-
High count rate effects in event processing for XRISM/Resolve x-ray microcalorimeter
Authors:
Misaki Mizumoto,
Masahiro Tsujimoto,
Renata S. Cumbee,
Megan E. Eckart,
Yoshitaka Ishisaki,
Caroline A. Kilbourne,
Edmund Hodges-Kluck,
Maurice A. Leutenegger,
Frederick S. Porter,
Makoto Sawada,
Yoh Takei,
Yuusuke Uchida,
Shin'ya Yamada,
the XRISM Resolve team
Abstract:
The spectroscopic performance of x-ray instruments can be affected at high count rates. The effects and mitigation in the optical chain, such as x-ray attenuation filters or de-focusing mirrors, are widely discussed, but those in the signal chain are not. Using the Resolve x-ray microcalorimeter onboard the XRISM satellite, we discuss the effects observed during high count rate measurements and ho…
▽ More
The spectroscopic performance of x-ray instruments can be affected at high count rates. The effects and mitigation in the optical chain, such as x-ray attenuation filters or de-focusing mirrors, are widely discussed, but those in the signal chain are not. Using the Resolve x-ray microcalorimeter onboard the XRISM satellite, we discuss the effects observed during high count rate measurements and how these can be modeled. We focus on three instrumental effects that impact performance at high count rate: CPU limit, pile up, and electrical cross talk. High count rate data were obtained during ground testing using the flight model instrument and a calibration x-ray source. A simulated observation of GX 13+1 is presented to illustrate how to estimate these effects based on these models for observation planning. The impact of these effects on high count rate observations is discussed.
△ Less
Submitted 24 December, 2023;
originally announced December 2023.
-
Properties of the Line-of-Sight Velocity Field in the Hot and X-ray Emitting Circumgalactic Medium of Nearby Simulated Disk Galaxies
Authors:
J. A. ZuHone,
G. Schellenberger,
A. Ogorzalek,
B. D. Oppenheimer,
J. Stern,
A. Bogdan,
N. Truong,
M. Markevitch,
A. Pillepich,
D. Nelson,
J. N. Burchett,
I. Khabibullin,
C. A. Kilbourne,
R. P. Kraft,
P. E. J. Nulsen,
S. Veilleux,
M. Vogelsberger,
Q. D. Wang,
I. Zhuravleva
Abstract:
The hot, X-ray-emitting phase of the circumgalactic medium of massive galaxies is believed to be the reservoir of baryons from which gas flows onto the central galaxy and into which feedback from AGN and stars inject mass, momentum, energy, and metals. These effects shape the velocity fields of the hot gas, which can be observed via the Doppler shifting and broadening of emission lines by X-ray IF…
▽ More
The hot, X-ray-emitting phase of the circumgalactic medium of massive galaxies is believed to be the reservoir of baryons from which gas flows onto the central galaxy and into which feedback from AGN and stars inject mass, momentum, energy, and metals. These effects shape the velocity fields of the hot gas, which can be observed via the Doppler shifting and broadening of emission lines by X-ray IFUs. In this work, we analyze the gas kinematics of the hot circumgalactic medium of Milky Way-mass disk galaxies from the TNG50 simulation with synthetic observations to determine how future instruments can probe this velocity structure. We find that the hot phase is often characterized by outflows from the disk driven by feedback processes, radial inflows near the galactic plane, and rotation, though in some systems the velocity field is more disorganized and turbulent. With a spectral resolution of $\sim$1 eV, fast and hot outflows ($\sim$200-500 km s$^{-1}$) can be measured, depending on the orientation of the galaxy on the sky. The rotation velocity of the hot phase ($\sim$100-200 km s$^{-1}$) can be measured using line shifts in edge-on galaxies, and is slower than that of colder gas phases but similar to stellar rotation velocities. By contrast, the slow inflows ($\sim$50-100 km s$^{-1}$) are difficult to measure in projection with these other components, but may be detected in multi-component spectral fits. We find that the velocity measured is sensitive to which emission lines are used. Measuring these flows will constrain theories of how the gas in these galaxies evolves.
△ Less
Submitted 20 May, 2024; v1 submitted 3 July, 2023;
originally announced July 2023.
-
Map** the imprints of stellar and AGN feedback in the circumgalactic medium with X-ray microcalorimeters
Authors:
Gerrit Schellenberger,
Ákos Bogdán,
John A. ZuHone,
Benjamin D. Oppenheimer,
Nhut Truong,
Ildar Khabibullin,
Fred Jennings,
Annalisa Pillepich,
Joseph Burchett,
Christopher Carr,
Priyanka Chakraborty,
Robert Crain,
William Forman,
Christine Jones,
Caroline A. Kilbourne,
Ralph P. Kraft,
Maxim Markevitch,
Daisuke Nagai,
Dylan Nelson,
Anna Ogorzalek,
Scott Randall,
Arnab Sarkar,
Joop Schaye,
Sylvain Veilleux,
Mark Vogelsberger
, et al. (2 additional authors not shown)
Abstract:
The Astro2020 Decadal Survey has identified the map** of the circumgalactic medium (CGM, gaseous plasma around galaxies) as a key objective. We explore the prospects for characterizing the CGM in and around nearby galaxy halos with a future, large grasp X-ray microcalorimeter. We create realistic mock observations from hydrodynamical simulations (EAGLE, IllustrisTNG, and Simba) that demonstrate…
▽ More
The Astro2020 Decadal Survey has identified the map** of the circumgalactic medium (CGM, gaseous plasma around galaxies) as a key objective. We explore the prospects for characterizing the CGM in and around nearby galaxy halos with a future, large grasp X-ray microcalorimeter. We create realistic mock observations from hydrodynamical simulations (EAGLE, IllustrisTNG, and Simba) that demonstrate a wide range of potential measurements, which will address the open questions in galaxy formation and evolution. By including all background and foreground components in our mock observations, we show why it is impossible to perform these measurements with current instruments, such as X-ray CCDs, and only microcalorimeters will allow us to distinguish the faint CGM emission from the bright Milky Way (MW) foreground emission lines. We find that individual halos of MW mass can, on average and depending on star formation rate, be traced out to large radii, around R500, and for larger galaxies even out to R200, using prominent emission lines, such as OVII, or OVIII. Furthermore, we show that emission line ratios for individual halos can reveal the radial temperature structure. Substructure measurements show that it will be possible to relate azimuthal variations to the feedback mode of the galaxy. We demonstrate the ability to construct temperature, velocity, and abundance ratio maps from spectral fitting for individual galaxy halos, which reveal rotation features, AGN outbursts, and enrichment.
△ Less
Submitted 29 April, 2024; v1 submitted 3 July, 2023;
originally announced July 2023.
