdTe Compton Camera for In-111 and I-131 Radionuclides
Authors:
Goro Yabu,
Hiroki Yoneda,
Tadashi Orita,
Shin'ichiro Takeda,
Pietro Caradonna,
Tadayuki Takahashi,
Shin Watanabe,
Fumiki Moriyama
Abstract:
Tomographic imaging with radionuclides commonly used in nuclear medicine, such as $^{111}$In (171 and 245 keV) and $^{131}$I (364 keV), is in high demand for medical applications and small animal imaging. The Si/CdTe Compton camera with its high angular and high energy resolutions is an especially promising detector to extend the energy coverage for imaging to the range that covers gamma-ray emitt…
▽ More
Tomographic imaging with radionuclides commonly used in nuclear medicine, such as $^{111}$In (171 and 245 keV) and $^{131}$I (364 keV), is in high demand for medical applications and small animal imaging. The Si/CdTe Compton camera with its high angular and high energy resolutions is an especially promising detector to extend the energy coverage for imaging to the range that covers gamma-ray emitted from these radionuclides. Here, we take the first steps towards short-distance imaging by conducting experiments using three-dimensional phantoms composed of multiple sphere-like solutions of $^{111}$In and $^{131}$I with a diameter of 2.7 mm, placed at a distance of 41 mm. Using simple back-projection methods, the positions of the sources are reproduced with a spatial resolution of 11.5 mm and 9.0 mm (FWHM) for $^{111}$In and $^{131}$I, respectively. We found that a LM-MLEM method gives a better resolution of 4.0 mm and 2.7 mm (FWHM). We resolve source positions of a tetrahedron structure with a source-to-source separation of 28 mm. These findings demonstrate that Compton Cameras have the potential of close-distance imaging of radioisotopes distributions in the energy range below 400 keV.
△ Less
Submitted 19 August, 2021;
originally announced August 2021.
-
Origin of the in-orbit instrumental background of the Hard X-ray Imager onboard Hitomi
Authors:
Kouichi Hagino,
Hirokazu Odaka,
Goro Sato,
Tamotsu Sato,
Hiromasa Suzuki,
Tsunefumi Mizuno,
Madoka Kawaharada,
Masanori Ohno,
Kazuhiro Nakazawa,
Shogo B. Kobayashi,
Hiroaki Murakami,
Katsuma Miyake,
Makoto Asai,
Tatsumi Koi,
Greg Madejski,
Shinya Saito,
Dennis H. Wright,
Teruaki Enoto,
Yasushi Fukazawa,
Katsuhiro Hayashi,
Jun Kataoka,
Junichiro Katsuta,
Motohide Kokubun,
Philippe Laurent,
Francois Lebrun
, et al. (21 additional authors not shown)
Abstract:
Understanding and reducing the in-orbit instrumental backgrounds are essential to achieving high sensitivity in hard X-ray astronomical observations. The observational data of the Hard X-ray Imager (HXI) on board the Hitomi satellite provides useful information on the background components, owing to its multi-layer configuration with different atomic numbers: the HXI consists of a stack of four la…
▽ More
Understanding and reducing the in-orbit instrumental backgrounds are essential to achieving high sensitivity in hard X-ray astronomical observations. The observational data of the Hard X-ray Imager (HXI) on board the Hitomi satellite provides useful information on the background components, owing to its multi-layer configuration with different atomic numbers: the HXI consists of a stack of four layers of Si (Z = 14) detectors and one layer of CdTe (Z = 48, 52) detector surrounded by well-type BGO (Bi4Ge3O12) active shields. Based on the observational data, the backgrounds of top Si layer, the three underlying Si layers, and the CdTe layer are inferred to be dominated by different components, namely, low-energy electrons, albedo neutrons, and proton-induced radioactivation, respectively. Monte Carlo simulations of the in-orbit background of the HXI reproduce the observed background spectrum of each layer well, thereby verifying the above hypothesis quantitatively. In addition, we suggest the inclusion of an electron shield to reduce the background.
△ Less
Submitted 20 November, 2020;
originally announced November 2020.
-
Development of a Low-noise Front-end ASIC for CdTe Detectors
Authors:
Tenyo Kawamura,
Tadashi Orita,
Shin'ichiro Takeda,
Shin Watanabe,
Hirokazu Ikeda,
Tadayuki Takahashi
Abstract:
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured withou…
▽ More
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured without connecting the ASIC to any detectors. From the spectroscopy measurements using a CdTe single-sided strip detector, the energy resolution of 1.12 keV (FWHM) is obtained at 13.9 keV, and photons within the energy from 6.4 keV to 122.1 keV are detected. Based on the experimental results, we propose a new low-noise readout architecture making use of a slew-rate limited mode at the shaper followed by a peak detector circuit.
△ Less
Submitted 31 August, 2020;
originally announced September 2020.
