-
Spectroscopic Performance of Detectors for Athena's WFI: Measurements and Simulation
Authors:
Johannes Müller-Seidlitz,
Robert Andritschke,
Valentin Emberger,
Michael Bonholzer,
Günter Hauser,
Peter Lechner,
Astrid Mayr,
Jonas Reiffers,
Anna Schweingruber,
Wolfgang Treberspurg
Abstract:
The depleted p-channel field effect transistor is the chosen sensor type for the Wide Field Imager of the Athena mission. It will be used in two types of cameras. One will enable observations of a field of view of 40' x 40' by using an array of four 512 x 512 pixel sensors in a 2 x 2 configuration. A second, small one is designed to investigate bright, point-like sources with a time resolution of…
▽ More
The depleted p-channel field effect transistor is the chosen sensor type for the Wide Field Imager of the Athena mission. It will be used in two types of cameras. One will enable observations of a field of view of 40' x 40' by using an array of four 512 x 512 pixel sensors in a 2 x 2 configuration. A second, small one is designed to investigate bright, point-like sources with a time resolution of up to 40 microseconds. Sensors of final size, layout, and technology were fabricated, assembled and characterised. Also, first results from the flight production are available and confirm the excellent performance. In order to be able to estimate the future performance of degraded detectors, a simulation was developed that takes into account the non-analytical threshold effects on the basis of measurement results. We present the measurement analysis and the comparison of simulated and measured values as well as first attempts to use the Monte Carlo simulation to predict performance results based on noise measurements.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
Low temperature proton irradiation with DEPFETs for Athena's Wide Field Imager
Authors:
Valentin Emberger,
Robert Andritschke,
Parviz Azhdarzadeh,
Günter Hauser,
Astrid Mayr,
Johannes Müller-Seidlitz,
Abbas Rezaei,
Wolfgang Treberer-Treberspurg
Abstract:
The Wide Field Imager (WFI), one of two instruments on ESA's next large X-ray mission Athena, is designed for imaging spectroscopy of X-rays in the range of 0.2 to 15 keV with a large field of view and high count rate capability. The focal plane consists of back-illuminated DEPFET (Depleted p-channel field effect transistor) sensors that have a high radiation tolerance and provide a near Fano-limi…
▽ More
The Wide Field Imager (WFI), one of two instruments on ESA's next large X-ray mission Athena, is designed for imaging spectroscopy of X-rays in the range of 0.2 to 15 keV with a large field of view and high count rate capability. The focal plane consists of back-illuminated DEPFET (Depleted p-channel field effect transistor) sensors that have a high radiation tolerance and provide a near Fano-limited energy resolution. To achieve this, a very low noise readout is required, about 3 electrons ENC at beginning of life is foreseen. This makes the device very susceptible to any radiation induced worsening of the readout noise. The main mechanism of degradation will be the increase of dark current due to displacement damage caused primarily by high energy protons. To study the expected performance degradation, a prototype detector module with fully representative pixel layout and fabrication technology was irradiated with 62.4 MeV protons at the accelerator facility MedAustron in Wiener Neustadt. A total dose equivalent to 3.3 $\textstyle{10^{9}}$ 10-MeV protons/$\mathrm{cm^{2}}$ was applied in two steps. During, in-between and after the irradiations the detector remained at the operating temperature of 213 K and was fully biased and operated. Data was recorded to analyze the signal of all incident particles. We report on the increase of dark current after the irradiation and present the current related damage rate at 213 K. The effect of low temperature annealing at 213 K , 236 K, 253 K, 273 K, and 289 K is presented.
△ Less
Submitted 2 July, 2024; v1 submitted 28 June, 2024;
originally announced June 2024.
-
Spectroscopic performance of flight-like DEPFET sensors for Athena's WFI
Authors:
Johannes Müller-Seidlitz,
Robert Andritschke,
Michael Bonholzer,
Valentin Emberger,
Günter Hauser,
Maximilian Herrmann,
Peter Lechner,
Astrid Mayr,
Julian Oser
Abstract:
The Wide Field Imager for the Athena X-ray telescope is composed of two back side illuminated detectors using DEPFET sensors operated in rolling shutter readout mode: A large detector array featuring four sensors with 512x512 pixels each and a small detector that facilitates the high count rate capability of the WFI for the investigation of bright, point-like sources. Both sensors were fabricated…
▽ More
The Wide Field Imager for the Athena X-ray telescope is composed of two back side illuminated detectors using DEPFET sensors operated in rolling shutter readout mode: A large detector array featuring four sensors with 512x512 pixels each and a small detector that facilitates the high count rate capability of the WFI for the investigation of bright, point-like sources. Both sensors were fabricated in full size featuring the pixel layout, fabrication technology and readout mode chosen in a preceding prototy** phase. We present the spectroscopic performance of these flight-like detectors for different photon energies in the relevant part of the targeted energy range from 0.2 keV to 15 keV with respect to the timing requirements of the instrument. For 5.9 keV photons generated by an iron-55 source the spectral performance expressed as Full Width at Half Maximum of the emission peak in the spectrum is 126.0 eV for the Large Detector and 129.1 eV for the Fast Detector. A preliminary analysis of the camera's signal chain also allows for a first prediction of the performance in space at the end of the nominal operation phase.