-
Ground test results of the micro-vibration interference for the x-ray microcalorimeter onboard XRISM
Authors:
Takashi Hasebe,
Ryuta Imamura,
Masahiro Tsujimoto,
Hisamitsu Awaki,
Meng P. Chiao,
Ryuichi Fujimoto,
Leslie S. Hartz,
Caroline A. Kilbourne,
Gary A. Sneiderman,
Yoh Takei,
Susumu Yasuda
Abstract:
Resolve is a payload hosting an X-ray microcalorimeter detector operated at 50 mK in the X-Ray Imaging and Spectroscopy Mission (XRISM). It is currently under development as part of an international collaboration and is planned to be launched in 2023. A primary technical concern is the micro-vibration interference in the sensitive microcalorimeter detector caused by the spacecraft bus components.…
▽ More
Resolve is a payload hosting an X-ray microcalorimeter detector operated at 50 mK in the X-Ray Imaging and Spectroscopy Mission (XRISM). It is currently under development as part of an international collaboration and is planned to be launched in 2023. A primary technical concern is the micro-vibration interference in the sensitive microcalorimeter detector caused by the spacecraft bus components. We conducted a series of verification tests in 2021-2022 on the ground, the results of which are reported here. We defined the micro-vibration interface between the spacecraft and the Resolve instrument. In the instrument-level test, the flight-model hardware was tested against the interface level by injecting it with micro-vibrations and evaluating the instrument response using the 50 mK stage temperature stability, ADR magnet current consumption rate, and detector noise spectra. We found strong responses when injecting micro-vibration at about 200, 380, and 610 Hz. In the former two cases, the beat between the injected frequency and cryocooler frequency harmonics were observed in the detector noise spectra. In the spacecraft-level test, the acceleration and instrument responses were measured with and without suspension of the entire spacecraft. The reaction wheels (RWs) and inertial reference units (IRUs), two major sources of micro-vibration among the bus components, were operated. In conclusion, the observed responses of Resolve are within the acceptable levels in the nominal operational range of the RWs and IRUs. There is no evidence that the resultant energy
resolution degradation is beyond the current allocation of noise budget.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Mechanical cryocooler noise observed in the ground testing of the Resolve X-ray microcalorimeter onboard XRISM
Authors:
R. Imamura,
H. Awaki,
M. Tsujimoto,
S. Yamada,
F. S. Porter,
C. A. Kilbourne,
R. L. Kelley,
Y. Takei
Abstract:
Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these detectors. We have observed this effect in the ground test data obtained with the Resolve instrument to be flown on the XRISM satellite. Resolve is a cryogenic X-ray…
▽ More
Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these detectors. We have observed this effect in the ground test data obtained with the Resolve instrument to be flown on the XRISM satellite. Resolve is a cryogenic X-ray microcalorimeter spectrometer with a required energy resolution of 7 eV at 6 keV. Five mechanical coolers are used to cool from ambient temperature to about 4 K: four two-stage Stirling coolers (STC) driven nominally at 15 Hz and a Joule-Thomson cooler (JTC) driven nominally at 52 Hz. In 2019, we operated the flight-model instrument for two weeks, in which we also obtained accelerometer data inside the cryostat at a low-temperature stage (He tank). X-ray detector and accelerometer data were obtained continuously while changing the JTC drive frequency, which produced a unique data set for investigating how the vibration from the cryocoolers propagates to the detector. In the detector noise spectra, we observed harmonics of both STCs and JTC. More interestingly, we also observed the low (<20 Hz) frequency beat between the 4'th JTC and 14'th STC harmonics and the 7'th JTC and the 23--24'th STC harmonics. We present here a description and interpretation of these measurements.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM
Authors:
Miki Kurihara,
Masahiro Tsujimoto,
Megan E. Eckart,
Caroline A. Kilbourne,
Frederick T. Matsuda,
Brian McLaughlin,
Shugo Oguri,
Frederick S. Porter,
Yoh Takei,
Yoichi Kochibe
Abstract:
Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which is currently under development by an international collaboration and is planned to be launched in 2023. We focus on…
▽ More
Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which is currently under development by an international collaboration and is planned to be launched in 2023. We focus on the EMI from (a) the low-frequency magnetic field generated by the magnetic torquers (MTQ) used for the spacecraft attitude control and (b) the radio-frequency (RF) electromagnetic field generated by the S and X band antennas used for communication between the spacecraft and the ground stations. We executed a series of ground tests both at the instrument and spacecraft levels using the flight-model hardware in 2021-2022 in a JAXA facility in Tsukuba. We also conducted electromagnetic simulations partially using the Fugaku high-performance computing facility. The MTQs were found to couple with the microcalorimeter, which we speculate through pick-ups of low-frequency magnetic field and further capacitive coupling. There is no evidence that the resultant energy resolution degradation is beyond the current allocation of noise budget. The RF communication system was found to leave no significant effect. We present the result of the tests and simulation in this article.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
First Flight Performance of the Micro-X Microcalorimeter X-Ray Sounding Rocket
Authors:
Joseph S. Adams,
Robert Baker,
Simon R. Bandler,
Noemie Bastidon,
Daniel Castro,
Meredith E. Danowksi,
William B. Doriese,
Megan E. Eckart,
Enectali Figueroa-Feliciano,
Joshua Fuhrman,
David C. Goldfinger,
Sarah N. T. Heine,
Gene Hilton,
Antonia J. F. Hubbard,
Daniel Jardin,
Richard L. Kelley,
Caroline A. Kilbourne,
Steven W. Leman,
Renee E. Manzagol-Harwood,
Dan McCammon,
Philip H. H. Oakley,
Takashi Okajima,
Frederick Scott Porter,
Carl D. Reintsema,
John Rutherford
, et al. (6 additional authors not shown)
Abstract:
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on…
▽ More
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on-target, data from the flight was used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared to ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Micro-X Sounding Rocket Payload Re-flight Progress
Authors:
J. S. Adams,
S. R. Bandler,
N. Bastidon,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
S. J. Smith
Abstract:
Micro-X is an X-ray sounding rocket payload that had its first flight on July 22, 2018. The goals of the first flight were to operate a transition edge sensor (TES) X-ray microcalorimeter array in space and take a high-resolution spectrum of the Cassiopeia A supernova remnant. The first flight was considered a partial success. The array and its time-division multiplexing readout system were succes…
▽ More
Micro-X is an X-ray sounding rocket payload that had its first flight on July 22, 2018. The goals of the first flight were to operate a transition edge sensor (TES) X-ray microcalorimeter array in space and take a high-resolution spectrum of the Cassiopeia A supernova remnant. The first flight was considered a partial success. The array and its time-division multiplexing readout system were successfully operated in space, but due to a failure in the attitude control system, no time on-target was acquired. A re-flight has been scheduled for summer 2022. Since the first flight, modifications have been made to the detector systems to improve noise and reduce the susceptibility to magnetic fields. The three-stage SQUID circuit, NIST MUX06a, has been replaced by a two-stage SQUID circuit, NIST MUX18b. The initial laboratory results for the new detector system will be presented in this paper.
△ Less
Submitted 12 November, 2021;
originally announced November 2021.