-
Imaging and Spectral Performance of a 60 μm Pitch CdTe Double-Sided Strip Detector
Authors:
Kento Furukawa,
Shunsaku Nagasawa,
Lindsay Glesener,
Miho Katsuragawa,
Shin'ichiro Takeda,
Shin Watanabe,
Tadayuki Takahashi
Abstract:
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of…
▽ More
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of the depth of photon interaction and charge sharing effects are of importance in order to provide good spectroscopic and imaging performance. We study the tail structure observed in the spectra caused by charge trap** and develop a new method to reconstruct the spectra based on induced charge information from both anode and cathode strips. By applying this method, energy resolutions (FWHM) of 0.76 keV and 1.0 keV can be obtained at photon energies of 14 keV and 60 keV, respectively, if the energy difference between the anode and cathode is within 1 keV. Furthermore, the tail component at 60 keV is reduced, and the energy resolution of the 60 keV peak is improved from 2.4 keV to 1.5 keV (FWHM) if the energy difference is greater than 1 keV. In order to study the imaging performance, we constructed a simple imaging system using a 5 mm thick tungsten plate that has a pinhole with a diameter of 100 um. We utilize a Ba-133 radioisotope of 1 mm in diameter as a target source in combination with a 100 um slit made from 0.5 mm thickness tungsten. We imaged the Ba-133 source behind the 100 um slit using a 30 keV peak, with a 100 um pinhole placed at the center of the source-detector distance. By applying a charge sharing correction between strips, we have succeeded in obtaining a position resolution better than the strip pitch of 60 um.
△ Less
Submitted 10 June, 2020;
originally announced June 2020.
-
Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. S…
▽ More
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
In-orbit performance and calibration of the Hard X-ray Imager onboard Hitomi (ASTRO-H)
Authors:
Kouichi Hagino,
Kazuhiro Nakazawa,
Goro Sato,
Motohide Kokubun,
Teruaki Enoto,
Yasushi Fukazawa,
Katsuhiro Hayashi,
Jun Kataoka,
Junichiro Katsuta,
Shogo B. Kobayashi,
Philippe Laurent,
Francois Lebrun,
Olivier Limousin,
Daniel Maier,
Kazuo Makishima,
Taketo Mimura,
Katsuma Miyake,
Tsunefumi Mizuno,
Kunishiro Mori,
Hiroaki Murakami,
Takeshi Nakamori,
Toshio Nakano,
Hirofumi Noda,
Hirokazu Odaka,
Masanori Ohno
, et al. (15 additional authors not shown)
Abstract:
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard X-ray telescope, it enables imaging spectroscopy with an angular resolution of $1^\prime.7$ half-power diameter, in a field of view of $9^\prime\times9^\prime$. The main imager is composed of 4 layers of Si detectors and 1 layer of CdTe detector, stacked…
▽ More
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard X-ray telescope, it enables imaging spectroscopy with an angular resolution of $1^\prime.7$ half-power diameter, in a field of view of $9^\prime\times9^\prime$. The main imager is composed of 4 layers of Si detectors and 1 layer of CdTe detector, stacked to cover wide energy band up to 80 keV, surrounded by an active shield made of BGO scintillator to reduce the background. The HXI started observations 12 days before the Hitomi loss, and successfully obtained data from G21.5$-$0.9, Crab and blank sky. Utilizing these data, we calibrate the detector response and study properties of in-orbit background. The observed Crab spectra agree well with a powerlaw model convolved with the detector response, within 5% accuracy. We find that albedo electrons in specified orbit strongly affect the background of Si top layer, and establish a screening method to reduce it. The background level over the full field of view after all the processing and screening is as low as the pre-flight requirement of $1$-$3\times10^{-4}$ counts s$^{-1}$ cm$^{-2}$ keV$^{-1}$.
△ Less
Submitted 21 May, 2018;
originally announced May 2018.
-
Imaging and spectral performance of CdTe double-sided strip detectors for the Hard X-ray Imager onboard ASTRO-H
Authors:
Kouichi Hagino,
Hirokazu Odaka,
Goro Sato,
Shin Watanabe,
Shin'ichiro Takeda,
Motohide Kokubun,
Taro Fukuyama,
Shinya Saito,
Tamotsu Sato,
Yuto Ichinohe,
Tadayuki Takahashi,
Toshio Nakano,
Kazuhiro Nakazawa,
Kazuo Makishima,
Hiroyasu Tajima,
Takaaki Tanaka,
Kazunori Ishibashi,
Takuya Miyazawa,
Michito Sakai,
Karin Sakanobe,
Hiroyoshi Kato,
Shunya Takizawa,
Kentaro Uesugi
Abstract:
The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of $-20^\circ$C and with an applied bias voltage of 250 V. By using two-strip events as well…
▽ More
The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of $-20^\circ$C and with an applied bias voltage of 250 V. By using two-strip events as well as one-strip events for the event reconstruction, a good energy resolution of 2.0 keV at 59.5 keV and a sub-strip spatial resolution was achieved. The hard X-ray and gamma-ray response of CdTe-DSDs is complex due to the properties of CdTe and the small pixel effect. Therefore, one of the issues to investigate is the response of the CdTe-DSD. In order to investigate the spatial dependence of the detector response, we performed fine beam scan experiments at SPring-8, a synchrotron radiation facility. From these experiments, the depth structure of the electric field was determined as well as properties of carriers in the detector and successfully reproduced the experimental data with simulated spectra.
△ Less
Submitted 20 May, 2018;
originally announced May 2018.
