Neutron Tagging following Atmospheric Neutrino Events in a Water Cherenkov Detector
Authors:
K. Abe,
Y. Haga,
Y. Hayato,
K. Hiraide,
K. Ieki,
M. Ikeda,
S. Imaizumi,
K. Iyogi,
J. Kameda,
Y. Kanemura,
Y. Kataoka,
Y. Kato,
Y. Kishimoto,
S. Miki,
S. Mine,
M. Miura,
T. Mochizuki,
S. Moriyama,
Y. Nagao,
M. Nakahata,
T. Nakajima,
Y. Nakano,
S. Nakayama,
T. Okada,
K. Okamoto
, et al. (281 additional authors not shown)
Abstract:
We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agr…
▽ More
We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218 \pm 9 μs.
△ Less
Submitted 20 September, 2022; v1 submitted 18 September, 2022;
originally announced September 2022.
-
Real-Time Supernova Neutrino Burst Monitor at Super-Kamiokande
Authors:
K. Abe,
Y. Haga,
Y. Hayato,
M. Ikeda,
K. Iyogi,
J. Kameda,
Y. Kishimoto,
M. Miura,
S. Moriyama,
M. Nakahata,
Y. Nakano,
S. Nakayama,
H. Sekiya,
M. Shiozawa,
Y. Suzuki,
A. Takeda,
H. Tanaka,
T. Tomura,
K. Ueno,
R. A. Wendell,
T. Yokozawa,
T. Irvine,
T. Kajita,
I. Kametani,
K. Kaneyuki
, et al. (102 additional authors not shown)
Abstract:
We present a real-time supernova neutrino burst monitor at Super-Kamiokande (SK). Detecting supernova explosions by neutrinos in real time is crucial for giving a clear picture of the explosion mechanism. Since the neutrinos are expected to come earlier than light, a fast broadcasting of the detection may give astronomers a chance to make electromagnetic radiation observations of the explosions ri…
▽ More
We present a real-time supernova neutrino burst monitor at Super-Kamiokande (SK). Detecting supernova explosions by neutrinos in real time is crucial for giving a clear picture of the explosion mechanism. Since the neutrinos are expected to come earlier than light, a fast broadcasting of the detection may give astronomers a chance to make electromagnetic radiation observations of the explosions right at the onset. The role of the monitor includes a fast announcement of the neutrino burst detection to the world and a determination of the supernova direction. We present the online neutrino burst detection system and studies of the direction determination accuracy based on simulations at SK.
△ Less
Submitted 11 April, 2016; v1 submitted 18 January, 2016;
originally announced January 2016.
-
Calibration of the Super-Kamiokande Detector
Authors:
K. Abe,
Y. Hayato,
T. Iida,
K. Iyogi,
J. Kameda,
Y. Kishimoto,
Y. Koshio,
Ll. Marti,
M. Miura,
S. Moriyama,
M. Nakahata,
Y. Nakano,
S. Nakayama,
Y. Obayashi,
H. Sekiya,
M. Shiozawa,
Y. Suzuki,
A. Takeda,
Y. Takenaga,
H. Tanaka,
T. Tomura,
K. Ueno,
R. A. Wendell,
T. Yokozawa,
T. J. Irvine
, et al. (108 additional authors not shown)
Abstract:
Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret th…
▽ More
Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret the digitized output of our electronics so that we can obtain physical numbers such as photon counts and their arrival times for each photomultiplier tube (PMT). In this context, we developed an in-situ procedure to determine high-voltage settings for PMTs in large detectors like SK, as well as a new method for measuring PMT quantum efficiency and gain in such a detector. The second part describes the modeling of the detector in our Monte Carlo simulation, including in particular the optical properties of its water target and their variability over time. Detailed studies on the water quality are also presented. As a result of this work, we achieved a precision sufficient for physics analysis over a wide energy range (from a few MeV to above a TeV). For example, the charge determination was understood at the 1% level, and the timing resolution was 2.1 nsec at the one-photoelectron charge level and 0.5 nsec at the 100-photoelectron charge level.
△ Less
Submitted 20 December, 2013; v1 submitted 29 June, 2013;
originally announced July 2013.
-
Letter of Intent: The Hyper-Kamiokande Experiment --- Detector Design and Physics Potential ---
Authors:
K. Abe,
T. Abe,
H. Aihara,
Y. Fukuda,
Y. Hayato,
K. Huang,
A. K. Ichikawa,
M. Ikeda,
K. Inoue,
H. Ishino,
Y. Itow,
T. Kajita,
J. Kameda,
Y. Kishimoto,
M. Koga,
Y. Koshio,
K. P. Lee,
A. Minamino,
M. Miura,
S. Moriyama,
M. Nakahata,
K. Nakamura,
T. Nakaya,
S. Nakayama,
K. Nishijima
, et al. (16 additional authors not shown)
Abstract:
We propose the Hyper-Kamiokande (Hyper-K) detector as a next generation underground water Cherenkov detector. It will serve as a far detector of a long baseline neutrino oscillation experiment envisioned for the upgraded J-PARC, and as a detector capable of observing -- far beyond the sensitivity of the Super-Kamiokande (Super-K) detector -- proton decays, atmospheric neutrinos, and neutrinos from…
▽ More
We propose the Hyper-Kamiokande (Hyper-K) detector as a next generation underground water Cherenkov detector. It will serve as a far detector of a long baseline neutrino oscillation experiment envisioned for the upgraded J-PARC, and as a detector capable of observing -- far beyond the sensitivity of the Super-Kamiokande (Super-K) detector -- proton decays, atmospheric neutrinos, and neutrinos from astronomical origins. The baseline design of Hyper-K is based on the highly successful Super-K, taking full advantage of a well-proven technology. (to be continued)
△ Less
Submitted 15 September, 2011;
originally announced September 2011.