-
WST -- Widefield Spectroscopic Telescope: design of a new 12m class telescope dedicated to widefield Multi-object and Integral Field Spectroscopy
Authors:
P. Dierickx,
T. Travouillon,
G. Gausachs,
R. Bacon,
C. Cudennec,
I. Bryson,
D. Lee,
J. Kragt,
E. Muslimov,
K. Dohlen,
J. Kosmalski,
J. Vernet,
T. Lépine,
P. Doel,
D. Brooks
Abstract:
The Wide-Field Spectroscopic Telescope (WST) is a concept for a 12-m class seeing-limited telescope providing two concentric fields of view for simultaneous Multi-Object Spectroscopy and Integral Field Spectroscopy. The specified wavelength range is 0.35-1.6 microns. The baseline optical design relies on a corrected Cassegrain solution feeding Multi-Object spectrographs through fibres, while the c…
▽ More
The Wide-Field Spectroscopic Telescope (WST) is a concept for a 12-m class seeing-limited telescope providing two concentric fields of view for simultaneous Multi-Object Spectroscopy and Integral Field Spectroscopy. The specified wavelength range is 0.35-1.6 microns. The baseline optical design relies on a corrected Cassegrain solution feeding Multi-Object spectrographs through fibres, while the central area of the field is propagated down to a gravity-stable Integral Field Station housing 144 spectrographs. The Cassegrain corrector also provides for atmospheric dispersion compensation. All optical components are within commercially available dimensions. With a view to minimizing risks and costs, to the maximum possible extent the telescope relies on proven subsystem solutions. An exception is the tip-tilt secondary mirror, which would likely have to provide some rejection of wind shake. An iteration of the optical design is ongoing, with a view to mitigating the weaknesses of the first baseline design. The telescope would be wavefront-controlled on-sky at the common-path MOS focus. Controls in the IFS path will need to compensate for the effect of subsequent differentials - wavefront and line of sight. There is no shortage of degrees of freedom and metrology solution to do so. The size of the dome is driven by the Nasmyth footprint and the height of the pier, which houses the IFS station. The baseline assumption is that a VLT-like enclosure would provide suitable shielding and ventilation.
△ Less
Submitted 4 June, 2024;
originally announced June 2024.
-
Multi-purpose InSTRument for Astronomy at Low-resolution: MISTRAL@OHP
Authors:
J. Schmitt,
C. Adami,
M. Dennefeld,
F. Agneray,
S. Basa,
J. C. Brunel,
V. Buat,
D. Burgarella,
C. Carvalho,
G. Castagnoli,
N. Grosso,
F. Huppert,
C. Moreau,
F. Moreau,
L. Moreau,
E. Muslimov,
S. Pascal,
S. Perruchot,
D. Russeil,
J. L. Beuzit,
F. Dolon,
M. Ferrari,
B. Hamelin,
A. LevanSuu,
K. Aravind
, et al. (9 additional authors not shown)
Abstract:
MISTRAL is the new Faint Object Spectroscopic Camera mounted at the folded Cassegrain focus of the 1.93m telescope of Haute-Provence Observatory. We describe the design and components of the instrument and give some details about its operation. We emphasise in particular the various observing modes and the performances of the detector. A short description is also given about the working environmen…
▽ More
MISTRAL is the new Faint Object Spectroscopic Camera mounted at the folded Cassegrain focus of the 1.93m telescope of Haute-Provence Observatory. We describe the design and components of the instrument and give some details about its operation. We emphasise in particular the various observing modes and the performances of the detector. A short description is also given about the working environment. Various types of objects, including stars, nebulae, comets, novae, galaxies have been observed during various test phases to evaluate the performances of the instrument. The instrument covers the range of 4000 to 8000A with the blue setting, or from 6000 to 10000A with the red setting, at an average spectral resolution of 700. Its peak efficiency is about 22% at 6000A. In spectroscopy, a limiting magnitude of 19.5 can be achieved for a point source in one hour with a signal to noise of 3 in the continuum (and better if emission lines are present). In imaging mode, limiting magnitudes of 20-21 can be obtained in 10-20mn (with average seing conditions of 2.5 arcsec at OHP). The instrument is very users-friendly and can be put into operations in less than 15mn (rapid change-over from the other instrument in use) if required by the science (like for Gamma-Rays Bursts). Some first scientific results are described for various types of objects, and in particular for the follow-up of GRBs. While some further improvements are still under way, in particular to ease the switch from blue to red setting and add more grisms or filters, MISTRAL is ready for the follow-up of transients and other variable objects, in the soon-to-come era of e.g. the SVOM satellite and of the Rubin telescope.
△ Less
Submitted 4 April, 2024;
originally announced April 2024.
-
First light of VLT/HiRISE: High-resolution spectroscopy of young giant exoplanets
Authors:
A. Vigan,
M. El Morsy,
M. Lopez,
G. P. P. L. Otten,
J. Garcia,
J. Costes,
E. Muslimov,
A. Viret,
Y. Charles,
G. Zins,
G. Murray,
A. Costille,
J. Paufique,
U. Seemann,
M. Houllé,
H. Anwand-Heerwart,
M. Phillips,
A. Abinanti,
P. Balard,
I. Baraffe,
J. -A. Benedetti,
P. Blanchard,
L. Blanco,
J. -L. Beuzit,
E. Choquet
, et al. (24 additional authors not shown)
Abstract:
A major endeavor of this decade is the direct characterization of young giant exoplanets at high spectral resolution to determine the composition of their atmosphere and infer their formation processes and evolution. Such a goal represents a major challenge owing to their small angular separation and luminosity contrast with respect to their parent stars. Instead of designing and implementing comp…
▽ More
A major endeavor of this decade is the direct characterization of young giant exoplanets at high spectral resolution to determine the composition of their atmosphere and infer their formation processes and evolution. Such a goal represents a major challenge owing to their small angular separation and luminosity contrast with respect to their parent stars. Instead of designing and implementing completely new facilities, it has been proposed to leverage the capabilities of existing instruments that offer either high contrast imaging or high dispersion spectroscopy, by coupling them using optical fibers. In this work we present the implementation and first on-sky results of the HiRISE instrument at the very large telescope (VLT), which combines the exoplanet imager SPHERE with the recently upgraded high resolution spectrograph CRIRES using single-mode fibers. The goal of HiRISE is to enable the characterization of known companions in the $H$ band, at a spectral resolution of the order of $R = λ/Δλ= 100\,000$, in a few hours of observing time. We present the main design choices and the technical implementation of the system, which is constituted of three major parts: the fiber injection module inside of SPHERE, the fiber bundle around the telescope, and the fiber extraction module at the entrance of CRIRES. We also detail the specific calibrations required for HiRISE and the operations of the instrument for science observations. Finally, we detail the performance of the system in terms of astrometry, temporal stability, optical aberrations, and transmission, for which we report a peak value of $\sim$3.9% based on sky measurements in median observing conditions. Finally, we report on the first astrophysical detection of HiRISE to illustrate its potential.
