Skip to main content

Showing 1–38 of 38 results for author: De Jesus, M

Searching in archive astro-ph. Search in all archives.
.
  1. arXiv:2311.01554  [pdf, other

    physics.ins-det astro-ph.GA

    Characterization of the phonon sensor of the CRYOSEL detector with IR photons

    Authors: Hugues Lattaud, Elsa Guy, Julien Billard, Jules Colas, Maryvonne De Jésus, Jules Gascon, Alexandre Juillard, Stefanos Marnieros, Christine Oriol

    Abstract: The sensitivities of light Dark Matter (DM) particle searches with cryogenic detectors are mostly limited by large backgrounds of events that do not produce ionization signal. The CRYOSEL project develops a new technique where this background in a germanium cryogenic detector is rejected by using the signals from a Superconducting Single Electron Device (SSED) sensor designed to detect the phonons… ▽ More

    Submitted 2 November, 2023; originally announced November 2023.

    Comments: 9 pages, 3 figures, LTD20

    Journal ref: J Low Temp Phys (2024)

  2. arXiv:2306.00166  [pdf, other

    astro-ph.IM

    First demonstration of 30 eVee ionization energy resolution with Ricochet germanium cryogenic bolometers

    Authors: C. Augier, G. Baulieu, V. Belov, L. Bergé, J. Billard, G. Bres, J. -L. Bret, A. Broniatowski, M. Calvo, A. Cazes, D. Chaize, M. Chala, M. Chapellier, L. Chaplinsky, G. Chemin, R. Chen, J. Colas, E. Cudmore, M. De Jesus, P. de Marcillac, L. Dumoulin, O. Exshaw, S. Ferriol, E. Figueroa-Feliciano, J. -B. Filippini , et al. (55 additional authors not shown)

    Abstract: The future Ricochet experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the Ricochet collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector… ▽ More

    Submitted 31 May, 2023; originally announced June 2023.

    Comments: 10 pages, 5 figures, 1 table

  3. arXiv:2303.02067  [pdf, other

    physics.ins-det astro-ph.CO

    Tagging and localisation of ionizing events using NbSi transition edge phonon sensors for Dark Matter searches

    Authors: EDELWEISS Collaboration, C. Augier, A. Benoît, L. Bergé, J. Billard, A. Broniatowski, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, J. Colas, M. De Jésus, L. Dumoulin, K. Eitel, J. B. Filippini, D. Filosofov, J. Gascon, A. Giuliani, M. Gros, E. Guy, Y. **, A. Juillard, H. Lattaud, S. Marnieros, N. Martini , et al. (14 additional authors not shown)

    Abstract: In the context of direct searches of sub-GeV Dark Matter particles with germanium detectors, the EDELWEISS collaboration has tested a new technique to tag ionizing events using NbSi transition edge athermal phonon sensors. The emission of the athermal phonons generated by the Neganov-Trofimov-Luke effect associated with the drift of electrons and holes through the detectors is used to tag ionizati… ▽ More

    Submitted 3 March, 2023; originally announced March 2023.

    Comments: 13 pages, 11 figures

  4. arXiv:2208.01760  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

    Authors: C. Augier, G. Baulieu, V. Belov, L. Berge, J. Billard, G. Bres, J. -L. Bret, A. Broniatowski, M. Calvo, A. Cazes, D. Chaize, M. Chapellier, L. Chaplinsky, G. Chemin, R. Chen, J. Colas, M. De Jesus, P. de Marcillac, L. Dumoulin, O. Exshaw, S. Ferriol, E. Figueroa-Feliciano, J. -B. Filippini, J. A. Formaggio, S. Fuard , et al. (58 additional authors not shown)

    Abstract: The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW resear… ▽ More

    Submitted 2 August, 2022; originally announced August 2022.