-
Modeling a Three-Stage SQUID System in Space with the First Micro-X Sounding Rocket Flight
Authors:
J. S. Adams,
S. R. Bandler,
N. Bastidon,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
S. J. Smith
Abstract:
The Micro-X sounding rocket is a NASA funded X-ray telescope payload that completed its first flight on July 22, 2018. This event marked the first operation of Transition Edge Sensors (TESs) and their SQUID-based multiplexing readout system in space. Unfortunately, due to an ACS pointing failure, the rocket was spinning during its five minute observation period and no scientific data was collected…
▽ More
The Micro-X sounding rocket is a NASA funded X-ray telescope payload that completed its first flight on July 22, 2018. This event marked the first operation of Transition Edge Sensors (TESs) and their SQUID-based multiplexing readout system in space. Unfortunately, due to an ACS pointing failure, the rocket was spinning during its five minute observation period and no scientific data was collected. However, data collected from the internal calibration source marked a partial success for the payload and offers a unique opportunity to study the response of TESs and SQUIDs in space. Of particular interest is the magnetic field response of the NIST MUX06a SQUID readout system to tumbling through Earth's magnetic field. We present a model to explain the baseline response of the SQUIDs, which lead to a subset of pixels failing to "lock" for the full observational period. Future flights of the Micro-X rocket will include the NIST MUX18b SQUID system with dramatically reduced magnetic susceptibility.
△ Less
Submitted 11 November, 2021;
originally announced November 2021.
-
High-resolution Laboratory Measurements of K-shell X-ray Line Polarization and Excitation Cross Sections in Heliumlike S XV Ions
Authors:
Chintan Shah,
Natalie Hell,
Antonia Hubbard,
Ming Feng Gu,
Michael J. MacDonald,
Megan E. Eckart,
Richard L. Kelley,
Caroline A. Kilbourne,
Maurice A. Leutenegger,
F. Scott Porter,
Gregory V. Brown
Abstract:
We report measurements of electron-impact excitation cross sections for the strong K-shell n=2-1 transitions in S XV using the LLNL EBIT-I electron beam ion trap, two crystal spectrometers, and the EBIT Calorimeter Spectrometer. The cross sections are determined by direct normalization to the well known cross sections of radiative electron capture, measured simultaneously. Using contemporaneous po…
▽ More
We report measurements of electron-impact excitation cross sections for the strong K-shell n=2-1 transitions in S XV using the LLNL EBIT-I electron beam ion trap, two crystal spectrometers, and the EBIT Calorimeter Spectrometer. The cross sections are determined by direct normalization to the well known cross sections of radiative electron capture, measured simultaneously. Using contemporaneous polarization measurements with the two crystal spectrometers, whose dispersion planes are oriented parallel and perpendicular to the electron beam direction, the polarization of the direct excitation line emission is determined, and in turn the isotropic total cross sections are extracted. We further experimentally investigate various line-formation mechanisms, finding that radiative cascades and collisional inner-shell ionization dominate the degree of linear polarization and total line-emission cross sections of the forbidden line $z$.
△ Less
Submitted 11 June, 2021;
originally announced June 2021.
-
First operation of Transition-Edge Sensors in space with the Micro-X sounding rocket
Authors:
J. S. Adams,
R. Baker,
S. R. Bandler,
N. Bastidon,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-r…
▽ More
With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-rays from the on-board calibration source, but a susceptibility to external magnetic fields limited their livetime. Accounting for this, no change was observed in detector response between ground operation and flight operation. This paper provides an overview of the first flight performance and focuses on the upgrades made in preparation for reflight. The largest changes have been upgrading the SQUIDs to mitigate magnetic susceptibility, synchronizing the clocks on the digital electronics to minimize beat frequencies, and replacing the mounts between the cryostat and the rocket skin to improve mechanical integrity. As the first flight performance was consistent with performance on the ground, reaching the instrument goals in the laboratory is considered a strong predictor of future flight performance.
△ Less
Submitted 3 March, 2021;
originally announced March 2021.
-
Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays
Authors:
M. A. Leutenegger,
M. E. Eckart,
S. J. Moseley,
S. O. Rohrbach,
J. K. Black,
M. P. Chiao,
R. L. Kelley,
C. A. Kilbourne,
F. S. Porter
Abstract:
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the…
▽ More
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the \kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $μ$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $μ$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our \crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.
△ Less
Submitted 13 August, 2020;
originally announced August 2020.
-
A High Spectral Resolution Study of the Soft X-ray Background with the X-ray Quantum Calorimeter
Authors:
Dallas Wulf,
Megan E Eckart,
Massimiliano Galeazzi,
Felix Jaeckel,
Richard L Kelley,
Caroline A Kilbourne,
Kelsey M Morgan,
Dan McCammon,
F Scott Porter,
Andrew E Szymkowiak
Abstract:
We present here a combined analysis of four high spectral resolution observations of the Diffuse X-ray Background (DXRB), made using the University of Wisconsin-Madison/Goddard Space Flight Center X-ray Quantum Calorimeter (XQC) sounding rocket payload. The observed spectra support the existence of a $\sim0.1~$keV Local Hot Bubble and a $\sim0.2~$keV Hot Halo, with discrepancies between repeated o…
▽ More
We present here a combined analysis of four high spectral resolution observations of the Diffuse X-ray Background (DXRB), made using the University of Wisconsin-Madison/Goddard Space Flight Center X-ray Quantum Calorimeter (XQC) sounding rocket payload. The observed spectra support the existence of a $\sim0.1~$keV Local Hot Bubble and a $\sim0.2~$keV Hot Halo, with discrepancies between repeated observations compatible with expected contributions of time-variable emission from Solar Wind Charge Exchange (SWCX). An additional component of $\sim0.9~$keV emission observed only at low galactic latitudes can be consistently explained by unresolved dM stars.
△ Less
Submitted 16 September, 2019;
originally announced September 2019.
-
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Authors:
J. S. Adams,
R. Baker,
S. R. Bandler,
N. Bastidon,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
J. N. Ullom,
P. Wikus
Abstract:
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to…
▽ More
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The on-board calibration source provided X-rays in flight, and it is used to compare detector performance during pre-flight integration, flight, and after the successful post-flight recovery. This calibration data demonstrates the capabilities of the detector in a space environment as well as its potential for future flights.
△ Less
Submitted 5 January, 2020; v1 submitted 26 August, 2019;
originally announced August 2019.
-
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration
Authors:
J. S. Adams,
A. J. Anderson,
R. Baker,
S. R. Bandler,
N. Bastidon,
D. Castro,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for in…
▽ More
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.
△ Less
Submitted 30 January, 2020; v1 submitted 22 August, 2019;
originally announced August 2019.