-
Modeling of proton-induced radioactivation background in hard X-ray telescopes: Geant4-based simulation and its demonstration by Hitomi's measurement in a low Earth orbit
Authors:
Hirokazu Odaka,
Makoto Asai,
Kouichi Hagino,
Tatsumi Koi,
Greg Madejski,
Tsunefumi Mizuno,
Masanori Ohno,
Shinya Saito,
Tamotsu Sato,
Dennis H. Wright,
Teruaki Enoto,
Yasushi Fukazawa,
Katsuhiro Hayashi,
Jun Kataoka,
Junichiro Katsuta,
Madoka Kawaharada,
Shogo B. Kobayashi,
Motohide Kokubun,
Philippe Laurent,
Francois Lebrun,
Olivier Limousin,
Daniel Maier,
Kazuo Makishima,
Taketo Mimura,
Katsuma Miyake
, et al. (25 additional authors not shown)
Abstract:
Hard X-ray astronomical observatories in orbit suffer from a significant amount of background due to radioactivation induced by cosmic-ray protons and/or geomagnetically trapped protons. Within the framework of a full Monte Carlo simulation, we present modeling of in-orbit instrumental background dominated by radioactivation. To reduce the computation time required by straightforward simulations o…
▽ More
Hard X-ray astronomical observatories in orbit suffer from a significant amount of background due to radioactivation induced by cosmic-ray protons and/or geomagnetically trapped protons. Within the framework of a full Monte Carlo simulation, we present modeling of in-orbit instrumental background dominated by radioactivation. To reduce the computation time required by straightforward simulations of delayed emissions from activated isotopes, we insert a semi-analytical calculation that converts production probabilities of radioactive isotopes by interaction of the primary protons into decay rates at measurement time of all secondary isotopes. Therefore, our simulation method is separated into three steps: (1) simulation of isotope production, (2) semi-analytical conversion to decay rates, and (3) simulation of decays of the isotopes at measurement time. This method is verified by a simple setup that has a CdTe semiconductor detector, and shows a 100-fold improvement in efficiency over the straightforward simulation. The simulation framework was tested against data measured with a CdTe sensor in the Hard X-ray Imager onboard the Hitomi X-ray Astronomy Satellite, which was put into a low Earth orbit with an altitude of 570 km and an inclination of 31 degrees, and thus experienced a large amount of irradiation from geomagnetically trapped protons during its passages through the South Atlantic Anomaly. The simulation is able to treat full histories of the proton irradiation and multiple measurement windows. The simulation results agree very well with the measured data, showing that the measured background is well described by the combination of proton-induced radioactivation of the CdTe detector itself and thick Bi4Ge3O12 scintillator shields, leakage of cosmic X-ray background and albedo gamma-ray radiation, and emissions from naturally contaminated isotopes in the detector system.
△ Less
Submitted 3 April, 2018;
originally announced April 2018.
-
Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (173 additional authors not shown)
Abstract:
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with…
▽ More
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Temperature Structure in the Perseus Cluster Core Observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated wi…
▽ More
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.
△ Less
Submitted 18 December, 2017;
originally announced December 2017.
-
Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, a…
▽ More
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that an accurate atomic code is as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current codes ready for the data from the next Hitomi-level mission.
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
Hitomi Observations of the LMC SNR N132D: Highly Redshifted X-ray Emission from Iron Ejecta
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on t…
▽ More
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km/s compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50-1500 km/s if a weakly informative prior is placed on possible line broadening. This indicates (1) that the Fe emission arises from the supernova ejecta, and (2) that these ejecta are highly asymmetric, since no blue-shifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial map** that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.
△ Less
Submitted 6 December, 2017;
originally announced December 2017.
-
Glimpse of the highly obscured HMXB IGR J16318-4848 with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving p…
▽ More
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer; SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and HXI) aboard Hitomi. Even though photon counts are limited due to unintended off-axis pointing, the SXS spectrum resolves Fe K{α_1} and K{α_2} lines and puts strong constraints on the line centroid and width. The line width corresponds to the velocity of 160^{+300}_{-70} km s^{-1}. This represents the most accurate, and smallest, width measurement of this line made so far from any X-ray binary, much less than the Doppler broadening and shift expected from speeds which are characteristic of similar systems. Combined with the K-shell edge energy measured by the SXI and HXI spectra, the ionization state of Fe is estimated to be in the range of Fe I--IV. Considering the estimated ionization parameter and the distance between the X-ray source and the absorber, the density and thickness of the materials are estimated. The extraordinarily strong absorption and the absence of a Compton shoulder component is confirmed. These characteristics suggest reprocessing materials which are distributed in a narrow solid angle or scattering primarily with warm free electrons or neutral hydrogen.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Hitomi Observation of Radio Galaxy NGC 1275: The First X-ray Microcalorimeter Spectroscopy of Fe-Kα Line Emission from an Active Galactic Nucleus
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellit…
▽ More
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275 at the center of the Perseus cluster of galaxies. With the high energy resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the Fe-Kα line with ~5.4 σ significance. The velocity width is constrained to be 500-1600 km s$^{-1}$ (FWHM for Gaussian models) at 90% confidence. The SXS also constrains the continuum level from the NGC 1275 nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line. Because the velocity width is narrower than that of broad Hα line of ~2750 km s$^{-1}$, we can exclude a large contribution to the line flux from the accretion disk and the broad line region. Furthermore, we performed pixel map analyses on the Hitomi/SXS data and image analyses on the Chandra archival data, and revealed that the Fe-Kα line comes from a region within ~1.6 kpc from the NGC 1275 core, where an active galactic nucleus emission dominates, rather than that from intracluster media. Therefore, we suggest that the source of the Fe-Kα line from NGC 1275 is likely a low-covering fraction molecular torus or a rotating molecular disk which probably extends from a pc to hundreds pc scale in the active galactic nucleus system.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