    Comments: 14 pages, 14 figures, 1 table

  5. arXiv:2203.07361  [pdf, other

    hep-ph astro-ph.HE hep-ex

    Coherent elastic neutrino-nucleus scattering: Terrestrial and astrophysical applications

    Authors: M. Abdullah, H. Abele, D. Akimov, G. Angloher, D. Aristizabal-Sierra, C. Augier, A. B. Balantekin, L. Balogh, P. S. Barbeau, L. Baudis, A. L. Baxter, C. Beaufort, G. Beaulieu, V. Belov, A. Bento, L. Berge, I. A. Bernardi, J. Billard, A. Bolozdynya, A. Bonhomme, G. Bres, J-. L. Bret, A. Broniatowski, A. Brossard, C. Buck , et al. (250 additional authors not shown)

    Abstract: Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion… ▽ More

    Submitted 14 March, 2022; originally announced March 2022.

    Comments: contribution to Snowmasss 2021. Contact authors: P. S. Barbeau, R. Strauss, L. E. Strigari

  6. Search for sub-GeV Dark Matter via Migdal effect with an EDELWEISS germanium detector with NbSi TES sensors

    Authors: E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, L. Bergé, J. Billard, A. Broniatowski, P. Camus, A. Caze, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, J. B. Filippini, D. Filosofov, J. Gascon, A. Giuliani, M. Gros, E. Guy, Y. **, A. Juillard, M. Kleifges, H. Lattaud, S. Marnieros , et al. (15 additional authors not shown)

    Abstract: The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a Transition… ▽ More

    Submitted 3 October, 2022; v1 submitted 8 March, 2022; originally announced March 2022.

    Comments: 10 pages, 9 figures

    Journal ref: Phys. Rev. D 106, 062004 (2022)

  7. arXiv:2202.05097  [pdf, other

    astro-ph.IM physics.ins-det

    EXCESS workshop: Descriptions of rising low-energy spectra

    Authors: P. Adari, A. Aguilar-Arevalo, D. Amidei, G. Angloher, E. Armengaud, C. Augier, L. Balogh, S. Banik, D. Baxter, C. Beaufort, G. Beaulieu, V. Belov, Y. Ben Gal, G. Benato, A. Benoît, A. Bento, L. Bergé, A. Bertolini, R. Bhattacharyya, J. Billard, I. M. Bloch, A. Botti, R. Breier, G. Bres, J-. L. Bret , et al. (281 additional authors not shown)

    Abstract: Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was… ▽ More

    Submitted 4 March, 2022; v1 submitted 10 February, 2022; originally announced February 2022.

    Comments: 44 pages, 20 figures; Editors: A. Fuss, M. Kaznacheeva, F. Reindl, F. Wagner; updated copyright statements and funding information

    Journal ref: SciPost Phys. Proc. 9, 001 (2022)

  8. arXiv:2003.01046  [pdf, other

    astro-ph.GA astro-ph.IM physics.ins-det

    First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment

    Authors: EDELWEISS Collaboration, Q. Arnaud, E. Armengaud, C. Augier, A. Benoît, L. Bergé, J. Billard, A. Broniatowski, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, E. Elkhoury, J. -B. Fillipini, D. Filosofov, J. Gascon, A. Giuliani, M. Gros, Y. **, A. Juillard, M. Kleifges, H. Lattaud , et al. (17 additional authors not shown)

    Abstract: The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting… ▽ More

    Submitted 10 March, 2022; v1 submitted 2 March, 2020; originally announced March 2020.

    Comments: 6 pages, 4 figures, corrected typos

    Journal ref: Phys. Rev. Lett. 125, 141301 (2020)

  9. arXiv:1901.03588  [pdf, other

    astro-ph.GA astro-ph.IM physics.ins-det

    Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground

    Authors: E. Armengaud, C. Augier, A. Benoît, A. Benoit, L. Bergé, J. Billard, A. Broniatowski, P. Camus, A. Cazes, M. Chapelier, F. Charlieux, D. Ducimetière, L. Dumoulin, K. Eitel, D. Filosofov, J. Gascon, A. Giuliani, M. Gros, M. De Jésus, Y. **, A. Juillard, M. Kleifges, R. Maisonobe, S. Marnieros, D. Misiak , et al. (16 additional authors not shown)

    Abstract: The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding… ▽ More

    Submitted 2 April, 2019; v1 submitted 11 January, 2019; originally announced January 2019.

