-
Ultra-sensitive Super-THz Microwave Kinetic Inductance Detectors for future space telescopes
Authors:
J. J. A. Baselmans,
F. Facchin,
A. Pascual Laguna,
J. Bueno,
D. J. Thoen,
V. Murugesan,
N. Llombart,
P. de Visser
Abstract:
Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in observing speed of many orders of magnitude. A spectroscopic instrument on such an observatory requires large arrays of detectors with a sensitivity expressed as a n…
▽ More
Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in observing speed of many orders of magnitude. A spectroscopic instrument on such an observatory requires large arrays of detectors with a sensitivity expressed as a noise equivalent power NEP = 3 $\times 10^{-20}$ $W\surd{Hz}$. We present the design, fabrication, and characterisation of microwave kinetic inductance detectors (MKIDs) for this frequency range reaching the required sensitivity. The devices are based on thin-film NbTiN resonators which use lens-antenna coupling to a submicron-width aluminium transmission line at the shorted end of the resonator where the radiation is absorbed. We optimised the MKID geometry for a low NEP by using a small aluminium volume of $\approx$ 1$μm^3$ and fabricating the aluminium section on a very thin (100 nm) SiN membrane. Both methods of optimisation also reduce the effect of excess noise by increasing the responsivity of the device, which is further increased by reducing the parasitic geometrical inductance of the resonator. We measure the sensitivity of eight MKIDs with respect to the power absorbed in the detector using a thermal calibration source filtered in a narrow band around 1.55 THz. We obtain a NEP$_{exp}(P_{abs})\:=\:3.1\pm0.9\times10^{-20}\:W\surd{Hz}$ at a modulation frequency of 200 Hz averaged over all measured MKIDs. The NEP is limited by quasiparticle trap**. The measured sensitivity is sufficient for spectroscopic observations from future, actively cooled space-based observatories. Moreover, the presented device design and assembly can be adapted for frequencies up to $\approx$ 10 THz and can be readily implemented in kilopixel arrays.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
DESHIMA 2.0: development of an integrated superconducting spectrometer for science-grade astronomical observations
Authors:
Akio Taniguchi,
Tom J. L. C. Bakx,
Jochem J. A. Baselmans,
Robert Huiting,
Kenichi Karatsu,
Nuria Llombart,
Matus Rybak,
Tatsuya Takekoshi,
Yoichi Tamura,
Hiroki Akamatsu,
Stefanie Brackenhoff,
Juan Bueno,
Bruno T. Buijtendorp,
Shahab Dabironezare,
Anne-Kee Doing,
Yasunori Fujii,
Kazuyuki Fujita,
Matthijs Gouwerok,
Sebastian Hähnle,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Tetsu Kitayama,
Kotaro Kohno,
Akira Kouchi
, et al. (10 additional authors not shown)
Abstract:
Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed…
▽ More
Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed to observe the 220-440 GHz band in a single shot, corresponding to a redshift range of $z$=3.3-7.6 for the ionized carbon emission ([C II] 158 $μ$m). The first-light experiment of DESHIMA 1.0, using the 332-377 GHz band, has shown an excellent agreement among the on-sky measurements, the lab measurements, and the design. As a successor to DESHIMA 1.0, we plan the commissioning and the scientific observation campaign of DESHIMA 2.0 on the ASTE 10-m telescope in 2023. Ongoing upgrades for the full octave-bandwidth system include the wideband 347-channel chip design and the wideband quasi-optical system. For efficient measurements, we also develop the observation strategy using the mechanical fast sky-position chopper and the sky-noise removal technique based on a novel data-scientific approach. In the paper, we show the recent status of the upgrades and the plans for the scientific observation campaign.
△ Less
Submitted 4 October, 2022; v1 submitted 27 October, 2021;
originally announced October 2021.
