-
Pushing high angular resolution and high contrast observations on the VLTI from Y to L band with the Asgard instrumental suite: integration status and plans
Authors:
Marc-Antoine Martinod,
Denis Defrère,
Michael J. Ireland,
Stefan Kraus,
Frantz Martinache,
Peter G. Tuthill,
Fatmé Allouche,
Emilie Bouzerand,
Julia Bryant,
Josh Carter,
Sorabh Chhabra,
Benjamin Courtney-Barrer,
Fred Crous,
Nick Cvetojevic,
Colin Dandumont,
Steve Ertel,
Tyler Gardner,
Germain Garreau,
Adrian M. Glauser,
Xavier Haubois,
Lucas Labadie,
Stéphane Lagarde,
Daniel Lancaster,
Romain Laugier,
Alexandra Mazzoli
, et al. (13 additional authors not shown)
Abstract:
ESO's Very Large Telescope Interferometer has a history of record-breaking discoveries in astrophysics and significant advances in instrumentation. The next leap forward is its new visitor instrument, called Asgard. It comprises four natively collaborating instruments: HEIMDALLR, an instrument performing both fringe tracking and stellar interferometry simultaneously with the same optics, operating…
▽ More
ESO's Very Large Telescope Interferometer has a history of record-breaking discoveries in astrophysics and significant advances in instrumentation. The next leap forward is its new visitor instrument, called Asgard. It comprises four natively collaborating instruments: HEIMDALLR, an instrument performing both fringe tracking and stellar interferometry simultaneously with the same optics, operating in the K band; Baldr, a Strehl optimizer in the H band; BIFROST, a spectroscopic combiner to study the formation processes and properties of stellar and planetary systems in the Y-J-H bands; and NOTT, a nulling interferometer dedicated to imaging nearby young planetary systems in the L band. The suite is in its integration phase in Europe and should be shipped to Paranal in 2025. In this article, we present details of the alignment and calibration unit, the observing modes, the integration plan, the software architecture, and the roadmap to completion of the project.
△ Less
Submitted 11 July, 2024;
originally announced July 2024.
-
Heimdallr and Solarstein: alignment, calibration, and correction in the Asgard suite at the VLTI
Authors:
Adam K. Taras,
J. Gordon Robertson,
Josh Carter,
Fred Crous,
Benjamin Courtney-Barrer,
Grace McGinness,
Michael Ireland,
Peter Tuthill
Abstract:
The Asgard instrument suite proposed for the ESO's Very Large Telescope Interferometer (VLTI) brings with it a new generation of instruments for spectroscopy and nulling. Asgard will enable investigations such as measurement of direct stellar masses for Galactic archaeology and direct detection of giant exoplanets to probe formation models using the first nulling interferometer in the southern hem…
▽ More
The Asgard instrument suite proposed for the ESO's Very Large Telescope Interferometer (VLTI) brings with it a new generation of instruments for spectroscopy and nulling. Asgard will enable investigations such as measurement of direct stellar masses for Galactic archaeology and direct detection of giant exoplanets to probe formation models using the first nulling interferometer in the southern hemisphere. We present the design and implementation of the Astralis-built Heimdallr, the beam combiner for fringe tracking and stellar interferometry in K band, as well as Solarstein, a novel implementation of a 4-beam telescope simulator for alignment and calibration. In this update, we verify that the Heimdallr design is sufficient to perform diffraction-limited beam combination. Furthermore, we demonstrate that Solarstein presents an interface comparable to the VLTI with co-phased, equal intensity beams, enabling alignment and calibration for all Asgard instruments. In doing so, we share techniques for aligning and implementing large instruments in bulk optics.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
GHOST Commissioning Science Results III: Characterizing an iron-poor damped Lyman $α$ system
Authors:
Trystyn A. M. Berg,
Christian R. Hayes,
Stefano Cristiani,
Alan McConnachie,
J. Gordon Robertson,
Federico Sestito,
Chris Simpson,
Fletcher Waller,
Timothy Chin,
Adam Densmore,
Ruben J. Diaz,
Michael L. Edgar,
Javier Fuentes Lettura,
Manuel Gómez-Jiménez,
Venu M. Kalari,
Jon Lawrence,
Steven Margheim,
John Pazder,
Roque Ruiz-Carmona,
Ricardo Salinas,
Karleyne M. G. Silva,
Katherine Silversides,
Kim A. Venn
Abstract:
The Gemini High-resolution Optical SpecTrograph (GHOST) is a new echelle spectrograph available on the Gemini-South telescope as of Semester 2024A. We present the first high resolution spectrum of the quasar J1449-1227 (redshift z_em=3.27) using data taken during the commissioning of GHOST. The observed quasar hosts an intervening iron-poor ([Fe/H] = -2.5) damped Lyman alpha (DLA) system at redshi…
▽ More
The Gemini High-resolution Optical SpecTrograph (GHOST) is a new echelle spectrograph available on the Gemini-South telescope as of Semester 2024A. We present the first high resolution spectrum of the quasar J1449-1227 (redshift z_em=3.27) using data taken during the commissioning of GHOST. The observed quasar hosts an intervening iron-poor ([Fe/H] = -2.5) damped Lyman alpha (DLA) system at redshift z=2.904. Taking advantage of the high spectral resolving power of GHOST (R~55000), we are able to accurately model the metal absorption lines of the metal-poor DLA and find a supersolar [Si/Fe], suggesting the DLA gas is in an early stage of chemical enrichment. Using simple ionization models, we find that the large range in the C IV/Si IV column density ratio of individual components within the DLA's high ionization absorption profile can be reproduced by several metal-poor Lyman limit systems surrounding the low-ionization gas of the DLA. It is possible that this metal-poor DLA resides within a complex system of metal-poor galaxies or filaments with inflowing gas. The high spectral resolution, wavelength coverage and sensitivity of GHOST makes it an ideal spectrograph for characterizing the chemistry and kinematics of quasar absorption lines.
△ Less
Submitted 18 April, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Heimdallr, Baldr and Solarstein: designing the next generation of VLTI instruments in the Asgard suite
Authors:
Adam K. Taras,
J. Gordon Robertson,
Fatme Allouche,
Benjamin Courtney-Barrer,
Josh Carter,
Fred Crous,
Nick Cvetojevic,
Michael Ireland,
Stephane Lagarde,
Frantz Martinache,
Grace McGinness,
Mamadou N'Diaye,
Sylvie Robbe-Dubois,
Peter Tuthill
Abstract:
High angular resolution imaging is an increasingly important capability in contemporary astrophysics. Of particular relevance to emerging fields such as the characterisation of exoplanetary systems, imaging at the required spatial scales and contrast levels results in forbidding challenges in the correction of atmospheric phase errors, which in turn drives demanding requirements for precise wavefr…
▽ More
High angular resolution imaging is an increasingly important capability in contemporary astrophysics. Of particular relevance to emerging fields such as the characterisation of exoplanetary systems, imaging at the required spatial scales and contrast levels results in forbidding challenges in the correction of atmospheric phase errors, which in turn drives demanding requirements for precise wavefront sensing. Asgard is the next-generation instrument suite at the European Southern Observatory's Very Large Telescope Interferometer (VLTI), targeting advances in sensitivity, spectral resolution and nulling interferometry. In this paper, we describe the requirements and designs of three core modules: Heimdallr, a beam combiner for fringe tracking, low order wavefront correction and visibility science; Baldr, a Zernike wavefront sensor to correct high order atmospheric aberrations; and Solarstein, an alignment and calibration unit. In addition, we draw generalisable insights for designing such system and discuss integration plans.
△ Less
Submitted 11 March, 2024; v1 submitted 6 March, 2024;
originally announced March 2024.
-
The Science Performance of the Gemini High Resolution Optical Spectrograph
Authors:
Alan W. McConnachie,
Christian R. Hayes,
J. Gordon Robertson,
John Pazder,
Michael Ireland,
Greg Burley,
Vladimir Churilov,
Jordan Lothrop,
Ross Zhelem,
Venu Kalari,
André Anthony,
Gabriella Baker,
Trystyn Berg,
Edward L. Chapin,
Timothy Chin,
Adam Densmore,
Ruben Diaz,
Jennifer Dunn,
Michael L. Edgar,
Tony Farrell,
Veronica Firpo,
Javier Fuentes,
Manuel Gomez-Jimenez,
Tim Hardy,
David Henderson
, et al. (24 additional authors not shown)
Abstract:
The Gemini High Resolution Optical Spectrograph (GHOST) is a fiber-fed spectrograph system on the Gemini South telescope that provides simultaneous wavelength coverage from 348 - 1061nm, and designed for optimal performance between 363 - 950nm. It can observe up to two objects simultaneously in a 7.5 arcmin diameter field of regard at R = 56,000 or a single object at R = 75,000. The spectral resol…
▽ More
The Gemini High Resolution Optical Spectrograph (GHOST) is a fiber-fed spectrograph system on the Gemini South telescope that provides simultaneous wavelength coverage from 348 - 1061nm, and designed for optimal performance between 363 - 950nm. It can observe up to two objects simultaneously in a 7.5 arcmin diameter field of regard at R = 56,000 or a single object at R = 75,000. The spectral resolution modes are obtained by using integral field units to image slice a 1.2" aperture by a factor of five in width using 19 fibers in the high resolution mode and by a factor of three in width using 7 fibers in the standard resolution mode. GHOST is equipped with hardware to allow for precision radial velocity measurements, expected to approach meters per second precision. Here, we describe the basic design and operational capabilities of GHOST, and proceed to derive and quantify the key aspects of its on-sky performance that are of most relevance to its science users.