    Comments: 16 pages, 8 figures. New figure added for Spin-Dependent interactions. Accepted in Phys. Rev. D

    Journal ref: Phys. Rev. D 99, 082003 (2019)

  10. arXiv:1707.04308  [pdf, other

    physics.ins-det astro-ph.CO

    Optimizing EDELWEISS detectors for low-mass WIMP searches

    Authors: EDELWEISS Collaboration, Q. Arnaud, E. Armengaud, C. Augier, A. Benoît, L. Bergé, J. Billard, A. Broniatowski, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, N. Foerster, J. Gascon, A. Giuliani, M. Gros, L. Hehn, Y. **, A. Juillard, M. Kleifges, V. Kozlov, H. Kraus , et al. (18 additional authors not shown)

    Abstract: The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely profile likelihood and boosted decision tree. Both current and achievable experimental performance are considered. The optimal str… ▽ More

    Submitted 11 July, 2017; originally announced July 2017.

    Comments: 21 pages, 12 figures, submitted to Phys. Rev. D

    Journal ref: Phys. Rev. D 97, 022003 (2018)

  11. arXiv:1706.01070  [pdf, other

    physics.ins-det astro-ph.IM

    Performance of the EDELWEISS-III experiment for direct dark matter searches

    Authors: E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, L. Bergé, T. Bergmann, J. Billard, T. de Boissière, G. Bres, A. Broniatowski, V. Brudanin, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, D. Filosofov, N. Foerster, N. Fourches, G. Garde, J. Gascon, A. Giuliani, M. Grollier , et al. (38 additional authors not shown)

    Abstract: We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used… ▽ More

    Submitted 4 June, 2017; originally announced June 2017.

  12. arXiv:1607.04560  [pdf, other

    astro-ph.CO hep-ex nucl-ex physics.ins-det

    Measurement of the cosmogenic activation of germanium detectors in EDELWEISS-III

    Authors: The EDELWEISS Collaboration, E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, L. Bergé, J. Billard, J. Blümer, T. de Boissière, A. Broniatowski, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, N. Foerster, J. Gascon, A. Giuliani, M. Gros, L. Hehn, G. Heuermann, Y. **, A. Juillard , et al. (24 additional authors not shown)

    Abstract: We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for… ▽ More

    Submitted 15 July, 2016; originally announced July 2016.

  13. arXiv:1607.03367  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach

    Authors: EDELWEISS Collaboration, L. Hehn, E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, L. Bergé, J. Billard, J. Blümer, T. de Boissière, A. Broniatowski, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, N. Foerster, J. Gascon, A. Giuliani, M. Gros, G. Heuermann, Y. **, A. Juillard , et al. (24 additional authors not shown)

    Abstract: We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoi… ▽ More

    Submitted 20 September, 2016; v1 submitted 12 July, 2016; originally announced July 2016.

    Comments: 11 pages, 6 figures, 2 tables (updated to accepted version)

    Journal ref: EPJ C (2016) 76:548

  14. arXiv:1606.08097  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM

    Signals induced by charge-trap** in EDELWEISS FID detectors: analytical modeling and applications

    Authors: The EDELWEISS Collaboration, Q. Arnaud, E. Armengaud, C. Augier, A. Benoît, L. Bergé, J. Billard, J. Blümer, T. de Boissière, A. Broniatowski, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, L. Dumoulin, K. Eitel, N. Foerster, N. Fourches, J. Gascon, A. Giuliani, M. Gros, L. Hehn, G. Heuermann, M. De Jésus, Y. ** , et al. (25 additional authors not shown)

    Abstract: The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trap** significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID… ▽ More

    Submitted 29 June, 2016; v1 submitted 26 June, 2016; originally announced June 2016.

    Comments: 17 pages 12 figures, submitted to JINST, author list updated

  15. arXiv:1603.05120  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search

    Authors: EDELWEISS Collaboration, E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, A. Benoît, L. Bergé, T. Bergmann, J. Billard, J. Blümer, T. de Boissière, G. Bres, A. Broniatowski, V. Brudanin, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, L. Dumoulin, K. Eitel, D. Filosofov, N. Foerster, N. Fourches, G. Garde, J. Gascon , et al. (42 additional authors not shown)

    Abstract: We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear rec… ▽ More

    Submitted 9 May, 2016; v1 submitted 16 March, 2016; originally announced March 2016.

