-
Dense molecular gas properties on 100 pc scales across the disc of NGC 3627
Authors:
I. Bešlić,
A. T. Barnes,
F. Bigiel,
J. Puschnig,
J. Pety,
C. Herrera Contreras,
A. K. Leroy,
A. Usero,
E. Schinnerer,
S. E. Meidt,
E. Emsellem,
A. Hughes,
C. Faesi,
K. Kreckel,
F. M. C. Belfiore,
M. Chevance,
J. S. den Brok,
C. Eibensteiner,
S. C. O. Glover,
K. Grasha,
M. J. Jimenez-Donaire,
R. S. Klessen,
J. M. D. Kruijssen,
D. Liu,
I. Pessa
, et al. (7 additional authors not shown)
Abstract:
It is still poorly constrained how the densest phase of the interstellar medium varies across galactic environment. A large observing time is required to recover significant emission from dense molecular gas at high spatial resolution, and to cover a large dynamic range of extragalactic disc environments. We present new NOrthern Extended Millimeter Array (NOEMA) observations of a range of high cri…
▽ More
It is still poorly constrained how the densest phase of the interstellar medium varies across galactic environment. A large observing time is required to recover significant emission from dense molecular gas at high spatial resolution, and to cover a large dynamic range of extragalactic disc environments. We present new NOrthern Extended Millimeter Array (NOEMA) observations of a range of high critical density molecular tracers (HCN, HNC, HCO+) and CO isotopologues (13CO, C18O) towards the nearby (11.3 Mpc), strongly barred galaxy NGC 3627. These observations represent the current highest angular resolution (1.85"; 100 pc) map of dense gas tracers across a disc of a nearby spiral galaxy, which we use here to assess the properties of the dense molecular gas, and their variation as a function of galactocentric radius, molecular gas, and star formation. We find that the HCN(1-0)/CO(2-1) integrated intensity ratio does not correlate with the amount of recent star formation. Instead, the HCN(1-0)/CO(2-1) ratio depends on the galactic environment, with differences between the galaxy centre, bar, and bar end regions. The dense gas in the central 600 pc appears to produce stars less efficiently despite containing a higher fraction of dense molecular gas than the bar ends where the star formation is enhanced. In assessing the dynamics of the dense gas, we find the HCN(1-0) and HCO+(1-0) emission lines showing multiple components towards regions in the bar ends that correspond to previously identified features in CO emission. These features are co-spatial with peaks of Halpha emission, which highlights that the complex dynamics of this bar end region could be linked to local enhancements in the star formation.
△ Less
Submitted 17 June, 2021;
originally announced June 2021.
-
Physics reach of the XENON1T dark matter experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
L. Arazi,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
T. Berger,
P. Breur,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon
, et al. (91 additional authors not shown)
Abstract:
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and (…
▽ More
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_χ$=$50$ GeV/$c^2$.
△ Less
Submitted 15 April, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
Authors:
The XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
M. Anthony,
L. Arazi,
K. Arisaka,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Coderre,
A. P. Colijn,
H. Contreras
, et al. (77 additional authors not shown)
Abstract:
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to ide…
▽ More
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
Authors:
The XENON Collaboration,
E. Aprile,
F. Agostini,
M. Alfonsi,
L. Arazi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Coderre,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau
, et al. (76 additional authors not shown)
Abstract:
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic re…
▽ More
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2 GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
L. Arazi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
D. Coderre,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowksi
, et al. (73 additional authors not shown)
Abstract:
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experime…
▽ More
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni
, et al. (66 additional authors not shown)
Abstract:
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for W…
▽ More
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
△ Less
Submitted 25 February, 2015; v1 submitted 9 June, 2014;
originally announced June 2014.
-
First Axion Results from the XENON100 Experiment
Authors:
The XENON100 Collaboration,
E. Aprile,
F. Agostini,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni
, et al. (65 additional authors not shown)
Abstract:
We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been probed by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90\% C…
▽ More
We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been probed by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For axion-like-particles, under the assumption that they constitute the whole abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than $1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set the best limit to date as well.
△ Less
Submitted 22 December, 2016; v1 submitted 5 April, 2014;
originally announced April 2014.
-
Observation and applications of single-electron charge signals in the XENON100 experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (55 additional authors not shown)
Abstract:
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector…
▽ More
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
△ Less
Submitted 28 January, 2014; v1 submitted 5 November, 2013;
originally announced November 2013.
-
The neutron background of the XENON100 dark matter experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione
, et al. (52 additional authors not shown)
Abstract:
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission re…
▽ More
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
△ Less
Submitted 2 September, 2013; v1 submitted 10 June, 2013;
originally announced June 2013.
-
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Authors:
The XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori
, et al. (58 additional authors not shown)
Abstract:
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A ve…
▽ More
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
△ Less
Submitted 18 July, 2013; v1 submitted 4 April, 2013;
originally announced April 2013.
-
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
Authors:
XENON100 collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (53 additional authors not shown)
Abstract:
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to th…
▽ More
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x 10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
△ Less
Submitted 29 January, 2013; v1 submitted 28 January, 2013;
originally announced January 2013.
