-
Euclid. IV. The NISP Calibration Unit
Authors:
Euclid Collaboration,
F. Hormuth,
K. Jahnke,
M. Schirmer,
C. G. -Y. Lee,
T. Scott,
R. Barbier,
S. Ferriol,
W. Gillard,
F. Grupp,
R. Holmes,
W. Holmes,
B. Kubik,
J. Macias-Perez,
M. Laurent,
J. Marpaud,
M. Marton,
E. Medinaceli,
G. Morgante,
R. Toledo-Moreo,
M. Trifoglio,
Hans-Walter Rix,
A. Secroun,
M. Seiffert,
P. Stassi
, et al. (310 additional authors not shown)
Abstract:
The near-infrared calibration unit (NI-CU) onboard Euclid's Near-Infrared Spectrometer and Photometer (NISP) is the first astronomical calibration lamp based on light-emitting diodes (LEDs) to be operated in space. Euclid is a mission in ESA's 'Cosmic Vision 2015-2025' framework, to explore the dark universe and provide a next-level characterisation of the nature of gravitation, dark matter, and d…
▽ More
The near-infrared calibration unit (NI-CU) onboard Euclid's Near-Infrared Spectrometer and Photometer (NISP) is the first astronomical calibration lamp based on light-emitting diodes (LEDs) to be operated in space. Euclid is a mission in ESA's 'Cosmic Vision 2015-2025' framework, to explore the dark universe and provide a next-level characterisation of the nature of gravitation, dark matter, and dark energy. Calibrating photometric and spectrometric measurements of galaxies to better than 1.5% accuracy in a survey homogeneously map** ~14000 deg^2 of extragalactic sky requires a very detailed characterisation of near-infrared (NIR) detector properties, as well their constant monitoring in flight. To cover two of the main contributions - relative pixel-to-pixel sensitivity and non-linearity characteristics - as well as support other calibration activities, NI-CU was designed to provide spatially approximately homogeneous (<12% variations) and temporally stable illumination (0.1%-0.2% over 1200s) over the NISP detector plane, with minimal power consumption and energy dissipation. NI-CU is covers the spectral range ~[900,1900] nm - at cryo-operating temperature - at 5 fixed independent wavelengths to capture wavelength-dependent behaviour of the detectors, with fluence over a dynamic range of >=100 from ~15 ph s^-1 pixel^-1 to >1500 ph s^-1 pixel^-1. For this functionality, NI-CU is based on LEDs. We describe the rationale behind the decision and design process, describe the challenges in sourcing the right LEDs, as well as the qualification process and lessons learned. We also provide a description of the completed NI-CU, its capabilities and performance as well as its limits. NI-CU has been integrated into NISP and the Euclid satellite, and since Euclid's launch in July 2023 has started supporting survey operations.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Euclid. III. The NISP Instrument
Authors:
Euclid Collaboration,
K. Jahnke,
W. Gillard,
M. Schirmer,
A. Ealet,
T. Maciaszek,
E. Prieto,
R. Barbier,
C. Bonoli,
L. Corcione,
S. Dusini,
F. Grupp,
F. Hormuth,
S. Ligori,
L. Martin,
G. Morgante,
C. Padilla,
R. Toledo-Moreo,
M. Trifoglio,
L. Valenziano,
R. Bender,
F. J. Castander,
B. Garilli,
P. B. Lilje,
H. -W. Rix
, et al. (412 additional authors not shown)
Abstract:
The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the proc…
▽ More
The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated, and its technical potentials and limitations. Links to articles providing more details and technical background are included. NISP's 16 HAWAII-2RG (H2RG) detectors with a plate scale of 0.3" pix^-1 deliver a field-of-view of 0.57deg^2. In photo mode, NISP reaches a limiting magnitude of ~24.5AB mag in three photometric exposures of about 100s exposure time, for point sources and with a signal-to-noise ratio (SNR) of 5. For spectroscopy, NISP's point-source sensitivity is a SNR = 3.5 detection of an emission line with flux ~2x10^-16erg/s/cm^2 integrated over two resolution elements of 13.4A, in 3x560s grism exposures at 1.6 mu (redshifted Ha). Our calibration includes on-ground and in-flight characterisation and monitoring of detector baseline, dark current, non-linearity, and sensitivity, to guarantee a relative photometric accuracy of better than 1.5%, and relative spectrophotometry to better than 0.7%. The wavelength calibration must be better than 5A. NISP is the state-of-the-art instrument in the NIR for all science beyond small areas available from HST and JWST - and an enormous advance due to its combination of field size and high throughput of telescope and instrument. During Euclid's 6-year survey covering 14000 deg^2 of extragalactic sky, NISP will be the backbone for determining distances of more than a billion galaxies. Its NIR data will become a rich reference imaging and spectroscopy data set for the coming decades.