    Comments: Matches published version

    Journal ref: JCAP 05 (2016) 019

  16. Axion searches with the EDELWEISS-II experiment

    Authors: E. Armengaud, Q. Arnaud, C. Augier, A. Benoit, A. Benoit, L. Bergé, T. Bergmann, J. Blümer, A. Broniatowski, V. Brudanin, P. Camus, A. Cazes, B. Censier, M. Chapellier, F. Charlieux, F. Couëdo, P. Coulter, G. A. Cox, T. de Boissière, M. De Jesus, Y. Dolgorouky, A. A. Drillien, L. Dumoulin, K. Eitel, D. Filosofov , et al. (41 additional authors not shown)

    Abstract: We present new constraints on the couplings of axions and more generic axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS experiment, located at the Underground Laboratory of Modane, primarily aims at the direct detection of WIMPs using germanium bolometers. It is also sensitive to the low-energy electron recoils that would be induced by solar or dark matter axions. Us… ▽ More

    Submitted 4 July, 2013; originally announced July 2013.

    Journal ref: JCAP 1311 (2013) 067

  17. arXiv:1105.3377  [pdf, ps, other

    astro-ph.CO hep-ex

    Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments

    Authors: CDMS, EDELWEISS Collaborations, :, Z. Ahmed, D. S. Akerib, E. Armengaud, S. Arrenberg, C. Augier, C. N. Bailey, D. Balakishiyeva, L. Baudis, D. A. Bauer, A. Benoît, L. Bergé, J. Blümer, P. L. Brink, A. Broniatowski, T. Bruch, V. Brudanin, R. Bunker, B. Cabrera, D. O. Caldwell, B. Censier, M. Chapellier, G. Chardin , et al. (92 additional authors not shown)

    Abstract: The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon… ▽ More

    Submitted 8 July, 2011; v1 submitted 17 May, 2011; originally announced May 2011.

    Comments: Events, efficiencies, and main limit are available in text format (see README.txt)

    Journal ref: Phys.Rev.D84:011102,2011

  18. Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes

    Authors: EDELWEISS Collaboration, E. Armengaud, C. Augier, A. Benoît, L. Bergé, J. Blümer, A. Broniatowski, V. Brudanin, B. Censier, G. Chardin, M. Chapellier, F. Charlieux, P. Coulter, G. A. Cox, X. Defay, M. De Jesus, Y. Dolgorouki, J. Domange, L. Dumoulin, K. Eitel, D. Filosofov, N. Fourches, J. Gascon, G. Gerbier, J. Gironnet , et al. (27 additional authors not shown)

    Abstract: The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A… ▽ More

    Submitted 31 August, 2011; v1 submitted 21 March, 2011; originally announced March 2011.

    Comments: 23 pages, 5 figures; matches published version

    Journal ref: Physics Letters B 702 (2011) 329-335

  19. A detection system to measure muon-induced neutrons for direct Dark Matter searches

    Authors: V. Yu. Kozlov, E. Armengaud, C. Augier, A. Benoit, L. Berge, O. Besida, J. Blumer, A. Broniatowski, V. Brudanin, A. Chantelauze, M. Chapellier, G. Chardin, F. Charlieux, S. Collin, X. Defay, M. De Jesus, P. Di Stefano, Y. Dolgorouki, J. Domange, L. Dumoulin, K. Eitel, J. Gascon, G. Gerbier, M. Gros, M. Hannawald , et al. (19 additional authors not shown)

    Abstract: Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II ex… ▽ More

    Submitted 15 June, 2010; originally announced June 2010.