△ Less
Submitted 14 January, 2024;
originally announced January 2024.
-
SPLUS J142445.34-254247.1: An R-Process Enhanced, Actinide-Boost, Extremely Metal-Poor star observed with GHOST
Authors:
Vinicius M. Placco,
Felipe Almeida-Fernandes,
Erika M. Holmbeck,
Ian U. Roederer,
Mohammad K. Mardini,
Christian R. Hayes,
Kim Venn,
Kristin Chiboucas,
Emily Deibert,
Roberto Gamen,
Jeong-Eun Heo,
Miji Jeong,
Venu Kalari,
Eder Martioli,
Siyi Xu,
Ruben Diaz,
Manuel Gomez-Jimenez,
David Henderson,
Pablo Prado,
Carlos Quiroz,
Roque Ruiz-Carmona,
Chris Simpson,
Cristian Urrutia,
Alan W. McConnachie,
John Pazder
, et al. (11 additional authors not shown)
Abstract:
We report on the chemo-dynamical analysis of SPLUS J142445.34-254247.1, an extremely metal-poor halo star enhanced in elements formed by the rapid neutron-capture process. This star was first selected as a metal-poor candidate from its narrow-band S-PLUS photometry and followed up spectroscopically in medium-resolution with Gemini South/GMOS, which confirmed its low-metallicity status. High-resolu…
▽ More
We report on the chemo-dynamical analysis of SPLUS J142445.34-254247.1, an extremely metal-poor halo star enhanced in elements formed by the rapid neutron-capture process. This star was first selected as a metal-poor candidate from its narrow-band S-PLUS photometry and followed up spectroscopically in medium-resolution with Gemini South/GMOS, which confirmed its low-metallicity status. High-resolution spectroscopy was gathered with GHOST at Gemini South, allowing for the determination of chemical abundances for 36 elements, from carbon to thorium. At [Fe/H]=-3.39, SPLUS J1424-2542 is one of the lowest metallicity stars with measured Th and has the highest logeps(Th/Eu) observed to date, making it part of the "actinide-boost" category of r-process enhanced stars. The analysis presented here suggests that the gas cloud from which SPLUS J1424-2542 was formed must have been enriched by at least two progenitor populations. The light-element (Z<=30) abundance pattern is consistent with the yields from a supernova explosion of metal-free stars with 11.3-13.4 Msun, and the heavy-element (Z>=38) abundance pattern can be reproduced by the yields from a neutron star merger (1.66Msun and 1.27Msun) event. A kinematical analysis also reveals that SPLUS J1424-2542 is a low-mass, old halo star with a likely in-situ origin, not associated with any known early merger events in the Milky Way.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.
-
Probing the early Milky Way with GHOST spectra of an extremely metal-poor star in the Galactic disk
Authors:
Anya Dovgal,
Kim A. Venn,
Federico Sestito,
Christian R. Hayes,
Alan W. McConnachie,
Julio F. Navarro,
Vinicius M. Placco,
Else Starkenburg,
Nicolas F. Martin,
John S. Pazder,
Kristin Chiboucas,
Emily Deibert,
Roberto Gamen,
Jeong-Eun Heo,
Venu M. Kalari,
Eder Martioli,
Siyi Xu,
Ruben Diaz,
Manuel Gomez-Jiminez,
David Henderson,
Pablo Prado,
Carlos Quiroz,
J. Gordon Robertson,
Roque Ruiz-Carmona,
Chris Simpson
, et al. (9 additional authors not shown)
Abstract:
Pristine_183.6849+04.8619 (P1836849) is an extremely metal-poor ([Fe/H]$=-3.3\pm0.1$) star on a prograde orbit confined to the Galactic disk. Such stars are rare and may have their origins in protogalactic fragments that formed the early Milky Way, in low mass satellites accreted later, or forming in situ in the Galactic plane. Here we present a chemo-dynamical analysis of the spectral features be…
▽ More
Pristine_183.6849+04.8619 (P1836849) is an extremely metal-poor ([Fe/H]$=-3.3\pm0.1$) star on a prograde orbit confined to the Galactic disk. Such stars are rare and may have their origins in protogalactic fragments that formed the early Milky Way, in low mass satellites accreted later, or forming in situ in the Galactic plane. Here we present a chemo-dynamical analysis of the spectral features between $3700-11000$Å from a high-resolution spectrum taken during Science Verification of the new Gemini High-resolution Optical SpecTrograph (GHOST). Spectral features for many chemical elements are analysed (Mg, Al, Si, Ca, Sc, Ti, Cr, Mn, Fe, Ni), and valuable upper limits are determined for others (C, Na, Sr, Ba). This main sequence star exhibits several rare chemical signatures, including (i) extremely low metallicity for a star in the Galactic disk, (ii) very low abundances of the light $α$-elements (Na, Mg, Si) compared to other metal-poor stars, and (iii) unusually large abundances of Cr and Mn, where [Cr, Mn/Fe]$_{\rm NLTE}>+0.5$. A comparison to theoretical yields from supernova models suggests that two low mass Population III objects (one 10 M$_\odot$ supernova and one 17 M$_\odot$ hypernova) can reproduce the abundance pattern well (reduced $χ^2<1$). When this star is compared to other extremely metal-poor stars on quasi-circular, prograde planar orbits, differences in both chemistry and kinematics imply there is little evidence for a common origin. The unique chemistry of P1836849 is discussed in terms of the earliest stages in the formation of the Milky Way.
△ Less
Submitted 26 November, 2023; v1 submitted 4 October, 2023;
originally announced October 2023.
-
Seeking celestial Positronium with an OH-suppressed diffraction-limited spectrograph
Authors:
J. Gordon Robertson,
Simon Ellis,
Qingshan Yu,
Joss Bland-Hawthorn,
Christopher Betters,
Martin Roth,
Sergio Leon-Saval
Abstract:
Celestially, Positronium (Ps), has only been observed through gamma-ray emission produced by its annihilation. However, in its triplet state, a Ps atom has a mean lifetime long enough for electronic transitions to occur between quantum states. This produces a recombination spectrum observable in principle at near IR wavelengths, where angular resolution greatly exceeding that of the gamma-ray obse…
▽ More
Celestially, Positronium (Ps), has only been observed through gamma-ray emission produced by its annihilation. However, in its triplet state, a Ps atom has a mean lifetime long enough for electronic transitions to occur between quantum states. This produces a recombination spectrum observable in principle at near IR wavelengths, where angular resolution greatly exceeding that of the gamma-ray observations is possible. However, the background in the NIR is dominated by extremely bright atmospheric hydroxyl (OH) emission lines. In this paper we present the design of a diffraction-limited spectroscopic system using novel photonic components - a photonic lantern, OH Fiber Bragg Grating filters, and a photonic TIGER 2-dimensional pseudo-slit - to observe the Ps Balmer alpha line at 1.3122 microns for the first time.
△ Less
Submitted 18 June, 2021;
originally announced June 2021.
-
Spectroscopic flat-fields can be used for precision CCD gain and noise tests
Authors:
J. Gordon Robertson
Abstract:
One of the basic parameters of a CCD camera is its gain, i.e. the number of detected electrons per output Analogue to Digital Unit (ADU). This is normally determined by finding the statistical variances from a series of flat-field exposures with nearly constant levels over substantial areas, and making use of the fact that photon (Poisson) noise has variance equal to the mean. However, when a CCD…
▽ More
One of the basic parameters of a CCD camera is its gain, i.e. the number of detected electrons per output Analogue to Digital Unit (ADU). This is normally determined by finding the statistical variances from a series of flat-field exposures with nearly constant levels over substantial areas, and making use of the fact that photon (Poisson) noise has variance equal to the mean. However, when a CCD has been installed in a spectroscopic instrument fed by numerous optical fibres, or with an echelle format, it is no longer possible to obtain illumination that is constant over large areas. Instead of making do with selected small areas, it is shown here that the wide variation of signal level in a spectroscopic `flat-field' can be used to obtain accurate values of the CCD gain, needing only a matched pair of exposures (that differ in their realisation of the noise). Once the gain is known, the CCD readout noise (in electrons) is easily found from a pair of bias frames. Spatial stability of the image in the two flat-fields is important, although correction of minor shifts is shown to be possible, at the expense of further analysis.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
Detector sampling of optical/IR spectra: how many pixels per FWHM?