-
The distributed Slow Control System of the XENON100 Experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. M. Bruno,
R. Budnik,
M. Le Calloch,
J. M. Cardoso,
W. -T. Chen,
B. Choi,
H. Contreras,
J. -P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione,
F. Gao,
M. Garbini
, et al. (50 additional authors not shown)
Abstract:
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature…
▽ More
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon
Authors:
E. Aprile,
R. Budnik,
B. Choi,
H. A. Contreras,
K. -L. Giboni,
L. W. Goetzke,
J. E. Koglin,
R. F. Lang,
K. E. Lim,
A. J. Melgarejo Fernandez,
R. Persiani,
G. Plante,
A. Rizzo
Abstract:
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs γ rays and the energy of the Compton-scattered γ rays was measured with a high-purity germanium (HPGe) detector placed at di…
▽ More
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs γ rays and the energy of the Compton-scattered γ rays was measured with a high-purity germanium (HPGe) detector placed at different scattering angles. The excellent energy resolution of the HPGe detector allows the selection of events with Compton electrons of known energy in the LXe detector. We find that the scintillation yield initially increases as the electron energy decreases from 120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The measured scintillation yield was also measured with conversion electrons from the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal calibration source. We find that the scintillation yield of the 32.1 keV transition is compatible with that obtained from the Compton coincidence measurement. On the other hand, the yield for the 9.4keV transition is much higher than that measured for a Compton electron of the same energy. We interpret the enhancement in the scintillation yield as due to the enhanced recombination rate in the presence of Xe ions left from the 32.1 keV transition, which precedes the 9.4 keV one by 220 ns, on average.
△ Less
Submitted 17 September, 2012;
originally announced September 2012.
-
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Authors:
The XENON Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (52 additional authors not shown)
Abstract:
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the ratio…
▽ More
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
△ Less
Submitted 28 August, 2012;
originally announced August 2012.
-
Dark Matter Results from 225 Live Days of XENON100 Data
Authors:
XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (53 additional authors not shown)
Abstract:
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence…
▽ More
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
△ Less
Submitted 20 March, 2013; v1 submitted 25 July, 2012;
originally announced July 2012.
-
Measurement of the Quantum Efficiency of Hamamatsu R8520 Photomultipliers at Liquid Xenon Temperature
Authors:
E. Aprile,
M. Beck,
K. Bokeloh,
R. Budnik,
B. Choi,
H. A. Contreras,
K. -L. Giboni,
L. W. Goetzke,
R. F. Lang,
K. E. Lim,
A. J. Melgarejo Fernandez,
G. Plante,
A. Rizzo,
P. Shagin,
C. Weinheimer
Abstract:
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to liquid xenon are being used to efficiently detect the 178 nm scintillation light in a variety of liquid xenon based particle detectors. Good knowledge of the performance of these photomultipliers under cryogenic conditions is needed to properly characterize these detectors. Here, we report on measurements of the quantum e…
▽ More
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to liquid xenon are being used to efficiently detect the 178 nm scintillation light in a variety of liquid xenon based particle detectors. Good knowledge of the performance of these photomultipliers under cryogenic conditions is needed to properly characterize these detectors. Here, we report on measurements of the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON Dark Matter Experiments. The quantum efficiency measurements at room temperature agree with the values provided by Hamamatsu. At low temperatures, between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative to the room temperature values.
△ Less
Submitted 23 July, 2012;
originally announced July 2012.
-
Analysis of the XENON100 Dark Matter Search Data
Authors:
The XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. B. Cline,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione,
F. Gao
, et al. (49 additional authors not shown)
Abstract:
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have…
▽ More
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
△ Less
Submitted 14 October, 2013; v1 submitted 14 July, 2012;
originally announced July 2012.
-
Inspiral of Generic Black Hole Binaries: Spin, Precession, and Eccentricity
Authors:
Janna Levin,
Sean T. McWilliams,
Hugo Contreras
Abstract:
Given the absence of observations of black hole binaries, it is critical that the full range of accessible parameter space be explored in anticipation of future observation with gravitational wave detectors. To this end, we compile the Hamiltonian equations of motion describing the conservative dynamics of the most general black hole binaries, as computed by Will and collaborators, and incorporate…
▽ More
Given the absence of observations of black hole binaries, it is critical that the full range of accessible parameter space be explored in anticipation of future observation with gravitational wave detectors. To this end, we compile the Hamiltonian equations of motion describing the conservative dynamics of the most general black hole binaries, as computed by Will and collaborators, and incorporate an effective treatment of dissipation through gravitational radiation. We evolve these equations for systems with orbital eccentricity and precessing spins. We find that, while spin-spin coupling corrections can destroy constant radius orbits in principle, the effect is so small that orbits will reliably tend to quasi-spherical orbits as angular momentum and energy are lost to gravitational radiation. Still, binaries that are initially highly eccentric may retain eccentricity as they pass into the detectable bandwidth of ground-based gravitational wave detectors. We also show that a useful set of natural frequencies for an orbit demonstrating both spin precession and periastron precession is comprised of (1) the frequency of angular motion in the orbital plane, (2) the frequency of the plane precession, and (3) the frequency of radial oscillations. These three natural harmonics shape the observed waveform.
△ Less
Submitted 28 July, 2011; v1 submitted 13 September, 2010;
originally announced September 2010.