High-speed X-ray imaging spectroscopy system with Zynq SoC for solar observations
Authors:
Shin-nosuke Ishikawa,
Tadayuki Takahashi,
Shin Watanabe,
Noriyuki Narukage,
Satoshi Miyazaki,
Tadashi Orita,
Shin'ichiro Takeda,
Masaharu Nomahi,
Iwao Fujishiro,
Fumio Hodoshima
Abstract:
We have developed a system combining a back-illuminated Complementary-Metal-Oxide-Semiconductor (CMOS) imaging sensor and Xilinx Zynq System-on-Chip (SoC) device for a soft X-ray (0.5-10 keV) imaging spectroscopy observation of the Sun to investigate the dynamics of the solar corona. Because typical timescales of energy release phenomena in the corona span a few minutes at most, we aim to obtain t…
▽ More
We have developed a system combining a back-illuminated Complementary-Metal-Oxide-Semiconductor (CMOS) imaging sensor and Xilinx Zynq System-on-Chip (SoC) device for a soft X-ray (0.5-10 keV) imaging spectroscopy observation of the Sun to investigate the dynamics of the solar corona. Because typical timescales of energy release phenomena in the corona span a few minutes at most, we aim to obtain the corresponding energy spectra and derive the physical parameters, i.e., temperature and emission measure, every few tens of seconds or less for future solar X-ray observations. An X-ray photon-counting technique, with a frame rate of a few hundred frames per second or more, can achieve such results. We used the Zynq SoC device to achieve the requirements. Zynq contains an ARM processor core, which is also known as the Processing System (PS) part, and a Programmable Logic (PL) part in a single chip. We use the PL and PS to control the sensor and seamless recording of data to a storage system, respectively. We aim to use the system for the third flight of the Focusing Optics Solar X-ray Imager (FOXSI-3) sounding rocket experiment for the first photon-counting X-ray imaging and spectroscopy of the Sun.
△ Less
Submitted 12 November, 2017;
originally announced November 2017.
-
Atmospheric gas dynamics in the Perseus cluster observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Rebecca E. A. Canning,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done
, et al. (173 additional authors not shown)
Abstract:
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the…
▽ More
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the hot gas is remarkably low and mostly uniform. The velocity dispersion reaches maxima of approximately 200~km~s$^{-1}$ toward the central active galactic nucleus (AGN) and toward the AGN inflated north-western `ghost' bubble. Elsewhere within the observed region, the velocity dispersion appears constant around 100~km~s$^{-1}$. We also detect a velocity gradient with a 100~km~s$^{-1}$ amplitude across the cluster core, consistent with large-scale sloshing of the core gas. If the observed gas motions are isotropic, the kinetic pressure support is less than 10\% of the thermal pressure support in the cluster core. The well-resolved optically thin emission lines have Gaussian shapes, indicating that the turbulent driving scale is likely below 100~kpc, which is consistent with the size of the AGN jet inflated bubbles. We also report the first measurement of the ion temperature in the intracluster medium, which we find to be consistent with the electron temperature. In addition, we present a new measurement of the redshift to the brightest cluster galaxy NGC~1275.
△ Less
Submitted 1 November, 2017;
originally announced November 2017.
-
Measurements of resonant scattering in the Perseus cluster core with Hitomi SXS
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the ga…
▽ More
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the gas in the core of the Perseus cluster. Here, we show that when inferring physical properties from line emissivities in systems like Perseus, the resonant scattering (RS) effect should be taken into account. In the Hitomi waveband, RS mostly affects the FeXXV He$α$ line ($w$) - the strongest line in the spectrum. The flux measured by Hitomi in this line is suppressed by a factor ~1.3 in the inner ~30 kpc, compared to predictions for an optically thin plasma; the suppression decreases with the distance from the center. The $w$ line also appears slightly broader than other lines from the same ion. The observed distortions of the $w$ line flux, shape and distance dependence are all consistent with the expected effect of the resonant scattering in the Perseus core. By measuring the ratio of fluxes in optically thick ($w$) and thin (FeXXV forbidden, He$β$, Ly$α$) lines, and comparing these ratios with predictions from Monte Carlo radiative transfer simulations, the velocities of gas motions have been obtained. The results are consistent with the direct measurements of gas velocities from line broadening described elsewhere in this series, although the systematic and statistical uncertainties remain significant. Further improvements in the predictions of line emissivities in plasma models, and deeper observations with future X-ray missions will enable RS measurements to provide powerful constraints on the amplitude and anisotropy of clusters gas motions.
△ Less
Submitted 11 October, 2017;
originally announced October 2017.
-
Hitomi X-ray studies of Giant Radio Pulses from the Crab pulsar
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (179 additional authors not shown)
Abstract:
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance…
▽ More
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1,000 and 100 GRPs were simultaneously observed at the main and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main or inter-pulse phases.All variations are within the 2 sigma fluctuations of the X-ray fluxes at the pulse peaks, and the 3 sigma upper limits of variations of main- or inter- pulse GRPs are 22\% or 80\% of the peak flux in a 0.20 phase width, respectively, in the 2 -- 300 keV band.The values become 25\% or 110\% for main or inter-pulse GRPs, respectively, when the phase width is restricted into the 0.03 phase.Among the upper limits from the Hitomi satellite, those in the 4.5-10 keV and the 70-300 keV are obtained for the first time, and those in other bands are consistent with previous reports.Numerically, the upper limits of main- and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) $\times 10^{-11}$ erg cm$^{-2}$, respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere and the number of photon-emitting particles temporally increases.However, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a $>0.02$\% brightening of the pulse-peak flux under such conditions.