-
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer
Authors:
Tatsuya Takekoshi,
Kenichi Karatsu,
Junya Suzuki,
Yoichi Tamura,
Tai Oshima,
Akio Taniguchi,
Shin'ichiro Asayama,
Tom J. L. C. Bakx,
Jochem J. A. Baselmans,
Sjoerd Bosma,
Juan Bueno,
Kah Wuy Chin,
Yasunori Fujii,
Kazuyuki Fujita,
Robert Huiting,
Soh Ikarashi,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Teun M. Klapwijk,
Kotaro Kohno,
Akira Kouchi,
Nuria Llombart,
Jun Maekawa,
Vignesh Murugesan
, et al. (14 additional authors not shown)
Abstract:
We are develo** an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope.…
▽ More
We are develo** an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1σ=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
First light demonstration of the integrated superconducting spectrometer
Authors:
Akira Endo,
Kenichi Karatsu,
Yoichi Tamura,
Tai Oshima,
Akio Taniguchi,
Tatsuya Takekoshi,
Shin'ichiro Asayama,
Tom J. L. C. Bakx,
Sjoerd Bosma,
Juan Bueno,
Kah Wuy Chin,
Yasunori Fujii,
Kazuyuki Fujita,
Robert Huiting,
Soh Ikarashi,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Teun M. Klapwijk,
Kotaro Kohno,
Akira Kouchi,
Nuria Llombart,
Jun Maekawa,
Vignesh Murugesan,
Shunichi Nakatsubo
, et al. (14 additional authors not shown)
Abstract:
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pix…
▽ More
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pixels (>$10^2$). Here we present the design and first astronomical spectra of an intrinsically scalable, integrated superconducting spectrometer, which covers 332-377 GHz with a spectral resolution of $F/ΔF \sim 380$. It combines the multiplexing advantage of microwave kinetic inductance detectors (MKIDs) with planar superconducting filters for dispersing the signal in a single, small superconducting integrated circuit. We demonstrate the two key applications for an instrument of this type: as an efficient redshift machine, and as a fast multi-line spectral mapper of extended areas. The line detection sensitivity is in excellent agreement with the instrument design and laboratory performance, reaching the atmospheric foreground photon noise limit on sky. The design can be scaled to bandwidths in excess of an octave, spectral resolution up to a few thousand and frequencies up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$ allows for compact multi-pixel spectral imagers, which would enable spectroscopic direct imaging and large volume spectroscopic surveys that are several orders of magnitude faster than what is currently possible.
△ Less
Submitted 18 September, 2019; v1 submitted 24 June, 2019;
originally announced June 2019.
-
Wideband on-chip terahertz spectrometer based on a superconducting filterbank
Authors:
Akira Endo,
Kenichi Karatsu,
Alejandro Pascual Laguna,
Behnam Mirzaei,
Robert Huiting,
David J. Thoen,
Vignesh Murugesan,
Stephen J. C. Yates,
Juan Bueno,
Nuri van Marrewijk,
Sjoerd Bosma,
Ozan Yurduseven,
Nuria Llombart,
Junya Suzuki,
Masato Naruse,
Pieter J. de Visser,
Paul P. van der Werf,
Teun M. Klapwijk,
Jochem J. A. Baselmans
Abstract:
Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinet…
▽ More
Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinetic inductance detector behind each filter. Using frequency division multiplexing, all detectors are read-out simultaneously creating a wide-band spectrometer with an instantaneous bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral resolution of $F/ΔF=380$ and reaches photon-noise limited sensitivity. We discuss the chip design and fabrication, as well as the system integration and testing. We confirm full system operation by the detection of an emission line spectrum of methanol gas. The proposed concept allows for spectroscopic radiation detection over large bandwidths and resolutions up to $F/ΔF\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the construction of medium resolution imaging spectrometers with unprecedented speed and sensitivity.
△ Less
Submitted 21 June, 2019; v1 submitted 21 January, 2019;
originally announced January 2019.
-
Eliminating stray radiation inside large area imaging arrays
Authors:
Stephen J. C. Yates,
Simon Doyle,
Peter Barry,
Andrey M. Baryshev,
Juan Bueno,
Lorenza Ferrari,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Ozan Yurduseven,
Jochem J. A. Baselmans
Abstract:
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a poin…
▽ More
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Surface wave control for large arrays of microwave kinetic inductance detectors
Authors:
Stephen J. C. Yates,
Andrey M. Baryshev,
Ozan Yurduseven,
Juan Bueno,
Kristina K. Davis,
Lorenza Ferrari,
Willem Jellema,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Jochem J. A. Baselmans
Abstract:
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic I…
▽ More
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.
△ Less
Submitted 7 July, 2017;
originally announced July 2017.
