Acoustic and optical variations during rapid downward motion episodes in the deep north-western Mediterranean Sea
Authors:
H. van Haren,
I. Taupier-Letage,
J. A. Aguilar,
A. Albert,
M. Anghinolfi,
G. Anton,
S. Anvar,
M. Ardid,
A. C. Assis Jesus,
T. Astraatmadja,
J. -J. Aubert,
R. Auer,
B. Baret,
S. Basa,
M. Bazzotti,
V. Bertin,
S. Biagi,
C. Bigongiari,
M. Bou-Cabof,
M. C. Bouwhuis,
A. Brown,
J. Brunner,
J. Busto,
F. Camarena,
A. Capone
, et al. (116 additional authors not shown)
Abstract:
An Acoustic Doppler Current Profiler (ADCP) was moored at the deep-sea site of the ANTARES neutrino telescope near Toulon, France, thus providing a unique opportunity to compare high-resolution acoustic and optical observations between 70 and 170 m above the sea bed at 2475 m. The ADCP measured downward vertical currents of magnitudes up to 0.03 m s-1 in late winter and early spring 2006. In the s…
▽ More
An Acoustic Doppler Current Profiler (ADCP) was moored at the deep-sea site of the ANTARES neutrino telescope near Toulon, France, thus providing a unique opportunity to compare high-resolution acoustic and optical observations between 70 and 170 m above the sea bed at 2475 m. The ADCP measured downward vertical currents of magnitudes up to 0.03 m s-1 in late winter and early spring 2006. In the same period, observations were made of enhanced levels of acoustic reflection, interpreted as suspended particles including zooplankton, by a factor of about 10 and of horizontal currents reaching 0.35 m s-1. These observations coincided with high light levels detected by the telescope, interpreted as increased bioluminescence. During winter 2006 deep dense-water formation occurred in the Ligurian subbasin, thus providing a possible explanation for these observations. However, the 10-20 days quasi-periodic episodes of high levels of acoustic reflection, light and large vertical currents continuing into the summer are not direct evidence of this process. It is hypothesized that the main process allowing for suspended material to be moved vertically later in the year is local advection, linked with topographic boundary current instabilities along the rim of the 'Northern Current'.
△ Less
Submitted 28 November, 2011;
originally announced November 2011.
High Precision CTE-Measurement of SiC-100 for Cryogenic Space-Telescopes
Authors:
K. Enya,
N. Yamada,
T. Onaka,
T. Nakagawa,
H. Kaneda,
M. Hirabayashi,
Y. Toulemont,
D. Castel,
Y. Kanai,
N. Fujishiro
Abstract:
We present the results of high precision measurements of the thermal expansion of the sintered SiC, SiC-100, intended for use in cryogenic space-telescopes, in which minimization of thermal deformation of the mirror is critical and precise information of the thermal expansion is needed for the telescope design. The temperature range of the measurements extends from room temperature down to…
▽ More
We present the results of high precision measurements of the thermal expansion of the sintered SiC, SiC-100, intended for use in cryogenic space-telescopes, in which minimization of thermal deformation of the mirror is critical and precise information of the thermal expansion is needed for the telescope design. The temperature range of the measurements extends from room temperature down to $\sim$ 10 K. Three samples, #1, #2, and #3 were manufactured from blocks of SiC produced in different lots. The thermal expansion of the samples was measured with a cryogenic dilatometer, consisting of a laser interferometer, a cryostat, and a mechanical cooler. The typical thermal expansion curve is presented using the 8th order polynomial of the temperature. For the three samples, the coefficients of thermal expansion (CTE), $\barα_{#1}$, $\barα_{#2}$, and $\barα_{#3}$ were derived for temperatures between 293 K and 10 K. The average and the dispersion (1 $σ$ rms) of these three CTEs are 0.816 and 0.002 ($\times 10^{-6}$/K), respectively. No significant difference was detected in the CTE of the three samples from the different lots. Neither inhomogeneity nor anisotropy of the CTE was observed. Based on the obtained CTE dispersion, we performed an finite-element-method (FEM) analysis of the thermal deformation of a 3.5 m diameter cryogenic mirror made of six SiC-100 segments. It was shown that the present CTE measurement has a sufficient accuracy well enough for the design of the 3.5 m cryogenic infrared telescope mission, the Space Infrared telescope for Cosmology and Astrophysics (SPICA).
△ Less
Submitted 11 April, 2007;
originally announced April 2007.