-
The QUIJOTE CMB Experiment: status and first results with the multi-frequency instrument
Authors:
M. López-Caniego,
R. Rebolo,
M. Aguiar,
R. Génova-Santos,
F. Gómez-Reñasco,
C. Gutierrez,
J. M. Herreros,
R. J. Hoyland,
C. López-Caraballo,
A. E. Pelaez Santos,
F. Poidevin,
J. A. Rubiño-Martín,
V. Sanchez de la Rosa,
D. Tramonte,
A. Vega-Moreno,
T. Viera-Curbelo,
R. Vignaga,
E. Martínez-González,
R. B. Barreiro,
B. Casaponsa,
F. J. Casas,
J. M. Diego,
R. Fernández-Cobos,
D. Herranz,
D. Ortiz
, et al. (27 additional authors not shown)
Abstract:
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency (10-20 GHz) instrument have been in operation since November 2012. In 2014 a second telescope…
▽ More
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency (10-20 GHz) instrument have been in operation since November 2012. In 2014 a second telescope and a new instrument at 30GHz will be ready for commissioning, and an additional instrument at 40 GHz is in its final design stages. After three years of effective observations, the data obtained by these telescopes and instruments will have the required sensitivity to detect a primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r = 0.05. At the moment, we have completed half of the wide Galactic survey with the multi-frequency instrument covering 18 000 square degrees of the Northern hemisphere. When we finish this survey in early 2014, we shall have reached approximately 14μK per one degree beam at 11, 13, 17 and 19 GHz, in both Q and U.
△ Less
Submitted 5 February, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.
-
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
A. Curto,
F. Cuttaia,
R. J. Davis,
J. Dick,
M. Frailis,
S. Galeotta,
A. Gregorio,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
S. Lowe,
D. Maino,
N. Mandolesi,
M. Maris,
E. Martínez-González,
P. R. Meinhold,
G. Morgante,
D. Pearson,
F. Perrotta,
G. Polenta,
T. Poutanen
, et al. (136 additional authors not shown)
Abstract:
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t…
▽ More
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
△ Less
Submitted 19 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Herschel FIR counterparts of selected Ly-alpha emitters at z~2.2. Fast evolution since z~3 or missed obscured AGNs?
Authors:
A. Bongiovanni,
I. Oteo,
J. Cepa,
A. M. Perez Garcia,
M. Sanchez-Portal,
A. Ederoclite,
J. A. L. Aguerri,
E. J. Alfaro,
B. Altieri,
P. Andreani,
M. T. Aparicio-Villegas,
H. Aussel,
N. Benitez,
S. Berta,
T. Broadhurst,
J. Cabrera-Cano,
F. J. Castander,
A. Cava,
M. Cervino,
H. Chulani,
A. Cimatti,
D. Cristobal-Hornillos,
E. Daddi,
H. Dominguez,
D. Elbaz
, et al. (36 additional authors not shown)
Abstract:
Ly-alpha emitters (LAEs) are seen everywhere in the redshift domain from local to z~7. Far-infrared (FIR) counterparts of LAEs at different epochs could provide direct clues on dust content, extinction, and spectral energy distribution (SED) for these galaxies. We search for FIR counterparts of LAEs that are optically detected in the GOODS-North field at redshift z~2.2 using data from the Herschel…
▽ More
Ly-alpha emitters (LAEs) are seen everywhere in the redshift domain from local to z~7. Far-infrared (FIR) counterparts of LAEs at different epochs could provide direct clues on dust content, extinction, and spectral energy distribution (SED) for these galaxies. We search for FIR counterparts of LAEs that are optically detected in the GOODS-North field at redshift z~2.2 using data from the Herschel Space Telescope with the Photodetector Array Camera and Spectrometer (PACS). The LAE candidates were isolated via color-magnitude diagram using the medium-band photometry from the ALHAMBRA Survey, ancillary data on GOODS-North, and stellar population models. According to the fitting of these spectral synthesis models and FIR/optical diagnostics, most of them seem to be obscured galaxies whose spectra are AGN-dominated. From the analysis of the optical data, we have observed a fraction of AGN or composite over source total number of ~0.75 in the LAE population at z~2.2, which is marginally consistent with the fraction previously observed at z=2.25 and even at low redshift (0.2<z<0.45), but significantly different from the one observed at redshift ~3, which could be compatible either with a scenario of rapid change in the AGN fraction between the epochs involved or with a non detection of obscured AGN in other z=2-3 LAE samples due to lack of deep FIR observations. We found three robust FIR (PACS) counterparts at z~2.2 in GOODS-North. This demonstrates the possibility of finding dust emission in LAEs even at higher redshifts.
△ Less
Submitted 19 August, 2010; v1 submitted 10 August, 2010;
originally announced August 2010.