△ Less
Submitted 22 November, 2023; v1 submitted 21 September, 2023;
originally announced September 2023.
-
Spectropolarimeter's optical design for the Arago space mission project
Authors:
Eduard Muslimov,
Coralie Neiner
Abstract:
Arago is a concept of space mission submitted to the European Space Agency's M7 science program. It will target a number of science cases in stellar physics including the characterisation of star-planet interactions. The concept is based on a 1-m class Ritchey-Chretien F/13 telescope mounted on an Ariel-type platform. The scientific payload includes a common polarimetric unit and 2 spectrographs c…
▽ More
Arago is a concept of space mission submitted to the European Space Agency's M7 science program. It will target a number of science cases in stellar physics including the characterisation of star-planet interactions. The concept is based on a 1-m class Ritchey-Chretien F/13 telescope mounted on an Ariel-type platform. The scientific payload includes a common polarimetric unit and 2 spectrographs connected via a dichroic splitter. The polarimetric unit consists of 6 MgF2 plates in pairs connected by optical contact and a Wollaston analyzer. Each of the spectral channels represents an echelle spectrograph. The first one will operate in the UV range 119-320 nm with the spectral resolving power of R>25 000. It consists of an off-axis parabolic collimator, an echelle grating in a quasi-Littrow mounting, a cross-disperser concave grating, and a CMOS camera. The cross-disperser grating works also as a camera mirror and represents a holographic grating recorded with aberrated wavefronts and on a spherical substrate. The spectral image is projected onto a d-doped CMOS detector. The second spectral channel operates in the visible range 350-888 nm with R>35 000 and uses an immersed grating. The image is focused with a 4-lens objective onto a CMOS detector. In addition, the optical design includes two stages of fine-guiding system. The first stage represents a projecting system tracking the image around the entrance pinhole and communicating with the platform actuators. The second one is fed by the 0-th diffraction order of the visible channel echelle. It is communicating with a tip-tilt mirror in front of the dichroic. The first stage should improve the platform pointing accuracy from 8" to 200 mas precision to guarantee that the star images passes through the instrument's entrance pinhole. The second stage should correct the pointing accuracy further as well as some thermo-elastic deformations.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
A pyramid-based adaptive optics for the high-resolution echelle spectrograph at SAO RAS 6-m telescope
Authors:
Eduard Muslimov,
Gennadiy Valyavin,
Vincent Chambouleyron,
Felipe Pedreros Bustos,
Idir Boudjema
Abstract:
We propose a design of an adaptive optics (AO) system for the high-resolution fiber-fed echelle spectrograph installed at the Nasmyth focus of the 6-m BTA telescope at the Special Astrophysical Observatory (SAO) of the Russian Academy of Sciences (RAS). The system will be based on a pyramid wavefront sensor and benefit from the experience of the Laboratoire d'Astrophysique de Marseille team in the…
▽ More
We propose a design of an adaptive optics (AO) system for the high-resolution fiber-fed echelle spectrograph installed at the Nasmyth focus of the 6-m BTA telescope at the Special Astrophysical Observatory (SAO) of the Russian Academy of Sciences (RAS). The system will be based on a pyramid wavefront sensor and benefit from the experience of the Laboratoire d'Astrophysique de Marseille team in the field of adaptive optics. The AO will operate in the visible domain of 430-680 nm, in an f\30 input beam and provide correction for the on-axis source only. The main challenges in this particular design are insetting inserting the AO into an existing optical system and maintaining the focal and pupil planes configuration, fitting within the instrument's flux budget as well as limitations on the total cost of the AO bench. According to the current design, the AO bench will use an additional relay consisting of 2 spherical mirrors to re-collimate the beam and project the pupil onto a small deformable mirror. A dichroic splitter will be used to longwave component to the pyramid wavefront sensor branch based on refractive optics only. Using off-the-shelf components only we can reach the instrumental wavefront error of 0.016 waves PTV with a 20 nm bandpass filter at 700 nm. Using folding mirrors and refocusing of the fiber's microlens we restore the nominal geometry of the beam feeding the spectrograph. The final goal for the AO system is to increase the energy concentration in spot at the spectrograph's entrance, and our preliminary modelling shows that we can gain by factor of 69.5 with the typical atmospheric conditions at SAO RAS.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Connecting SPHERE and CRIRES+ for the characterisation of young exoplanets at high spectral resolution: status update of VLT/HiRISE
Authors:
A. Vigan,
M. Lopez,
M. El Morsy,
E. Muslimov,
A. Viret,
G. Zins,
G. Murray,
A. Costille,
G. P. P. L. Otten,
U. Seemann,
H. Anwand-Heerwart,
K. Dohlen,
P. Blanchard,
J. Garcia,
Y. Charles,
N. Tchoubaklian,
T. Ely,
M. Phillips,
J. Paufique,
J. -L. Beuzit,
M. Houllé,
J. Costes,
R. Pourcelot,
I. Baraffe,
R. Dorn
, et al. (10 additional authors not shown)
Abstract:
New generation exoplanet imagers on large ground-based telescopes are highly optimised for the detection of young giant exoplanets in the near-infrared, but they are intrinsically limited for their characterisation by the low spectral resolution of their integral field spectrographs ($R<100$). High-dispersion spectroscopy at $R \gg 10^4$ would be a powerful tool for the characterisation of these p…
▽ More
New generation exoplanet imagers on large ground-based telescopes are highly optimised for the detection of young giant exoplanets in the near-infrared, but they are intrinsically limited for their characterisation by the low spectral resolution of their integral field spectrographs ($R<100$). High-dispersion spectroscopy at $R \gg 10^4$ would be a powerful tool for the characterisation of these planets, but there is currently no high-resolution spectrograph with extreme adaptive optics and coronagraphy that would enable such characterisation. With project HiRISE we propose to use fiber coupling to combine the capabilities of two flagship instruments at the Very Large Telescope in Chile: the exoplanet imager SPHERE and the high-resolution spectrograph CRIRES+. The coupling will be implemented at the telescope in early 2023. We provide a general overview of the implementation of HiRISE, of its assembly, integration and testing (AIT) phase in Europe, and a brief assessment of its expected performance based on the final hardware.