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Euclid. I. Overview of the Euclid mission
Authors:
Euclid Collaboration,
Y. Mellier,
Abdurro'uf,
J. A. Acevedo Barroso,
A. Achúcarro,
J. Adamek,
R. Adam,
G. E. Addison,
N. Aghanim,
M. Aguena,
V. Ajani,
Y. Akrami,
A. Al-Bahlawan,
A. Alavi,
I. S. Albuquerque,
G. Alestas,
G. Alguero,
A. Allaoui,
S. W. Allen,
V. Allevato,
A. V. Alonso-Tetilla,
B. Altieri,
A. Alvarez-Candal,
A. Amara,
L. Amendola
, et al. (1086 additional authors not shown)
Abstract:
The current standard model of cosmology successfully describes a variety of measurements, but the nature of its main ingredients, dark matter and dark energy, remains unknown. Euclid is a medium-class mission in the Cosmic Vision 2015-2025 programme of the European Space Agency (ESA) that will provide high-resolution optical imaging, as well as near-infrared imaging and spectroscopy, over about 14…
▽ More
The current standard model of cosmology successfully describes a variety of measurements, but the nature of its main ingredients, dark matter and dark energy, remains unknown. Euclid is a medium-class mission in the Cosmic Vision 2015-2025 programme of the European Space Agency (ESA) that will provide high-resolution optical imaging, as well as near-infrared imaging and spectroscopy, over about 14,000 deg^2 of extragalactic sky. In addition to accurate weak lensing and clustering measurements that probe structure formation over half of the age of the Universe, its primary probes for cosmology, these exquisite data will enable a wide range of science. This paper provides a high-level overview of the mission, summarising the survey characteristics, the various data-processing steps, and data products. We also highlight the main science objectives and expected performance.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Euclid's Near-Infrared Spectrometer and Photometer ready for flight -- review of final performance
Authors:
E. Medinaceli,
L. Valenziano,
N. Auricchio,
E. Franceschi,
F. Gianotti,
P. Battaglia,
R. Farinelli,
A. Balestra,
S. Dusini,
C. Sirignano,
E. Borsato,
L. Stanco,
A. Renzi,
A. Troja,
L. Gabarra,
S. Ligori,
V. Capobianco,
L. Corcione,
D. Bonino,
G. Sirri,
L. Patrizii,
M. Tenti,
D. Di Ferdinando,
C. Valieri,
N. Mauri
, et al. (22 additional authors not shown)
Abstract:
ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the surve…
▽ More
ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the survey strategy, we focus our attention on the NISP Data Processing Unit's Application Software, highlighting the experimental process to obtain the final parametrization of the on-board processing of data produced by the array of 16 Teledyne HAWAII-2RG (HgCdTe) detectors. We report results from the latest ground test campaigns with the flight configuration hardware - complete optical system (Korsh anastigmat telescope), detectors array (0.56 deg$^2$ field of view), and readout systems (16 Digital Control Units and Sidecar ASICs). The performance of the on-board processing is then presented. We also describe a major issue found during the final test phase. We show how the problem was identified and solved thanks to an intensive coordinated effort of an independent review `Tiger' team, lead by ESA, and a team of NISP experts from the Euclid Consortium. An extended PLM level campaign at ambient temperature in Liège and a dedicated test campaign conducted in Marseille on the NISP EQM model eventually confirmed the resolution of the problem. Finally, we report examples of the outstanding spectrometric (using a Blue and two Red Grisms) and photometric performance of the NISP instrument, as derived from the end-to-end payload module test campaign at FOCAL 5 -- CSL; these results include the photometric Point Spread Function (PSF) determination and the spectroscopic dispersion verification.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Euclid Near Infrared Spectrometer and Photometer instrument flight model presentation, performance and ground calibration results summary