Authors:
J. Gordon Robertson
Abstract:
Most optical and IR spectra are now acquired using detectors with finite-width pixels in a square array. This paper examines the effects of such pixellation, using computed simulations to illustrate the effects which most concern the astronomer end-user. Coarse sampling increases the random noise errors in wavelength by typically 10 - 20% at 2 pixels/FWHM, but with wide variation depending on the…
▽ More
Most optical and IR spectra are now acquired using detectors with finite-width pixels in a square array. This paper examines the effects of such pixellation, using computed simulations to illustrate the effects which most concern the astronomer end-user. Coarse sampling increases the random noise errors in wavelength by typically 10 - 20% at 2 pixels/FWHM, but with wide variation depending on the functional form of the instrumental Line Spread Function (LSF) and on the pixel phase. Line widths are even more strongly affected at low sampling frequencies. However, the noise in fitted peak amplitudes is minimally affected. Pixellation has a substantial but complex effect on the ability to see a relative minimum between two closely-spaced peaks (or relative maximum between two absorption lines). The consistent scale of resolving power presented by Robertson (2013) is extended to cover pixellated spectra. The systematic bias errors in wavelength introduced by pixellation are examined. While they may be negligible for smooth well-sampled symmetric LSFs, they are very sensitive to asymmetry and high spatial frequency substructure. The Modulation Transfer Function for sampled data is shown to give a useful indication of the extent of improperly sampled signal in an LSF. The common maxim that 2 pixels/FWHM is the Nyquist limit is incorrect and most LSFs will exhibit some aliasing at this sample frequency. While 2 pixels/FWHM is often an acceptable minimum for moderate signal/noise work, it is preferable to carry out simulations for any actual or proposed LSF to find the effects of sampling frequency. Where end-users have a choice of sampling frequencies, through on-chip binning and/or spectrograph configurations, the instrument user manual should include an examination of their effects. (Abridged)
△ Less
Submitted 20 July, 2017;
originally announced July 2017.
-
Alternative approach to precision narrow-angle astrometry for Antarctic long baseline interferometry
Authors:
Y. Kok,
M. J. Ireland,
A. C. Rizzuto,
P. G. Tuthill,
J. G. Robertson,
B. A. Warrington,
W. J. Tango
Abstract:
The conventional approach to high-precision narrow-angle astrometry using a long baseline interferometer is to directly measure the fringe packet separation of a target and a nearby reference star. This is done by means of a technique known as phase-referencing which requires a network of dual beam combiners and laser metrology systems. Using an alternative approach that does not rely on phase-ref…
▽ More
The conventional approach to high-precision narrow-angle astrometry using a long baseline interferometer is to directly measure the fringe packet separation of a target and a nearby reference star. This is done by means of a technique known as phase-referencing which requires a network of dual beam combiners and laser metrology systems. Using an alternative approach that does not rely on phase-referencing, the narrow-angle astrometry of several closed binary stars (with separation less than 2$"$), as described in this paper, was carried out by observing the fringe packet crossing event of the binary systems. Such an event occurs twice every sidereal day when the line joining the two stars of the binary is is perpendicular to the projected baseline of the interferometer. Observation of these events is well suited for an interferometer in Antarctica. Proof of concept observations were carried out at the Sydney University Stellar Interferometer (SUSI) with targets selected according to its geographical location. Narrow-angle astrometry using this indirect approach has achieved sub-100 micro-arcsecond precision.
△ Less
Submitted 22 August, 2014;
originally announced August 2014.
-
Phase-referenced Interferometry and Narrow-angle Astrometry with SUSI
Authors:
Y. Kok,
M. J. Ireland,
P. G. Tuthill,
J. G. Robertson,
B. A. Warrington,
A. C. Rizzuto,
W. J. Tango
Abstract:
The Sydney University Stellar Interferometer (SUSI) now incorporates a new beam combiner, called the Microarcsecond University of Sydney Companion Astrometry instrument (MUSCA), for the purpose of high precision differential astrometry of bright binary stars. Operating in the visible wavelength regime where photon-counting and post-processing fringe tracking is possible, MUSCA will be used in tand…
▽ More
The Sydney University Stellar Interferometer (SUSI) now incorporates a new beam combiner, called the Microarcsecond University of Sydney Companion Astrometry instrument (MUSCA), for the purpose of high precision differential astrometry of bright binary stars. Operating in the visible wavelength regime where photon-counting and post-processing fringe tracking is possible, MUSCA will be used in tandem with SUSI's primary beam combiner, Precision Astronomical Visible Observations (PAVO), to record high spatial resolution fringes and thereby measure the separation of fringe packets of binary stars. In its current phase of development, the dual beam combiner configuration has successfully demonstrated for the first time a dual-star phase-referencing operation in visible wavelengths. This paper describes the beam combiner optics and hardware, the network of metrology systems employed to measure every non-common path between the two beam combiners and also reports on a recent narrow-angle astrometric observation of $δ$ Orionis A (HR 1852) as the project enters its on-sky testing phase.
△ Less
Submitted 29 November, 2013;
originally announced November 2013.
-
Beating the classical limit: A diffraction-limited spectrograph for an arbitrary input beam
Authors:
Christopher H. Betters,
Sergio G. Leon-Saval,
J. Gordon Robertson,
Joss Bland-Hawthorn
Abstract:
We demonstrate a new approach to classical fiber-fed spectroscopy. Our method is to use a photonic lantern that converts an arbitrary (e.g. incoherent) input beam into N diffraction-limited outputs. For the highest throughput, the number of outputs must be matched to the total number of unpolarized spatial modes on input. This approach has many advantages: (i) after the lantern, the instrument is…
▽ More
We demonstrate a new approach to classical fiber-fed spectroscopy. Our method is to use a photonic lantern that converts an arbitrary (e.g. incoherent) input beam into N diffraction-limited outputs. For the highest throughput, the number of outputs must be matched to the total number of unpolarized spatial modes on input. This approach has many advantages: (i) after the lantern, the instrument is constructed from 'commercial off the shelf' components; (ii) the instrument is the minimum size and mass configuration at a fixed resolving power and spectral order (~shoebox sized in this case); (iii) the throughput is better than 60% (slit to detector, including detector QE of ~80%); (iv) the scattered light at the detector can be less than 0.1% (total power). Our first implementation operates over 1545-1555 nm (limited by the detector, a 640$\times$512 array with 20$μ$m pitch) with a spectral resolution of 0.055nm (R~30,000) using a 1$\times$7 (1 multi-mode input to 7 single-mode outputs) photonic lantern. This approach is a first step towards a fully integrated, multimode photonic microspectrograph.
△ Less
Submitted 17 October, 2013;
originally announced October 2013.
-
Long-Baseline Interferometric Multiplicity Survey of the Sco-Cen OB Association
Authors:
A. C. Rizzuto,
M. J. Ireland,
J. G. Robertson,
Y. Kok,
P. G. Tuthill,
B. A. Warrington,
X. Haubois,
W. J. Tango,
B. Norris,
T. ten Brummelaar,
A. L. Kraus,
A. Jacob,
C. Laliberte-Houdeville
Abstract:
We present the first multiplicity-dedicated long baseline optical interferometric survey of the Scorpius-Centaurus-Lupus-Crux association. We used the Sydney University Stellar Interferometer to undertake a survey for new companions to 58 Sco-Cen B- type stars and have detected 24 companions at separations ranging from 7-130mas, 14 of which are new detections. Furthermore, we use a Bayesian analys…
▽ More
We present the first multiplicity-dedicated long baseline optical interferometric survey of the Scorpius-Centaurus-Lupus-Crux association. We used the Sydney University Stellar Interferometer to undertake a survey for new companions to 58 Sco-Cen B- type stars and have detected 24 companions at separations ranging from 7-130mas, 14 of which are new detections. Furthermore, we use a Bayesian analysis and all available information in the literature to determine the multiplicity distribution of the 58 stars in our sample, showing that the companion frequency is F = 1.35 and the mass ratio distribution is best described as a power law with exponent equal to -0.46, agreeing with previous Sco-Cen high mass work and differing significantly from lower-mass stars in Tau-Aur. Based on our analysis, we estimate that among young B-type stars in moving groups, up to 23% are apparently single stars. This has strong implications for the understanding of high-mass star formation, which requires angular momentum dispersal through some mechanism such as formation of multiple systems.
△ Less
Submitted 15 September, 2013;
originally announced September 2013.
-
Quantifying resolving power in astronomical spectra
Authors:
J. Gordon Robertson
Abstract:
The spectral resolving power R = lambda / delta lambda is a key property of any spectrograph, but its definition is vague because the `smallest resolvable wavelength difference' delta lambda does not have a consistent definition. Often the FWHM is used, but this is not consistent when comparing the resolution of instruments with different forms of spectral line spread function. Here two methods fo…
▽ More
The spectral resolving power R = lambda / delta lambda is a key property of any spectrograph, but its definition is vague because the `smallest resolvable wavelength difference' delta lambda does not have a consistent definition. Often the FWHM is used, but this is not consistent when comparing the resolution of instruments with different forms of spectral line spread function. Here two methods for calculating resolving power on a consistent scale are given. The first is based on the principle that two spectral lines are just resolved when the mutual disturbance in fitting the fluxes of the lines reaches a threshold (here equal to that of sinc^2 profiles at the Rayleigh criterion). The second criterion assumes that two spectrographs have equal resolving powers if the wavelength error in fitting a narrow spectral line is the same in each case (given equal signal flux and noise power). The two criteria give similar results, and give rise to scaling factors which can be applied to bring resolving power calculated using the FWHM on to a consistent scale. The differences among commonly encountered Line Spread Functions are substantial, with a Lorentzian profile (as produced by an imaging Fabry-Perot interferometer) being a factor of two worse than the boxy profile from a projected circle (as produced by integration across the spatial dimension of a multi-mode fibre) when both have the same FWHM. The projected circle has a larger FWHM in comparison with its true resolution, so using FWHM to characterise the resolution of a spectrograph which is fed by multi-mode fibres significantly underestimates its true resolving power if it has small aberrations and a well-sampled profile.
△ Less
Submitted 4 August, 2013;
originally announced August 2013.