△ Less
Submitted 13 July, 2022;
originally announced July 2022.
-
Validation of strategies for coupling exoplanet PSFs into single-mode fibres for high-dispersion coronagraphy
Authors:
M. El Morsy,
A. Vigan,
M. Lopez,
G. P. P. L. Otten,
E. Choquet,
F. Madec,
A. Costille,
J. -F. Sauvage,
K. Dohlen,
E. Muslimov,
R. Pourcelot,
J. Floriot,
J. -A. Benedetti,
P. Blanchard,
P. Balard,
G. Murray
Abstract:
On large ground-based telescopes, the combination of extreme adaptive optics (ExAO) and coronagraphy with high-dispersion spectroscopy (HDS), sometimes referred to as high-dispersion coronagraphy (HDC), is starting to emerge as a powerful technique for the direct characterisation of giant exoplanets. The high spectral resolution not only brings a major gain in terms of accessible spectral features…
▽ More
On large ground-based telescopes, the combination of extreme adaptive optics (ExAO) and coronagraphy with high-dispersion spectroscopy (HDS), sometimes referred to as high-dispersion coronagraphy (HDC), is starting to emerge as a powerful technique for the direct characterisation of giant exoplanets. The high spectral resolution not only brings a major gain in terms of accessible spectral features but also enables a better separation of the stellar and planetary signals. Ongoing projects such as Keck/KPIC, Subaru/REACH, and VLT/HiRISE base their observing strategy on the use of a few science fibres, one of which is dedicated to sampling the planet's signal, while the others sample the residual starlight in the speckle field. The main challenge in this approach is to blindly centre the planet's point spread function (PSF) accurately on the science fibre, with an accuracy of less than 0.1 $λ/D$ to maximise the coupling efficiency. In the context of the HiRISE project, three possible centring strategies are foreseen, either based on retro-injecting calibration fibres to localise the position of the science fibre or based on a dedicated centring fibre. We implemented these three approaches, and we compared their centring accuracy using an upgraded setup of the MITHiC high-contrast imaging testbed, which is similar to the setup that will be adopted in HiRISE. Our results demonstrate that reaching a specification accuracy of 0.1 $λ/D$ is extremely challenging regardless of the chosen centring strategy. It requires a high level of accuracy at every step of the centring procedure, which can be reached with very stable instruments. We studied the contributors to the centring error in the case of MITHiC and we propose a quantification for some of the most impacting terms.
△ Less
Submitted 24 May, 2022;
originally announced May 2022.
-
Curved detector-based optical design for the VLT/BlueMUSE instrument
Authors:
Alexandre Jeanneau,
Johan Kosmalski,
Eduard Muslimov,
Emmanuel Hugot,
Roland Bacon,
Johan Richard
Abstract:
BlueMUSE (Blue Multi Unit Spectroscopic Explorer) is a blue-optimised, medium spectral resolution, panoramic integral field spectrograph proposed for the Very Large Telescope (VLT) and based on the MUSE concept. BlueMUSE will open up a new range of galactic and extragalactic science cases allowed by its specific capabilities in the 350 - 580 nm range: an optimised end-to-end transmission down to 3…
▽ More
BlueMUSE (Blue Multi Unit Spectroscopic Explorer) is a blue-optimised, medium spectral resolution, panoramic integral field spectrograph proposed for the Very Large Telescope (VLT) and based on the MUSE concept. BlueMUSE will open up a new range of galactic and extragalactic science cases allowed by its specific capabilities in the 350 - 580 nm range: an optimised end-to-end transmission down to 350 nm, a larger FoV (up to $1.4 \times 1.4$ arcmin$^2$) sampled at 0.3 arcsec, and a higher spectral resolution ($λ/Δλ\sim 3500$) compared to MUSE. To our knowledge, achieving such capabilities with a comparable mechanical footprint and an identical detector format ($4\text{k} \times 4\text{k}$, 15 $\mathrm{μm}$ CCD) would not be possible with a conventional spectrograph design. In this paper, we present the optomechanical architecture and design of BlueMUSE at pre-phase A level, with a particular attention to some original aspects such as the use of curved detectors.
△ Less
Submitted 19 January, 2021;
originally announced January 2021.
-
Direct characterization of young giant exoplanets at high spectral resolution by coupling SPHERE and CRIRES+
Authors:
G. P. P. L. Otten,
A. Vigan,
E. Muslimov,
M. N'Diaye,
E. Choquet,
U. Seemann,
K. Dohlen,
M. Houllé,
P. Cristofari,
M. W. Phillips,
Y. Charles,
I. Baraffe,
J. -L. Beuzit,
A. Costille,
R. Dorn,
M. El Morsy,
M. Kasper,
M. Lopez,
C. Mordasini,
R. Pourcelot,
A. Reiners,
J. -F. Sauvage
Abstract:
Studies of atmospheres of directly imaged exoplanets with high-resolution spectrographs have shown that their characterization is predominantly limited by noise on the stellar halo at the location of the studied exoplanet. An instrumental combination of high-contrast imaging and high spectral resolution that suppresses this noise and resolves the spectral lines can therefore yield higher quality s…
▽ More
Studies of atmospheres of directly imaged exoplanets with high-resolution spectrographs have shown that their characterization is predominantly limited by noise on the stellar halo at the location of the studied exoplanet. An instrumental combination of high-contrast imaging and high spectral resolution that suppresses this noise and resolves the spectral lines can therefore yield higher quality spectra. We study the performance of the proposed HiRISE fiber coupling between the SPHERE and CRIRES+ at the VLT for spectral characterization of directly imaged planets. Using end-to-end simulations of HiRISE we determine the S/N of the detection of molecular species for known exoplanets in $H$ and $K$ bands, and compare them to CRIRES+. We investigate the ultimate detection limits of HiRISE as a function of stellar magnitude, and we quantify the impact of different coronagraphs and of the system transmission. We find that HiRISE largely outperforms CRIRES+ for companions around bright hosts like $β$ Pic or 51 Eri. For an $H=3.5$ host, we observe a gain of a factor of up to 16 in observing time with HiRISE to reach the same S/N on a companion at 200 mas. More generally, HiRISE provides better performance than CRIRES+ in two-hour integration times between 50-350 mas for hosts with $H<8.5$ and between 50-700 mas for $H<7$. For fainter hosts like PDS 70 and HIP 65426, no significant improvements are observed. We find that using no coronagraph yields the best S/N when characterizing known exoplanets due to higher transmission and fiber-based starlight suppression. We demonstrate that the overall transmission of the system is in fact the main driver of performance. Finally, we show that HiRISE outperforms the best detection limits of SPHERE for bright stars, opening major possibilities for the characterization of future planetary companions detected by other techniques.