Authors:
T. Maciaszek,
A. Ealet,
W. Gillard,
K. Jahnke,
R. Barbier,
E. Prieto,
W. Bon,
A. Bonnefoi,
A. Caillat,
M. Carle,
A. Costille,
F. Ducret,
C. Fabron,
B. Foulon,
J. L. Gimenez,
E. Grassi,
M. Jaquet,
D. Le Mignant,
L. Martin,
T. Pamplona,
P. Sanchez,
J. C. Clémens,
L. Caillat,
M. Niclas,
A. Secroun
, et al. (73 additional authors not shown)
Abstract:
The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal…
▽ More
The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal control system, a detection system based on a mosaic of 16 H2RG with their front-end readout electronic, and a warm electronic system (290 K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data.
This paper presents: the final architecture of the flight model instrument and subsystems, and the performance and the ground calibration measurement done at NISP level and at Euclid Payload Module level at operational cold temperature.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Euclid preparation: VII. Forecast validation for Euclid cosmological probes
Authors:
Euclid Collaboration,
A. Blanchard,
S. Camera,
C. Carbone,
V. F. Cardone,
S. Casas,
S. Clesse,
S. Ilić,
M. Kilbinger,
T. Kitching,
M. Kunz,
F. Lacasa,
E. Linder,
E. Majerotto,
K. Markovič,
M. Martinelli,
V. Pettorino,
A. Pourtsidou,
Z. Sakr,
A. G. Sánchez,
D. Sapone,
I. Tutusaus,
S. Yahia-Cherif,
V. Yankelevich,
S. Andreon
, et al. (129 additional authors not shown)
Abstract:
The Euclid space telescope will measure the shapes and redshifts of galaxies to reconstruct the expansion history of the Universe and the growth of cosmic structures. Estimation of the expected performance of the experiment, in terms of predicted constraints on cosmological parameters, has so far relied on different methodologies and numerical implementations, developed for different observational…
▽ More
The Euclid space telescope will measure the shapes and redshifts of galaxies to reconstruct the expansion history of the Universe and the growth of cosmic structures. Estimation of the expected performance of the experiment, in terms of predicted constraints on cosmological parameters, has so far relied on different methodologies and numerical implementations, developed for different observational probes and for their combination. In this paper we present validated forecasts, that combine both theoretical and observational expertise for different cosmological probes. This is presented to provide the community with reliable numerical codes and methods for Euclid cosmological forecasts. We describe in detail the methodology adopted for Fisher matrix forecasts, applied to galaxy clustering, weak lensing and their combination. We estimate the required accuracy for Euclid forecasts and outline a methodology for their development. We then compare and improve different numerical implementations, reaching uncertainties on the errors of cosmological parameters that are less than the required precision in all cases. Furthermore, we provide details on the validated implementations that can be used by the reader to validate their own codes if required. We present new cosmological forecasts for Euclid. We find that results depend on the specific cosmological model and remaining freedom in each setup, i.e. flat or non-flat spatial cosmologies, or different cuts at nonlinear scales. The validated numerical implementations can now be reliably used for any setup. We present results for an optimistic and a pessimistic choice of such settings. We demonstrate that the impact of cross-correlations is particularly relevant for models beyond a cosmological constant and may allow us to increase the dark energy Figure of Merit by at least a factor of three.
△ Less
Submitted 25 November, 2020; v1 submitted 21 October, 2019;
originally announced October 2019.