△ Less
Submitted 8 August, 2022;
originally announced August 2022.
-
Total ionizing dose test with DEPFET sensors for Athena's WFI
Authors:
Valentin Emberger,
Michael Bonholzer,
Johannes Müller-Seidlitz,
Robert Andritschke
Abstract:
The focal plane of Athena's WFI consists of spectroscopic single photon X-ray detectors that contain arrays of DEPFETs (DEpleted P-channel Field-Effect Transistor) as well as ASICs that are used for steering, readout and analog signal sha**. These components have to be examined regarding the effect of ionizing radiation. A Total Ionizing Dose (TID) test was done with prototype detector modules w…
▽ More
The focal plane of Athena's WFI consists of spectroscopic single photon X-ray detectors that contain arrays of DEPFETs (DEpleted P-channel Field-Effect Transistor) as well as ASICs that are used for steering, readout and analog signal sha**. These components have to be examined regarding the effect of ionizing radiation. A Total Ionizing Dose (TID) test was done with prototype detector modules with 64x64 DEPFETs and one SWITCHER and VERITAS ASIC each. The current design of the WFI detector head features a proton shield equivalent to 4 cm of aluminum in order to prevent a strong increase of leakage current in the fully depleted 450 $μ$m thick bulk of the sensor. This keeps the expected doses and dose rates during the nominal mission relatively low ($\sim$5 Gy). It is nevertheless important to study the current system in a dedicated TID test in order to exclude unforeseen effects and to study any radiation related changes that can have an effect on the very sensitive readout chain and the detector performance. The combination of low doses, low dose rates, low operating temperature (<-60°C) but high sensitivity on small changes of the threshold voltages represent somehow unusual boundary conditions in comparison to TID tests for standard radiation hard electronic components. Under these circumstances it was found beneficial to do the test in our own laboratory with an X-ray source in order to realize irradiation during nominal operation conditions. Furthermore, it facilitated to take annealing effects into account. Reasonably accurate dosimetry is achieved by measuring the X-ray spectrum and intensity with the device under test. After irradiation to a total dose of 14 Gy and subsequent annealing the threshold voltage of the DEPFETs were shifted by a mean value of 80 mV, the performance remained unchanged apart from a slight increase in readout noise by 10%.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
The eROSITA X-ray telescope on SRG
Authors:
P. Predehl,
R. Andritschke,
V. Arefiev,
V. Babyshkin,
O. Batanov,
W. Becker,
H. Böhringer,
A. Bogomolov,
T. Boller,
K. Borm,
W. Bornemann,
H. Bräuninger,
M. Brüggen,
H. Brunner,
M. Brusa,
E. Bulbul,
M. Buntov,
V. Burwitz,
W. Burkert,
N. Clerc,
E. Churazov,
D. Coutinho,
T. Dauser,
K. Dennerl,
V. Doroshenko
, et al. (68 additional authors not shown)
Abstract:
eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the primary instrument on the Spectrum-Roentgen-Gamma (SRG) mission, which was successfully launched on July 13, 2019, from the Baikonour cosmodrome. After the commissioning of the instrument and a subsequent calibration and performance verification phase, eROSITA started a survey of the entire sky on December 13, 2019. By the e…
▽ More
eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the primary instrument on the Spectrum-Roentgen-Gamma (SRG) mission, which was successfully launched on July 13, 2019, from the Baikonour cosmodrome. After the commissioning of the instrument and a subsequent calibration and performance verification phase, eROSITA started a survey of the entire sky on December 13, 2019. By the end of 2023, eight complete scans of the celestial sphere will have been performed, each lasting six months. At the end of this program, the eROSITA all-sky survey in the soft X-ray band (0.2--2.3\,keV) will be about 25 times more sensitive than the ROSAT All-Sky Survey, while in the hard band (2.3--8\,keV) it will provide the first ever true imaging survey of the sky. The eROSITA design driving science is the detection of large samples of galaxy clusters up to redshifts $z>1$ in order to study the large-scale structure of the universe and test cosmological models including Dark Energy. In addition, eROSITA is expected to yield a sample of a few million AGNs, including obscured objects, revolutionizing our view of the evolution of supermassive black holes. The survey will also provide new insights into a wide range of astrophysical phenomena, including X-ray binaries, active stars, and diffuse emission within the Galaxy. Results from early observations, some of which are presented here, confirm that the performance of the instrument is able to fulfil its scientific promise. With this paper, we aim to give a concise description of the instrument, its performance as measured on ground, its operation in space, and also the first results from in-orbit measurements.
△ Less
Submitted 7 October, 2020;
originally announced October 2020.