△ Less
Submitted 10 December, 2020; v1 submitted 3 September, 2020;
originally announced September 2020.
-
CASTLE: performances and science cases
Authors:
S. Lombardo,
F. Prada,
E. Hugot,
S. Basa,
J. M. Bautista,
S. Boissier,
A. Boselli,
A. Bosma,
J. C. Cuillandre,
P. A. Duc,
M. Ferrari,
N. Grosso,
L. Izzo,
K. Joaquina,
Junais,
J. Koda,
A. Lamberts,
G. R. Lemaitre,
A. Longobardi,
D. Martínez-Delgado,
E. Muslimov,
J. L. Ortiz,
E. Perez,
D. Porquet,
B. Sicardy
, et al. (1 additional authors not shown)
Abstract:
We present here the Calar Alto Schmidt-Lemaitre Telescope (CASTLE) concept, a technology demonstrator for curved detectors, that will be installed at the Calar Alto Observatory (Spain). This telescope has a wide field of view (2.36x1.56 deg^2) and a design, optimised to generate a Point Spread Function with very low level wings and reduced ghost features, which makes it considerably less susceptib…
▽ More
We present here the Calar Alto Schmidt-Lemaitre Telescope (CASTLE) concept, a technology demonstrator for curved detectors, that will be installed at the Calar Alto Observatory (Spain). This telescope has a wide field of view (2.36x1.56 deg^2) and a design, optimised to generate a Point Spread Function with very low level wings and reduced ghost features, which makes it considerably less susceptible to several systematic effects usually affecting similar systems. These characteristics are particularly suited to study the low surface brightness Universe. CASTLE will be able to reach surface brightness orders of magnitude fainter than the sky background level and observe the extremely extended and faint features around galaxies such as tidal features, stellar halos, intra-cluster light, etc. CASTLE will also be used to search and detect astrophysical transients such as gamma ray bursts (GRB), gravitational wave optical counterparts, neutrino counterparts, etc. This will increase the number of precisely localized GRBs from 20% to 60% (in the case of Fermi/GMB GRBs).
△ Less
Submitted 24 June, 2020;
originally announced June 2020.
-
Next-generation telescopes with curved focal surface for ultra-low surface brightness surveys
Authors:
Simona Lombardo,
Eduard Muslimov,
Gerard Lemaître,
Emmanuel Hugot
Abstract:
In spite of major advances in both ground- and space-based instrumentation, the ultra-low-surface brightness universe (ULSB) still remains a largely unexplored volume in observational parameter space. ULSB observations provide unique constraints on a wide variety of objects, from the Zodiacal light all the way to the optical cosmological background radiation, through dust cirri, mass loss shells i…
▽ More
In spite of major advances in both ground- and space-based instrumentation, the ultra-low-surface brightness universe (ULSB) still remains a largely unexplored volume in observational parameter space. ULSB observations provide unique constraints on a wide variety of objects, from the Zodiacal light all the way to the optical cosmological background radiation, through dust cirri, mass loss shells in giant stars, LSB galaxies and the intracluster light. These surface brightness levels (>28-29 mag arcsec^-2) are observed by maximising the efficiency of the surveys and minimising or removing the systematics arising in the measurement of surface brightness. Based on full-system photon Monte Carlo simulations, we present here the performance of a ground-based telescope aimed at carrying out ULSB observations, with a curved focal surface design. Its off-axis optical design maximises the field of view while minimising the focal ratio. No lenses are used, as their multiple internal scatterings increase the wings of the point spread function (PSF), and the usual requirement of a flat focal plane is relaxed through the use of curved CCD detectors. The telescope has only one unavoidable single refractive surface, the cryostat window, and yet it delivers a PSF with ultra-compact wings, which allows the detection, for a given exposure time, of surface brightness levels nearly three orders of magnitude fainter than any other current telescope.
△ Less
Submitted 24 July, 2019;
originally announced July 2019.
