-
The design and performance of the XL-Calibur anticoincidence shield
Authors:
N. K. Iyer,
M. Kiss,
M. Pearce,
T. -A. Stana,
H. Awaki,
R. G. Bose,
A. Dasgupta,
G. De Geronimo,
E. Gau,
T. Hakamata,
M. Ishida,
K. Ishiwata,
W. Kamogawa,
F. Kislat,
T. Kitaguchi,
H. Krawczynski,
L. Lisalda,
Y. Maeda,
H. Matsumoto,
A. Miyamoto,
T. Miyazawa,
T. Mizuno,
B. F. Rauch,
N. Rodriguez Cavero,
N. Sakamoto
, et al. (9 additional authors not shown)
Abstract:
The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincide…
▽ More
The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ~0.5 Hz (20-40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight
Authors:
Quincy Abarr,
Banafsheh Beheshtipour,
Matthias Beilicke,
Richard Bose,
Dana Braun,
Gianluigi de Geronimo,
Paul Dowkontt,
Manel Errando,
Thomas Gadson,
Victor Guarino,
Scott Heatwole,
Md. Arman Hossen,
Nirmal K. Iyer,
Fabian Kislat,
Mózsi Kiss,
Takao Kitaguchi,
Henric Krawczynski,
R. James Lanzi,
Shaorui Li,
Lindsey Lisalda,
Takashi Okajima,
Mark Pearce,
Zachary Peterson,
Logan Press,
Brian Rauch
, et al. (6 additional authors not shown)
Abstract:
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launche…
▽ More
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.
△ Less
Submitted 20 April, 2022;
originally announced April 2022.
-
XL-Calibur -- a second-generation balloon-borne hard X-ray polarimetry mission
Authors:
Q. Abarr,
H. Awaki,
M. G. Baring,
R. Bose,
G. De Geronimo,
P. Dowkontt,
M. Errando,
V. Guarino,
K. Hattori,
K. Hayashida,
F. Imazato,
M. Ishida,
N. K. Iyer,
F. Kislat,
M. Kiss,
T. Kitaguchi,
H. Krawczynski,
L. Lisalda,
H. Matake,
Y. Maeda,
H. Matsumoto,
T. Mineta,
T. Miyazawa,
T. Mizuno,
T. Okajima
, et al. (16 additional authors not shown)
Abstract:
XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301-2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprisin…
▽ More
XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301-2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprising a beryllium rod surrounded by Cadmium Zinc Telluride (CZT) detectors. The polarimeter is housed in an anticoincidence shield to mitigate background from particles present in the stratosphere. The mirror and polarimeter-shield assembly are mounted at opposite ends of a 12 m long lightweight truss, which is pointed with arcsecond precision by WASP - the Wallops Arc Second Pointer. The XL-Calibur mission will achieve a substantially improved sensitivity over X-Calibur by using a larger effective area X-ray mirror, reducing background through thinner CZT detectors, and improved anticoincidence shielding. When observing a 1 Crab source for $t_{\rm day}$ days, the Minimum Detectable Polarisation (at 99% confidence level) is $\sim$2$\%\cdot t_{\rm day}^{-1/2}$. The energy resolution at 40 keV is $\sim$5.9 keV. The aim of this paper is to describe the design and performance of the XL-Calibur mission, as well as the foreseen science programme.
△ Less
Submitted 20 October, 2020;
originally announced October 2020.