-
Optimization of Planck/LFI on--board data handling
Authors:
M. Maris,
M. Tomasi,
S. Galeotta,
M. Miccolis,
S. Hildebrandt,
M. Frailis,
R. Rohlfs,
N. Morisset,
A. Zacchei,
M. Bersanelli,
P. Binko,
C. Burigana,
R. C. Butler,
F. Cuttaia,
H. Chulani,
O. D'Arcangelo,
S. Fogliani,
E. Franceschi,
F. Gasparo,
F. Gomez,
A. Gregorio,
J. M. Herreros,
R. Leonardi,
P. Leutenegger,
G. Maggio
, et al. (12 additional authors not shown)
Abstract:
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy…
▽ More
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a function of these parameters. It describes the method of optimizing the onboard processing chain. The tuning procedure is based on a optimization algorithm applied to unprocessed and uncompressed raw data provided either by simulations, prelaunch tests or data taken from LFI operating in diagnostic mode. All the needed optimization steps are performed by an automated tool, OCA2, which ends with optimized parameters and produces a set of statistical indicators, among them the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr = 2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup the process an analytical model is developed that is able to extract most of the relevant information on EpsilonQ and Cr as a function of the signal statistics and the processing parameters. This model will be of interest for the instrument data analysis. The method was applied during ground tests when the instrument was operating in conditions representative of flight. Optimized parameters were obtained and the performance has been verified, the required data rate of 35.5 Kbps has been achieved while kee** EpsilonQ at a level of 3.8% of white noise rms well within the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The Planck/LFI Radiometer Electronics Box Assembly
Authors:
J. M. Herreros,
M. F. Gomez,
R. Rebolo,
H. Chulani,
J. A. Rubino-Martin,
S. R. Hildebrandt,
M. Bersanelli,
R. C. Butler,
M. Miccolis,
A. Pena,
M. Pereira,
F. Torrero,
C. Franceschet,
M. Lopez,
C. Alcala
Abstract:
The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was designed and built incorporating state of the art processors, communication interfaces and real time operating system software in order to meet the scientific performance of the LFI. We present a technical summary of t…
▽ More
The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was designed and built incorporating state of the art processors, communication interfaces and real time operating system software in order to meet the scientific performance of the LFI. We present a technical summary of the REBA, including a physical, functional, electrical, mechanical and thermal description. Aspects of the design and development, the assembly, the integration and the verification of the equipment are provided. A brief description of the LFI on board software is given including the Low-Level Software and the main functionalities and architecture of the Application Software. The compressor module, which has been developed as an independent product, later integrated in the application, is also described in this paper. Two identical engineering models EM and AVM, the engineering qualification model EQM, the flight model FM and flight spare have been manufactured and tested. Low-level and Application software have been developed. Verification activities demonstrated that the REBA hardware and software fulfil all the specifications and perform as required for flight operation.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: the Planck-LFI programme
Authors:
N. Mandolesi,
M. Bersanelli,
R. C. Butler,
E. Artal,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
M. Bartelmann,
K. Bennett,
P. Bhandari,
A. Bonaldi,
J. Borrill,
M. Bremer,
C. Burigana,
R. C. Bowman,
P. Cabella,
C. Cantalupo,
B. Cappellini,
T. Courvoisier,
G. Crone,
F. Cuttaia,
L. Danese,
O. D'Arcangelo,
R. D. Davies
, et al. (118 additional authors not shown)
Abstract:
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic…
▽ More
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
△ Less
Submitted 15 January, 2010;
originally announced January 2010.
-
The Quijote CMB Experiment
Authors:
J. A. Rubino-Martin,
R. Rebolo,
M. Tucci,
R. Genova-Santos,
S. R. Hildebrandt,
R. Hoyland,
J. M. Herreros,
F. Gomez-Renasco,
C. Lopez Caraballo,
E. Martinez-Gonzalez,
P. Vielva,
D. Herranz,
F. J. Casas,
E. Artal,
B. Aja,
L. de la Fuente,
J. L. Cano,
E. Villa,
A. Mediavilla,
J. P. Pascual,
L. Piccirillo,
B. Maffei,
G. Pisano,
R. A. Watson,
R. Davis
, et al. (15 additional authors not shown)
Abstract:
We present the current status of the QUIJOTE (Q-U-I JOint TEnerife) CMB Experiment, a new instrument which will start operations early 2009 at Teide Observatory, with the aim of characterizing the polarization of the CMB and other processes of galactic and extragalactic emission in the frequency range 10-30 GHz and at large angular scales. QUIJOTE will be a valuable complement at low frequencies…
▽ More
We present the current status of the QUIJOTE (Q-U-I JOint TEnerife) CMB Experiment, a new instrument which will start operations early 2009 at Teide Observatory, with the aim of characterizing the polarization of the CMB and other processes of galactic and extragalactic emission in the frequency range 10-30 GHz and at large angular scales. QUIJOTE will be a valuable complement at low frequencies for the PLANCK mission, and will have the required sensitivity to detect a primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r=0.05.
△ Less
Submitted 17 October, 2008;
originally announced October 2008.
-
The CODEX-ESPRESSO experiment: cosmic dynamics, fundamental physics, planets and much more..
Authors:
S. Cristiani,
G. Avila,
P. Bonifacio,
F. Bouchy,
B. Carswell,
S. D'Odorico,
V. D'Odorico,
B. Delabre,
H. Dekker,
M. Dessauges,
P. Dimarcantonio,
R. Garcia-Lopez,
A. Grazian,
M. Haehnelt,
J. M. Herreros,
G. Israelian,
S. Levshakov,
J. Liske,
C. Lovis,
A. Manescau,
E. Martin,
M. Mayor,
D. Megevand,
P. Molaro,
M. Murphy
, et al. (14 additional authors not shown)
Abstract:
CODEX, a high resolution, super-stable spectrograph to be fed by the E-ELT, the most powerful telescope ever conceived, will for the first time provide the possibility of directly measuring the change of the expansion rate of the Universe with time and much more, from the variability of fundamental constants to the search for other earths. A study for the implementation at the VLT of a precursor…
▽ More
CODEX, a high resolution, super-stable spectrograph to be fed by the E-ELT, the most powerful telescope ever conceived, will for the first time provide the possibility of directly measuring the change of the expansion rate of the Universe with time and much more, from the variability of fundamental constants to the search for other earths. A study for the implementation at the VLT of a precursor of CODEX, dubbed ESPRESSO, is presently carried out by a collaboration including ESO, IAC, INAF, IoA Cambridge and Observatoire de Geneve. The present talk is focused on the cosmological aspects of the experiment.
△ Less
Submitted 26 December, 2007;
originally announced December 2007.