-
Optical Interferometry of early-type stars with PAVO@CHARA. I. Fundamental stellar properties
Authors:
V. Maestro,
X. Che,
D. Huber,
M. J. Ireland,
J. D. Monnier,
T. R. White,
Y. Kok,
J. G. Robertson,
G. H. Schaefer,
T. A. Ten Brummelaar,
P. G. Tuthill
Abstract:
We present interferometric observations of 7 main-sequence and 3 giant stars with spectral types from B2 to F6 using the PAVO beam combiner at the CHARA array. We have directly determined the angular diameters for these objects with an average precision of 2.3%. We have also computed bolometric fluxes using available photometry in the visible and infrared wavelengths, as well as space-based ultrav…
▽ More
We present interferometric observations of 7 main-sequence and 3 giant stars with spectral types from B2 to F6 using the PAVO beam combiner at the CHARA array. We have directly determined the angular diameters for these objects with an average precision of 2.3%. We have also computed bolometric fluxes using available photometry in the visible and infrared wavelengths, as well as space-based ultraviolet spectroscopy. Combined with precise \textit{Hipparcos} parallaxes, we have derived a set of fundamental stellar properties including linear radius, luminosity and effective temperature. Fitting the latter to computed isochrone models, we have inferred masses and ages of the stars. The effective temperatures obtained are in good agreement (at a 3% level) with nearly-independent temperature estimations from spectroscopy. They validate recent sixth-order polynomial (B-V)-$T_\mathrm{eff}$ empirical relations \citep{Boyajian2012a}, but suggest that a more conservative third-order solution \citep{vanBelle2009} could adequately describe the (V-K)-$T_\mathrm{eff}$ relation for main-sequence stars of spectral type A0 and later. Finally, we have compared mass values obtained combining surface gravity with inferred stellar radius (\textit{gravity mass}) and as a result of the comparison of computed luminosity and temperature values with stellar evolutionary models (\textit{isochrone mass}). The strong discrepancy between isochrone and gravity mass obtained for one of the observed stars, $γ$\,Lyr, suggests that determination of the stellar atmosphere parameters should be revised.
△ Less
Submitted 25 June, 2013;
originally announced June 2013.
-
A low cost scheme for high precision dual-wavelength laser metrology
Authors:
Yit** Kok,
Michael J. Ireland,
J. Gordon Robertson,
Peter G. Tuthill,
Benjamin A. Warrington,
William J. Tango
Abstract:
A novel method capable of delivering relative optical path length metrology with nanometer precision is demonstrated. Unlike conventional dual-wavelength metrology which employs heterodyne detection, the method developed in this work utilizes direct detection of interference fringes of two He-Ne lasers as well as a less precise stepper motor open-loop position control system to perform its measure…
▽ More
A novel method capable of delivering relative optical path length metrology with nanometer precision is demonstrated. Unlike conventional dual-wavelength metrology which employs heterodyne detection, the method developed in this work utilizes direct detection of interference fringes of two He-Ne lasers as well as a less precise stepper motor open-loop position control system to perform its measurement. Although the method may be applicable to a variety of circumstances, the specific application where this metrology is essential is in an astrometric optical long baseline stellar interferometer dedicated to precise measurement of stellar positions. In our example application of this metrology to a narrow-angle astrometric interferometer, measurement of nanometer precision could be achieved without frequency-stabilized lasers although the use of such lasers would extend the range of optical path length the metrology can accurately measure. Implementation of the method requires very little additional optics or electronics, thus minimizing cost and effort of implementation. Furthermore, the optical path traversed by the metrology lasers is identical with that of the starlight or science beams, even down to using the same photodetectors, thereby minimizing the non-common-path between metrology and science channels.
△ Less
Submitted 30 March, 2013;
originally announced April 2013.
-
Science and Technology Progress at the Sydney University Stellar Interferometer
Authors:
J. Gordon Robertson,
Michael J. Ireland,
William J. Tango,
Peter G. Tuthill,
Benjamin A. Warrington,
Yit** Kok,
Aaron C. Rizzuto,
Anthony Cheetham,
Andrew P. Jacob
Abstract:
This paper presents an overview of recent progress at the Sydney University Stellar Interferometer (SUSI). Development of the third-generation PAVO beam combiner has continued. The MUSCA beam combiner for high-precision differential astrometry using visible light phase referencing is under active development and will be the subject of a separate paper. Because SUSI was one of the pioneering interf…
▽ More
This paper presents an overview of recent progress at the Sydney University Stellar Interferometer (SUSI). Development of the third-generation PAVO beam combiner has continued. The MUSCA beam combiner for high-precision differential astrometry using visible light phase referencing is under active development and will be the subject of a separate paper. Because SUSI was one of the pioneering interferometric instruments, some of its original systems are old and have become difficult to maintain. We are undertaking a campaign of modernization of systems: (1) an upgrade of the Optical Path Length Compensator IR laser metrology counter electronics from a custom system which uses an obsolete single-board computer to a modern one based on an FPGA interfaced to a Linux computer - in addition to improving maintainability, this upgrade should allow smoother motion and higher carriage speeds; (2) the replacement of the aged single-board computer local controllers for the siderostats and the longitudinal dispersion compensator has been completed; (3) the large beam reducing telescope has been replaced with a pair of smaller units with separate accessible foci. Examples of scientific results are also included.
△ Less
Submitted 14 March, 2013;
originally announced March 2013.
-
Simulating a dual beam combiner at SUSI for narrow-angle astrometry
Authors:
Yit** Kok,
Vicente Maestro,
Michael J Ireland,
Peter G Tuthill,
J Gordon Robertson
Abstract:
The Sydney University Stellar Interferometer (SUSI) has two beam combiners, i.e. the Precision Astronomical Visible Observations (PAVO) and the Microarcsecond University of Sydney Companion Astrometry (MUSCA). The primary beam combiner, PAVO, can be operated independently and is typically used to measure properties of binary stars of less than 50 milliarc- sec (mas) separation and the angular diam…
▽ More
The Sydney University Stellar Interferometer (SUSI) has two beam combiners, i.e. the Precision Astronomical Visible Observations (PAVO) and the Microarcsecond University of Sydney Companion Astrometry (MUSCA). The primary beam combiner, PAVO, can be operated independently and is typically used to measure properties of binary stars of less than 50 milliarc- sec (mas) separation and the angular diameters of single stars. On the other hand, MUSCA was recently installed and must be used in tandem with the for- mer. It is dedicated for microarcsecond precision narrow-angle astrometry of close binary stars. The performance evaluation and development of the data reduction pipeline for the new setup was assisted by an in-house computer simulation tool developed for this and related purposes. This paper describes the framework of the simulation tool, simulations carried out to evaluate the performance of each beam combiner and the expected astrometric precision of the dual beam combiner setup, both at SUSI and possible future sites.
△ Less
Submitted 28 February, 2013;
originally announced February 2013.
-
Starlight Demonstration of the Dragonfly Instrument: an Integrated Photonic Pupil Remap** Interferometer for High Contrast Imaging
Authors:
N. Jovanovic,
P. G. Tuthill,
B. Norris,
S. Gross,
P. Stewart,
N. Charles,
S. Lacour,
M. Ams,
J. S. Lawrence,
A. Lehmann,
C. Niel,
J. G. Robertson,
G. D. Marshall,
M. Ireland,
A. Fuerbach,
M. J. Withford
Abstract:
In the two decades since the first extra-solar planet was discovered, the detection and characterization of extra-solar planets has become one of the key endeavors in all of modern science. Recently direct detection techniques such as interferometry or coronography have received growing attention because they reveal the population of exoplanets inaccessible to Doppler or transit techniques, and mo…
▽ More
In the two decades since the first extra-solar planet was discovered, the detection and characterization of extra-solar planets has become one of the key endeavors in all of modern science. Recently direct detection techniques such as interferometry or coronography have received growing attention because they reveal the population of exoplanets inaccessible to Doppler or transit techniques, and moreover they allow the faint signal from the planet itself to be investigated. Next-generation stellar interferometers are increasingly incorporating photonic technologies due to the increase in fidelity of the data generated. Here, we report the design, construction and commissioning of a new high contrast imager; the integrated pupil-remap** interferometer; an instrument we expect will find application in the detection of young faint companions in the nearest star-forming regions. The laboratory characterisation of the instrument demonstrated high visibility fringes on all interferometer baselines in addition to stable closure phase signals. We also report the first successful on-sky experiments with the prototype instrument at the 3.9-m Anglo-Australian Telescope. Performance metrics recovered were consistent with ideal device behaviour after accounting for expected levels of decoherence and signal loss from the uncompensated seeing. The prospect of complete Fourier-coverage coupled with the current performance metrics means that this photonically-enhanced instrument is well positioned to contribute to the science of high contrast companions.
△ Less
Submitted 1 October, 2012;
originally announced October 2012.