    Comments: Accepted for publication in Astroparticle Physics; 14 pages, 10 figures

  20. arXiv:1001.4383  [pdf, ps, other

    astro-ph.IM

    Monitoring of the thermal neutron flux in the LSM underground laboratory

    Authors: S. Rozov, E. Armengaud, C. Augier, L. Bergé, A. Benoit, O. Besida, J. Blümer, A. Broniatowski, V. Brudanin, A. Chantelauze, M. Chapellier, G. Chardin, F. Charlieux, S. Collin, O. Crauste, M. De Jesus, X. Defay, P. Di Stefano, Y. Dolgorouki, J. Domange, L. Dumoulin, K. Eitel, D. Filosofov, J. Gascon, G. Gerbier , et al. (20 additional authors not shown)

    Abstract: This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neut… ▽ More

    Submitted 25 January, 2010; originally announced January 2010.

    Comments: submitted to Journal of Physics G: Nuclear and Particle Physics, 8 pages, 4 figures

  21. arXiv:0912.0805  [pdf, ps, other

    astro-ph.CO astro-ph.GA astro-ph.IM hep-ex

    First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes

    Authors: E. Armengaud, C. Augier, A. Benoit, L. Berge, O. Besida, J. Blumer, A. Broniatowski, A. Chantelauze, M. Chapellier, G. Chardin, F. Charlieux, S. Collin, X. Defay, M. De Jesus, P. Di Stefano, Y. Dolgorouki, J. Domange, L. Dumoulin, K. Eitel, J. Gascon, G. Gerbier, M. Gros, M. Hannawald, S. Herve, A. Juillard , et al. (19 additional authors not shown)

    Abstract: The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effectiv… ▽ More

    Submitted 4 December, 2009; originally announced December 2009.

    Comments: 14 pages, 3 figures. Submitted to Phys Lett. B

    Journal ref: Phys.Lett.B687:294-298,2010

  22. A new high-background-rejection dark matter Ge cryogenic detector

    Authors: A. Broniatowski, X. Defay, E. Armengaud, L. Berge, A. Benoit, O. Besida, J. Blumer, A. Chantelauze, M. Chapellier, G. Chardin, F. Charlieux, S. Collin, O. Crauste, M. De Jesus, P. Di Stefano, Y. Dolgorouki, J. Domange, L. Dumoulin, K. Eitel, J. Gascon, G. Gerbier, M. Gros, M. Hannawald, S. Herve, A. Juillard , et al. (18 additional authors not shown)

    Abstract: A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, a… ▽ More

    Submitted 6 May, 2009; originally announced May 2009.

    Comments: submitted to Physical Review Letters

    Journal ref: Phys.Lett.B681:305-309,2009

  23. Identification of backgrounds in the EDELWEISS-I dark matter search experiment

    Authors: S. Fiorucci, A. Benoit, L. Berge, J. Blumer, A. Broniatowski, B. Censier, A. Chantelauze, M. Chapellier, G. Chardin, S. Collin, X. Defay, M. De Jesus, H. Deschamps, P. Di Stefano, Y. Dolgorouky, L. Dumoulin, K. Eitel, M. Fesquet, J. Gascon, G. Gerbier, C. Goldbach, M. Gros, M. Horn, A. Juillard, R. Lemrani , et al. (14 additional authors not shown)

    Abstract: This paper presents our interpretation and understanding of the different backgrounds in the EDELWEISS-I data sets. We analyze in detail the several populations observed, which include gammas, alphas, neutrons, thermal sensor events and surface events, and try to combine all data sets to provide a coherent picture of the nature and localisation of the background sources. In light of this interpr… ▽ More

    Submitted 10 May, 2007; v1 submitted 27 October, 2006; originally announced October 2006.

    Journal ref: Astropart.Phys.28:143-153,2007

  24. Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils

    Authors: A. Benoit, L. Berge, J. Blumer, A. Broniatowski, B. Censier, A. Chantelauze, M. /Chapellier, G. Chardin, S. Collin, X. Defay, M. De Jesus, H. Deschamps, P. Di Stefano, Y. Dolgorouky, L. Dumoulin, K. Eitel, M. Fesquet, S. Fiorucci, J. Gascon, G. Gerbier, C. Goldbach, M. Gros, M. Horn, A. Juillard, R. Lemrani , et al. (12 additional authors not shown)

    Abstract: The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is fou… ▽ More

    Submitted 21 July, 2006; originally announced July 2006.

