Spectroscopic Performance of Detectors for Athena's WFI: Measurements and Simulation
Authors:
Johannes Müller-Seidlitz,
Robert Andritschke,
Valentin Emberger,
Michael Bonholzer,
Günter Hauser,
Peter Lechner,
Astrid Mayr,
Jonas Reiffers,
Anna Schweingruber,
Wolfgang Treberspurg
Abstract:
The depleted p-channel field effect transistor is the chosen sensor type for the Wide Field Imager of the Athena mission. It will be used in two types of cameras. One will enable observations of a field of view of 40' x 40' by using an array of four 512 x 512 pixel sensors in a 2 x 2 configuration. A second, small one is designed to investigate bright, point-like sources with a time resolution of…
▽ More
The depleted p-channel field effect transistor is the chosen sensor type for the Wide Field Imager of the Athena mission. It will be used in two types of cameras. One will enable observations of a field of view of 40' x 40' by using an array of four 512 x 512 pixel sensors in a 2 x 2 configuration. A second, small one is designed to investigate bright, point-like sources with a time resolution of up to 40 microseconds. Sensors of final size, layout, and technology were fabricated, assembled and characterised. Also, first results from the flight production are available and confirm the excellent performance. In order to be able to estimate the future performance of degraded detectors, a simulation was developed that takes into account the non-analytical threshold effects on the basis of measurement results. We present the measurement analysis and the comparison of simulated and measured values as well as first attempts to use the Monte Carlo simulation to predict performance results based on noise measurements.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
Low temperature proton irradiation with DEPFETs for Athena's Wide Field Imager
Authors:
Valentin Emberger,
Robert Andritschke,
Parviz Azhdarzadeh,
Günter Hauser,
Astrid Mayr,
Johannes Müller-Seidlitz,
Abbas Rezaei,
Wolfgang Treberer-Treberspurg
Abstract:
The Wide Field Imager (WFI), one of two instruments on ESA's next large X-ray mission Athena, is designed for imaging spectroscopy of X-rays in the range of 0.2 to 15 keV with a large field of view and high count rate capability. The focal plane consists of back-illuminated DEPFET (Depleted p-channel field effect transistor) sensors that have a high radiation tolerance and provide a near Fano-limi…
▽ More
The Wide Field Imager (WFI), one of two instruments on ESA's next large X-ray mission Athena, is designed for imaging spectroscopy of X-rays in the range of 0.2 to 15 keV with a large field of view and high count rate capability. The focal plane consists of back-illuminated DEPFET (Depleted p-channel field effect transistor) sensors that have a high radiation tolerance and provide a near Fano-limited energy resolution. To achieve this, a very low noise readout is required, about 3 electrons ENC at beginning of life is foreseen. This makes the device very susceptible to any radiation induced worsening of the readout noise. The main mechanism of degradation will be the increase of dark current due to displacement damage caused primarily by high energy protons. To study the expected performance degradation, a prototype detector module with fully representative pixel layout and fabrication technology was irradiated with 62.4 MeV protons at the accelerator facility MedAustron in Wiener Neustadt. A total dose equivalent to 3.3 $\textstyle{10^{9}}$ 10-MeV protons/$\mathrm{cm^{2}}$ was applied in two steps. During, in-between and after the irradiations the detector remained at the operating temperature of 213 K and was fully biased and operated. Data was recorded to analyze the signal of all incident particles. We report on the increase of dark current after the irradiation and present the current related damage rate at 213 K. The effect of low temperature annealing at 213 K , 236 K, 253 K, 273 K, and 289 K is presented.
△ Less
Submitted 2 July, 2024; v1 submitted 28 June, 2024;
originally announced June 2024.
-
Spectroscopic performance of flight-like DEPFET sensors for Athena's WFI
Authors:
Johannes Müller-Seidlitz,
Robert Andritschke,
Michael Bonholzer,
Valentin Emberger,
Günter Hauser,
Maximilian Herrmann,
Peter Lechner,
Astrid Mayr,
Julian Oser
Abstract:
The Wide Field Imager for the Athena X-ray telescope is composed of two back side illuminated detectors using DEPFET sensors operated in rolling shutter readout mode: A large detector array featuring four sensors with 512x512 pixels each and a small detector that facilitates the high count rate capability of the WFI for the investigation of bright, point-like sources. Both sensors were fabricated…
▽ More
The Wide Field Imager for the Athena X-ray telescope is composed of two back side illuminated detectors using DEPFET sensors operated in rolling shutter readout mode: A large detector array featuring four sensors with 512x512 pixels each and a small detector that facilitates the high count rate capability of the WFI for the investigation of bright, point-like sources. Both sensors were fabricated in full size featuring the pixel layout, fabrication technology and readout mode chosen in a preceding prototy** phase. We present the spectroscopic performance of these flight-like detectors for different photon energies in the relevant part of the targeted energy range from 0.2 keV to 15 keV with respect to the timing requirements of the instrument. For 5.9 keV photons generated by an iron-55 source the spectral performance expressed as Full Width at Half Maximum of the emission peak in the spectrum is 126.0 eV for the Large Detector and 129.1 eV for the Fast Detector. A preliminary analysis of the camera's signal chain also allows for a first prediction of the performance in space at the end of the nominal operation phase.
△ Less
Submitted 8 August, 2022;
originally announced August 2022.