-
Compact high-resolution spectrographs for large and extremely large telescopes: using the diffraction limit
Authors:
J. Gordon Robertson,
Joss Bland-Hawthorn
Abstract:
As telescopes get larger, the size of a seeing-limited spectrograph for a given resolving power becomes larger also, and for ELTs the size will be so great that high resolution instruments of simple design will be infeasible. Solutions include adaptive optics (but not providing full correction for short wavelengths) or image slicers (which give feasible but still large instruments). Here we develo…
▽ More
As telescopes get larger, the size of a seeing-limited spectrograph for a given resolving power becomes larger also, and for ELTs the size will be so great that high resolution instruments of simple design will be infeasible. Solutions include adaptive optics (but not providing full correction for short wavelengths) or image slicers (which give feasible but still large instruments). Here we develop the solution proposed by Bland-Hawthorn and Horton: the use of diffraction-limited spectrographs which are compact even for high resolving power. Their use is made possible by the photonic lantern, which splits a multi-mode optical fiber into a number of single-mode fibers. We describe preliminary designs for such spectrographs, at a resolving power of R ~ 50,000. While they are small and use relatively simple optics, the challenges are to accommodate the longest possible fiber slit (hence maximum number of single-mode fibers in one spectrograph) and to accept the beam from each fiber at a focal ratio considerably faster than for most spectrograph collimators, while maintaining diffraction-limited imaging quality. It is possible to obtain excellent performance despite these challenges. We also briefly consider the number of such spectrographs required, which can be reduced by full or partial adaptive optics correction, and/or moving towards longer wavelengths.
△ Less
Submitted 23 August, 2012;
originally announced August 2012.
-
Multi-Dimensional Bayesian Membership Analysis of the Sco OB2 moving Group
Authors:
A. C. Rizzuto,
M. J. Ireland,
J. G. Robertson
Abstract:
We present a new high-mass membership of the nearby Sco OB2 association based on HIPPARCOS positions, proper motions and parallaxes and radial velocities taken from the Kharchenko et al. (2007) catalogue. The Bayesian membership selection method developed makes no distinction between subgroups of Sco OB2 and utilises linear models in calculation of membership probabilities. We select 436 members,…
▽ More
We present a new high-mass membership of the nearby Sco OB2 association based on HIPPARCOS positions, proper motions and parallaxes and radial velocities taken from the Kharchenko et al. (2007) catalogue. The Bayesian membership selection method developed makes no distinction between subgroups of Sco OB2 and utilises linear models in calculation of membership probabilities. We select 436 members, 88 of which are new members not included in previous membership selections. We include the classical non members Alpha-Cru and Beta-Cru as new members as well as the pre-main-sequence stars HIP 79080 and 79081. We also show that the association is well mixed over distances of 8 degrees on the sky, and hence no determination can be made as to the formation process of the entire association.
△ Less
Submitted 14 June, 2011;
originally announced June 2011.
-
The Angular Diameter and Fundamental Parameters of Sirius A
Authors:
J. Davis,
M. J. Ireland,
J. R. North,
J. G. Robertson,
W. J. Tango,
P. G. Tuthill
Abstract:
The Sydney University Stellar Interferometer (SUSI) has been used to make a new determination of the angular diameter of Sirius A. The observations were made at an effective wavelength of 694.1 nm and the new value for the limb-darkened angular diameter is 6.048 +/- 0.040mas (+/-0.66%). This new result is compared with previous measurements and is found to be in excellent agreement with a conventi…
▽ More
The Sydney University Stellar Interferometer (SUSI) has been used to make a new determination of the angular diameter of Sirius A. The observations were made at an effective wavelength of 694.1 nm and the new value for the limb-darkened angular diameter is 6.048 +/- 0.040mas (+/-0.66%). This new result is compared with previous measurements and is found to be in excellent agreement with a conventionally calibrated measurement made with the European Southern Observatory's Very Large Telescope Interferometer (VLTI) at 2.176 microns (but not with a second globally calibrated VLTI measurement). A weighted mean of the SUSI and first VLTI results gives the limb-darkened angular diameter of Sirius A as 6.041 +/- 0.017mas (+/-0.28%). Combination with the Hipparcos parallax gives the radius equal to 1.713 +/- 0.009R_sun. The bolometric flux has been determined from published photometry and spectrophotometry and, combined with the angular diameter, yields the emergent flux at the stellar surface equal to (5.32+/- 0.14)x10^8 Wm^-2 and the effective temperature equal to 9845 +/- 64 K. The luminosity is 24.7 +/- 0.7 L_sun.
△ Less
Submitted 18 October, 2010;
originally announced October 2010.
-
Alternative Adaptive Filter Structures for Improved Radio Frequency Interference Cancellation in Radio Astronomy
Authors:
D. A. Mitchell,
J. G. Robertson,
R. J. Sault
Abstract:
In radio astronomy, reference signals from auxiliary antennas that receive only the radio frequency interference (RFI) can be modified to model the RFI environment at the astronomy receivers. The RFI can then be canceled from the astronomy signal paths. However, astronomers typically only require signal statistics. If the RFI statistics are changing slowly, the cancellation can be applied to the s…
▽ More
In radio astronomy, reference signals from auxiliary antennas that receive only the radio frequency interference (RFI) can be modified to model the RFI environment at the astronomy receivers. The RFI can then be canceled from the astronomy signal paths. However, astronomers typically only require signal statistics. If the RFI statistics are changing slowly, the cancellation can be applied to the signal correlations at a much lower rate than is required for standard adaptive filters. In this paper we describe five canceler setups; precorrelation and postcorrelation cancelers that use one or two reference signals in different ways. The theoretical residual RFI and added noise levels are examined and are demonstrated using microwave television RFI at the Australia Telescope Compact Array. The RFI is attenuated to below the system noise, a reduction of at least 20 dB. While dual-reference cancelers add more reference noise than single-reference cancelers, this noise is zero-mean and only adds to the system noise, decreasing the sensitivity. The residual RFI that remains in the output of single-reference cancelers (but not dual-reference cancelers) sets a nonzero noise floor that does not act like random system noise and may limit the achievable sensitivity. Thus, dual-reference cancelers often result in superior cancellation. Dual-reference precorrelation cancelers require a double-canceler setup to be useful and to give equivalent results to dual-reference postcorrelation cancelers.
△ Less
Submitted 6 April, 2010;
originally announced April 2010.
-
Reference antenna techniques for canceling radio frequency interference due to moving sources
Authors:
D. A. Mitchell,
J. G. Robertson
Abstract:
We investigate characteristics of radio frequency interference (RFI) signals that can affect the excision potential of some interference mitigation algorithms. The techniques considered are those that modify signals from auxiliary reference antennas to model and cancel interference from an astronomical observation. These techniques can be applied in the time domain, where the RFI voltage is modele…
▽ More
We investigate characteristics of radio frequency interference (RFI) signals that can affect the excision potential of some interference mitigation algorithms. The techniques considered are those that modify signals from auxiliary reference antennas to model and cancel interference from an astronomical observation. These techniques can be applied in the time domain, where the RFI voltage is modeled and subtracted from the astronomy signal path (adaptive noise canceling), or they can be applied to the autocorrelated and cross-correlated voltage spectra in the frequency domain (postcorrelation canceling). For ideal receivers and a single, statistically stationary interfering signal, both precorrelation and postcorrelation filters can result in complete cancellation of the interference from the observation. The postcorrelation method has the advantage of being applied on tens or hundreds of millisecond timescales rather than tens or hundreds of nanosecond timescales. However, this can be a disadvantage if the RFI transmitter location is changing, since the cross-correlated power measurements which link the interference power in the astronomy and reference signal paths can decorrelate. If the decorrelation is not too severe, it can be allowed for, at the expense of a noise increase. The time domain adaptive cancelers are allowed to slightly vary their internal coefficients and adapt to changing phases during the integrations, which means that they avoid the decorrelation problem. However, the freedom to adapt also results in a noise increase. In this paper the ability of both types of cancelers to excise interference originating from a moving source is compared. The cancelers perform well on both observed and simulated data, giving complete cancellation.
△ Less
Submitted 31 March, 2010;
originally announced March 2010.
-
Interferometric Studies of Hot Stars at Sydney University
Authors:
J. G. Robertson,
J. Davis,
M. J. Ireland,
P. G. Tuthill,
W. J. Tango,
A. P. Jacob,
J. R. North,
T. A. ten Brummelaar
Abstract:
The University of Sydney has a long history in optical stellar interferometry. The first project, in the 1960s, was the Narrabri Stellar Intensity Interferometer, which measured the angular diameters of 32 hot stars and established the temperature scale for spectral classes O - F. That instrument was followed by the Sydney University Stellar Interferometer (SUSI), which is now undergoing a third…
▽ More
The University of Sydney has a long history in optical stellar interferometry. The first project, in the 1960s, was the Narrabri Stellar Intensity Interferometer, which measured the angular diameters of 32 hot stars and established the temperature scale for spectral classes O - F. That instrument was followed by the Sydney University Stellar Interferometer (SUSI), which is now undergoing a third-generation upgrade, to use the multi-wavelength PAVO beam combiner. SUSI operates at visible rather than IR wavelengths and has baselines up to 160 m, so it is well suited to the study of hot stars. A number of studies have been carried out, and more are planned when commissioning of the PAVO system is complete. Conversion of the system to allow remote operation will allow larger scientific projects to be undertaken.
△ Less
Submitted 11 May, 2009;
originally announced May 2009.
