-
Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
Authors:
M. Malnou,
J. A. B. Mates,
M. R. Vissers,
L. R. Vale,
D. R. Schmidt,
D. A. Bennett,
J. Gao,
J. N. Ullom
Abstract:
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodi…
▽ More
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Line Emission Mapper (LEM): Probing the physics of cosmic ecosystems
Authors:
Ralph Kraft,
Maxim Markevitch,
Caroline Kilbourne,
Joseph S. Adams,
Hiroki Akamatsu,
Mohammadreza Ayromlou,
Simon R. Bandler,
Marco Barbera,
Douglas A. Bennett,
Anil Bhardwaj,
Veronica Biffi,
Dennis Bodewits,
Akos Bogdan,
Massimiliano Bonamente,
Stefano Borgani,
Graziella Branduardi-Raymont,
Joel N. Bregman,
Joseph N. Burchett,
Jenna Cann,
Jenny Carter,
Priyanka Chakraborty,
Eugene Churazov,
Robert A. Crain,
Renata Cumbee,
Romeel Dave
, et al. (85 additional authors not shown)
Abstract:
The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe's structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM's main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole…
▽ More
The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe's structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM's main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. These processes are best studied in X-rays, and emission-line map** is the pressing need in this area. LEM will use a large microcalorimeter array/IFU, covering a 30x30' field with 10" angular resolution, to map the soft X-ray line emission from objects that constitute galactic ecosystems. These include supernova remnants, star-forming regions, superbubbles, galactic outflows (such as the Fermi/eROSITA bubbles in the Milky Way and their analogs in other galaxies), the Circumgalactic Medium in the Milky Way and other galaxies, and the Intergalactic Medium at the outskirts and beyond the confines of galaxies and clusters. LEM's 1-2 eV spectral resolution in the 0.2-2 keV band will make it possible to disentangle the faintest emission lines in those objects from the bright Milky Way foreground, providing groundbreaking measurements of the physics of these plasmas, from temperatures, densities, chemical composition to gas dynamics. While LEM's main focus is on galaxy formation, it will provide transformative capability for all classes of astrophysical objects, from the Earth's magnetosphere, planets and comets to the interstellar medium and X-ray binaries in nearby galaxies, AGN, and cooling gas in galaxy clusters. In addition to pointed observations, LEM will perform a shallow all-sky survey that will dramatically expand the discovery space.
△ Less
Submitted 12 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
Authors:
B. Dober,
Z. Ahmed,
K. Arnold,
D. T. Becker,
D. A. Bennett,
J. A. Connors,
A. Cukierman,
J. M. D'Ewart,
S. M. Duff,
J. E. Dusatko,
J. C. Frisch,
J. D. Gard,
S. W. Henderson,
R. Herbst,
G. C. Hilton,
J. Hubmayr,
Y. Li,
J. A. B. Mates,
H. McCarrick,
C. D Reintsema,
M. Silva-Feaver,
L. Ruckman,
J. N. Ullom,
L. R. Vale,
D. D. Van Winkle
, et al. (5 additional authors not shown)
Abstract:
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4…
▽ More
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.
△ Less
Submitted 19 January, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Authors:
Shawn W. Henderson,
Zeeshan Ahmed,
Jason Austermann,
Daniel Becker,
Douglas A. Bennett,
David Brown,
Saptarshi Chaudhuri,
Hsiao-Mei Sherry Cho,
John M. D'Ewart,
Bradley Dober,
Shannon M. Duff,
John E. Dusatko,
Sofia Fatigoni,
Josef C. Frisch,
Jonathon D. Gard,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Ethan D. Karpel,
Sarah S. Kernasovskiy,
Stephen E. Kuenstner,
Chao-Lin Kuo,
Dale Li,
John A. B. Mates
, et al. (7 additional authors not shown)
Abstract:
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per se…
▽ More
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to read out each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for several future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
Authors:
B. Dober,
D. T. Becker,
D. A. Bennett,
S. A. Bryan,
S. M. Duff,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
J. Hubmayr,
J. A. B. Mates,
C. D. Reintsema,
L. R. Vale,
J. N. Ullom
Abstract:
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, wh…
▽ More
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB map** on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $μ$MUX as a viable readout technique for future CMB imaging instruments.
△ Less
Submitted 15 December, 2017; v1 submitted 11 October, 2017;
originally announced October 2017.
-
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Authors:
Omid Noroozian,
John A. B. Mates,
Douglas A. Bennett,
Justus A. Brevik,
Joseph W. Fowler,
Jiansong Gao,
Gene C. Hilton,
Robert D. Horansky,
Kent D. Irwin,
Zhao Kang,
Daniel R. Schmidt,
Leila R. Vale,
Joel N. Ullom
Abstract:
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators co…
▽ More
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Filters for High Rate Pulse Processing
Authors:
B. K. Alpert,
R. D. Horansky,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
A. S. Hoover,
M. W. Rabin,
J. N. Ullom
Abstract:
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform,…
▽ More
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.
△ Less
Submitted 7 December, 2012;
originally announced December 2012.