-
Axion Dark Matter eXperiment: Run 1A Analysis Details
Authors:
C. Boutan,
B. H. LaRoque,
E. Lentz,
N. S. Oblath,
M. S. Taubman,
J. Tedeschi,
J. Yang,
A. M. Jones,
T. Braine,
N. Crisosto,
L. J Rosenberg,
G. Rybka,
D. Will,
D. Zhang,
S. Kimes,
R. Ottens,
C. Bartram,
D. Bowring,
R. Cervantes,
A. S. Chou,
S. Knirck,
D. V. Mitchell,
A. Sonnenschein,
W. Wester,
R. Khatiwada
, et al. (28 additional authors not shown)
Abstract:
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower…
▽ More
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Search for 70 μeV Dark Photon Dark Matter with a Dielectrically-Loaded Multi-Wavelength Microwave Cavity
Authors:
R. Cervantes,
G. Carosi,
C. Hanretty,
S. Kimes,
B. H. LaRoque,
G. Leum,
P. Mohapatra,
N. S. Oblath,
R. Ottens,
Y. Park,
G. Rybka,
J. Sinnis,
J. Yang
Abstract:
Microwave cavities have been deployed to search for bosonic dark matter candidates with masses of a few $μ$eV. However, the sensitivity of these cavity detectors is limited by their volume, and the traditionally-employed half-wavelength cavities suffer from a significant volume reduction at higher masses. ADMX-Orpheus mitigates this issue by operating a tunable, dielectrically-loaded cavity at a h…
▽ More
Microwave cavities have been deployed to search for bosonic dark matter candidates with masses of a few $μ$eV. However, the sensitivity of these cavity detectors is limited by their volume, and the traditionally-employed half-wavelength cavities suffer from a significant volume reduction at higher masses. ADMX-Orpheus mitigates this issue by operating a tunable, dielectrically-loaded cavity at a higher-order mode, which allows the detection volume to remain large. The ADMX-Orpheus inaugural run excludes dark photon dark matter with kinetic mixing angle $χ> 10^{-13}$ between 65.5 $μ$eV (15.8 GHz) and 69.3 $μ$eV (16.8GHz), marking the highest-frequency tunable microwave cavity dark matter search to date.
△ Less
Submitted 9 November, 2022; v1 submitted 7 April, 2022;
originally announced April 2022.
-
Axion Dark Matter eXperiment: Detailed Design and Operations
Authors:
R. Khatiwada,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
D. V. Mitchell,
T. Braine,
C. Bartram,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Will,
G. Carosi,
N. Woollett,
S. Durham,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath
, et al. (26 additional authors not shown)
Abstract:
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technolog…
▽ More
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.
△ Less
Submitted 30 September, 2020;
originally announced October 2020.
-
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
Authors:
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
M. S. Taubman,
J. Clarke,
A. Dove,
A. Eddins
, et al. (17 additional authors not shown)
Abstract:
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode c…
▽ More
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.
△ Less
Submitted 1 November, 2019; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Authors:
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
R. Cervantes,
N. Du,
N. Force,
S. Kimes,
R. Ottens,
L. J. Rosenberg,
G. Rybka,
J. Yang,
G. Carosi,
N. Woollett,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
R. Bradley,
E. J. Daw,
A. Agrawal,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley
, et al. (9 additional authors not shown)
Abstract:
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, highe…
▽ More
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.