-
Adaptive optics with programmable Fourier-based wavefront sensors: a spatial light modulator approach to the LOOPS testbed
Authors:
Pierre Janin-Potiron,
Vincent Chambouleyron,
Lauren Schatz,
Olivier Fauvarque,
Charlotte Z. Bond,
Yannick Abautret,
Eduard Muslimov,
Kacem El-Hadi,
Jean-François Sauvage,
Kjetil Dohlen,
Benoît Neichel,
Carlos M. Correia,
Thierry Fusco
Abstract:
Wavefront sensors encode phase information of an incoming wavefront into an intensity pattern that can be measured on a camera. Several kinds of wavefront sensors (WFS) are used in astronomical adaptive optics. Amongst them, Fourier-based wavefront sensors perform a filtering operation on the wavefront in the focal plane. The most well known example of a WFS of this kind is the Zernike wavefront s…
▽ More
Wavefront sensors encode phase information of an incoming wavefront into an intensity pattern that can be measured on a camera. Several kinds of wavefront sensors (WFS) are used in astronomical adaptive optics. Amongst them, Fourier-based wavefront sensors perform a filtering operation on the wavefront in the focal plane. The most well known example of a WFS of this kind is the Zernike wavefront sensor, and the pyramid wavefront sensor (PWFS) also belongs to this class. Based on this same principle, new WFSs can be proposed such as the n-faced pyramid (which ultimately becomes an axicone) or the flattened pyramid, depending on whether the image formation is incoherent or coherent. In order to test such novel concepts, the LOOPS adaptive optics testbed hosted at the Laboratoire d'Astrophysique de Marseille has been upgraded by adding a Spatial Light Modulator (SLM). This device, placed in a focal plane produces high-definition phase masks that mimic otherwise bulk optic devices. In this paper, we first present the optical design and upgrades made to the experimental setup of the LOOPS bench. Then, we focus on the generation of the phase masks with the SLM and the implications of having such a device in a focal plane. Finally, we present the first closed-loop results in either static or dynamic mode with different WFS applied on the SLM.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Active optics in astronomy - Freeform mirror for the MESSIER telescope proposal
Authors:
Gerard Lemaitre,
Pascal Vola,
Eduard Muslimov
Abstract:
Active optics techniques in astronomy provide high imaging quality. This paper is dedicated to highly deformable active optics that can generate non-axisymmetric aspheric surfaces-or freeform surfaces-by use of a minimum number of actuators. The aspheric mirror is obtained from a single uniform load t h a t acts over the surface of a closed-form substrate whilst under axia l reaction to its ellipt…
▽ More
Active optics techniques in astronomy provide high imaging quality. This paper is dedicated to highly deformable active optics that can generate non-axisymmetric aspheric surfaces-or freeform surfaces-by use of a minimum number of actuators. The aspheric mirror is obtained from a single uniform load t h a t acts over the surface of a closed-form substrate whilst under axia l reaction to its elliptical perimeter ring during spherical polishing. MESSIER space proposal is a wide-field low-central-obstruction folded-two-mirror-anastigmat or here called briefly three-mirror-anastigmat (TMA) telescope. The optical design is a folded reflective Schmidt. Basic telescope features are 36cm aperture, f/2.5, with 1.6 o 2.6 o field of view and a curved field detector allowing null distortion aberration for drift-scan observations. The freeform mirror is generated by spherical stress polishing that provides super-polished freeform surfaces after elastic relaxation. Preliminary analysis required use of the optics theory of 3rd-order aberrations and elasticity theory of thin elliptical plates. Final cross-optimizations were carried out with Zemax raytracing code and Nastran FEA elasticity code in order to determine the complete geometry of a glass ceramic Zerodur deformable substrate.
△ Less
Submitted 17 January, 2019;
originally announced January 2019.
-
Design and modelling of spectrographs with holographic gratings on freeform surfaces
Authors:
Eduard R. Muslimov,
Marc Ferrari,
Emmanuel Hugot,
Jean-Claude Bouret,
Coralie Neiner,
Simona Lombardo,
Gerard Lemaitre,
Robert Grange,
Ilya A. Guskov
Abstract:
In the present paper we demonstrate the approach of using a holographic grating on a freeform surface for advanced spectrographs design. We discuss the surface and groove pattern description used for ray-tracing. Moreover, we present a general procedure of diffraction efficiency calculation, which accounts for the change of hologram recording and operation conditions across the surface. The primar…
▽ More
In the present paper we demonstrate the approach of using a holographic grating on a freeform surface for advanced spectrographs design. We discuss the surface and groove pattern description used for ray-tracing. Moreover, we present a general procedure of diffraction efficiency calculation, which accounts for the change of hologram recording and operation conditions across the surface. The primary application of this approach is the optical design of the POLLUX spectropolarimeter for the LUVOR mission project where a freeform holographic grating operates simultaneously as a cross-disperser and a camera with high resolution and high dispersion. The medium ultraviolet channel design of POLLUX is considered in detail as an example. Its resolving power reaches [126,000-133,000] in the region of 118.5-195 nm. Also, we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 4000 in the region 350-550 nm and remains stable along the slit.
△ Less
Submitted 26 December, 2018;
originally announced December 2018.
-
Curved detectors developments and characterization: application to astronomical instruments
Authors:
Simona Lombardo,
Thibault Behaghel,
Bertrand Chambion,
Wilfried Jahn,
Emmanuel Hugot,
Eduard Muslimov,
Melanie Roulet,
Marc Ferrari,
Christophe Gaschet,
Stéphane Caplet,
David Henry
Abstract:
Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor t…
▽ More
Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor this can be avoided. This new technology has been gathering more and more attention from a very broad community, as the potential applications are multiple: from low-cost commercial to high impact scientific systems, to mass-market and on board cameras, defense and security, and astronomical community. We describe here the first concave curved CMOS detector developed within a collaboration between CNRS- LAM and CEA-LETI. This fully-functional detector 20 Mpix (CMOSIS CMV20000) has been curved down to a radius of Rc = 150 mm over a size of 24x32 mm^2 . We present here the methodology adopted for its characterization and describe in detail all the results obtained. We also discuss the main components of noise, such as the readout noise, the fixed pattern noise and the dark current. Finally we provide a comparison with the flat version of the same sensor in order to establish the impact of the curving process on the main characteristics of the sensor.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
Bringing high-spectral resolution to VLT/SPHERE with a fibre coupling to VLT/CRIRES+
Authors:
A. Vigan,
G. P. P. L. Otten,
E. Muslimov,
K. Dohlen,
M. W. Phillips,
U. Seemann,
J. -L. Beuzit,
R. Dorn,
M. Kasper,
D. Mouillet,
I. Baraffe,
A. Reiners
Abstract:
Atmospheric composition provides essential markers of the most fundamental properties of giant exoplanets, such as their formation mechanism or internal structure. New-generation exoplanet imagers, like VLT/SPHERE or Gemini/GPI, have been designed to achieve very high contrast (>15 mag) at small angular separations ($<$0.5\as) for the detection of young giant planets in the near-infrared, but they…
▽ More
Atmospheric composition provides essential markers of the most fundamental properties of giant exoplanets, such as their formation mechanism or internal structure. New-generation exoplanet imagers, like VLT/SPHERE or Gemini/GPI, have been designed to achieve very high contrast (>15 mag) at small angular separations ($<$0.5\as) for the detection of young giant planets in the near-infrared, but they only provide very low spectral resolutions ($R<100$) for their characterization. High-dispersion spectroscopy at resolutions up to $10^5$ is one of the most promising pathways for the detailed characterization of exoplanets, but it is currently out of reach for most directly imaged exoplanets because current high-dispersion spectrographs in the near-infrared lack coronagraphs to attenuate the stellar signal and the spatial resolution necessary to resolve the planet. Project HiRISE (High-Resolution Imaging and Spectroscopy of Exoplanets) ambitions to develop a demonstrator that will combine the capabilities of two flagship instruments installed on the ESO Very Large Telescope, the high-contrast exoplanet imager SPHERE and the high-resolution spectrograph CRIRES+, with the goal of answering fundamental questions on the formation, composition and evolution of young planets. In this work, we will present the project, the first set of realistic simulations and the preliminary design of the fiber injection unit that will be implemented in SPHERE.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Design of optical systems with toroidal curved detectors
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Marc Ferrari,
Thibault Behaghel,
Gerard R. Lemaitre,
Melanie Roulet,
Simona Lombardo
Abstract:
We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured re-imaging three-mirror anastigmat as an example (f'=960 mm, F/5.3, FoV 4x4 degrees). By assuming that the image is focused on a toroidal detector surface and perform re-optimization, it becomes pos…
▽ More
We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured re-imaging three-mirror anastigmat as an example (f'=960 mm, F/5.3, FoV 4x4 degrees). By assuming that the image is focused on a toroidal detector surface and perform re-optimization, it becomes possible to obtain a notable gain in the image quality - up to 40 % in terms of the spot RMS radius. Through analytic computations and finite-element analysis, we demonstrate that this toroidal shape can be obtained by bending of a thinned detector in a relatively simple setup.