-
Towards 100,000-pixel microcalorimeter arrays using multi-absorber transition-edge sensors
Authors:
S. J. Smith,
J. S. Adams,
S. R. Bandler,
S. Beaumont,
J. A. Chervenak,
A. M. Datesman,
F. M. Finkbeiner,
R. Hummatov,
R. L. Kelly,
C. A. Kilbourne,
A. R. Miniussi,
F. S. Porter,
J. E. Sadleir,
K. Sakai,
N. A. Wakeham,
E. J. Wassell,
M. C. Witthoeft,
K. Ryu
Abstract:
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associate…
▽ More
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associated with arrays of individual TESs. Hydras are under development for the next generation of space telescope such as Lynx. Lynx is a NASA concept under study that will combine a < 1 arcsecond angular resolution optic with 100,000-pixel microcalorimeter array with energy resolution of deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and 50 micron pitch are studied. Arrays incorporate, for the first time, microstrip buried wiring layers of suitable pitch and density required to readout a full-scale Lynx array. The resolution from the coadded energy histogram including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at an energy of 1.5 keV for the 25 micron and 50 micron absorber designs respectively. Position discrimination is demonstrated from parameterization of the rise-time.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.
-
High-resolution Charge Exchange Spectra with L-shell Nickel Show Striking Differences from Models
Authors:
G. L. Betancourt-Martinez,
P. Beiersdorfer,
G. V. Brown,
R. S. Cumbee,
N. Hell,
R. L. Kelley,
C. A. Kilbourne,
M. A. Leutenegger,
T. E. Lockard,
F. S. Porter
Abstract:
We present the first high-resolution laboratory spectra of X-ray emission following L-shell charge exchange between nickel ions and neutral H2 and He. We employ the commonly used charge exchange models found in XSPEC and SPEX, ACX and SPEX-CX, to simulate our experimental results. We show that significant differences between data and models exist in both line energies and strengths. In particular,…
▽ More
We present the first high-resolution laboratory spectra of X-ray emission following L-shell charge exchange between nickel ions and neutral H2 and He. We employ the commonly used charge exchange models found in XSPEC and SPEX, ACX and SPEX-CX, to simulate our experimental results. We show that significant differences between data and models exist in both line energies and strengths. In particular, we find that configuration mixing may play an important role in generating lines from core-excited states, and may be improperly treated in models. Our results indicate that if applied to astrophysical data, these models may lead to incorrect assumptions of the physical and chemical parameters of the region of interest.
△ Less
Submitted 29 November, 2018;
originally announced November 2018.
-
Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. S…
▽ More
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
Energy scale calibration and drift correction of the X-IFU
Authors:
Edoardo Cucchetti,
Megan E. Eckart,
Philippe Peille,
Cor de Vries,
François Pajot,
Etienne Pointecouteau,
Maurice Leutenegger,
Caroline A. Kilbourne,
Frederick S. Porter
Abstract:
The Athena X-Ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV energy band. It will comprise an array of 3840 superconducting Transition Edge Sensors (TESs) operated at 90 mK, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations i…
▽ More
The Athena X-Ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV energy band. It will comprise an array of 3840 superconducting Transition Edge Sensors (TESs) operated at 90 mK, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in degradation of the detector's energy resolution, and eventually in systematic errors in the absolute energy scale if not properly corrected. These changes will be monitored via an onboard Modulated X-ray Source (MXS) and the energy scale will be corrected accordingly using a multi-parameter interpolation of gain curves obtained during ground calibration. Assuming realistic MXS configurations and using the instrument end-to-end simulator SIXTE, we investigate here both statistical and systematic effects on the X-IFU energy scale, occurring either during ground measurements or in-flight. The corresponding impacts on the energy resolution and means of accounting for these errors are also addressed. We notably demonstrate that a multi-parameter gain correction, using both the pulse-height estimate and the baseline of a pulse, can accurately recover systematic effects on the gain due to realistic changes in TES operating conditions within 0.4 eV. Optimisations of this technique with respect to the MXS line configuration and correction time, as well as to the energy scale parametrization are also show promising results to improve the accuracy of the correction.
△ Less
Submitted 4 July, 2018;
originally announced July 2018.
-
Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution
Authors:
Edoardo Cucchetti,
François Pajot,
Etienne Pointecouteau,
Philippe Peille,
Gabriele Betancourt-Martinez,
Stephen J. Smith,
Marco Barbera,
Megan E. Eckart,
Simon R. Bandler,
Caroline A. Kilbourne,
Massimo Cappi,
Didier Barret
Abstract:
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge…
▽ More
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining and validating calibration requirements is therefore of paramount importance. In this paper, we put forward a simulation tool based on the most up-to-date configurations of the various subsystems (e.g. filters, detector absorbers) which allows us to estimate systematic errors related to uncertainties in the instrumental response. Notably, the effect of uncertainties in the energy resolution and of the instrumental quantum efficiency on X-IFU observations is assessed, by taking as a test case the measurements of the iron K complex in the hot gas surrounding clusters of galaxies. In-flight and ground calibration of the energy resolution and the quantum efficiency is also addressed. We demonstrate that provided an accurate calibration of the instrument, such effects should be low in both cases with respect to statistics during observations.
△ Less
Submitted 4 July, 2018;
originally announced July 2018.
-
Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (173 additional authors not shown)
Abstract:
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with…
▽ More
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
In-flight Calibration of Hitomi Soft X-ray Spectrometer (3) Effective Area
Authors:
Masahiro Tsujimoto,
Takashi Okajima,
Megan E. Eckart,
Takayuki Hayashi,
Akio Hoshino,
Ryo Iizuka,
Richard L. Kelley,
Caroline A. Kilbourne,
Maurice A. Leutenegger,
Yoshitomo Maeda,
Hideyuki Mori,
Frederick S. Porter,
Kosuke Sato,
Toshiki Sato,
Peter J. Serlemitsos,
Andrew Szymkowiak,
Tahir Yaqoob
Abstract:
We present the result of the in-flight calibration of the effective area of the Soft X-ray Spectrometer (SXS) onboard the Hitomi X-ray satellite using an observation of the Crab nebula. We corrected for the artifacts when observing high count rate sources with the X-ray microcalorimeter. We then constructed a spectrum in the 0.5-20 keV band, which we modeled with a single power-law continuum atten…
▽ More
We present the result of the in-flight calibration of the effective area of the Soft X-ray Spectrometer (SXS) onboard the Hitomi X-ray satellite using an observation of the Crab nebula. We corrected for the artifacts when observing high count rate sources with the X-ray microcalorimeter. We then constructed a spectrum in the 0.5-20 keV band, which we modeled with a single power-law continuum attenuated by an interstellar extinction. We evaluated the systematic uncertainty upon the spectral parameters by various calibration items. In the 2-12 keV band, the SXS result is consistent with the literature values in flux (2.20 $\pm$ 0.08) $\times$10$^{-8}$ erg s$^{-1}$ cm$^{-2}$ with a 1$σ$ statistical uncertainty) but is softer in the power-law index (2.19 $\pm$ 0.11). The discrepancy is attributable to the systematic uncertainty of about $+$6/$-$7% and $+$2/$-$5% respectively for the flux and the power-law index. The softer spectrum is affected primarily by the systematic uncertainty of the Dewar gate valve transmission and the event screening.
△ Less
Submitted 6 January, 2018;
originally announced January 2018.