-
Observations of the pulsation of the Cepheid l Car with the Sydney University Stellar Interferometer
Authors:
J. Davis,
A. P. Jacob,
J. G. Robertson,
M. J. Ireland,
J. R. North,
W. J. Tango,
P. G. Tuthill
Abstract:
Observations of the southern Cepheid l Car to yield the mean angular diameter and angular pulsation amplitude have been made with the Sydney University Stellar Interferometer (SUSI) at a wavelength of 696 nm. The resulting mean limb-darkened angular diameter is 2.990+-0.017 mas (i.e. +-0.6 per cent) with a maximum-to-minimum amplitude of 0.560+-0.018 mas corresponding to 18.7+-0.6 per cent in th…
▽ More
Observations of the southern Cepheid l Car to yield the mean angular diameter and angular pulsation amplitude have been made with the Sydney University Stellar Interferometer (SUSI) at a wavelength of 696 nm. The resulting mean limb-darkened angular diameter is 2.990+-0.017 mas (i.e. +-0.6 per cent) with a maximum-to-minimum amplitude of 0.560+-0.018 mas corresponding to 18.7+-0.6 per cent in the mean stellar diameter. Careful attention has been paid to uncertainties, including those in measurements, in the adopted calibrator angular diameters, in the projected values of visibility squared at zero baseline, and to systematic effects. No evidence was found for a circumstellar envelope at 696 nm. The interferometric results have been combined with radial displacements of the stellar atmosphere derived from selected radial velocity data taken from the literature to determine the distance and mean diameter of l Car. The distance is determined to be 525+-26 pc and the mean radius 169+-8R{solar). Comparison with published values for the distance and mean radius show excellent agreement, particularly when a common scaling factor from observed radial velocity to pulsation velocity of the stellar atmosphere (the p-factor) is used.
△ Less
Submitted 27 December, 2008;
originally announced December 2008.
-
The radius and other fundamental parameters of the F9 V star beta Virginis
Authors:
J. R. North,
J. Davis,
J. G. Robertson,
T. R. Bedding,
H. Bruntt,
M. J. Ireland,
A. P. Jacob,
S. Lacour,
J. W. O'Byrne,
S. M. Owens,
D. Stello,
W. J. Tango,
P. G. Tuthill
Abstract:
We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of the F9 V star beta Virginis. After correcting for limb darkening and combining with the revised Hipparcos parallax, we derive a radius of 1.703 +/- 0.022 R_sun (1.3%). We have also calculated the bolometric flux from published measurements which, combined with the angular diameter, implies an effe…
▽ More
We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of the F9 V star beta Virginis. After correcting for limb darkening and combining with the revised Hipparcos parallax, we derive a radius of 1.703 +/- 0.022 R_sun (1.3%). We have also calculated the bolometric flux from published measurements which, combined with the angular diameter, implies an effective temperature of 6059 +/- 49 K (0.8%). We also derived the luminosity of beta Vir to be L = 3.51 +/- 0.08 L_sun (2.1%). Solar-like oscillations were measured in this star by Carrier et al. (2005) and using their value for the large frequency separation yields the mean stellar density with an uncertainty of about 2%. Our constraints on the fundamental parameters of beta Vir will be important to test theoretical models of this star and its oscillations.
△ Less
Submitted 15 December, 2008; v1 submitted 11 November, 2008;
originally announced November 2008.
-
Getting Lucky with Adaptive Optics: Fast AO Image Selection in the Visible with a Large Telescope
Authors:
N. M. Law,
C. D. Mackay,
R. G. Dekany,
M. Ireland,
J. P. Lloyd,
A. M. Moore,
J. G. Robertson,
P. Tuthill,
H. Woodruff
Abstract:
We describe the results from a new instrument which combines Lucky Imaging and Adaptive Optics to give the first routine direct diffraction-limited imaging in the visible on a 5m telescope. With fast image selection behind the Palomar AO system we obtained Strehl ratios of 5-20% at 700 nm in a typical range of seeing conditions, with a median Strehl of approximately 12% when 10% of the input fra…
▽ More
We describe the results from a new instrument which combines Lucky Imaging and Adaptive Optics to give the first routine direct diffraction-limited imaging in the visible on a 5m telescope. With fast image selection behind the Palomar AO system we obtained Strehl ratios of 5-20% at 700 nm in a typical range of seeing conditions, with a median Strehl of approximately 12% when 10% of the input frames are selected. At wavelengths around 700 nm the system gave diffraction-limited 35 milliarcsecond FWHMs. At 950 nm the output Strehl ratio was as high as 36% and at 500 nm the FWHM resolution was as small as 42 milliarcseconds, with a low Strehl ratio but resolution improved by factor of ~20 compared to the prevailing seeing. To obtain wider fields we also used multiple Lucky-Imaging guide stars in a configuration similar to a ground layer adaptive optics system. With eight guide stars but very undersampled data we obtained 300 milliarcsecond resolution across a 30X30 arcsec field of view in i' band.
△ Less
Submitted 13 May, 2008;
originally announced May 2008.
-
The fundamental parameters of the roAp star alpha Circini
Authors:
H. Bruntt,
J. R. North,
M. Cunha,
I. M. Brandao,
V. G. Elkin,
D. W. Kurtz,
J. Davis,
T. R. Bedding,
A. P. Jacob,
S. M. Owens,
J. G. Robertson,
W. J. Tango,
J. F. Gameiro,
M. J. Ireland,
P. G. Tuthill
Abstract:
We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of alpha Cir. This is the first detailed interferometric study of a rapidly oscillating A (roAp) star, alpha Cir being the brightest member of its class. We used the new and more accurate Hipparcos parallax to determine the radius to be 1.967+-0.066 Rs. We have constrained the bolometric flux from ca…
▽ More
We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of alpha Cir. This is the first detailed interferometric study of a rapidly oscillating A (roAp) star, alpha Cir being the brightest member of its class. We used the new and more accurate Hipparcos parallax to determine the radius to be 1.967+-0.066 Rs. We have constrained the bolometric flux from calibrated spectra to determine an effective temperature of 7420+-170 K. This is the first direct determination of the temperature of an roAp star. Our temperature is at the low end of previous estimates, which span over 1000 K and were based on either photometric indices or spectroscopic methods. In addition, we have analysed two high-quality spectra of alpha Cir, obtained at different rotational phases and we find evidence for the presence of spots. In both spectra we find nearly solar abundances of C, O, Si, Ca and Fe, high abundance of Cr and Mn, while Co, Y, Nd and Eu are overabundant by about 1 dex. The results reported here provide important observational constraints for future studies of the atmospheric structure and pulsation of alpha Cir.
△ Less
Submitted 10 March, 2008;
originally announced March 2008.
-
The Emergent Flux and Effective Temperature of Delta Canis Majoris
Authors:
J. Davis,
A. J. Booth,
M. J. Ireland,
A. P. Jacob,
J. R. North,
S. M. Owens,
J. G. Robertson,
W. J. Tango,
P. G. Tuthill
Abstract:
New angular diameter determinations for the bright southern F8 supergiant Delta CMa enable the bolometric emergent flux and effective temperature of the star to be determined with improved accuracy. The spectral flux distribution and bolometric flux have been determined from published photometry and spectrophotometry and combined with the angular diameter to derive the bolometric emergent flux F…
▽ More
New angular diameter determinations for the bright southern F8 supergiant Delta CMa enable the bolometric emergent flux and effective temperature of the star to be determined with improved accuracy. The spectral flux distribution and bolometric flux have been determined from published photometry and spectrophotometry and combined with the angular diameter to derive the bolometric emergent flux F = (6.50 plus/minus 0.24) x 10^7 W/m^2 and the effective temperature Teff = 5818 plus/minus 53 K. The new value for the effective temperature is compared with previous interferometric and infrared flux method determinations. The accuracy of the effective temperature is now limited by the uncertainty in the bolometric flux rather than by the uncertainty in the angular diameter.
△ Less
Submitted 25 September, 2007;
originally announced September 2007.
-
The Sydney University Stellar Interferometer: A Major Upgrade to Spectral Coverage and Performance
Authors:
J. Davis,
M. J. Ireland,
J. Chow,
A. P. Jacob,
R. E. Lucas,
J. R. North,
J. W. O'Byrne,
S. M. Owens,
J. G. Robertson,
E. Seneta,
W. J. Tango,
P. G. Tuthill
Abstract:
A new beam-combination and detection system has been installed in the Sydney University Stellar Interferometer working at the red end of the visual spectrum (wavelength range 500-950 nm) to complement the existing blue-sensitive system (wavelength range 430-520 nm) and to provide an increase in sensitivity. Dichroic beam-splitters have been introduced to allow simultaneous observations with both…
▽ More
A new beam-combination and detection system has been installed in the Sydney University Stellar Interferometer working at the red end of the visual spectrum (wavelength range 500-950 nm) to complement the existing blue-sensitive system (wavelength range 430-520 nm) and to provide an increase in sensitivity. Dichroic beam-splitters have been introduced to allow simultaneous observations with both spectral system, albeit with some restriction on the spectral range of the longer wavelength system (wavelength range 550-760 nm). The blue system has been upgraded to allow remote selection of wavelength and spectral bandpass, and to enable simultaneous operation with the red system with the latter providing fringe-envelope tracking. The new system and upgrades are described and examples of commissioning tests presented. As an illustration of the improvement in performance the measurement of the angular diameter of the southern F supergiant delta CMa is described and compared with previous determinations.
△ Less
Submitted 25 September, 2007;
originally announced September 2007.