△ Less
Submitted 7 August, 2017; v1 submitted 27 July, 2017;
originally announced July 2017.
-
Search for Thermal X-ray Features from the Crab nebula with Hitomi Soft X-ray Spectrometer
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture…
▽ More
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture (EC) explosion with a lower explosion energy by an order of magnitude than Fe-core collapse SNe. In the X-rays, imaging searches were performed for the plasma emission from the shell in the Crab outskirts to set a stringent upper limit to the X-ray emitting mass. However, the extreme brightness of the source hampers access to its vicinity. We thus employed spectroscopic technique using the X-ray micro-calorimeter onboard the Hitomi satellite. By exploiting its superb energy resolution, we set an upper limit for emission or absorption features from yet undetected thermal plasma in the 2-12 keV range. We also re-evaluated the existing Chandra and XMM-Newton data. By assembling these results, a new upper limit was obtained for the X-ray plasma mass of <~ 1Mo for a wide range of assumed shell radius, size, and plasma temperature both in and out of the collisional equilibrium. To compare with the observation, we further performed hydrodynamic simulations of the Crab SNR for two SN models (Fe-core versus EC) under two SN environments (uniform ISM versus progenitor wind). We found that the observed mass limit can be compatible with both SN models if the SN environment has a low density of <~ 0.03 cm-3 (Fe core) or <~ 0.1 cm-3 (EC) for the uniform density, or a progenitor wind density somewhat less than that provided by a mass loss rate of 10-5 Mo yr-1 at 20 km s-1 for the wind environment.
△ Less
Submitted 4 July, 2017; v1 submitted 30 June, 2017;
originally announced July 2017.
-
Study of the Polarimetric Performance of a Si/CdTe Semiconductor Compton Camera for the Hitomi Satellite
Authors:
Junichiro Katsuta,
Ikumi Edahiro,
Shin Watanabe,
Hirokazu Odaka,
Yusuke Uchida,
Nagomi Uchida,
Tsunefumi Mizuno,
Yasushi Fukazawa,
Katsuhiro Hayashi,
Sho Habata,
Yuto Ichinohe,
Takao Kitaguchi,
Masanori Ohno,
Masayuki Ohta,
Hiromitsu Takahashi,
Tadayuki Takahashi,
Shin'ichiro Takeda,
Hiroyasu Tajima,
Takayuki Yuasa,
Masayoshi Itou
Abstract:
Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be an excellent polarimeter, as well as a highly sensitive spectrometer due to its good angular coverage and resolution for Compton scattering. A beam test of the…
▽ More
Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be an excellent polarimeter, as well as a highly sensitive spectrometer due to its good angular coverage and resolution for Compton scattering. A beam test of the final-prototype for the SGD Compton camera was conducted to demonstrate its polarimetric capability and to verify and calibrate the Monte Carlo simulation of the instrument. The modulation factor of the SGD prototype camera, evaluated for the inner and outer parts of the CdTe sensors as absorbers, was measured to be 0.649--0.701 (inner part) and 0.637--0.653 (outer part) at 122.2 keV and 0.610--0.651 (inner part) and 0.564--0.592 (outer part) at 194.5 keV at varying polarization angles with respect to the detector. This indicates that the relative systematic uncertainty of the modulation factor is as small as ~3%.
△ Less
Submitted 18 October, 2016;
originally announced October 2016.
-
Hitomi constraints on the 3.5 keV line in the Perseus galaxy cluster
Authors:
Hitomi Collaboration,
Felix A. Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Keith A. Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger D. Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (193 additional authors not shown)
Abstract:
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-New…
▽ More
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-Newton signal from the large cluster sample under the dark matter decay scenario is too faint to be detectable in the Hitomi data. However, the previously reported 3.5 keV flux from Perseus was anomalously high compared to the sample-based prediction. We find no unidentified line at the reported high flux level. Taking into account the XMM measurement uncertainties for this region, the inconsistency with Hitomi is at a 99% significance for a broad dark-matter line and at 99.7% for a narrow line from the gas. We do not find anomalously high fluxes of the nearby faint K line or the Ar satellite line that were proposed as explanations for the earlier 3.5 keV detections. We do find a hint of a broad excess near the energies of high-n transitions of Sxvi (E=3.44 keV rest-frame) -- a possible signature of charge exchange in the molecular nebula and another proposed explanation for the unidentified line. While its energy is consistent with XMM pn detections, it is unlikely to explain the MOS signal. A confirmation of this interesting feature has to wait for a more sensitive observation with a future calorimeter experiment.
△ Less
Submitted 27 February, 2017; v1 submitted 25 July, 2016;
originally announced July 2016.