    Comments: 28 pages, 7 figures. Submitted to Phys. Rev. D

    Report number: LYCEN 2006-10

    Journal ref: Nucl.Instrum.Meth.A577:558-568,2007

  25. Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors

    Authors: V. Sanglard, A. Benoit, L. Berge, J. Blumer, A. Broniatowski, B. Censier, L. Chabert, M. Chapellier, G. Chardin, P. Charvin, S. Collin, M. De Jesus, H. Deschamps, P. Di Stefano, Y. Dolgorouky, D. Drain, L. Dumoulin, K. Eitel, M. Fesquet, S. Fiorucci, J. Gascon, G. Gerbier, E. Gerlic, C. Goldbach, M. Goyot , et al. (18 additional authors not shown)

    Abstract: The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published results. A recoil energy threshold of 13 keV or better was achieved with three 320g detectors working simultaneously over four months of stable operation. Limits o… ▽ More

    Submitted 26 May, 2005; v1 submitted 11 March, 2005; originally announced March 2005.

    Comments: 42 pages, 16 figures, submitted to Physical Review D, 1 figure and 2 references added, some little changes in the text

    Journal ref: Phys.Rev.D71:122002,2005

  26. Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions

    Authors: A. Benoit, L. Berge, J. Bluemer, A. Broniatowski, B. Censier, L. Chabert, M. Chapellier, G. Chardin, S. Collin, M. De Jesus, H. Deschamps, P. Di Stefano, Y. Dolgorouky, D. Drain, L. Dumoulin, K. Eitel, M. Fesquet, S. Fiorucci, J. Gascon, G. Gerbier, C. Goldbach, M. Gros, R. Gumbsheimer, M. Horn, A. Juillard , et al. (13 additional authors not shown)

    Abstract: The EDELWEISS collaboration is searching for WIMP dark matter using natural Ge cryogenic detectors. The whole data set of the first phase of the experiment contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present (7.8%), high-spin Ge isotope. The sensitivity of the experiment to the spin-dependent WIMP-nucleon interactions is evaluated using the model-independent framework prop… ▽ More

    Submitted 19 April, 2005; v1 submitted 2 December, 2004; originally announced December 2004.

    Comments: v2: new references and figures added, other minor changes. Accepted for publication in Physics Letters B

    Journal ref: Phys.Lett.B616:25-30,2005

  27. Wimp/Neutralino Direct Detection

    Authors: M. De Jesus

    Abstract: The most popular candidate for non baryonic dark matter is the neutralino. More than twenty experiments are dedicated to its direct detection. This review describes the most competitive and promising experiments with different detection techniques. The most recent results are presented with some prospects for the near future.

    Submitted 2 February, 2004; originally announced February 2004.

    Comments: 9 pages, Latex, 12 figures., Review talk presented at the XXIst International Symposium on Lepton and Photon Interactions at High Energies, 11-16 August 2003, FNAL, Batavia, Illinois, USA

    Report number: LYCEN 2003-69

    Journal ref: Int.J.Mod.Phys. A19 (2004) 1142

  28. Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium Detectors for Dark Matter Search

    Authors: The EDELWEISS Collaboration, O. Martineau, A. Benoit, L. Berge, A. Broniatowski, L. Chabert, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, J. Gascon, G. Gerbier, E. Gerlic, C. Goldbach, M. Goyot, M. Gros, J. P. Hadjout, S. Herve, A. Juillard, A. de Lesquen, M. Loidl , et al. (12 additional authors not shown)

    Abstract: Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.

    Submitted 22 October, 2003; originally announced October 2003.

    Comments: 27 pages, Latex, 11 figures. Submitted to NIM A

    Report number: LYCEN 2003-36

    Journal ref: Nucl.Instrum.Meth. A530 (2004) 426-439

  29. SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching Factors using Monoenergetic Neutron Beam

    Authors: E. Simon, L. Berge, A. Broniatowski, R. Bouvier, B. Chambon, M. De Jesus, D. Drain, L. Dumoulin, J. Gascon, J. P. Hadjout, A. Juillard, O. Martineau, C. Pastor, M. Stern, L. Vagneron

    Abstract: SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(… ▽ More

    Submitted 20 December, 2002; originally announced December 2002.

