The Black Hole Explorer: Back End Electronics
Authors:
Ranjani Srinivasan,
Jonathan Weintroub,
Rick Raffanti,
Bryan Bilyeu,
Thomas Gauron,
John Test,
Elliot Richards,
Manuel Fernandez,
Mark Freeman,
Peter Cheimets,
Mauricio Gendelman,
Kari Haworth,
Janice Houston,
Michael D. Johnson,
Emilia Mamani,
Daniel Marrone,
Ariel L. Pola,
Jade Wang
Abstract:
This paper describes specification and early design of back end signal processing subsystems for the Black Hole Explorer (BHEX) Very Long Baseline Interferometry (VLBI) space telescope. The "back end" consists of two subsystems. First, the block downconverter (BDC) is a heterodyne system that performs a frequency translation of the analog signal from IF to baseband and amplifies and filters it for…
▽ More
This paper describes specification and early design of back end signal processing subsystems for the Black Hole Explorer (BHEX) Very Long Baseline Interferometry (VLBI) space telescope. The "back end" consists of two subsystems. First, the block downconverter (BDC) is a heterodyne system that performs a frequency translation of the analog signal from IF to baseband and amplifies and filters it for digitization. Second, the digital back end (DBE) samples the analog signal with an analog-to-digital converters (ADC) and digitally processes the data stream formatting them to the VLBI "VDIF" standard and converting to Ethernet packets for 100 gigabit-per-second (Gb/s) Ethernet transport to the optical downlink system. Both the BDC and the DBE for BHEX support eight channels of 4.096 GHz bandwidth each, for a total processed bandwidth of 32.768 GHz. The BHEX back end benefits from mature terrestrial back end heritage, described in some detail. The BHEX back end itself is in the early stages of design, with requirements, interface specifications, and component trade studies well advanced. The aim is to build a prototype using terrestrial grade parts which are available in functionally identical space grade equivalents, and to use this prototype to advance the back end Technology Readiness Level (TRL) preparing for a Small Explorer (SMEX) proposal in 2025.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Binospec: A Wide-field Imaging Spectrograph for the MMT
Authors:
Daniel Fabricant,
Robert Fata,
Harland Epps,
Thomas Gauron,
Mark Mueller,
Joseph Zajac,
Stephen Amato,
Jack Barberis,
Henry Bergner,
Patricia Brennan,
Warren Brown,
Igor Chilingarian,
John Geary,
Vladimir Kradinov,
Brian McLeod,
Matthew Smith,
Deborah Woods
Abstract:
Binospec is a high throughput, 370 to 1000 nm, imaging spectrograph that addresses two adjacent 8' by 15' fields of view. Binospec was commissioned in late 2017 at the f/5 focus of the 6.5m MMT and is now available to all MMT observers. Aperture masks cut from stainless steel with a laser cutter are used to define the entrance apertures that range from 15' long slits to hundreds of 2" slitlets. Sy…
▽ More
Binospec is a high throughput, 370 to 1000 nm, imaging spectrograph that addresses two adjacent 8' by 15' fields of view. Binospec was commissioned in late 2017 at the f/5 focus of the 6.5m MMT and is now available to all MMT observers. Aperture masks cut from stainless steel with a laser cutter are used to define the entrance apertures that range from 15' long slits to hundreds of 2" slitlets. System throughputs, including the MMT's mirrors and the f/5 wide-field corrector peak at ~30%. Three reflection gratings, duplicated for the two beams, provide resolutions ($λ$/$Δλ$) between 1300 and $>$5000 with a 1" wide slit. Two through-the-mask guiders are used for target acquisition, mask alignment, guiding, and precision offsets. A full-time Shack-Hartmann wave front sensor allows continuous adjustment of primary mirror support forces, telescope collimation and focus. Active flexure control maintains spectrograph alignment and focus under varying gravity and thermal conditions.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
Wide Field Hard X-ray Survey Telescope: ProtoEXIST1
Authors:
J. Hong,
J. E. Grindlay,
N. Chammas,
B. Allen,
A. Copete,
B. Said,
M. Burke,
J. Howell,
T. Gauron,
R. G. Baker,
S. D. Barthelmy,
S. Sheikh,
N. Gehrels,
W. R. Cook,
J. A. Burnham,
F. A. Harrison,
J. Collins,
S. Labov,
A. Garson III,
H. Krawczynski
Abstract:
We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope (EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1 consists of…
▽ More
We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope (EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1 consists of four independent coded-aperture telescopes with close-tiled (~0.4 mm gaps) CZT detectors that preserve their 2.5mm pixel pitch. Multiple shielding/field-of-view configurations are planned to identify optimal geometry for the HET in EXIST. The primary technical challenge in ProtoEXIST is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm2 for ProtoEXIST1), with all readout and control systems for the ASIC readout vertically stacked. We describe the overall telescope configuration of ProtoEXIST1 and review the current development status of the CZT detectors, from individual detector crystal units (DCUs) to a full detector module (DM). We have built the first units of each component for the detector plane and have completed a few Rev2 DCUs (2x2 cm2), which are under a series of tests. Bare DCUs (pre-crystal bonding) show high, uniform ASIC yield (~70%) and ~30% reduction in electronics noise compared to the Rev1 equivalent. A Rev1 DCU already achieved ~1.2% FWHM at 662 keV, and preliminary analysis of the initial radiation tests on a Rev2 DCU shows ~ 4 keV FWHM at 60 keV (vs. 4.7 keV for Rev1). We therefore expect about <~1% FWHM at 662 keV with the Rev2 detectors.
△ Less
Submitted 17 September, 2007;
originally announced September 2007.
-
Hectospec, the MMT's 300 Optical Fiber-Fed Spectrograph
Authors:
Daniel Fabricant,
Robert Fata,
John Roll,
Edward Hertz,
Nelson Caldwell,
Thomas Gauron,
John Geary,
Brian McLeod,
Andrew Szentgyorgyi
Abstract:
The Hectospec is a 300 optical fiber fed spectrograph commissioned at the MMT in the spring of 2004. A pair of high-speed six-axis robots move the 300 fiber buttons between observing configurations within ~300 s and to an accuracy ~25 microns. The optical fibers run for 26 m between the MMT's focal surface and the bench spectrograph operating at R~1000-2000. Another high dispersion bench spectro…
▽ More
The Hectospec is a 300 optical fiber fed spectrograph commissioned at the MMT in the spring of 2004. A pair of high-speed six-axis robots move the 300 fiber buttons between observing configurations within ~300 s and to an accuracy ~25 microns. The optical fibers run for 26 m between the MMT's focal surface and the bench spectrograph operating at R~1000-2000. Another high dispersion bench spectrograph offering R~5,000, Hectochelle, is also available. The system throughput, including all losses in the telescope optics, fibers, and spectrograph peaks at ~10% at the grating blaze in 1" FWHM seeing. Correcting for aperture losses at the 1.5" diameter fiber entrance aperture, the system throughput peaks at $\sim$17%. Hectospec has proven to be a workhorse instrument at the MMT. Hectospec and Hectochelle together were scheduled for 1/3 of the available nights since its commissioning. Hectospec has returned \~60,000 reduced spectra for 16 scientific programs during its first year of operation.
△ Less
Submitted 25 August, 2005;
originally announced August 2005.