-
A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
Authors:
J. J. A. Baselmans,
J. Bueno,
S. J. C. Yates,
O. Yurduseven,
N. Llombart,
K. Karatsu,
A. M. Baryshev,
L. Ferrari,
A. Endo,
D. J. Thoen,
P. J. de Visser,
R. M. J. Janssen,
V. Murugesan,
E. F. C. Driessen,
G. Coiffard,
J. Martin-Pintado,
P. Hargrave,
M. Griffin
Abstract:
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel ima…
▽ More
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.
△ Less
Submitted 1 March, 2017; v1 submitted 7 September, 2016;
originally announced September 2016.
-
The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
Authors:
P. J. de Visser,
S. J. C. Yates,
T. Guruswamy,
D. J. Goldie,
S. Withington,
A. Neto,
N. Llombart,
A. M. Baryshev,
T. M. Klapwijk,
J. J. A. Baselmans
Abstract:
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice…
▽ More
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trap** of pair-breaking phonons in the superconductor. In practice this is the first measurement of the frequency dependence of the quasiparticle creation efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.
△ Less
Submitted 22 May, 2015;
originally announced May 2015.
-
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Authors:
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
D. Barkats,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
I. Buder,
E. Bullock,
G. Chattopadhyay,
G. Davis,
P. K. Day,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
S. R. Hildebrandt,
G. C. Hilton,
V. Hristov,
H. Hui
, et al. (42 additional authors not shown)
Abstract:
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays…
▽ More
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at 95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ~0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the SPIDER instrument, and development of this technology is ongoing.
△ Less
Submitted 2 February, 2015;
originally announced February 2015.
-
BICEP2 II: Experiment and Three-Year Data Set
Authors:
BICEP2 Collaboration,
P. A. R Ade,
R. W. Aikin,
M. Amiri,
D. Barkats,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Brevik,
I. Buder,
E. Bullock,
G. Davis,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
S. R. Hildebrandt,
G. C. Hilton,
V. V. Hristov,
K. D. Irwin,
K. S. Karkare,
J. P. Kaufman
, et al. (27 additional authors not shown)
Abstract:
We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1 to 5 degrees ($\ell$=40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvem…
▽ More
We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1 to 5 degrees ($\ell$=40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26~cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 $μ$K sqrt(s). The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.2 $μ$K arcmin) over an effective area of 384 square degrees within a 1000 square degree field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.
△ Less
Submitted 31 July, 2014; v1 submitted 17 March, 2014;
originally announced March 2014.
-
Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime
Authors:
L. J. Swenson,
P. K. Day,
B. H. Eom,
H. G. Leduc,
N. Llombart,
C. M. McKenney,
O. Noroozian,
J. Zmuidzinas
Abstract:
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven…
▽ More
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven fairly hard in order to optimize their sensitivity, most experiments to date have not explored detector performance beyond the onset of bifurcation. Here we present measurements of a lumped-element superconducting microresonator designed for use as a far-infrared detector and operated deep into the nonlinear regime. The 1 GHz resonator was fabricated from a 22 nm thick titanium nitride film with a critical temperature of 2 K and a normal-state resistivity of $100\, μΩ\,$cm. We measured the response of the device when illuminated with 6.4 pW optical loading using microwave readout powers that ranged from the low-power, linear regime to 18 dB beyond the onset of bifurcation. Over this entire range, the nonlinear behavior is well described by a nonlinear kinetic inductance. The best noise-equivalent power of $2 \times 10^{-16}$ W/Hz$^{1/2}$ at 10 Hz was measured at the highest readout power, and represents a $\sim$10 fold improvement compared with operating below the onset of bifurcation.
△ Less
Submitted 18 May, 2013;
originally announced May 2013.