-
The Quiescent Intracluster Medium in the Core of the Perseus Cluster
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall Bautz,
Roger Blandford,
Laura Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward Cackett,
Maria Chernyakova,
Meng Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done
, et al. (191 additional authors not shown)
Abstract:
Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injectio…
▽ More
Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injection by the central supermassive black hole and the use of hydrostatic equilibrium for the determination of cluster masses. X-rays from the core of the Perseus cluster are emitted by the 50 million K diffuse hot plasma filling its gravitational potential well. The Active Galactic Nucleus of the central galaxy NGC1275 is pum** jetted energy into the surrounding intracluster medium, creating buoyant bubbles filled with relativistic plasma. These likely induce motions in the intracluster medium and heat the inner gas preventing runaway radiative cooling; a process known as Active Galactic Nucleus Feedback. Here we report on Hitomi X-ray observations of the Perseus cluster core, which reveal a remarkably quiescent atmosphere where the gas has a line-of-sight velocity dispersion of 164+/-10 km/s in a region 30-60 kpc from the central nucleus. A gradient in the line-of-sight velocity of 150+/-70 km/s is found across the 60 kpc image of the cluster core. Turbulent pressure support in the gas is 4% or less of the thermodynamic pressure, with large scale shear at most doubling that estimate. We infer that total cluster masses determined from hydrostatic equilibrium in the central regions need little correction for turbulent pressure.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Fine-pitch CdTe detector for hard X-ray imaging and spectroscopy of the Sun with the FOXSI rocket experiment
Authors:
S. Ishikawa,
M. Katsuragawa,
S. Watanabe,
Y. Uchida,
S. Takeda,
T. Takahashi,
S. Saito,
L. Glesener,
J. C. Buitrago-Casas,
S. Krucker,
S. Christe
Abstract:
We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4-15 keV using the new technique of HXR focusing optics. The focal plane detector requires < 100 um position resolu…
▽ More
We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4-15 keV using the new technique of HXR focusing optics. The focal plane detector requires < 100 um position resolution (to take advantage of the angular resolution of the optics) and about 1 keV energy resolution (FWHM) for spectroscopy down to 4 keV, with moderate cooling (> -30 C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66 at 15 keV for the silicon detectors) and position resolution of 75 um for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 um and almost 100 % efficiency for the FOXSI energy range. The sensitive area is 7.67 mm x 7.67 mm, corresponding to the field of view of 791'' x 791''. An energy resolution of about 1 keV (FWHM) and low energy threshold of 4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on December 11, 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.
△ Less
Submitted 13 June, 2016;
originally announced June 2016.
-
Suzaku observations of the hard X-ray spectrum of Vela Jr
Authors:
Sawako Takeda,
Aya Bamba,
Yukikatsu Terada,
Makoto S. Tashiro,
Satoru Katsuda,
Ryo Yamazaki,
Yutaka Ohira,
Wataru Iwakiri
Abstract:
We report the results of Suzaku observations of the young supernova remnant, Vela Jr.\ (RX J0852.0$-$4622), which is known to emit synchrotron X-rays, as well as TeV gamma-rays. Utilizing 39 Suzaku map** observation data from Vela Jr., a significant hard X-ray emission is detected with the hard X-ray detector (HXD) from the north-west TeV-emitting region. The X-ray spectrum is well reproduced by…
▽ More
We report the results of Suzaku observations of the young supernova remnant, Vela Jr.\ (RX J0852.0$-$4622), which is known to emit synchrotron X-rays, as well as TeV gamma-rays. Utilizing 39 Suzaku map** observation data from Vela Jr., a significant hard X-ray emission is detected with the hard X-ray detector (HXD) from the north-west TeV-emitting region. The X-ray spectrum is well reproduced by a single power-law model with the photon index of 3.15$^{+1.18}_{-1.14}$ in the 12--22 keV band. Compiling this with the soft X-ray spectrum simultaneously observed with the X-ray imaging spectrometer (XIS) onboard Suzaku, we find that the wide-band X-ray spectrum in the 2--22 keV band is reproduced with a single power-law or concave broken power-law model, which are statistically consistent with each other. Whichever the model of a single or broken power-law is appropriate, clearly the spectrum has no rolloff structure. Applying this result to the method introduced in \citet{yama2014}, we find that one-zone synchrotron model with electron spectrum having a power-law plus exponential cutoff may not be applicable to Vela Jr.
△ Less
Submitted 7 March, 2016;
originally announced March 2016.
-
The first demonstration of the concept of "narrow-FOV Si/CdTe semiconductor Compton camera"
Authors:
Yuto Ichinohe,
Yuusuke Uchida,
Shin Watanabe,
Ikumi Edahiro,
Katsuhiro Hayashi,
Takafumi Kawano,
Masanori Ohno,
Masayuki Ohta,
Shin'ichiro Takeda,
Yasushi Fukazawa,
Miho Katsuragawa,
Kazuhiro Nakazawa,
Hirokazu Odaka,
Hiroyasu Tajima,
Hiromitsu Takahashi,
Tadayuki Takahashi,
Takayuki Yuasa
Abstract:
The Soft Gamma-ray Detector (SGD), to be deployed onboard the {\it ASTRO-H} satellite, has been developed to provide the highest sensitivity observations of celestial sources in the energy band of 60-600~keV by employing a detector concept which uses a Compton camera whose field-of-view is restricted by a BGO shield to a few degree (narrow-FOV Compton camera). In this concept, the background from…
▽ More
The Soft Gamma-ray Detector (SGD), to be deployed onboard the {\it ASTRO-H} satellite, has been developed to provide the highest sensitivity observations of celestial sources in the energy band of 60-600~keV by employing a detector concept which uses a Compton camera whose field-of-view is restricted by a BGO shield to a few degree (narrow-FOV Compton camera). In this concept, the background from outside the FOV can be heavily suppressed by constraining the incident direction of the gamma ray reconstructed by the Compton camera to be consistent with the narrow FOV. We, for the first time, demonstrate the validity of the concept using background data taken during the thermal vacuum test and the low-temperature environment test of the flight model of SGD on ground. We show that the measured background level is suppressed to less than 10\% by combining the event rejection using the anti-coincidence trigger of the active BGO shield and by using Compton event reconstruction techniques. More than 75\% of the signals from the field-of-view are retained against the background rejection, which clearly demonstrates the improvement of signal-to-noise ratio. The estimated effective area of 22.8~cm$^2$ meets the mission requirement even though not all of the operational parameters of the instrument have been fully optimized yet.