△ Less
Submitted 21 June, 2018;
originally announced June 2018.
-
Spectrographs with holographic gratings on freeform surfaces: design approach and application for the LUVOIR mission
Authors:
Eduard Muslimov,
Marc Ferrari,
Emmanuel Hugot,
Jean-Claude Bouret,
Coralie Neiner,
Simona Lombardo,
Gerard Lemaitre,
Robert Grange
Abstract:
In the present paper we demonstrate the approach to use a holographic grating on a freeform surface for advanced spectrographs design. On the example POLLUX spectropolarimeter medium-UV channel we chow that such a grating can operate as a cross-disperser and a camera mirror at the same time. It provides the image quality high enough to reach the spectral resolving power of 126 359-133 106 between…
▽ More
In the present paper we demonstrate the approach to use a holographic grating on a freeform surface for advanced spectrographs design. On the example POLLUX spectropolarimeter medium-UV channel we chow that such a grating can operate as a cross-disperser and a camera mirror at the same time. It provides the image quality high enough to reach the spectral resolving power of 126 359-133 106 between 11.5 and 195 nm, which is higher than the requirement. Also we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 2750 for a long slit. It is also shown that the parameters of both the gratings are feasible with the current technologies.
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
Advanced optical designs of curved detectors-based two-mirrors unobscured telescopes
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Simona Lombardo,
Melanie Roulet,
Thibault Behaghel,
Marc Ferrari,
Wilfried Jahn
Abstract:
In the present paper we consider a family of unobscured telescope designs with curved detectors. They are based on classical two-mirror schemes -- Ritchey-Chretien, Gregorian and Couder telescopes. It is shown that all the designs provide nearly diffraction limited image quality in the visible domain for $.4^\circ \times .4^\circ$ field of view with the f-number of 7. We also provide a brief ghost…
▽ More
In the present paper we consider a family of unobscured telescope designs with curved detectors. They are based on classical two-mirror schemes -- Ritchey-Chretien, Gregorian and Couder telescopes. It is shown that all the designs provide nearly diffraction limited image quality in the visible domain for $.4^\circ \times .4^\circ$ field of view with the f-number of 7. We also provide a brief ghost analysis and point on special features of the systems with curved detectors. Finally, the detector surface shape obtained in each case is analyzed and its' technological feasibility is demonstrated.
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
Curved detectors for wide field imaging systems: impact on tolerance analysis
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Simona Lombardo,
Melanie Roulet,
Thibault Behaghel,
Marc Ferrari,
Wilfried Jahn,
Christophe Gaschet,
Bertrand Chambion,
David Henry
Abstract:
In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is…
▽ More
In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is a rotationally-symmetrical lens with focal length of 25 mm, f-ratio of 3.5 and field of view equal to 72$^\circ$, working in the visible domain. The second design is a three-mirror anastigmat telescope with focal length of 250 mm, f-ratio of 2.0 and field of view equal to $4^\circ \times 4^\circ$. In both of the cases use of curved detectors allow to increase the image quality and substantially decrease the requirements for manufacturing precision
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
POLLUX: a UV spectropolarimeter for the LUVOIR space telescope project
Authors:
Eduard Muslimov,
Jean-Claude Bouret,
Coralie Neiner,
Arturo López Ariste,
Marc Ferrari,
Sébastien Vivès,
Emmanuel Hugot,
Robert Grange,
Simona Lombardo,
Louise Lopes,
Josiane Costerate,
Frank Brachet
Abstract:
The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each o…
▽ More
The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each of the channels is composed of a polarimeter followed by an echelle spectrograph consisting of a classical off-axis paraboloid collimator, echelle grating with a high grooves frequency and a cross-disperser grating operating also as a camera. The latter component integrates some advanced technologies: it is a blazed grating with a complex grooves pattern formed by holographic recording, which is manufactured on a freeform surface. One of the key features underlying the current design is the large spectral length of each order ~6 nm, which allows to record wide spectral lines without any discontinuities. The modelling results show that the optical design will provide the required spectral resolving power higher than R ~ 120,000 over the entire working range for a point source object with angular size of 30 mas. It is also shown that with the 15-m primary mirror of the LUVOIR telescope the instrument will provide an effective collecting area up to 38 569 cm 2. Such a performance will allow to perform a number of groundbreaking scientific observations. Finally, the future work and the technological risks of the design are discussed in details.
