-
The First GECAM Observation Results on Terrestrial Gamma-ray Flashes and Terrestrial Electron Beams
Authors:
Y. Zhao,
J. C. Liu,
S. L. Xiong,
W. C. Xue,
Q. B. Yi,
G. P. Lu,
W. Xu,
F. C. Lyu,
J. C. Sun,
W. X. Peng,
C. Zheng,
Y. Q. Zhang,
C. Cai,
S. Xiao,
S. L. Xie,
C. W. Wang,
W. J. Tan,
Z. H. An,
G. Chen,
Y. Q. Du,
Y. Huang,
M. Gao,
K. Gong,
D. Y. Guo,
J. J. He
, et al. (37 additional authors not shown)
Abstract:
Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a space-borne instrument dedicated to monitoring high-energy transients, including Terrestrial Gamma-ray Flashes (TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB-like events are identified during an effe…
▽ More
Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a space-borne instrument dedicated to monitoring high-energy transients, including Terrestrial Gamma-ray Flashes (TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB-like events are identified during an effective observation time of $\sim$9 months. We show that, with gamma-ray and charged particle detectors, GECAM can effectively identify and distinguish TGFs and TEBs, and measure their temporal and spectral properties in detail. A very high TGF-lightning association rate of $\sim$80\% is obtained between GECAM and GLD360 in east Asia region.
△ Less
Submitted 17 June, 2023;
originally announced June 2023.
-
The Design and Performance of Charged Particle Detector onboard the GECAM Mission
Authors:
Y. B. Xu,
X. L. Sun,
S. Yang,
X. Q. Li,
W. X. Peng,
K. Gong,
X. H. Liang,
Y. Q. Liu,
D. Y. Guo,
H. Wang,
C. Y. Li,
Z. H. An,
J. J. He,
X. J. Liu,
S. L. Xiong,
X. Y. Wen,
Fan Zhang,
D. L. Zhang,
X. Y. Zhao,
C. Y. Zhang,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du
, et al. (25 additional authors not shown)
Abstract:
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is us…
▽ More
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
GECAM detection of a bright type-I X-ray burst from 4U 0614+09: confirmation its spin frequency at 413 Hz
Authors:
Y. P. Chen,
J. Li,
S. L. Xiong,
L. Ji,
S. Zhang,
W. X. Peng,
R. Qiao,
X. Q. Li,
X. Y. Wen,
L. M. Song,
S. J. Zheng,
X. Y. Song,
X. Y. Zhao,
Y. Huang,
F. J. Lu,
S. N. Zhang,
S. Xiao,
C. Cai,
B. X. Zhang,
Z. H. An,
C. Chen,
G. Chen,
W. Chen,
G. Q. Dai,
Y. Q. Du
, et al. (65 additional authors not shown)
Abstract:
One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered w…
▽ More
One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered with \textit{Swift}/BAT \citep{Strohmayer2008}, and therefore confirms the spin frequency of this source. This burst is the brightest one in the normal bursts (except the superburst) ever detected from 4U~0614+09, which leads to an upper limit of distance estimation as 3.1 kpc. The folded light curve during the burst oscillation shows a multi-peak structure, which is the first case observed during a single burst oscillation in nonpulsating sources. The multi-peak profile could be due to additional harmonics of the burst oscillation, which is corresponding to several brighter/fainter spots at the stellar surface.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Ground-based calibration and characterization of GRD of GECAM: 8-160 keV
Authors:
J. J. He,
Z. H. An,
W. X. Peng,
X. Q. Li,
S. L. Xiong,
D. L. Zhang,
R. Qiao,
D. Y. Guo,
C. Cai,
Z. Chang,
C. Chen,
G. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
K. Gong,
D. J. Hou,
C. Y. Li,
G. Li,
L. Li,
M. S. Li,
X. B. Li,
X. F. Li,
Y. G. Li,
X. H. Liang
, et al. (36 additional authors not shown)
Abstract:
As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy ban…
▽ More
As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
The SiPM Array Data Acquisition Algorithm Applied to the GECAM Satellite Payload
Authors:
Y. Q. Liu,
K. Gong,
X. Q. Li,
X. Y. Wen,
Z. H. An,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Y. Li,
G. Li,
L. Li,
X. F. Li,
M. S. Li,
X. H. Liang,
X. J. Liu,
F. J. Lu,
H. Lu
, et al. (25 additional authors not shown)
Abstract:
The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array…
▽ More
The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array data is designed and implemented, and the output event packet is defined. Finally, the algorithm's efficacy for event acquisition is verified.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
The design and performance of GRD onboard the GECAM satellite
Authors:
Z. H. An,
X. L. Sun,
D. L. Zhang,
S. Yang,
X. Q. Li,
X. Y. Wen,
K. Gong,
X. H. Liang,
X. J. Liu,
Y. Q. Liu,
Y. G. Li,
S. L. Xiong,
Y. B. Xu,
Fan Zhang,
X. Y. Zhao,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
P. Y. Feng,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He
, et al. (26 additional authors not shown)
Abstract:
Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are…
▽ More
Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Dedicated SiPM array for GRD of GECAM
Authors:
D. L. Zhang,
X. L. Sun,
Z. H. An,
X. Q. Li,
X. Y. Wen,
K. Gong,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Y. Li,
G. Li,
L. Li,
X. F. Li,
M. S. Li,
X. H. Liang,
X. J. Liu,
Y. Q. Liu
, et al. (23 additional authors not shown)
Abstract:
The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of grav…
▽ More
The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
A low-energy sensitive compact gamma-ray detector based on LaBr3 and SiPM for GECAM
Authors:
P. Lv,
S. L. Xiong,
X. L. Sun,
J. G. Lv,
Y. G. Li
Abstract:
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) project is the planned Chinese space telescope for detecting the X and gamma-ray counterpart. It consists of two micro-satellites in low earth orbit with the advantages of instantaneous full-sky coverage, low energy threshold down to 6 keV and can be achieved within a short period and small budget. Due to the li…
▽ More
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) project is the planned Chinese space telescope for detecting the X and gamma-ray counterpart. It consists of two micro-satellites in low earth orbit with the advantages of instantaneous full-sky coverage, low energy threshold down to 6 keV and can be achieved within a short period and small budget. Due to the limitation of size, weight and power consumption of micro-satellites, silicon photomultipliers (SiPMs) are used to replace the photomultiplier tubes (PMTs) to assemble a novel gamma-ray detector. A prototype of a SiPM array with LaBr3 crystal is built and tested, and it shows a high detection efficiency (70% at 5.9 keV) and an acceptable uniformity. The low-energy X-ray of 5.9 keV can be detected by a simply readout circuit, and the energy resolution is 6.5% (FWHM) at 662 keV. The design and performance of the detector are discussed in detail in this paper.
△ Less
Submitted 13 September, 2018; v1 submitted 21 March, 2018;
originally announced March 2018.