The Herschel-SPIRE instrument and its in-flight performance
Authors:
M. J. Griffin,
A. Abergel,
A. Abreu,
P. A. R. Ade,
P. André,
J. -L. Augueres,
T. Babbedge,
Y. Bae,
T. Baillie,
J. -P. Baluteau,
M. J. Barlow,
G. Bendo,
D. Benielli,
J. J. Bock,
P. Bonhomme,
D. Brisbin,
C. Brockley-Blatt,
M. Caldwell,
C. Cara,
N. Castro-Rodriguez,
R. Cerulli,
P. Chanial,
S. Chen,
E. Clark,
D. L. Clements
, et al. (154 additional authors not shown)
Abstract:
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-c…
▽ More
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-map**, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
In-flight calibration of the Herschel-SPIRE instrument
Authors:
B. M. Swinyard,
P. Ade,
J-P. Baluteau,
H. Aussel,
M. J. Barlow,
G. J. Bendo,
D. Benielli,
J. Bock,
D. Brisbin,
A. Conley,
L. Conversi,
A. Dowell,
D. Dowell,
M. Ferlet,
T. Fulton,
J. Glenn,
A. Glauser,
D. Griffin,
M. Griffin,
S. Guest,
P. Imhof,
K. Isaak,
S. Jones,
K. King,
S. Leeks
, et al. (33 additional authors not shown)
Abstract:
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space Observatory's submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier transform spectrometer (FTS) covering 194-671 μm (447-1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrument…
▽ More
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space Observatory's submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier transform spectrometer (FTS) covering 194-671 μm (447-1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrument using a combination of the emission from the Herschel telescope itself and the modelled continuum emission from solar system objects and other astronomical targets. We present the photometric, spectroscopic and spatial accuracy that is obtainable in data processed through the "standard" pipelines. The overall photometric accuracy at this stage of the mission is estimated as 15% for the photometer and between 15 and 50% for the spectrometer. However, there remain issues with the photometric accuracy of the spectra of low flux sources in the longest wavelength part of the SPIRE spectrometer band. The spectrometer wavelength accuracy is determined to be better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is found to be 2 arcsec when the latest calibration data are used. The photometric calibration of the SPIRE instrument is currently determined by a combination of uncertainties in the model spectra of the astronomical standards and the data processing methods employed for map and spectrum calibration. Improvements in processing techniques and a better understanding of the instrument performance will lead to the final calibration accuracy of SPIRE being determined only by uncertainties in the models of astronomical standards.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.