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
Experimental study of an advanced concept of moderate-resolution holographic spectrographs
Authors:
Eduard Muslimov,
Gennady Valyavin,
Sergei Fabrika,
Faig Musaev,
Gazinur Galazutdinov,
Nadezhda Pavlycheva,
Eduard Emelyanov
Abstract:
We present the results of an experimental study of an advanced moderate-resolution spectrograph based on a cascade of narrow-band holographic gratings. The main goal of the project is to achieve a moderately high spectral resolutionwith R up to 5000 simultaneously in the 4300-6800 A visible spectral range on a single standard CCD, together with an increased throughput. The experimental study consi…
▽ More
We present the results of an experimental study of an advanced moderate-resolution spectrograph based on a cascade of narrow-band holographic gratings. The main goal of the project is to achieve a moderately high spectral resolutionwith R up to 5000 simultaneously in the 4300-6800 A visible spectral range on a single standard CCD, together with an increased throughput. The experimental study consisted of (1) resolution and image quality tests performed using the solar spectrum; and (2) a total throughput test performed for a number of wavelengths using a calibrated lab monochromator. The measured spectral resolving power reaches values over R>4000 while the experimental throughput is as high as 55%, which is in good agreement with the modeling results. Comparing the obtained characteristics of the spectrograph under consideration with the best existing spectrographs, we conclude that the used concept can be considered a very competitive and cheap alternative to the existing spectrographs of the given class. We propose several astrophysical applications for the instrument and discuss the prospect of creating its full-scale version.
△ Less
Submitted 17 April, 2018;
originally announced April 2018.
-
Design of pre-optics for laser guide star wavefront sensor for the ELT
Authors:
Eduard Muslimov,
Kjetil Dohlen,
Benoit Neichel,
Emmanuel Hugot
Abstract:
In the present paper, we consider the optical design of a zoom system for the active refocusing in laser guide star wavefront sensors. The system is designed according to the specifications coming from the Extremely Large Telescope (ELT)-HARMONI instrument, the first-light, integral field spectrograph for the European (E)-ELT. The system must provide a refocusing of the laser guide as a function o…
▽ More
In the present paper, we consider the optical design of a zoom system for the active refocusing in laser guide star wavefront sensors. The system is designed according to the specifications coming from the Extremely Large Telescope (ELT)-HARMONI instrument, the first-light, integral field spectrograph for the European (E)-ELT. The system must provide a refocusing of the laser guide as a function of telescope pointing and large decentring of the incoming beam. The system considers four moving lens groups, each of them being a doublet with one aspherical surface. The advantages and shortcomings of such a solution in terms of the component displacements and complexity of the surfaces are described in detail. It is shown that the system can provide the median value of the residual wavefront error of 13.8-94.3 nm and the maximum value <206 nm, while the exit pupil distortion is 0.26-0.36% for each of the telescope pointing directions.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
A fast, wide-field and distortion-free telescope with curved detectors for surveys at ultra-low surface brightness
Authors:
Eduard Muslimov,
David Valls-Gabaud,
Gérard Lemaître,
Emmanuel Hugot,
Wilfred Jahn,
Simona Lombardo,
Xin Wang,
Pascal Vola,
Marc Ferrari
Abstract:
We present the design of an all-reflective, bi-folded Schmidt telescope aimed at surveys of extended astronomical objects with extremely-low surface brightness. The design leads to a high image quality without any diffracting spider, along with a large aperture and field of view, with a small central obstruction which barely alters the PSF. As an example, we present the design of a high-quality, 3…
▽ More
We present the design of an all-reflective, bi-folded Schmidt telescope aimed at surveys of extended astronomical objects with extremely-low surface brightness. The design leads to a high image quality without any diffracting spider, along with a large aperture and field of view, with a small central obstruction which barely alters the PSF. As an example, we present the design of a high-quality, 36 cm diameter, fast ( f /2.5) telescope working in the visible with a large field of view (1.6°x 2.6°). The telescope can operate with a curved detector (or with a flat detector with a field flattener) and a set of filters. The entrance mirror is anamorphic and replaces the classical Schmidt entrance corrector plate. We show that this anamorphic primary mirror can be manufactured through stress polishing, avoiding high spatial frequency errors, and tested with a simple interferometer scheme. This prototype is intended to serve as a fast-track scientific and technological pathfinder for the future space-based MESSIER mission.
△ Less
Submitted 25 October, 2017; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Combining freeform optics and curved detectors for wide field imaging: a polynomial approach over squared aperture
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Wilfried Jahn,
Sebastien Vives,
Marc Ferrari,
Bertrand Chambion,
David Henry,
Cristophe Gaschet
Abstract:
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the m…
▽ More
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the mathematical apparatus of orthogonal polynomials defined over a square aperture, which was developed before for the tasks of wavefront reconstruction, to describe shape of a mirror surface. Two cases, namely Legendre polynomials and generalization of the Zernike polynomials on a square, are considered. The potential advantages of these polynomials sets are demonstrated on example of a three-mirror unobscured telescope with F/#=2.5 and FoV=7.2x7.2°. In addition, we discuss possibility of use of curved detectors in such a design.
△ Less
Submitted 17 June, 2017;
originally announced June 2017.
-
Combined narrowband imager-spectrograph with volume-phase holographic gratings
Authors:
Eduard R. Muslimov,
Sergei N. Fabrika,
Gennady G. Valyavin
Abstract:
In the present work we discuss a possibility to build an instrument with two operation modes - spectral and imaging ones. The key element of such instrument is a dispersive and filtering unit consisting of two narrowband volume-phase holographic gratings. Each of them provides high diffraction efficiency in a relatively narrow spectral range of a few tens of nanometers. Besides, the position of th…
▽ More
In the present work we discuss a possibility to build an instrument with two operation modes - spectral and imaging ones. The key element of such instrument is a dispersive and filtering unit consisting of two narrowband volume-phase holographic gratings. Each of them provides high diffraction efficiency in a relatively narrow spectral range of a few tens of nanometers. Besides, the position of this working band is highly dependent on the angle of incidence. So we propose to use a couple of such gratings to implement the two operational modes. The gratings are mounted in a collimated beam one after another. In the spectroscopic mode the gratings are turned on such angle that the diffraction efficiency curves coincide, thus the beams diffracted on the first grating are diffracted twice on the second one and a high-dispersion spectrum in a narrow range is formed. If the collimating and camera lenses are corrected for a wide field it is possible to use a long slit and register the spectra from its different points separately. In the imaging mode the gratings are turned to such angle that the efficiency curves intersect in a very narrow wavelength range. So the beams diffracted on the first grating are filtered out by the second one except of the spectral component, which forms the image. In this case the instrument works without slit diaphragm on the entrance. We provide an example design to illustrate the proposed concept. This optical scheme works in the region around 656 nm with F/# of 6.3. In the spectroscopic mode it provides a spectrum for the region from 641 to 671 nm with reciprocal linear dispersion of 1.4 nm/mm and the spectral resolving power higher than 14000. In the imaging mode it covers linear 12mm x 12mm field of view with spatial resolution of 15-30 lines/mm.