-
MKID development for SuperSpec: an on-chip, mm-wave, filter-bank spectrometer
Authors:
Erik Shirokoff,
Peter S. Barry,
Charles M. Bradford,
Goutam Chattopadhyay,
Peter Day,
Simon Doyle,
Steve Hailey-Dunsheath,
Matthew I. Hollister,
Attila Kovács,
Christopher McKenney,
Henry G. Leduc,
Nuria Llombart,
Daniel P. Marrone,
Philip Mauskopf,
Roger O'Brient,
Stephen Padin,
Theodore Reck,
Loren J. Swenson,
Jonas Zmuidzinas
Abstract:
SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and submillimeter wavelength astronomy. Its very small size, wide spectral bandwidth, and highly multiplexed readout will enable construction of powerful multibeam spectrometers for high-redshift observations. The spectrometer consists of a horn-coupled microstrip feedline, a bank of narrow-band superconducting resonator filters t…
▽ More
SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and submillimeter wavelength astronomy. Its very small size, wide spectral bandwidth, and highly multiplexed readout will enable construction of powerful multibeam spectrometers for high-redshift observations. The spectrometer consists of a horn-coupled microstrip feedline, a bank of narrow-band superconducting resonator filters that provide spectral selectivity, and Kinetic Inductance Detectors (KIDs) that detect the power admitted by each filter resonator. The design is realized using thin-film lithographic structures on a silicon wafer. The mm-wave microstrip feedline and spectral filters of the first prototype are designed to operate in the band from 195-310 GHz and are fabricated from niobium with at Tc of 9.2K. The KIDs are designed to operate at hundreds of MHz and are fabricated from titanium nitride with a Tc of 2K. Radiation incident on the horn travels along the mm-wave microstrip, passes through the frequency-selective filter, and is finally absorbed by the corresponding KID where it causes a measurable shift in the resonant frequency. In this proceedings, we present the design of the KIDs employed in SuperSpec and the results of initial laboratory testing of a prototype device. We will also briefly describe the ongoing development of a demonstration instrument that will consist of two 500-channel, R=700 spectrometers, one operating in the 1-mm atmospheric window and the other covering the 650 and 850 micron bands.
△ Less
Submitted 7 November, 2012;
originally announced November 2012.
-
SuperSpec: design concept and circuit simulations
Authors:
Attila Kovács,
Peter S. Barry,
Charles M. Bradford,
Goutam Chattopadhyay,
Peter Day,
Simon Doyle,
Steve Hailey-Dunsheath,
Matthew Hollister,
Christopher McKenney,
Henry G. LeDuc,
Nuria Llombart,
Daniel P. Marrone,
Philip Mauskopf,
Roger O'Brient,
Stephen Padin,
Loren J. Swenson,
Jonas Zmuidzinas
Abstract:
SuperSpec is a pathfinder for future lithographic spectrometer cameras, which promise to energize extra-galactic astrophysics at (sub)millimeter wavelengths: delivering 200--500 km/s spectral velocity resolution over an octave bandwidth for every pixel in a telescope's field of view. We present circuit simulations that prove the concept, which enables complete millimeter-band spectrometer devices…
▽ More
SuperSpec is a pathfinder for future lithographic spectrometer cameras, which promise to energize extra-galactic astrophysics at (sub)millimeter wavelengths: delivering 200--500 km/s spectral velocity resolution over an octave bandwidth for every pixel in a telescope's field of view. We present circuit simulations that prove the concept, which enables complete millimeter-band spectrometer devices in just a few square-millimeter footprint. We evaluate both single-stage and two-stage channelizing filter designs, which separate channels into an array of broad-band detectors, such as bolometers or kinetic inductance detector (KID) devices. We discuss to what degree losses (by radiation or by absorption in the dielectric) and fabrication tolerances affect the resolution or performance of such devices, and what steps we can take to mitigate the degradation. Such design studies help us formulate critical requirements on the materials and fabrication process, and help understand what practical limits currently exist to the capabilities these devices can deliver today or over the next few years.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Authors:
A. Orlando,
R. W Aikin,
M. Amiri,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Chattopadthyay,
P. K. Day,
J. P. Filippini,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
K. D. Irwin,
M. Kenyon,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
H. G. LeDuc,
N. Llombart,
H. T. Nguyen,
R. W. Ogburn,
C. D. Reintsema,
M. C. Runyan
, et al. (6 additional authors not shown)
Abstract:
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled t…
▽ More
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled together to make a focal plane, for a total of 256 dual-polarization elements (512 TES sensors). The detector arrays are integrated with a time-domain SQUID multiplexer developed at NIST and read out using the multi-channels electronics (MCE) developed at the University of British Columbia. Following our progress in improving detector parameters uniformity across the arrays and fabrication yield, our main effort has focused on improving detector arrays optical and noise performances, in order to produce science grade focal planes achieving target sensitivities. We report on changes in detector design implemented to optimize such performances and following focal plane arrays characterization. BICEP2 has deployed a first 150 GHz science grade focal plane to the South Pole in December 2009.
△ Less
Submitted 19 September, 2010;
originally announced September 2010.