△ Less
Submitted 25 September, 2015;
originally announced September 2015.
-
The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
Authors:
Shin Watanabe,
Hiroyasu Tajima,
Yasushi Fukazawa,
Yuto Ichinohe,
Shin'ichiro Takeda,
Teruaki Enoto,
Taro Fukuyama,
Shunya Furui,
Kei Genba,
Kouichi Hagino,
Astushi Harayama,
Yoshikatsu Kuroda,
Daisuke Matsuura,
Ryo Nakamura,
Kazuhiro Nakazawa,
Hirofumi Noda,
Hirokazu Odaka,
Masayuki Ohta,
Mitsunobu Onishi,
Shinya Saito,
Goro Sato,
Tamotsu Sato,
Tadayuki Takahashi,
Takaaki Tanaka,
Atsushi Togo
, et al. (1 additional authors not shown)
Abstract:
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector sys…
▽ More
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
△ Less
Submitted 2 September, 2015;
originally announced September 2015.
-
Prospect for Future MeV Gamma-ray Active Galactic Nuclei Population Studies
Authors:
Yoshiyuki Inoue,
Yasuyuki T. Tanaka,
Hirokazu Odaka,
Atsushi Takada,
Yuto Ichinohe,
Shinya Saito,
Shin'ichiro Takeda,
Tadayuki Takahashi
Abstract:
While the X-ray, GeV gamma-ray, and TeV gamma-ray skies have been extensively studied, the MeV gamma-ray sky is not well investigated after the Imaging Compton Telescope (COMPTEL) scanned the sky about two decades ago. In this paper, we investigate prospects for active galactic nuclei population studies with future MeV gamma-ray missions using recent spectral models and luminosity functions of Sey…
▽ More
While the X-ray, GeV gamma-ray, and TeV gamma-ray skies have been extensively studied, the MeV gamma-ray sky is not well investigated after the Imaging Compton Telescope (COMPTEL) scanned the sky about two decades ago. In this paper, we investigate prospects for active galactic nuclei population studies with future MeV gamma-ray missions using recent spectral models and luminosity functions of Seyfert and flat spectrum radio quasars (FSRQs). Both of them are plausible candidates as the origins of the cosmic MeV gamma-ray background. If the cosmic MeV gamma-ray background radiation is dominated by non-thermal emission from Seyferts, the sensitivity of 10^-12 erg cm^-2 s^-1 is required to detect several hundred Seyferts in the entire sky. If FSRQs make up the cosmic MeV gamma-ray background, the sensitivity of ~4 x 10^-12 erg cm^-2 s^-1 is required to detect several hundred FSRQs following the recent FSRQ X-ray luminosity function. However, based on the latest FSRQ gamma-ray luminosity function, with which FSRQs can explain up to ~30% of the MeV background, we can expect several hundred FSRQs even with the sensitivity of 10^-11 erg cm^-2 s^-1 which is almost the same as the sensitivity goal of the next generation MeV telescopes.
△ Less
Submitted 21 April, 2015; v1 submitted 10 March, 2015;
originally announced March 2015.
-
The ASTRO-H X-ray Astronomy Satellite
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Makoto Asai,
Marc Audard,
Hisamitsu Awaki,
Philipp Azzarello,
Chris Baluta,
Aya Bamba,
Nobutaka Bando,
Marshall Bautz,
Thomas Bialas,
Roger Blandford,
Kevin Boyce,
Laura Brenneman,
Greg Brown,
Edward Cackett,
Edgar Canavan
, et al. (228 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-ra…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. The simultaneous broad band pass, coupled with the high spectral resolution of Delta E < 7 eV of the micro-calorimeter, will enable a wide variety of important science themes to be pursued. ASTRO-H is expected to provide breakthrough results in scientific areas as diverse as the large-scale structure of the Universe and its evolution, the behavior of matter in the gravitational strong field regime, the physical conditions in sites of cosmic-ray acceleration, and the distribution of dark matter in galaxy clusters at different redshifts.
△ Less
Submitted 3 December, 2014;
originally announced December 2014.