△ Less
Submitted 14 May, 2017;
originally announced May 2017.
-
Design and optimization of a dispersive unit based on cascaded volume phase holographic gratings
Authors:
Eduard R. Muslimov,
Gennady G. Valyavin,
Sergei N. Fabrika,
Nadezhda K. Pavlycheva
Abstract:
We describe a dispersive unit consisting of cascaded volume-phase holographic gratings for spectroscopic applications. Each of the gratings provides high diffractive efficiency in a relatively narrow wavelength range and transmits the rest of the radiation to the 0th order of diffraction. The spectral lines formed by different gratings are centered in the longitudal direction and separated in the…
▽ More
We describe a dispersive unit consisting of cascaded volume-phase holographic gratings for spectroscopic applications. Each of the gratings provides high diffractive efficiency in a relatively narrow wavelength range and transmits the rest of the radiation to the 0th order of diffraction. The spectral lines formed by different gratings are centered in the longitudal direction and separated in the transverse direction due to tilt of the gratings around two axes. We consider a technique of design and optimization of such a scheme. It allows to define modulation of index of refraction and thickness of the holographic layer for each of the gratings as well as their fringes frequencies and inclination angles. At the first stage the gratings parameters are found approximately using analytical expressions of Kogelnik's coupled wave theory. Then each of the grating starting from the longwave sub-range is optimized separately by using of numerical optimization procedure and rigorous coupled wave analysis to achieve a high diffraction efficiency profile with a steep shortwave edge. In parallel such targets as ray aiming and linear dispersion maintenance are controlled by means of ray tracing. We demonstrate this technique on example of a small-sized spectrograph for astronomical applications. It works in the range of 500-650 nm and uses three gratings covering 50 nm each. It has spectral resolution of 6130 - 12548. Obtaining of the asymmetrical efficiency curve is shown with use of dichromated gelatin and a photopolymer. Change of the curve shape allows to increase filling coefficient for the target sub-range up to 2.3 times.
△ Less
Submitted 3 May, 2017;
originally announced May 2017.
-
Advanced modelling of a moderate-resolution holographic spectrograph
Authors:
Eduard Muslimov,
Gennady Valyavin,
Sergei Fabrika,
Nadezhda Pavlycheva
Abstract:
In the present article we consider an accurate modeling of spectrograph with cascade of volume-phase holographic gratings. The proposed optical scheme allows to detect spectra in an extended wavelength range without gaps providing relatively high spectral resolution and high throughput. However, modeling and minimization of possible cross-talks between gratings and stray light in such a scheme rep…
▽ More
In the present article we consider an accurate modeling of spectrograph with cascade of volume-phase holographic gratings. The proposed optical scheme allows to detect spectra in an extended wavelength range without gaps providing relatively high spectral resolution and high throughput. However, modeling and minimization of possible cross-talks between gratings and stray light in such a scheme represents a separate task. We use analytical equations of coupled wave theory together with rigorous coupled wave analysis to optimize the gratings parameters and further apply the latter together with non-sequential raytracing algorithm to model propagation of beams through the spectrograph. The results show relatively high throughput up to 53% and absence of any significant cross-talks or ghost images even for ordinary holograms recorded on dichromated gelatin.
△ Less
Submitted 2 May, 2017;
originally announced May 2017.
-
Moderate-Resolution Holographic Spectrograph
Authors:
E. R. Muslimov,
N. K. Pavlycheva,
G. G. Valyavin,
S. N. Fabrika
Abstract:
We present a new scheme of a moderate-resolution spectrograph based on a cascade of serial holographic gratings each of which produces an individual spectrum with a resolution of about 6000 and a bandwidth of 80 nm. The gratings ensure centering of each part of the spectrum they produce so as to provide uniform coverage of the broadest possible wavelength interval. In this study we manage to simul…
▽ More
We present a new scheme of a moderate-resolution spectrograph based on a cascade of serial holographic gratings each of which produces an individual spectrum with a resolution of about 6000 and a bandwidth of 80 nm. The gratings ensure centering of each part of the spectrum they produce so as to provide uniform coverage of the broadest possible wavelength interval. In this study we manage to simultaneously cover the 430-680 nm interval without gaps using three gratings. Efficiency of the spectrograph optical system itself from the entrance slit to the CCD detector is typically of about 60 % with a maximum of 75 %. We discuss the advantages and drawbacks of the new spectrograph scheme as well as the astrophysical tasks for which the instrument can be used.
△ Less
Submitted 3 January, 2017;
originally announced January 2017.
-
Design and modeling of a moderate-resolution astronomic spectrograph with volume-phase holographic gratings
Authors:
Eduard R. Muslimov,
Gennady G. Valyavin,
Sergey N. Fabrika,
Nadezhda K. Pavlycheva
Abstract:
We present an optical design of astronomic spectrograph based on a cascade of volume-phase holographic gratings. The cascade consists of three gratings. Each of them provides moderately high spectral resolution in a narrow range of 83 nm. Thus the spectrum image represents three lines covering region 430-680 nm. Two versions of the scheme are described: a full-scale one with estimated resolving po…
▽ More
We present an optical design of astronomic spectrograph based on a cascade of volume-phase holographic gratings. The cascade consists of three gratings. Each of them provides moderately high spectral resolution in a narrow range of 83 nm. Thus the spectrum image represents three lines covering region 430-680 nm. Two versions of the scheme are described: a full-scale one with estimated resolving power of 5300-7900 and a small-sized one intended for creation of a lab prototype, which provides the resolving power of 1500-3000. Diffraction efficiency modeling confirms that the system throughput can reach 75 %, while stray light caused by the gratings crosstalk is negligible. We also propose a design of image slicer and focal reducer allowing to couple the instrument with the 6-m telescope. Finally, we present concept of the opto-mechanical design.
△ Less
Submitted 14 August, 2016;
originally announced August 2016.