-
Coherent elastic neutrino-nucleus scattering: Terrestrial and astrophysical applications
Authors:
M. Abdullah,
H. Abele,
D. Akimov,
G. Angloher,
D. Aristizabal-Sierra,
C. Augier,
A. B. Balantekin,
L. Balogh,
P. S. Barbeau,
L. Baudis,
A. L. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
A. Bento,
L. Berge,
I. A. Bernardi,
J. Billard,
A. Bolozdynya,
A. Bonhomme,
G. Bres,
J-. L. Bret,
A. Broniatowski,
A. Brossard,
C. Buck
, et al. (250 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion source with CsI detectors, followed up the detection of CE$ν$NS using an Ar target. The detection of CE$ν$NS has spawned a flurry of activities in high-energy physics, inspiring new constraints on beyond the Standard Model (BSM) physics, and new experimental methods. The CE$ν$NS process has important implications for not only high-energy physics, but also astrophysics, nuclear physics, and beyond. This whitepaper discusses the scientific importance of CE$ν$NS, highlighting how present experiments such as COHERENT are informing theory, and also how future experiments will provide a wealth of information across the aforementioned fields of physics.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
New method of 85Kr reduction in a noble gas based low-background detector
Authors:
D. Yu. Akimov,
A. I. Bolozdynya,
A. A. Burenkov,
C. Hall,
A. G. Kovalenko,
V. V. Kuzminov,
G. E. Simakov
Abstract:
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much lar…
▽ More
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much larger than the natural krypton that is already present. After the purification system reduces the total Kr concentration to the same level, the final 85Kr concentration will have been reduced even further by the dilution factor. A test cell for measurement of the activity of various Kr samples has been assembled, and the activity of 25-year-old Krypton has been measured. The measured activity agrees well with the expected activity accounting for the 85Kr abundance of the earth atmosphere in 1990 and the half-life of the isotope. Additional tests with a Kr sample produced in the year 1944 (before the atomic era) have been done in order to demonstrate the sensitivity of the test cell.
△ Less
Submitted 22 November, 2016;
originally announced November 2016.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.
-
The LUX Prototype Detector: Heat Exchanger Development
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
S. Cahn,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
A. Curioni,
C. E. Dahl,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
S. Fiorucci,
R. J. Gaitskell,
C. Hall,
C. Faham,
B. Holbrook,
L. Kastens,
K. Kazkaz,
J. Kwong
, et al. (25 additional authors not shown)
Abstract:
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for ac…
▽ More
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.
△ Less
Submitted 20 January, 2013; v1 submitted 16 July, 2012;
originally announced July 2012.
-
A search for light dark matter in XENON10 data
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_χ=8 GeV. We f…
▽ More
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_χ=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
△ Less
Submitted 7 May, 2013; v1 submitted 15 April, 2011;
originally announced April 2011.
-
Lowering the low-energy threshold of xenon detectors
Authors:
P. Sorensen,
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey
, et al. (12 additional authors not shown)
Abstract:
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This me…
▽ More
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
△ Less
Submitted 29 November, 2010;
originally announced November 2010.
-
Low-threshold analysis of CDMS shallow-site data
Authors:
CDMS Collaboration,
D. S. Akerib,
M. J. Attisha,
L. Baudis,
D. A. Bauer,
A. I. Bolozdynya,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
C. L. Chang,
R. M. Clarke,
J. Cooley,
M. B. Crisler,
P. Cushman,
F. DeJongh,
R. Dixon,
D. D. Driscoll,
J. Filippini,
S. Funkhouser,
R. J. Gaitskell,
S. R. Golwala,
D. Holmgren,
L. Hsu,
M. E. Huber
, et al. (23 additional authors not shown)
Abstract:
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the ge…
▽ More
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments' data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c^2 and 4 GeV/c^2.
△ Less
Submitted 3 January, 2011; v1 submitted 20 October, 2010;
originally announced October 2010.