-
Temperature Structure in the Perseus Cluster Core Observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated wi…
▽ More
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.
△ Less
Submitted 18 December, 2017;
originally announced December 2017.
-
Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, a…
▽ More
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that an accurate atomic code is as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current codes ready for the data from the next Hitomi-level mission.
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
Hitomi Observations of the LMC SNR N132D: Highly Redshifted X-ray Emission from Iron Ejecta
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on t…
▽ More
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km/s compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50-1500 km/s if a weakly informative prior is placed on possible line broadening. This indicates (1) that the Fe emission arises from the supernova ejecta, and (2) that these ejecta are highly asymmetric, since no blue-shifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial map** that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.
△ Less
Submitted 6 December, 2017;
originally announced December 2017.
-
Glimpse of the highly obscured HMXB IGR J16318-4848 with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving p…
▽ More
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer; SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and HXI) aboard Hitomi. Even though photon counts are limited due to unintended off-axis pointing, the SXS spectrum resolves Fe K{α_1} and K{α_2} lines and puts strong constraints on the line centroid and width. The line width corresponds to the velocity of 160^{+300}_{-70} km s^{-1}. This represents the most accurate, and smallest, width measurement of this line made so far from any X-ray binary, much less than the Doppler broadening and shift expected from speeds which are characteristic of similar systems. Combined with the K-shell edge energy measured by the SXI and HXI spectra, the ionization state of Fe is estimated to be in the range of Fe I--IV. Considering the estimated ionization parameter and the distance between the X-ray source and the absorber, the density and thickness of the materials are estimated. The extraordinarily strong absorption and the absence of a Compton shoulder component is confirmed. These characteristics suggest reprocessing materials which are distributed in a narrow solid angle or scattering primarily with warm free electrons or neutral hydrogen.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Hitomi Observation of Radio Galaxy NGC 1275: The First X-ray Microcalorimeter Spectroscopy of Fe-Kα Line Emission from an Active Galactic Nucleus
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellit…
▽ More
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275 at the center of the Perseus cluster of galaxies. With the high energy resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the Fe-Kα line with ~5.4 σ significance. The velocity width is constrained to be 500-1600 km s$^{-1}$ (FWHM for Gaussian models) at 90% confidence. The SXS also constrains the continuum level from the NGC 1275 nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line. Because the velocity width is narrower than that of broad Hα line of ~2750 km s$^{-1}$, we can exclude a large contribution to the line flux from the accretion disk and the broad line region. Furthermore, we performed pixel map analyses on the Hitomi/SXS data and image analyses on the Chandra archival data, and revealed that the Fe-Kα line comes from a region within ~1.6 kpc from the NGC 1275 core, where an active galactic nucleus emission dominates, rather than that from intracluster media. Therefore, we suggest that the source of the Fe-Kα line from NGC 1275 is likely a low-covering fraction molecular torus or a rotating molecular disk which probably extends from a pc to hundreds pc scale in the active galactic nucleus system.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Atmospheric gas dynamics in the Perseus cluster observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Rebecca E. A. Canning,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done
, et al. (173 additional authors not shown)
Abstract:
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the…
▽ More
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the hot gas is remarkably low and mostly uniform. The velocity dispersion reaches maxima of approximately 200~km~s$^{-1}$ toward the central active galactic nucleus (AGN) and toward the AGN inflated north-western `ghost' bubble. Elsewhere within the observed region, the velocity dispersion appears constant around 100~km~s$^{-1}$. We also detect a velocity gradient with a 100~km~s$^{-1}$ amplitude across the cluster core, consistent with large-scale sloshing of the core gas. If the observed gas motions are isotropic, the kinetic pressure support is less than 10\% of the thermal pressure support in the cluster core. The well-resolved optically thin emission lines have Gaussian shapes, indicating that the turbulent driving scale is likely below 100~kpc, which is consistent with the size of the AGN jet inflated bubbles. We also report the first measurement of the ion temperature in the intracluster medium, which we find to be consistent with the electron temperature. In addition, we present a new measurement of the redshift to the brightest cluster galaxy NGC~1275.
△ Less
Submitted 1 November, 2017;
originally announced November 2017.
-
Measurements of resonant scattering in the Perseus cluster core with Hitomi SXS
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the ga…
▽ More
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the gas in the core of the Perseus cluster. Here, we show that when inferring physical properties from line emissivities in systems like Perseus, the resonant scattering (RS) effect should be taken into account. In the Hitomi waveband, RS mostly affects the FeXXV He$α$ line ($w$) - the strongest line in the spectrum. The flux measured by Hitomi in this line is suppressed by a factor ~1.3 in the inner ~30 kpc, compared to predictions for an optically thin plasma; the suppression decreases with the distance from the center. The $w$ line also appears slightly broader than other lines from the same ion. The observed distortions of the $w$ line flux, shape and distance dependence are all consistent with the expected effect of the resonant scattering in the Perseus core. By measuring the ratio of fluxes in optically thick ($w$) and thin (FeXXV forbidden, He$β$, Ly$α$) lines, and comparing these ratios with predictions from Monte Carlo radiative transfer simulations, the velocities of gas motions have been obtained. The results are consistent with the direct measurements of gas velocities from line broadening described elsewhere in this series, although the systematic and statistical uncertainties remain significant. Further improvements in the predictions of line emissivities in plasma models, and deeper observations with future X-ray missions will enable RS measurements to provide powerful constraints on the amplitude and anisotropy of clusters gas motions.
△ Less
Submitted 11 October, 2017;
originally announced October 2017.
-
Hitomi X-ray studies of Giant Radio Pulses from the Crab pulsar
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (179 additional authors not shown)
Abstract:
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance…
▽ More
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1,000 and 100 GRPs were simultaneously observed at the main and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main or inter-pulse phases.All variations are within the 2 sigma fluctuations of the X-ray fluxes at the pulse peaks, and the 3 sigma upper limits of variations of main- or inter- pulse GRPs are 22\% or 80\% of the peak flux in a 0.20 phase width, respectively, in the 2 -- 300 keV band.The values become 25\% or 110\% for main or inter-pulse GRPs, respectively, when the phase width is restricted into the 0.03 phase.Among the upper limits from the Hitomi satellite, those in the 4.5-10 keV and the 70-300 keV are obtained for the first time, and those in other bands are consistent with previous reports.Numerically, the upper limits of main- and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) $\times 10^{-11}$ erg cm$^{-2}$, respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere and the number of photon-emitting particles temporally increases.However, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a $>0.02$\% brightening of the pulse-peak flux under such conditions.
△ Less
Submitted 7 August, 2017; v1 submitted 27 July, 2017;
originally announced July 2017.