    Comments: 30 pages, Latex, 11 figures. Submitted to NIM A

    Report number: LYCEN 2002-63

    Journal ref: Nucl.Instrum.Meth. A507 (2003) 643-656

  30. Improved Exclusion Limits from the EDELWEISS WIMP Search

    Authors: A. Benoit, L. Berge, A. Broniatowski, L. Chabert, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, J. Gascon, G. Gerbier, E. Gerlic, C. Goldbach, M. Goyot, M. Gros, J. P. Hadjout, S. Herve, A. Juillard, A. de Lesquen, M. Loidl, J. Mallet, S. Marnieros , et al. (10 additional authors not shown)

    Abstract: The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exp… ▽ More

    Submitted 17 June, 2002; originally announced June 2002.

    Comments: 14 pages, Latex, 5 figures. Submitted to Phys. Lett. B

    Report number: LYCEN 2002-31

    Journal ref: Phys.Lett.B545:43-49,2002

  31. 320g Ionization-Heat Cryogenic Detector for Dark Matter Search in the EDELWEISS Experiment

    Authors: O. Martineau, M. Chapellier, G. Chardin, M. De Jesus, J. Gascon, S. Herve, A. Juillard, M. Loidl, X-F. Navick, G. Nollez

    Abstract: The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more than 4 times the mass of previous detectors. Calibrations of this detector are used to determine its energy resolution and fiducial volume, and to optimize the… ▽ More

    Submitted 2 May, 2002; originally announced May 2002.

    Comments: 4 pages, 3 figures

  32. First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector

    Authors: A. Benoit, L. Berge, A. Broniatowski, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, J. Gascon, G. Gerbier, C. Goldbach, M. Goyot, M. Gros, J. P. Hadjout, A. Juillard, A. de Lesquen, M. Loidl, J. Mallet, S. Marnieros, O. Martineau, N. Mirabolfathi, L. Mosca , et al. (6 additional authors not shown)

    Abstract: The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-indepen… ▽ More

    Submitted 6 June, 2001; originally announced June 2001.

    Comments: 14 pages, Latex, 4 figures. Submitted to Phys. Lett. B

    Report number: LYCEN 2001-38

    Journal ref: Phys.Lett.B513:15-22,2001

  33. arXiv:astro-ph/0104192  [pdf, ps, other

    astro-ph

    Dark Matter Search in the EDELWEISS experiment

    Authors: A. Juillard, A. Benoit, L. Berge, A. Bonnevaux, R. Bouvier, A. Broniatowski, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, P. Cluzel, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, J. Gascon, G. Gerbier, C. Goldbach, M. Goyot, M. Gros, J. P. Hadjout, A. De Lesquen, M. Loidl, D. Loiseau, J. Mallet , et al. (11 additional authors not shown)

    Abstract: The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g bolometers are described. After a few weeks of data taking, data accumulated with one of these detectors already allow to reach the upper part of the DAMA region. Pr… ▽ More

    Submitted 11 April, 2001; originally announced April 2001.

    Comments: 4 pages, LaTeX, 3 figures, contribution to " Very High Energy Phenomena in the Universe ", Les Arcs, France (January 20-27, 2001)

    Report number: DAPNIA/SPP-01-03

    Journal ref: Nucl.Phys.Proc.Suppl. 110 (2002) 70-72

  34. arXiv:astro-ph/0101454  [pdf, ps, other

    astro-ph

    The EDELWEISS Experiment : Status and Outlook

    Authors: J. Gascon, A. Benoit, A. Bonnevaux, L. Berge, A. Broniatowski, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, P. Cluzel, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, G. Gerbier, C. Goldbach, M. Goyot, M. Gros, J. P. Hadjout S. Herve, A. Juillard, A. de Lesquen, M. Loidl, J. Mallet, S. Marnieros, O. Martineau , et al. (11 additional authors not shown)

    Abstract: The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.