-
Orbital Solution & Fundamental Parameters of sigma Scorpii
Authors:
J. R. North,
J. Davis,
P. G. Tuthill,
W. J. Tango,
J. G. Robertson
Abstract:
The first orbital solution for the spectroscopic pair in the multiple star system sigma Scorpii, determined from measurements with the Sydney University Stellar Interferometer (SUSI), is presented. The primary component is of beta Cephei variable type and has been one of the most intensively studied examples of its class. The orbital solution, when combined with radial velocity results found in…
▽ More
The first orbital solution for the spectroscopic pair in the multiple star system sigma Scorpii, determined from measurements with the Sydney University Stellar Interferometer (SUSI), is presented. The primary component is of beta Cephei variable type and has been one of the most intensively studied examples of its class. The orbital solution, when combined with radial velocity results found in the literature, yields a distance of 174(+23,-18) pc, which is consistent with, but more accurate than the Hipparcos value. For the primary component we determine 18.4+/-5.4 M_sun, -4.12+/-0.34 mag and 12.7+/-1.8 R_sun for the mass, absolute visual magnitude and radius respectively. A B1 dwarf spectral type and luminosity class for the secondary is proposed from the mass determination of 11.9+/-3.1 M_sun and the estimated system age of 10 Myr.
△ Less
Submitted 5 July, 2007;
originally announced July 2007.
-
The radius and mass of the subgiant star bet Hyi from interferometry and asteroseismology
Authors:
J. R. North,
J. Davis,
T. R. Bedding,
M. J. Ireland,
A. P. Jacob,
J. O'Byrne,
S. M. Owens,
J. G. Robertson,
W. J. Tango,
P. G. Tuthill
Abstract:
We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of beta Hydri. This star is a nearby G2 subgiant whose mean density was recently measured with high precision using asteroseismology. We determine the radius and effective temperature of the star to be 1.814+/-0.017 R_sun (0.9%) and 5872+/-44 K (0.7%) respectively. By combining this value with the me…
▽ More
We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of beta Hydri. This star is a nearby G2 subgiant whose mean density was recently measured with high precision using asteroseismology. We determine the radius and effective temperature of the star to be 1.814+/-0.017 R_sun (0.9%) and 5872+/-44 K (0.7%) respectively. By combining this value with the mean density, as estimated from asteroseismology, we make a direct estimate of the stellar mass. We find a value of 1.07+/-0.03 M_sun (2.8%), which agrees with published estimates based on fitting in the H-R diagram, but has much higher precision. These results place valuable constraints on theoretical models of beta Hyi and its oscillation frequencies.
△ Less
Submitted 2 July, 2007;
originally announced July 2007.
-
Volume Phase Holographic Gratings: Polarization Properties and Diffraction Efficiency
Authors:
I. K. Baldry,
J. Bland-Hawthorn,
J. G. Robertson
Abstract:
We discuss the polarization properties and first-order diffraction efficiencies of volume phase holographic (VPH) transmission gratings, which can be exploited to improve the throughput of modern spectrographs. The wavelength of peak efficiency can be tuned by adjustment of the incidence angle. We show that the variation of the Kogelnik efficiency versus Bragg angle depends only on one parameter…
▽ More
We discuss the polarization properties and first-order diffraction efficiencies of volume phase holographic (VPH) transmission gratings, which can be exploited to improve the throughput of modern spectrographs. The wavelength of peak efficiency can be tuned by adjustment of the incidence angle. We show that the variation of the Kogelnik efficiency versus Bragg angle depends only on one parameter, given by $P_{tune} = (Δn d)/(n Λ)$, where: $Δn$ is semi-amplitude of the refractive index modulation; $n$ is the average index; $d$ is the thickness of the active layer; and $Λ$ is the grating period. The efficiency has a well defined dependence on polarization. In particular, it is possible to obtain theoretical 100% diffraction efficiency with one linear polarization at any angle or to obtain 100% efficiency with unpolarized light at specific angles. In the latter case, high efficiency is the result of aligning the peaks of the s- and p-polarization efficiency-versus-thickness curves. The first of these `s-p-phased gratings' for astronomy is in use with the 6dF spectrograph. Consideration of polarization is particularly important for high spectral resolution, which requires large incidence angles. We also discuss the possibility of separating polarization states for improved throughput along the entire optical train of a spectrograph.
△ Less
Submitted 17 February, 2004;
originally announced February 2004.
-
Multi-wavelength Diameters of Nearby Miras and Semiregulars
Authors:
M. J. Ireland,
P. G. Tuthill,
T. R. Bedding,
J. G. Robertson,
A. P. Jacob
Abstract:
We have used optical interferometry to obtain multi-wavelength visibility curves for eight red giants over the wavelength range 650--1000 nm. The observations consist of wavelength-dispersed fringes recorded with MAPPIT (Masked APerture-Plane Interference Telescope) at the 3.9-m Anglo-Australian Telescope. We present results for four Miras (R Car, $o$ Cet, R Hya, R Leo) and four semi-regular var…
▽ More
We have used optical interferometry to obtain multi-wavelength visibility curves for eight red giants over the wavelength range 650--1000 nm. The observations consist of wavelength-dispersed fringes recorded with MAPPIT (Masked APerture-Plane Interference Telescope) at the 3.9-m Anglo-Australian Telescope. We present results for four Miras (R Car, $o$ Cet, R Hya, R Leo) and four semi-regular variables (R Dor, W Hya, L$_2$ Pup, $γ$ Cru). All stars except $γ$ Cru show strong variations of angular size with wavelength. A uniform-disk model was found to be a poor fit in most cases, with Gaussian (or other more tapered profiles) preferred. This, together with the fact that most stars showed a systematic increase in apparent size toward the blue and a larger-than-expected linear size, even in the red, all point toward significant scattering by dust in the inner circumstellar environment. Some stars showed evidence for asymmetric brightness profiles, while L$_2$ Pup required a two-component model, indicating an asymmetrical circumstellar dust shell.
△ Less
Submitted 13 February, 2004;
originally announced February 2004.
-
SUMSS: A Wide-Field Radio Imaging Survey of the Southern Sky. II. The Source Catalogue
Authors:
T. Mauch,
T. Murphy,
H. J. Buttery,
J. Curran,
R. W. Hunstead,
B. Piestrzynski,
J. G. Robertson,
E. M. Sadler
Abstract:
This paper is the second in a series describing the Sydney University Molonglo Sky Survey (SUMSS) being carried out at 843MHz with the Molonglo Observatory Synthesis Telescope (MOST). The survey will consist of ~590 4.3deg. x 4.3deg. mosaic images with 45"x45"cosec|dec.| resolution, and a source catalogue. In this paper we describe the initial release (version 1.0) of the source catalogue consis…
▽ More
This paper is the second in a series describing the Sydney University Molonglo Sky Survey (SUMSS) being carried out at 843MHz with the Molonglo Observatory Synthesis Telescope (MOST). The survey will consist of ~590 4.3deg. x 4.3deg. mosaic images with 45"x45"cosec|dec.| resolution, and a source catalogue. In this paper we describe the initial release (version 1.0) of the source catalogue consisting of 107,765 radio sources made by fitting elliptical gaussians in 271 SUMSS mosaics to a limiting peak brightness of 6mJy/beam at dec.<=-50deg. and 10mJy/beam at dec.>-50deg.. The catalogue covers approximately 3500deg^2 of the southern sky with dec.<=-30deg., about 43 per cent of the total survey area. Positions in the catalogue are accurate to within 1"-2" for sources with peak brightness A>=20mJy/beam and are always better than 10". The internal flux density scale is accurate to within 3 per cent. Image artefacts have been classified using a decision tree, which correctly identifies and rejects spurious sources in over 96 per cent of cases. Analysis of the catalogue shows that it is highly uniform and is complete to 8mJy at dec.<=-50^deg. and 18mJy at dec.>-50deg.. In this release of the catalogue about 7000 sources are found in the overlap region with the NRAO VLA Sky Survey (NVSS) at 1.4GHz. We calculate a median spectral index of alpha=-0.83 between 1.4GHz and 843MHz. This version of the catalogue will be released via the World Wide Web with future updates as new mosaics are released.
△ Less
Submitted 10 March, 2003;
originally announced March 2003.
-
Multi-wavelength observations of the red giant R Doradus with the MAPPIT interferometer
Authors:
A. P. Jacob,
T. R. Bedding,
J. G. Robertson,
J. R. Barton,
C. A. Haniff,
R. G. Marson,
M. Scholz
Abstract:
We present visibility measurements of the nearby Mira-like star R Doradus taken over a wide range of wavelengths (650-990 nm). The observations were made using MAPPIT (Masked APerture-Plane Interference Telescope), an interferometer operating at the 3.9-m Anglo-Australian Telescope. We used a slit to mask the telescope aperture and prism to disperse the interference pattern in wavelength. We obs…
▽ More
We present visibility measurements of the nearby Mira-like star R Doradus taken over a wide range of wavelengths (650-990 nm). The observations were made using MAPPIT (Masked APerture-Plane Interference Telescope), an interferometer operating at the 3.9-m Anglo-Australian Telescope. We used a slit to mask the telescope aperture and prism to disperse the interference pattern in wavelength. We observed in R Dor strong decreases in visibility within the TiO absorption bands. The results are in general agreement with theory but differ in detail, suggesting that further work is needed to refine the theoretical models.
△ Less
Submitted 29 November, 2000;
originally announced November 2000.