-
Design and Performance of the XENON10 Dark Matter Experiment
Authors:
E. Aprile,
J. Angle,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (14 additional authors not shown)
Abstract:
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been publ…
▽ More
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
△ Less
Submitted 16 January, 2010;
originally announced January 2010.
-
Status of the LUX Dark Matter Search
Authors:
S. Fiorucci,
D. S. Akerib,
S. Bedikian,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Carr,
J. Chapman,
K. Clark,
T. Classen,
A. Curioni,
E. Dahl,
S. Dazeley,
L. de Viveiros,
E. Druszkiewicz,
R. Gaitskell,
C. Hall,
C. Hernandez Faham,
B. Holbrook,
L. Kastens,
K. Kazkaz,
R. Lander,
K. Lesko,
D. Malling,
R. Mannino
, et al. (22 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within v…
▽ More
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.
△ Less
Submitted 2 December, 2009;
originally announced December 2009.
-
Constraints on inelastic dark matter from XENON10
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of…
▽ More
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_χ\gtrsim150$ GeV are disfavored.
△ Less
Submitted 30 November, 2010; v1 submitted 19 October, 2009;
originally announced October 2009.
-
Scintillation Pulse Shape Discrimination in a Two-Phase Xenon Time Projection Chamber
Authors:
J. Kwong,
P. Brusov,
T. Shutt,
C. E. Dahl,
A. I. Bolozdynya,
A. Bradley
Abstract:
The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio simultaneously to obtain a leakage below that achievable by either discriminant alone. A Monte Carlo is used to show that the dominant fluctuation in the pulse shape…
▽ More
The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio simultaneously to obtain a leakage below that achievable by either discriminant alone. A Monte Carlo is used to show that the dominant fluctuation in the pulse shape quantity is statistical in nature, and project the performance of these techniques in larger detectors. Although the performance is generally weak at low energies relevant to elastic WIMP recoil searches, the pulse shape can be used in probing for higher energy inelastic WIMP recoils.
△ Less
Submitted 6 August, 2009;
originally announced August 2009.
-
The scintillation and ionization yield of liquid xenon for nuclear recoils
Authors:
P. Sorensen,
A. Manzur,
C. E. Dahl,
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
D. N. McKinsey
, et al. (12 additional authors not shown)
Abstract:
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relati…
▽ More
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
△ Less
Submitted 30 December, 2008; v1 submitted 3 July, 2008;
originally announced July 2008.
-
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of…
▽ More
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
△ Less
Submitted 10 September, 2008; v1 submitted 19 May, 2008;
originally announced May 2008.
-
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind…
▽ More
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
△ Less
Submitted 3 December, 2007; v1 submitted 31 May, 2007;
originally announced June 2007.
-
3D Position Sensitive XeTPC for Dark Matter Search
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
L. Coelho,
E. Dahl,
L. DeViveiros,
A. Ferella,
L. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. -L. Giboni,
R. Gomez,
R. Hasty,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. McKinsey,
M. E. Monzani,
K. Ni,
U. Oberlack
, et al. (8 additional authors not shown)
Abstract:
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
△ Less
Submitted 26 September, 2006;
originally announced September 2006.
-
Performance and Fundamental Processes at Low Energy in a Two-Phase Liquid Xenon Dark Matter Detector
Authors:
T. Shutt,
C. E. Dahl,
J. Kwong,
A. Bolozdynya,
P. Brusov
Abstract:
We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated sum of charge and light signals and introduce the corresponding discrimination parameter, giving its mean value at 4 kV/cm for electron and nuclear recoils u…
▽ More
We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated sum of charge and light signals and introduce the corresponding discrimination parameter, giving its mean value at 4 kV/cm for electron and nuclear recoils up to 300 and 100 keV, respectively. We show that fluctuations in recombination limit discrimination for most energies, and reveal an improvement in discrimination below 20 keV due to a surprising increase in ionization yield for low energy electron recoils. This improvement is crucial for a high-sensitivity dark matter search.
△ Less
Submitted 29 September, 2006; v1 submitted 6 August, 2006;
originally announced August 2006.