    Submitted 6 February, 2001; v1 submitted 25 January, 2001; originally announced January 2001.

    Comments: International Conference on Dark Matter in Astro and Particle Physics (Dark 2000), Heidelberg, Germany, 10-16 Jul 2000, v3 minor revisions

  35. Dark Matter Search in the Edelweiss Experiment

    Authors: M. Chapellier, A. Benoit, L. Berge, A. Broniatowski, B. Chambon, G. Chardin, P. Charvin, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, J. Gascon, G. Gerbier, C. Goldbach, M. Goyot, M. Gros, J. P. Hadjout, S. Herve, A. Juillard, A. de Lesquen, M. Loidl, J. Mallet, S. Marnieros, O. Martineau, N. Mirabolfathi , et al. (9 additional authors not shown)

    Abstract: Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking… ▽ More

    Submitted 23 February, 2001; v1 submitted 12 January, 2001; originally announced January 2001.

    Comments: IDM 2000, 3rd International Workshop on the Identification of Dark Matter, York (GB), 18-22/09/2000, v2.0 minor modifications

  36. Background discrimination capabilities of a heat and ionization germanium cryogenic detector

    Authors: P. Di Stefano, L. Berge, B. Chambon, M. Chapellier, J. Chaumont, G. Chardin, P. Charvin, M. De Jesus, D. Drain, L. Dumoulin, P. Forget, P. Garoche, J. Gascon, C. Goldbach, D. L'Hote, J. Mallet, J. Mangin, S. Marnieros, L. Miramonti, L. Mosca, X. -F. Navick, G. Nollez, P. Pari, S. Pecourt, E. Simon , et al. (4 additional authors not shown)

    Abstract: The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the sig… ▽ More

    Submitted 21 April, 2000; originally announced April 2000.

    Comments: Submitted to Astroparticle Physics, 14 pages

    Report number: DAPNIA-00-02

    Journal ref: Astropart.Phys. 14 (2001) 329-337

  37. Event categories in the EDELWEISS WIMP search experiment

    Authors: A. Benoit, L. Berge, A. Broniatowski, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, P. Garoche, J. Gascon, C. Goldbach, M. Gros, A. Juillard, A. de Lesquen, D. L'Hote, L. Mallet, J. Mangin, S. Marnieros, N. Mirabolfathi, L. Miramonti, L. Mosca, X-F. Navick , et al. (6 additional authors not shown)

    Abstract: Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and nuclear interactions occurring in the volume of the detector, and electron and nuclear interactions occurring close to the surface of the detectors(10-20 mu-m of th… ▽ More

    Submitted 24 February, 2000; originally announced February 2000.

    Comments: 11 pages, submitted to Phys. Lett. B

    Report number: DAPNIA-00-01

    Journal ref: Phys.Lett.B479:8-14,2000

  38. Status of the EDELWEISS Experiment

    Authors: L. Berge, I. Berkes, B. Chambon, M. Chapellier, G. Chardin, P. Charvin, M. De Jesus, P. Di Stefano, D. Drain, L. Dumoulin, C. Goldbach, A. Juillard, D. L'Hote, S. Marnieros, L. Miramonti, L. Mosca, X. -F. Navick, G. Nollez, P. Pari, C. Pastor, S. Pecourt, R. Tourbot, D. Yvon

    Abstract: The status of the EDELWEISS experiment (underground dark matter search with heat-ionisation bolometers) is reviewed. Auspicious results achieved with a prototype 70 g Ge heat-ionisation detector under a 2 V reverse bias tension are discussed. Based on gamma and neutron calibrations, a best-case rejection factor, over the 15-45 keV range, of 99.7 % for gammas, with an acceptance of 94 % for neutr… ▽ More

    Submitted 21 January, 1998; originally announced January 1998.

    Comments: 5 pages, 4 eps figures, LaTeX requires espcrc2.sty; Proceedings of TAUP97, Gran Sasso, Italy, September 7-11, 1997

    Report number: DAPNIA-SPP 98_04

    Journal ref: Nucl.Phys.Proc.Suppl. 70 (1999) 69-73