-
Design of the telescope truss and gondola for the balloon-borne X-ray polarimeter X-Calibur
Authors:
Fabian Kislat,
Banafsheh Beheshtipour,
Paul Dowkontt,
Victor Guarino,
R. James Lanzi,
Takashi Okajima,
Dana Braun,
Scott Cannon,
Gialuigi De Geronimo,
Scott Heatwole,
Janie Hoorman,
Shaorui Li,
Hideyuki Mori,
Christopher M. Shreves,
David Stuchlik,
Henric Krawczynski
Abstract:
X-ray polarimetry has seen a growing interest in recent years. Improvements in detector technology and focusing X-ray optics now enable sensitive astrophysical X-ray polarization measurements. These measurements will provide new insights into the processes at work in accreting black holes, the emission of X-rays from neutron stars and magnetars, and the structure of AGN jets. X-Calibur is a balloo…
▽ More
X-ray polarimetry has seen a growing interest in recent years. Improvements in detector technology and focusing X-ray optics now enable sensitive astrophysical X-ray polarization measurements. These measurements will provide new insights into the processes at work in accreting black holes, the emission of X-rays from neutron stars and magnetars, and the structure of AGN jets. X-Calibur is a balloon-borne hard X-ray scattering polarimeter. An X-ray mirror with a focal length of 8 m focuses X-rays onto the detector, which consists of a plastic scattering element surrounded by Cadmium-Zinc-Telluride detectors, which absorb and record the scattered X-rays. Since X-rays preferentially scatter perpendicular to their polarization direction, the polarization properties of an X-ray beam can be inferred from the azimuthal distribution of scattered X-rays. A close alignment of the X-ray focal spot with the center of the detector is required in order to reduce systematic uncertainties and to maintain a high photon detection efficiency. This places stringent requirements on the mechanical and thermal stability of the telescope structure. During the flight on a stratospheric balloon, X-Calibur makes use of the Wallops Arc-Second Pointer (WASP) to point the telescope at astrophysical sources. In this paper, we describe the design, construction, and test of the telescope structure, as well as its performance during a 25-hour flight from Ft. Sumner, New Mexico. The carbon fiber-aluminum composite structure met the requirements set by X-Calibur and its design can easily be adapted for other types of experiments, such as X-ray imaging or spectroscopic telescopes.
△ Less
Submitted 17 January, 2017;
originally announced January 2017.
-
Optimization of <= 200 um pitch CZT detectors for future high-resolution X-ray instrumentation in astrophysics
Authors:
Anna Zajczyk,
Marie Draper,
Paul Dowkontt,
Qingzhen Guo,
Fabian Kislat,
Henric Krawczynski,
Gianluigi De Geronimo,
Shaorui Li,
Matthias Beilicke
Abstract:
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about…
▽ More
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of <= 250um. Additional detector requirements include a low energy threshold of less than 5keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this contribution, we report on our R&D studies with the goal to optimise small-pixel Cadmium Zinc Telluride and Cadmium Telluride detectors.
△ Less
Submitted 14 January, 2015;
originally announced January 2015.
-
Design and Performance of the X-ray polarimeter X-Calibur
Authors:
Matthias Beilicke,
F. Kislat,
A. Zajczyk,
Q. Guo,
R. Endsley,
M. Stork,
R. Cowsik,
P. Dowkontt,
S. Barthelmy,
T. Hams,
T. Okajima,
M. Sasaki,
B. Zeiger,
G. De Geronimo,
M. G. Baring,
H. Krawczynski
Abstract:
X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope. X-Calibur combines a low-Z…
▽ More
X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope. X-Calibur combines a low-Z scatterer with a CZT detector assembly to measure the polarization of 20-80keV X-rays making use of the fact that polarized photons scatter preferentially perpendicular to the electric field orientation. X-Calibur achieves a high detection efficiency of ~80%. The X-Calibur detector assembly is completed, tested, and fully calibrated. The response to a polarized X-ray beam was measured successfully at the Cornell High Energy Synchrotron Source. This paper describes the design, calibration and performance of the X-Calibur polarimeter. In principle, a similar space-borne scattering polarimeter could operate over the broader 2-100keV energy band.
△ Less
Submitted 19 December, 2014;
originally announced December 2014.