-
Search for Thermal X-ray Features from the Crab nebula with Hitomi Soft X-ray Spectrometer
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture…
▽ More
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture (EC) explosion with a lower explosion energy by an order of magnitude than Fe-core collapse SNe. In the X-rays, imaging searches were performed for the plasma emission from the shell in the Crab outskirts to set a stringent upper limit to the X-ray emitting mass. However, the extreme brightness of the source hampers access to its vicinity. We thus employed spectroscopic technique using the X-ray micro-calorimeter onboard the Hitomi satellite. By exploiting its superb energy resolution, we set an upper limit for emission or absorption features from yet undetected thermal plasma in the 2-12 keV range. We also re-evaluated the existing Chandra and XMM-Newton data. By assembling these results, a new upper limit was obtained for the X-ray plasma mass of <~ 1Mo for a wide range of assumed shell radius, size, and plasma temperature both in and out of the collisional equilibrium. To compare with the observation, we further performed hydrodynamic simulations of the Crab SNR for two SN models (Fe-core versus EC) under two SN environments (uniform ISM versus progenitor wind). We found that the observed mass limit can be compatible with both SN models if the SN environment has a low density of <~ 0.03 cm-3 (Fe core) or <~ 0.1 cm-3 (EC) for the uniform density, or a progenitor wind density somewhat less than that provided by a mass loss rate of 10-5 Mo yr-1 at 20 km s-1 for the wind environment.
△ Less
Submitted 4 July, 2017; v1 submitted 30 June, 2017;
originally announced July 2017.
-
Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena
Authors:
Hiroki Akamatsu,
Luciano Gottardi,
Jan van der Kuur,
Cor P. de Vries,
Kevin Ravensberg,
Joseph S. Adams,
Simon R. Bandler,
Marcel P. Bruijn,
James A. Chervenak,
Caroline A Kilbourne,
Mikko Kiviranta,
A. J. van den Linden,
Brian D. Jackson,
Stephen J. Smith
Abstract:
We are develo** the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $ΔE$=2.5 eV $@$ 7 keV ($E/ΔE\sim$2800). FDM i…
▽ More
We are develo** the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $ΔE$=2.5 eV $@$ 7 keV ($E/ΔE\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.
△ Less
Submitted 3 November, 2016;
originally announced November 2016.
-
Laboratory Measurements of the K-shell transition energies in L-shell ions of Si and S
Authors:
N. Hell,
G. V. Brown,
J. Wilms,
V. Grinberg,
J. Clementson,
D. Liedahl,
F. S. Porter,
R. L. Kelley,
C. A. Kilbourne,
P. Beiersdorfer
Abstract:
We have measured the energies of the strongest 1s-2ell (ell=s,p) transitions in He- through Ne-like silicon and sulfur ions to an accuracy of better than 1eV using Lawrence Livermore National Laboratory's electron beam ion traps, EBIT-I and SuperEBIT, and the NASA/GSFC EBIT Calorimeter Spectrometer (ECS). We identify and measure the energies of 18 and 21 X-ray features from silicon and sulfur, res…
▽ More
We have measured the energies of the strongest 1s-2ell (ell=s,p) transitions in He- through Ne-like silicon and sulfur ions to an accuracy of better than 1eV using Lawrence Livermore National Laboratory's electron beam ion traps, EBIT-I and SuperEBIT, and the NASA/GSFC EBIT Calorimeter Spectrometer (ECS). We identify and measure the energies of 18 and 21 X-ray features from silicon and sulfur, respectively. The results are compared to new Flexible Atomic Code calculations and to semi-relativistic Hartree Fock calculations by Palmeri et al. (2008). These results will be especially useful for wind diagnostics in high mass X-ray binaries, such as Vela X-1 and Cygnus X-1, where high-resolution spectral measurements using Chandra's high energy transmission grating has made it possible to measure Doppler shifts of 100km/s. The accuracy of our measurements is consistent with that needed to analyze Chandra observations, exceeding Chandra's 100km/s limit. Hence, the results presented here not only provide benchmarks for theory, but also accurate rest energies that can be used to determine the bulk motion of material in astrophysical sources. We show the usefulness of our results by applying them to redetermine Doppler shifts from Chandra observations of Vela X-1.
△ Less
Submitted 1 September, 2016;
originally announced September 2016.
-
Hitomi constraints on the 3.5 keV line in the Perseus galaxy cluster
Authors:
Hitomi Collaboration,
Felix A. Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Keith A. Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger D. Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (193 additional authors not shown)
Abstract:
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-New…
▽ More
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-Newton signal from the large cluster sample under the dark matter decay scenario is too faint to be detectable in the Hitomi data. However, the previously reported 3.5 keV flux from Perseus was anomalously high compared to the sample-based prediction. We find no unidentified line at the reported high flux level. Taking into account the XMM measurement uncertainties for this region, the inconsistency with Hitomi is at a 99% significance for a broad dark-matter line and at 99.7% for a narrow line from the gas. We do not find anomalously high fluxes of the nearby faint K line or the Ar satellite line that were proposed as explanations for the earlier 3.5 keV detections. We do find a hint of a broad excess near the energies of high-n transitions of Sxvi (E=3.44 keV rest-frame) -- a possible signature of charge exchange in the molecular nebula and another proposed explanation for the unidentified line. While its energy is consistent with XMM pn detections, it is unlikely to explain the MOS signal. A confirmation of this interesting feature has to wait for a more sensitive observation with a future calorimeter experiment.
△ Less
Submitted 27 February, 2017; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Searching for keV Sterile Neutrino Dark Matter with X-ray Microcalorimeter Sounding Rockets
Authors:
Enectali Figueroa-Feliciano,
Adam J. Anderson,
Daniel Castro,
David C. Goldfinger,
John Rutherford,
Megan E. Eckart,
Richard L. Kelley,
Caroline A. Kilbourne,
Dan McCammon,
Kelsey Morgan,
Frederick Scott Porter,
Andrew E. Szymkowiak
Abstract:
High-resolution X-ray spectrometers onboard suborbital sounding rockets can search for dark matter candidates that produce X-ray lines, such as decaying keV-scale sterile neutrinos. Even with exposure times and effective areas far smaller than XMM-Newton and Chandra observations, high-resolution, wide field-of-view observations with sounding rockets have competitive sensitivity to decaying sterile…
▽ More
High-resolution X-ray spectrometers onboard suborbital sounding rockets can search for dark matter candidates that produce X-ray lines, such as decaying keV-scale sterile neutrinos. Even with exposure times and effective areas far smaller than XMM-Newton and Chandra observations, high-resolution, wide field-of-view observations with sounding rockets have competitive sensitivity to decaying sterile neutrinos. We analyze a subset of the 2011 observation by the X-ray Quantum Calorimeter instrument centered on Galactic coordinates l = 165, b = -5 with an effective exposure of 106 seconds, obtaining a limit on the sterile neutrino mixing angle of sin^2(2 theta) < 7.2e-10 at 95% CL for a 7 keV neutrino. Better sensitivity at the level of sin^2(2 theta) ~ 2.1e-11 at 95\% CL for a 7 keV neutrino is achievable with future 300-second observations of the galactic center by the Micro-X instrument, providing a definitive test of the sterile neutrino interpretation of the reported 3.56 keV excess from galaxy clusters.