-
Bin Mode Estimation Methods for Compton Camera Imaging
Authors:
Shiro Ikeda,
Hirokazu Odaka,
Makoto Uemura,
Tadayuki Takahashi,
Shin Watanabe,
Shin'ichiro Takeda
Abstract:
We study the image reconstruction problem of a Compton camera which consists of semiconductor detectors. The image reconstruction is formulated as a statistical estimation problem. We employ a bin-mode estimation (BME) and extend an existing framework to a Compton camera with multiple scatterers and absorbers. Two estimation algorithms are proposed: an accelerated EM algorithm for the maximum like…
▽ More
We study the image reconstruction problem of a Compton camera which consists of semiconductor detectors. The image reconstruction is formulated as a statistical estimation problem. We employ a bin-mode estimation (BME) and extend an existing framework to a Compton camera with multiple scatterers and absorbers. Two estimation algorithms are proposed: an accelerated EM algorithm for the maximum likelihood estimation (MLE) and a modified EM algorithm for the maximum a posteriori (MAP) estimation. Numerical simulations demonstrate the potential of the proposed methods.
△ Less
Submitted 1 May, 2014; v1 submitted 16 December, 2013;
originally announced December 2013.
-
The ASTRO-H X-ray Observatory
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Henri AartsFelix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Makoto Asai,
Marc Audard,
Hisamitsu Awaki,
Philipp Azzarello,
Chris Baluta,
Aya Bamba,
Nobutaka Bando,
Mark Bautz,
Roger Blandford,
Kevin Boyce,
Greg Brown,
Ed Cackett,
Maria Chernyakova,
Paolo Coppi,
Elisa Costantini
, et al. (198 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer s…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.
△ Less
Submitted 16 October, 2012;
originally announced October 2012.
-
High energy resolution hard X-ray and gamma-ray imagers using CdTe diode devices
Authors:
Shin Watanabe,
Shin-nosuke Ishikawa,
Hiroyuki Aono,
Shin'ichiro Takeda,
Hirokazu Odaka,
Motohide Kokubun,
Tadayuki Takahashi,
Kazuhiro Nakazawa,
Hiroyasu Tajima,
Mitsunobu Onishi,
Yoshikatsu Kuroda
Abstract:
We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segment…
▽ More
We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes were recently established, followed by a CdTe device in which the Al anodes could be segmented into strips. We developed CdTe double-sided strip devices having Pt cathode strips and Al anode strips, and assembled prototype CdTe DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the strips are processed with analog ASICs (application specific integrated circuits). We have successfully performed gamma-ray imaging spectroscopy with a position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full width at half maximum) was obtained at 59.54 keV. Moreover, the possibility of improved spectral performance by utilizing the energy information of both side strips was demonstrated. We designed and fabricated a new analog ASIC, VA32TA6, for the readout of semiconductor detectors, which is also suitable for DSDs. A new feature of the ASIC is its internal ADC function. We confirmed this function and good noise performance that reaches an equivalent noise charge of 110 e- under the condition of 3-4 pF input capacitance.
△ Less
Submitted 3 November, 2008;
originally announced November 2008.
-
In-Orbit Performance of the Hard X-ray Detector on board Suzaku
Authors:
M. Kokubun,
K. Makishima,
T. Takahashi,
T. Murakami,
M. Tashiro,
Y. Fukazawa,
T. Kamae,
G. M. Madejski,
K. Nakazawa,
K. Yamaoka,
Y. Terada,
D. Yonetoku,
S. Watanabe,
T. Tamagawa,
T. Mizuno,
A. Kubota,
N. Isobe,
I. Takahashi,
G. Sato,
H. Takahashi,
S. Hong,
M. Kawaharada,
N. Kawano,
T. Mitani,
M. Murashima
, et al. (32 additional authors not shown)
Abstract:
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of P…
▽ More
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
Hard X-ray Detector (HXD) on Board Suzaku
Authors:
T. Takahashi,
K. Abe,
M. Endo,
Y. Endo,
Y. Ezoe,
Y. Fukazawa,
M. Hamaya,
S. Hirakuri,
S. Hong,
M. Horii,
H. Inoue,
N. Isobe,
T. Itoh,
N. Iyomoto,
T. Kamae,
D. Kasama,
J. Kataoka,
H. Kato,
M. Kawaharada,
N. Kawano,
K. Kawashima,
S. Kawasoe,
T. Kishishita,
T. Kitaguchi,
Y. Kobayashi
, et al. (44 additional authors not shown)
Abstract:
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the…
▽ More
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
Results of a Si/CdTe Compton Telescope
Authors:
Kousuke Oonuki,
Takaaki Tanaka,
Shin Watanabe,
Shin'ichiro Takeda,
Kazuhiro Nakazawa,
Takefumi Mitani,
Tadayuki Takahashi,
Hiroyasu Tajima,
Yasushi Fukazawa,
Masaharu Nomachi
Abstract:
We have been develo** a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60 keV. For energies above several hundred keV, the higher efficiency of CdTe semiconductor in comparison with Si is expected to play an important role as an ab…
▽ More
We have been develo** a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60 keV. For energies above several hundred keV, the higher efficiency of CdTe semiconductor in comparison with Si is expected to play an important role as an absorber and a scatterer. In order to demonstrate the spectral and imaging capability of a CdTe-based Compton Telescope, we have developed a Compton telescope consisting of a stack of CdTe pixel detectors as a small scale prototype. With this prototype, we succeeded in reconstructing images and spectra by solving the Compton equation from 122 keV to 662 keV. The energy resolution (FWHM) of reconstructed spectra is 7.3 keV at 511 keV and 3.1 keV at 122 keV, respectively. The angular resolution obtained at 511 keV is measured to be 12.2 degree (FWHM).
△ Less
Submitted 20 September, 2005; v1 submitted 16 September, 2005;