-
ATLAS: a Cassegrain spectrograph based on volume phase holographic gratings
Authors:
J. G. Robertson,
K. Taylor,
I. K. Baldry,
P. R. Gillingham,
S. C. Barden
Abstract:
We are proposing a new spectrograph (ATLAS) which would revolutionise intermediate-dispersion observations at the AAT. Based on the new technology of Volume Phase Holographic gratings, and using transmission optics, ATLAS offers high throughput and a wide field (24'). It will be ideally suited to extensive surveys of faint objects. It has been designed with a collimated beam diameter of 150 mm,…
▽ More
We are proposing a new spectrograph (ATLAS) which would revolutionise intermediate-dispersion observations at the AAT. Based on the new technology of Volume Phase Holographic gratings, and using transmission optics, ATLAS offers high throughput and a wide field (24'). It will be ideally suited to extensive surveys of faint objects. It has been designed with a collimated beam diameter of 150 mm, giving resolution lambda/delta lambda up to nearly 10,000 with a 1.5 arcsecond slit and good efficiency. It will be a dual-beam instrument, to maximise observing speed and allow optimised optical coatings to be used. The project is working towards its Concept Design Review which will occur during 2000.
△ Less
Submitted 27 June, 2000;
originally announced June 2000.
-
Multi-wavelength visibility measurements of the red giant R Doradus
Authors:
A. P. Jacob,
T. R. Bedding,
J. G. Robertson,
J. R. Barton,
C. A. Haniff,
R. G. Marson,
M. Scholz
Abstract:
We present visibility measurements of the nearby Mira-like star R Doradus taken over a wide range of wavelengths (650--990 nm). The observations were made using MAPPIT (Masked APerture-Plane Interference Telescope), an interferometer operating at the 3.9-m Anglo-Australian Telescope. We used a slit to mask the telescope aperture and prism to disperse the interference pattern in wavelength. We ob…
▽ More
We present visibility measurements of the nearby Mira-like star R Doradus taken over a wide range of wavelengths (650--990 nm). The observations were made using MAPPIT (Masked APerture-Plane Interference Telescope), an interferometer operating at the 3.9-m Anglo-Australian Telescope. We used a slit to mask the telescope aperture and prism to disperse the interference pattern in wavelength. We observed in R Dor strong decreases in visibility within the TiO absorption bands. The results are in general agreement with theory but differ in detail, suggesting that further work is needed to refine the theoretical models.
△ Less
Submitted 9 May, 2000;
originally announced May 2000.
-
Wavelength dependence of angular diameters of M giants: an observational perspective
Authors:
A. P. Jacob,
T. R. Bedding,
J. G. Robertson,
M. Scholz
Abstract:
We discuss the wavelength dependence of angular diameters of M giants from an observational perspective. Observers cannot directly measure an optical-depth radius for a star, despite this being a common theoretical definition. Instead, they can use an interferometer to measure the square of the fringe visibility. We present new plots of the wavelength-dependent centre-to-limb variation (CLV) of…
▽ More
We discuss the wavelength dependence of angular diameters of M giants from an observational perspective. Observers cannot directly measure an optical-depth radius for a star, despite this being a common theoretical definition. Instead, they can use an interferometer to measure the square of the fringe visibility. We present new plots of the wavelength-dependent centre-to-limb variation (CLV) of intensity of the stellar disk as well as visibility for Mira and non-Mira M giant models. We use the terms ``CLV spectra'' and ``visibility spectra'' for these plots. We discuss a model-predicted extreme limb-darkening effect (also called the narrow-bright-core effect) in very strong TiO bands which can lead to a misinterpretation of the size of a star in these bands. We find no evidence as yet that this effect occurs in real stars. Our CLV spectra can explain the similarity in visibilities of R Dor (M8IIIe) that have been observed recently despite the use of two different passbands. We compare several observations with models and find the models generally under-estimate the observed variation in visibility with wavelength. We present CLV and visibility spectra for a model that is applicable to the M supergiant alpha Ori.
△ Less
Submitted 5 November, 1999;
originally announced November 1999.
-
Emission within a Damped Lyman Alpha Absorption Trough: the Complex Sight Line Towards Q2059-360
Authors:
Bruno Leibundgut,
J. Gordon Robertson
Abstract:
We present new spectroscopic observations of the quasar Q2059-360, confirming the existence of an emission feature within the Damped Lyman Alpha (DLA) absorption trough. By observing also at slit positions offset from the quasar, we show that the emission is spatially extended by at least a few arcseconds, and hence confirm that the feature seen must be due to emission rather than unusual absorp…
▽ More
We present new spectroscopic observations of the quasar Q2059-360, confirming the existence of an emission feature within the Damped Lyman Alpha (DLA) absorption trough. By observing also at slit positions offset from the quasar, we show that the emission is spatially extended by at least a few arcseconds, and hence confirm that the feature seen must be due to emission rather than unusual absorption characteristics. We find that the DLA trough is very close in redshift to the broad Lyman~$α$ emission line of the QSO, with the result that the DLA absorption removes much of the peak region of that line. Despite the similarity of the redshifts of the DLA and the QSO, the lack of high-ionization lines of the DLA system and the unresolved widths of the corresponding metal lines indicate that the DLA cloud is not an associated system. The emission feature has a large velocity offset of +490 km/s with respect to the DLA system, and is resolved in velocity, comprising two components with a separation of ~ 300 km/s. We consider three possibilities: (1) Both emission and absorption occur within an object similar to the high redshift Lyman-break galaxies; (2) The emission feature arises from an object distinct from both the DLA absorber and the QSO, perhaps a young star-forming galaxy or a proto-galactic clump. It could be associated with the DLA absorber and perhaps the QSO in a compact group or cluster; (3) The redshifts are such that the emission feature could be due to Narrow Line Region filaments of the QSO, if the DLA absorption covers a sufficiently small angular size to allow the filaments to be seen beyond the edge of the DLA cloud.
△ Less
Submitted 20 October, 1998;
originally announced October 1998.
-
Interferometry and spectroscopy of Beta Cen: a Beta Cephei star in a binary system
Authors:
J. G. Robertson,
T. R. Bedding,
C. Aerts,
C. Waelkens,
R. G. Marson,
J. R. Barton
Abstract:
Beta Cen is a bright Beta Cephei variable and has long been suspected to be a binary. Here we report interferometric observations with the 3.9-m Anglo-Australian Telescope at a single epoch which show the star to be a binary with components separated by 15 milliarcsec and having approximately equal luminosities at 486 nm. We also present high-resolution spectra taken over five nights with the ES…
▽ More
Beta Cen is a bright Beta Cephei variable and has long been suspected to be a binary. Here we report interferometric observations with the 3.9-m Anglo-Australian Telescope at a single epoch which show the star to be a binary with components separated by 15 milliarcsec and having approximately equal luminosities at 486 nm. We also present high-resolution spectra taken over five nights with the ESO CAT which show Beta Cen to be a double-lined spectroscopic binary. We identify two pulsation frequencies in the primary. Further spectroscopic and interferometric studies of this double star should allow determination of its orbital parameters and component masses.
△ Less
Submitted 15 September, 1998; v1 submitted 12 September, 1998;
originally announced September 1998.
-
The angular diameter of R Doradus: a nearby Mira-like star
Authors:
T. R. Bedding,
A. A. Zijlstra,
O. von der Luhe,
J. G. Robertson,
R. G. Marson,
J. R. Barton,
B. S. Carter
Abstract:
We find the angular diameter of R Doradus to be 57 +/- 5 mas, exceeding that of Betelgeuse and implying that R Dor is larger in apparent size than every star except the Sun. R Dor is shown to be closely related to the Mira variables. We estimate an effective temperature of 2740 +/- 190 K, a distance of 61 +/- 7 pc, a luminosity of 6500 +/- 1400 Lsol and a radius of 370 +/- 50 Rsol. The character…
▽ More
We find the angular diameter of R Doradus to be 57 +/- 5 mas, exceeding that of Betelgeuse and implying that R Dor is larger in apparent size than every star except the Sun. R Dor is shown to be closely related to the Mira variables. We estimate an effective temperature of 2740 +/- 190 K, a distance of 61 +/- 7 pc, a luminosity of 6500 +/- 1400 Lsol and a radius of 370 +/- 50 Rsol. The characteristics of R Dor are consistent with it being near the edge of a Mira instability strip. We detect non-zero closure phases from R Dor, indicating an asymmetric brightness distribution. We also observed W Hya, a small-amplitude Mira, for which we find an angular diameter of 44 +/- 4 mas.
△ Less
Submitted 6 January, 1997;
originally announced January 1997.
-
An Optical Interferometer with Wavelength Dispersion
Authors:
T. R. Bedding,
J. G. Robertson,
R. G. Marson
Abstract:
MAPPIT is an optical interferometer installed at the coude focus of the 3.9-m Anglo-Australian Telescope. The instrument combines non-redundant masking with wavelength dispersion and is able to record fringes simultaneously over a wide bandwidth. For typical observations centred near 600 nm, the bandwidth is 55 nm and the spectral resolution is 3 nm. This paper describes the instrument and the d…
▽ More
MAPPIT is an optical interferometer installed at the coude focus of the 3.9-m Anglo-Australian Telescope. The instrument combines non-redundant masking with wavelength dispersion and is able to record fringes simultaneously over a wide bandwidth. For typical observations centred near 600 nm, the bandwidth is 55 nm and the spectral resolution is 3 nm. This paper describes the instrument and the data processing methods and presents some results. We find the star sigma Sgr to be a close binary; the system is only partially resolved, with a separation of (11.5 +/- 2) milliarcsec (assuming the components to have equal magnitudes). We also give angular diameter measurements of two red giant stars, alpha Sco and beta Gru. The observations of beta Gru (spectral type M5 III) resolve the star for the first time and give an equivalent uniform-disk diameter of (27 +/- 3) milliarcsec.
△ Less
Submitted 4 April, 1994;
originally announced April 1994.