△ Less
Submitted 17 June, 2015;
originally announced June 2015.
-
Accelerator experiments with soft protons and hyper-velocity dust particles: application to ongoing projects of future X-ray missions
Authors:
E. Perinati,
S. Diebold,
E. Kendziorra,
A. Santangelo,
C. Tenzer,
J. Jochum,
S. Bugiel,
R. Srama,
E. Del Monte,
M. Feroci,
A. Rubini,
A. Rachevski,
G. Zampa,
N. Zampa,
I. Rashevskaya,
A. Vacchi,
P. Azzarello,
E. Bozzo,
J. -W. den Herder,
S. Zane,
S. Brandt,
M. Hernanz,
M. A. Leutenegger,
R. L. Kelley,
C. A. Kilbourne
, et al. (9 additional authors not shown)
Abstract:
We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal…
▽ More
We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal in the context of a number of ongoing space projects in order to assess the risk posed by environmental radiation and dust and qualify the adopted instrumentation with respect to possible damage or performance degradation. In this paper we focus on tests for the Silicon Drift Detectors (SDDs) used aboard the LOFT space mission. We use the Van de Graaff accelerators at the University of Tübingen and at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg, for soft proton and hyper-velocity dust tests respectively. We present the experimental set-up adopted to perform the tests, status of the activities and some very preliminary results achieved at present time.
△ Less
Submitted 14 September, 2012;
originally announced September 2012.
-
Observed Limits on Charge Exchange Contributions to the Diffuse X-ray Background
Authors:
S. G. Crowder,
K. A. Barger,
D. E. Brandl,
M. E. Eckart,
M. Galeazzi,
R. L. Kelley,
C. A. Kilbourne,
D. McCammon,
C. G. Pfendner,
F. S. Porter,
L. Rocks,
A. E. Szymkowiak,
I. M. Teplin
Abstract:
We present a high resolution spectrum of the diffuse X-ray background from 0.1 to 1 keV for a ~1 region of the sky centered at l=90, b=+60 using a 36-pixel array of microcalorimeters flown on a sounding rocket. With an energy resolution of 11 eV FWHM below 1 keV, the spectrum's observed line ratios help separate charge exchange contributions originating within the heliosphere from thermal emission…
▽ More
We present a high resolution spectrum of the diffuse X-ray background from 0.1 to 1 keV for a ~1 region of the sky centered at l=90, b=+60 using a 36-pixel array of microcalorimeters flown on a sounding rocket. With an energy resolution of 11 eV FWHM below 1 keV, the spectrum's observed line ratios help separate charge exchange contributions originating within the heliosphere from thermal emission of hot gas in the interstellar medium. The X-ray sensitivity below 1 keV was reduced by about a factor of four from contamination that occurred early in the flight, limiting the significance of the results. The observed centroid of helium-like O VII is 568+2-3 eV at 90% confidence. Since the centroid expected for thermal emission is 568.4 eV while for charge exchange is 564.2 eV, thermal emission appears to dominate for this line complex, consistent with much of the high-latitude O VII emission originating in 2-3 x 10^6 K gas in the Galactic halo. On the other hand, the observed ratio of C VI Ly gamma to Ly alpha is 0.3+-0.2. The expected ratios are 0.04 for thermal emission and 0.24 for charge exchange, indicating that charge exchange must contribute strongly to this line and therefore potentially to the rest of the ROSAT R12 band usually associated with 10^6 K emission from the Local Hot Bubble. The limited statistics of this experiment and systematic uncertainties due to the contamination require only >32% thermal emission for O VII and >20% from charge exchange for C VI at the 90% confidence level. An experimental gold coating on the silicon substrate of the array greatly reduced extraneous signals induced on nearby pixels from cosmic rays passing through the substrate, reducing the triggered event rate by a factor of 15 from a previous flight of the instrument.
△ Less
Submitted 7 September, 2012;
originally announced September 2012.
-
Proximity Effects and Nonequilibrium Superconductivity in Transition-Edge Sensors
Authors:
John E. Sadleir,
Stephen J. Smith,
Ian K. Robinson,
Fred M. Finkbeiner,
James A. Chervenak,
Simon R. Bandler,
Megan E. Eckart,
Caroline A. Kilbourne
Abstract:
We have recently shown that normal-metal/superconductor (N/S) bilayer TESs (superconducting Transition-Edge Sensors) exhibit weak-link behavior.1 Here we extend our understanding to include TESs with added noise-mitigating normal-metal structures (N structures). We find TESs with added Au structures also exhibit weak-link behavior as evidenced by exponential temperature dependence of the critical…
▽ More
We have recently shown that normal-metal/superconductor (N/S) bilayer TESs (superconducting Transition-Edge Sensors) exhibit weak-link behavior.1 Here we extend our understanding to include TESs with added noise-mitigating normal-metal structures (N structures). We find TESs with added Au structures also exhibit weak-link behavior as evidenced by exponential temperature dependence of the critical current and Josephson-like oscillations of the critical current with applied magnetic field. We explain our results in terms of an effect converse to the longitudinal proximity effect (LoPE)1, the lateral inverse proximity effect (LaiPE), for which the order parameter in the N/S bilayer is reduced due to the neighboring N structures. Resistance and critical current measurements are presented as a function of temperature and magnetic field taken on square Mo/Au bilayer TESs with lengths ranging from 8 to 130 μm with and without added N structures. We observe the inverse proximity effect on the bilayer over in-plane distances many tens of microns and find the transition shifts to lower temperatures scale approximately as the inverse square of the in- plane N-structure separation distance, without appreciable broadening of the transition width. We also present evidence for nonequilbrium superconductivity and estimate a quasiparticle lifetime of 1.8 \times 10-10 s for the bilayer. The LoPE model is also used to explain the increased conductivity at temperatures above the bilayer's steep resistive transition.
△ Less
Submitted 23 August, 2011;
originally announced August 2011.
-
A Suzaku Observation of the Low-Ionization Fe-Line Emission from RCW 86
Authors:
Masaru Ueno,
Rie Sato,
Jun Kataoka,
Aya Bamba,
Ilana Harrus,
Junko Hiraga,
John P. Hughes,
Caroline A. Kilbourne,
Katsuji Koyama,
Motohide Kokubun,
Hiroshi Nakajima,
Masanobu Ozaki,
Robert Petre,
Tadayuki Takahashi,
Takaaki Tanaka,
Hiroshi Tomida,
Hiroya Yamaguchi
Abstract:
The newly operational X-ray satellite Suzaku observed the southwestern quadrant of the supernova remnant (SNR) RCW 86 in February 2006 to study the nature of the 6.4 keV emission line first detected with the Advanced Satellite for Cosmology and Astronomy (ASCA). The new data confirm the existence of the line, localizing it for the first time; most of the line emission is adjacent and interior to…
▽ More
The newly operational X-ray satellite Suzaku observed the southwestern quadrant of the supernova remnant (SNR) RCW 86 in February 2006 to study the nature of the 6.4 keV emission line first detected with the Advanced Satellite for Cosmology and Astronomy (ASCA). The new data confirm the existence of the line, localizing it for the first time; most of the line emission is adjacent and interior to the forward shock and not at the locus of the continuum hard emission. We also report the first detection of a 7.1 keV line that we interpret as the K-beta emission from low-ionization iron. The Fe-K line features are consistent with a non-equilibrium plasma of Fe-rich ejecta with n_{e}t <~ 10^9 cm^-3 s and kT_{e} ~ 5 keV. This combination of low n_{e}t and high kT_{e} suggests collisionless electron heating in an SNR shock. The Fe K-alpha line shows evidence for intrinsic broadening, with a width of 47 (34--59) eV (99% error region). The difference of the spatial distributions of the hard continuum above 3 keV and the Fe-K line emission support a synchrotron origin for the hard continuum.
