-
Revealing unforeseen diagnostic image features with deep learning by detecting cardiovascular diseases from apical four-chamber ultrasounds
Authors:
Li-Hsin Cheng,
Pablo B. J. Bosch,
Rutger F. H. Hofman,
Timo B. Brakenhoff,
Eline F. Bruggemans,
Rob J. van der Geest,
Eduard R. Holman
Abstract:
Background. With the rise of highly portable, wireless, and low-cost ultrasound devices and automatic ultrasound acquisition techniques, an automated interpretation method requiring only a limited set of views as input could make preliminary cardiovascular disease diagnoses more accessible. In this study, we developed a deep learning (DL) method for automated detection of impaired left ventricular…
▽ More
Background. With the rise of highly portable, wireless, and low-cost ultrasound devices and automatic ultrasound acquisition techniques, an automated interpretation method requiring only a limited set of views as input could make preliminary cardiovascular disease diagnoses more accessible. In this study, we developed a deep learning (DL) method for automated detection of impaired left ventricular (LV) function and aortic valve (AV) regurgitation from apical four-chamber (A4C) ultrasound cineloops and investigated which anatomical structures or temporal frames provided the most relevant information for the DL model to enable disease classification.
Methods and Results. A4C ultrasounds were extracted from 3,554 echocardiograms of patients with either impaired LV function (n=928), AV regurgitation (n=738), or no significant abnormalities (n=1,888). Two convolutional neural networks (CNNs) were trained separately to classify the respective disease cases against normal cases. The overall classification accuracy of the impaired LV function detection model was 86%, and that of the AV regurgitation detection model was 83%. Feature importance analyses demonstrated that the LV myocardium and mitral valve were important for detecting impaired LV function, while the tip of the mitral valve anterior leaflet, during opening, was considered important for detecting AV regurgitation.
Conclusion. The proposed method demonstrated the feasibility of a 3D CNN approach in detection of impaired LV function and AV regurgitation using A4C ultrasound cineloops. The current research shows that DL methods can exploit large training data to detect diseases in a different way than conventionally agreed upon methods, and potentially reveal unforeseen diagnostic image features.
△ Less
Submitted 25 October, 2021;
originally announced October 2021.
-
Left Ventricle Segmentation via Optical-Flow-Net from Short-axis Cine MRI: Preserving the Temporal Coherence of Cardiac Motion
Authors:
Wenjun Yan,
Yuanyuan Wang,
Zeju Li,
Rob J. van der Geest,
Qian Tao
Abstract:
Quantitative assessment of left ventricle (LV) function from cine MRI has significant diagnostic and prognostic value for cardiovascular disease patients. The temporal movement of LV provides essential information on the contracting/relaxing pattern of heart, which is keenly evaluated by clinical experts in clinical practice. Inspired by the expert way of viewing Cine MRI, we propose a new CNN mod…
▽ More
Quantitative assessment of left ventricle (LV) function from cine MRI has significant diagnostic and prognostic value for cardiovascular disease patients. The temporal movement of LV provides essential information on the contracting/relaxing pattern of heart, which is keenly evaluated by clinical experts in clinical practice. Inspired by the expert way of viewing Cine MRI, we propose a new CNN module that is able to incorporate the temporal information into LV segmentation from cine MRI. In the proposed CNN, the optical flow (OF) between neighboring frames is integrated and aggregated at feature level, such that temporal coherence in cardiac motion can be taken into account during segmentation. The proposed module is integrated into the U-net architecture without need of additional training. Furthermore, dilated convolution is introduced to improve the spatial accuracy of segmentation. Trained and tested on the Cardiac Atlas database, the proposed network resulted in a Dice index of 95% and an average perpendicular distance of 0.9 pixels for the middle LV contour, significantly outperforming the original U-net that processes each frame individually. Notably, the proposed method improved the temporal coherence of LV segmentation results, especially at the LV apex and base where the cardiac motion is difficult to follow.
△ Less
Submitted 20 October, 2018;
originally announced October 2018.
-
Dynamic vortical flow profile quantitatively characterizes mitral valvular-left ventricular hemodynamic coupling: In vivo analysis by dynamic 3D enstrophy map** from 4D Flow MRI
Authors:
Mohammed S. M. Elbaz,
Trung Bao Le,
Pankaj Garg,
Arno A. W. Roest,
Boudewijn P. F. Lelieveldt,
Sven Plein,
Jos J. M. Westenberg,
Fotis Sotiropoulos,
Rob J. van der Geest
Abstract:
Vortical blood flow in the human left ventricular (LV) inflow initiates from the mitral valve (MV) and evolves within the LV during diastolic E-filling. Hence, vortical flow links MV and LV hemodynamics. This study sought to elucidate and quantitatively characterize the in vivo 3D dynamics of LV vortical flow over E-filling and relation to MV-LV hemodynamic coupling using 4D Flow MRI flow field. 3…
▽ More
Vortical blood flow in the human left ventricular (LV) inflow initiates from the mitral valve (MV) and evolves within the LV during diastolic E-filling. Hence, vortical flow links MV and LV hemodynamics. This study sought to elucidate and quantitatively characterize the in vivo 3D dynamics of LV vortical flow over E-filling and relation to MV-LV hemodynamic coupling using 4D Flow MRI flow field. 34 healthy volunteers and 5 example patients underwent 4D Flow MRI. Vortical blood flow evolution was mapped in the LV over E-wave using enstrophy density. A new dimensionless profile PMV-LV was derived as a function of both MV vortex formation time (VFT) and LV volumetric enstrophy density. Results reveal that 3D vortical flow evolution in the healthy LV follows a bi-phasic behavior with a vortical growth phase followed by a vortical decay phase. In healthy LVs studied, the PMV-LV profile showed that the vortical growth and decay phases are characterized by a vortical growth time T_growth= 1.23+/-0.25, growth rate α=0.80+/-0.17, decay time T_decay= 0.96+/-0.39 and decay rate \b{eta}=-1.02+/-0.49. Distinctly altered parameters were found in the pilot patients studied. The derived PMV-LV profile quantitatively characterizes MV-LV hemodynamic coupling by vortical flow dynamics. Results herein unravel new insights into cardiac physiology and could enable a novel standardized methodology to study MV-LV hemodynamic coupling and association to cardiac function in health and disease.
△ Less
Submitted 10 October, 2018; v1 submitted 10 October, 2018;
originally announced October 2018.
-
Fully Automated Left Atrium Cavity Segmentation from 3D GE-MRI by Multi-Atlas Selection and Registration
Authors:
Mengyun Qiao,
Yuanyuan Wang,
Rob J. van der Geest,
Qian Tao
Abstract:
This paper presents a fully automated method to segment the complex left atrial (LA) cavity, from 3D Gadolinium-enhanced magnetic resonance imaging (GE-MRI) scans. The proposed method consists of four steps: (1) preprocessing to convert the original GE-MRI to a probability map, (2) atlas selection to match the atlases to the target image, (3) multi-atlas registration and fusion, and (4) level-set…
▽ More
This paper presents a fully automated method to segment the complex left atrial (LA) cavity, from 3D Gadolinium-enhanced magnetic resonance imaging (GE-MRI) scans. The proposed method consists of four steps: (1) preprocessing to convert the original GE-MRI to a probability map, (2) atlas selection to match the atlases to the target image, (3) multi-atlas registration and fusion, and (4) level-set refinement. The method was evaluated on the datasets provided by the MICCAI 2018 STACOM Challenge with 100 dataset for training. Compared to manual annotation, the proposed method achieved an average Dice overlap index of 0.88.
△ Less
Submitted 10 October, 2018;
originally announced October 2018.