-
Study of Thick CZT Detectors for X-ray and Gamma-Ray Astronomy
Authors:
Qiang Li,
M. Beilicke,
Kuen Lee,
Alfred Garson III,
Q. Guo,
Jerrad Martin,
Y. Yin,
P. Dowkontt,
G. De Geronimo,
I. Jung,
H. Krawczynski
Abstract:
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and γ-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT detectors for the detection of 15-150 keV X-rays from Gamma-Ray Bursts. We report on the systematic tests of thicker (\geq 0.5 cm) CZT detectors with volumes between 2 cm3 and 4 cm3 which…
▽ More
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and γ-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT detectors for the detection of 15-150 keV X-rays from Gamma-Ray Bursts. We report on the systematic tests of thicker (\geq 0.5 cm) CZT detectors with volumes between 2 cm3 and 4 cm3 which are potential detector choices for a number of future X-ray telescopes that operate in the 10 keV to a few MeV energy range. The detectors contacted in our laboratory achieve Full Width Half Maximum energy resolutions of 2.7 keV (4.5%) at 59 keV, 3 keV (2.5%) at 122 keV and 4 keV (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are among the world-best results for \geq 0.5 cm thick CZT detectors. We use the data set to study trends of how the energy resolution depends on the detector thickness and on the pixel pitch. Unfortunately, we do not find clear trends, indicating that even for the extremely good energy resolutions reported here, the achievable energy resolutions are largely determined by the properties of individual crystals. Somewhat surprisingly, we achieve the reported results without applying a correction of the anode signals for the depth of the interaction. Measuring the interaction depths thus does not seem to be a pre-requisite for achieving sub-1% energy resolutions at 662 keV.
△ Less
Submitted 8 February, 2011;
originally announced February 2011.
-
AXTAR: Mission Design Concept
Authors:
Paul S. Ray,
Deepto Chakrabarty,
Colleen A. Wilson-Hodge,
Bernard F. Phlips,
Ronald A. Remillard,
Alan M. Levine,
Kent S. Wood,
Michael T. Wolff,
Chul S. Gwon,
Tod E. Strohmayer,
Michael Baysinger,
Michael S. Briggs,
Peter Capizzo,
Leo Fabisinski,
Randall C. Hopkins,
Linda S. Hornsby,
Les Johnson,
C. Dauphne Maples,
Janie H. Miernik,
Dan Thomas,
Gianluigi De Geronimo
Abstract:
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at…
▽ More
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at the natural time scales of neutron star surfaces and black hole event horizons, thus probing the physics of ultradense matter, strongly curved spacetimes, and intense magnetic fields. AXTAR's main instrument, the Large Area Timing Array (LATA) is a collimated instrument with 2-50 keV coverage and over 3 square meters effective area. The LATA is made up of an array of supermodules that house 2-mm thick silicon pixel detectors. AXTAR will provide a significant improvement in effective area (a factor of 7 at 4 keV and a factor of 36 at 30 keV) over the RXTE PCA. AXTAR will also carry a sensitive Sky Monitor (SM) that acts as a trigger for pointed observations of X-ray transients in addition to providing high duty cycle monitoring of the X-ray sky. We review the science goals and technical concept for AXTAR and present results from a preliminary mission design study.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
HX-POL - A Balloon-Borne Hard X-Ray Polarimeter
Authors:
H. Krawczynski,
A. Garson III,
Q. Li,
M. Beilicke,
P. Dowkontt,
E. Wulf,
J. Kurfess,
E. Novikova,
G. De Geronimo,
M. G. Baring,
A. K. Harding,
J. Grindlay,
J. S. Hong
Abstract:
We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-…
▽ More
We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.
△ Less
Submitted 3 June, 2010; v1 submitted 9 December, 2008;
originally announced December 2008.
-
Fabrication and Test of Pixelated CZT Detectors with Different Pixel Pitches and Thicknesses
Authors:
Q. Li,
A. Garson,
P. Dowkontt,
J. Martin,
M. Beilicke,
I. Jung,
M. Groza,
A. Burger,
G. De Geronimo,
H. Krawczynski,
.,
.,
.,
.
Abstract:
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system based on two 32-channel NCI-ASICs for pixellated CZT detector arrays has been developed and tested. The CZT detectors supplied by Orbotech (MHB) and eV produ…
▽ More
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system based on two 32-channel NCI-ASICs for pixellated CZT detector arrays has been developed and tested. The CZT detectors supplied by Orbotech (MHB) and eV products (HPB) are tested by NCI-ASIC readout system. The CZT detectors have an array of 8x8 or 11x11 pixel anodes fabricated on the anode surface with the area up to 2 cm x2 cm and the thickness of CZT detectors ranges from 0.5 cm to 1 cm. Energy spectra resolution and electron mobility-lifetime products of 8x8 pixels CZT detector with different thicknesses have been investigated.
△ Less
Submitted 19 November, 2008;
originally announced November 2008.