△ Less
Submitted 13 October, 2006;
originally announced October 2006.
-
Suzaku Observations of the Local and Distant Hot ISM
Authors:
Randall K. Smith,
Mark W. Bautz,
Richard J. Edgar,
Kenji Hamaguchi,
John P. Hughes,
Manabu Ishida,
Richard Kelley,
Caroline A. Kilbourne,
K. D. Kuntz,
Dan McCammon,
Eric Miller,
Kazuhisa Mitsuda,
Koji Mukai,
Paul P. Plucinsky,
F. Scott Porter,
Ryuichi Fujimoto,
Steve Snowden,
Yoh Takei,
Yukikatsu Terada,
Yohko Tsuboi,
Noriko Yamasaki
Abstract:
Suzaku observed the molecular cloud MBM12 and a blank field less than 3 degrees away to separate the local and distant components of the diffuse soft X-ray background. Towards MBM12, a local (D< 275 pc) O VII emission line was clearly detected with an intensity of 3.5 ph cm^{-2} s^{-1} sr^{-1}$ (or line units, LU), and the O VIII flux was <0.34 LU. The origin of this O VII emission could be hot…
▽ More
Suzaku observed the molecular cloud MBM12 and a blank field less than 3 degrees away to separate the local and distant components of the diffuse soft X-ray background. Towards MBM12, a local (D< 275 pc) O VII emission line was clearly detected with an intensity of 3.5 ph cm^{-2} s^{-1} sr^{-1}$ (or line units, LU), and the O VIII flux was <0.34 LU. The origin of this O VII emission could be hot gas in the Local Hot Bubble (LHB), charge exchange between oxygen ions in the solar wind (SWCX) and geocoronal or interplanetary material, or a combination of the two. If entirely from the LHB, the implied temperature and emission measure would predict 1/4 keV emission in excess of observations. There is no evidence in the X-ray light curve or solar wind data for a significant contribution from geocoronal SWCX. In any case, the observed O VII flux represents an upper limit to both the LHB emission and interplanetary SWCX in this direction.
The off-cloud observation was performed immediately following the on-cloud. The net off-cloud O VII and O VIII intensities were (respectively) 2.34\pm0.33 and 0.77\pm0.16 LU, after subtracting the on-cloud foreground emission. Assuming the LHB and SWCX components did not change, these increases can be attributed to more distant Galactic disk, halo, or extragalactic emission. If the distant O VII and O VIII emission is from a thermal plasma in collisional equilibrium beyond the Galactic disk, a temperature of (2.1\pm0.1)\times10^6 K with an emission measure of (4\pm0.6)\times10^-3} cm^{-6}pc is inferred.
△ Less
Submitted 29 September, 2006;
originally announced September 2006.
-
Laboratory simulation of cometary x rays using a high-resolution microcalorimeter
Authors:
P. Beiersdorfer,
H. Chen,
K. R. Boyce,
G. V. Brown,
R. L. Kelley,
C. A. Kilbourne,
F. S. Porter,
S. M. Kahn
Abstract:
X-ray emission following charge exchange has been studied on the University of California Lawrence Livermore National Laboratory electron beam ion traps EBIT-I and EBIT-II using a high-resolution microcalorimeter. The measured spectra include the K-shell emission from hydrogenlike and heliumlike C, N, O, and Ne needed for simulations of cometary x-ray emission. A comparison of the spectra produc…
▽ More
X-ray emission following charge exchange has been studied on the University of California Lawrence Livermore National Laboratory electron beam ion traps EBIT-I and EBIT-II using a high-resolution microcalorimeter. The measured spectra include the K-shell emission from hydrogenlike and heliumlike C, N, O, and Ne needed for simulations of cometary x-ray emission. A comparison of the spectra produced in the interaction of O8+ with N2 and CH4 is presented that illustrates the dependence of the observed spectrum on the interaction gas.
△ Less
Submitted 12 June, 2005;
originally announced June 2005.
-
Probing Warm-Hot Intergalactic Medium Associated with the Virgo Cluster using an Oxygen Absorption Line
Authors:
R. Fujimoto,
Y. Takei,
T. Tamura,
K. Mitsuda,
N. Y. Yamasaki,
R. Shibata,
T. Ohashi,
N. Ota,
M. D. Audley,
R. Kelley,
C. A. Kilbourne
Abstract:
To detect a warm-hot intergalactic medium associated with the large-scale structure of the universe, we observed a quasar behind the Virgo cluster with XMM-Newton. With a net exposure time of 54 ks, we marginally detected an OVIII K alpha absorption line at 650.9 +0.8/-1.9 eV in the RGS spectra, with a statistical confidence of 96.4 %. The observed line center energy is consistent with the redsh…
▽ More
To detect a warm-hot intergalactic medium associated with the large-scale structure of the universe, we observed a quasar behind the Virgo cluster with XMM-Newton. With a net exposure time of 54 ks, we marginally detected an OVIII K alpha absorption line at 650.9 +0.8/-1.9 eV in the RGS spectra, with a statistical confidence of 96.4 %. The observed line center energy is consistent with the redshift of M87, and hence the absorber is associated with the Virgo cluster. From the curve of growth, the OVIII column density was estimated to be > 7 x 10^16 cm^-2. In the EPIC spectra, excess emission was found after evaluating the hot intracluster medium in the Virgo cluster and various background components. We inspected the ROSAT All-Sky Survey map of the diffuse soft X-ray background, and confirmed that the level of the north and west regions just outside of the Virgo cluster is consistent with the background model that we used, while that of the east side is significantly higher and the enhancement is comparable with the excess emission found in the EPIC data. We consider a significant portion of the excess emission to be associated with the Virgo cluster, although a possible contribution from the North Polar Spur cannot be excluded. Using the column density and the emission measure and assuming an oxygen abundance of 0.1 and an ionization fraction of 0.4, we estimate that the mean electron density and the line-of-sight distance of the warm-hot gas are < 6 x 10^-5 cm^-3 and > 9 Mpc, respectively. These numbers strongly suggest that we have detected a warm-hot intergalactic medium in a filament associated with the Virgo cluster.
△ Less
Submitted 9 September, 2004; v1 submitted 1 September, 2004;
originally announced September 2004.