Skip to main content

Showing 1–10 of 10 results for author: van Bibber, K A

.
  1. arXiv:1809.02246  [pdf, other

    physics.ins-det

    Characterization of the HAYSTAC axion dark matter search cavity using microwave measurement and simulation techniques

    Authors: Nicholas M. Rapidis, Samantha M. Lewis, Karl A. van Bibber

    Abstract: Many searches for axion cold dark matter rely on the use of tunable electromagnetic resonators. Current detectors operate at or near microwave frequencies and use cylindrical cavities with cylindrical tuning rods. The cavity performance strongly impacts the signal power of the detector, which is expected to be very small even under optimal conditions. There is strong motivation to characterize the… ▽ More

    Submitted 30 January, 2019; v1 submitted 6 September, 2018; originally announced September 2018.

    Comments: 22 pages, 8 figures The following article has been submitted to Review of Scientific Instruments. v2: added changes made during the review process

  2. arXiv:1803.03690  [pdf, other

    hep-ex physics.ins-det

    Results from phase 1 of the HAYSTAC microwave cavity axion experiment

    Authors: L. Zhong, S. Al Kenany, K. M. Backes, B. M. Brubaker, S. B. Cahn, G. Carosi, Y. V. Gurevich, W. F. Kindel, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, R. H. Maruyama, D. A. Palken, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, D. H. Speller, I. Urdinaran, K. A. van Bibber

    Abstract: We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range… ▽ More

    Submitted 9 March, 2018; originally announced March 2018.

    Journal ref: Phys. Rev. D 97, 092001 (2018)

  3. arXiv:1706.08388  [pdf, other

    astro-ph.IM hep-ex

    The HAYSTAC Axion Search Analysis Procedure

    Authors: B. M. Brubaker, L. Zhong, S. K. Lamoreaux, K. W. Lehnert, K. A. van Bibber

    Abstract: We describe in detail the analysis procedure used to derive the first limits from the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a microwave cavity search for cold dark matter (CDM) axions with masses above $20\ μ\text{eV}$. We have introduced several significant innovations to the axion search analysis pioneered by the Axion Dark Matter eXperiment (ADMX), including optimal filtering of t… ▽ More

    Submitted 22 December, 2017; v1 submitted 26 June, 2017; originally announced June 2017.

    Comments: 33 pages, 10 figures; added changes made in review process

    Journal ref: Phys. Rev. D 96, 123008 (2017)

  4. arXiv:1611.07123  [pdf, other

    physics.ins-det astro-ph.IM

    Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range

    Authors: S. Al Kenany, M. A. Anil, K. M. Backes, B. M. Brubaker, S. B. Cahn, G. Carosi, Y. V. Gurevich, W. F. Kindel, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, D. A. Palken, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, I. Urdinaran, K. A. van Bibber, L. Zhong

    Abstract: We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple… ▽ More

    Submitted 22 February, 2017; v1 submitted 21 November, 2016; originally announced November 2016.

    Comments: 17 pages, published in NIM A. v2: added changes made during the review process

  5. arXiv:1610.02580  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex

    First results from a microwave cavity axion search at 24 micro-eV

    Authors: B. M. Brubaker, L. Zhong, Y. V. Gurevich, S. B. Cahn, S. K. Lamoreaux, M. Simanovskaia, J. R. Root, S. M. Lewis, S. Al Kenany, K. M. Backes, I. Urdinaran, N. M. Rapidis, T. M. Shokair, K. A. van Bibber, D. A. Palken, M. Malnou, W. F. Kindel, M. A. Anil, K. W. Lehnert, G. Carosi

    Abstract: We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde… ▽ More

    Submitted 9 February, 2017; v1 submitted 8 October, 2016; originally announced October 2016.

    Comments: 5 pages, 3 figures, accepted for publication in PRL. v2: added changes made during the review process

    Journal ref: Phys. Rev. Lett. 118, 061302 (2017)

  6. arXiv:1602.00039  [pdf, other

    hep-ex astro-ph.CO hep-ph

    Experimental Searches for the Axion and Axion-like Particles

    Authors: Peter W. Graham, Igor G. Irastorza, Steven K. Lamoreaux, Axel Lindner, Karl A. van Bibber

    Abstract: Four decades after its prediction, the axion remains the most compelling solution to the Strong-CP problem and a well-motivated dark matter candidate, inspiring a host of elegant and ultrasensitive experiments based on axion-photon mixing. This report reviews the experimental situation on several fronts. The microwave cavity experiment is making excellent progress in the search for dark matter axi… ▽ More

    Submitted 29 January, 2016; originally announced February 2016.

    Comments: Published in Annual Review of Nuclear and Particle Science Vol. 65 (2015). 31 pages, 14 figures. Posted with permission from the Annual Review of Nuclear and Particle Science, Volume 65. copyright 2015 by Annual Reviews, http://www.annualreviews.org

    Journal ref: Annual Review of Nuclear and Particle Science, Vol. 65: 485-514 (2015)

  7. arXiv:1502.01132  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos

    Authors: M. Askins, M. Bergevin, A. Bernstein, S. Dazeley, S. T. Dye, T. Handler, A. Hatzikoutelis, D. Hellfeld, P. Jaffke, Y. Kamyshkov, B. J. Land, J. G. Learned, P. Marleau, C. Mauger, G. D. Orebi Gann, C. Roecker, S. D. Rountree, T. M. Shokair, M. B. Smy, R. Svoboda, M. Sweany, M. R. Vagins, K. A. van Bibber, R. B. Vogelaar, M. J. Wetstein , et al. (1 additional authors not shown)

    Abstract: This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational stat… ▽ More

    Submitted 4 February, 2015; originally announced February 2015.

    Comments: 35 pages, 9 figures

  8. arXiv:1409.5864  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Advanced Scintillator Detector Concept (ASDC): A Concept Paper on the Physics Potential of Water-Based Liquid Scintillator

    Authors: J. R. Alonso, N. Barros, M. Bergevin, A. Bernstein, L. Bignell, E. Blucher, F. Calaprice, J. M. Conrad, F. B. Descamps, M. V. Diwan, D. A. Dwyer, S. T. Dye, A. Elagin, P. Feng, C. Grant, S. Grullon, S. Hans, D. E. Jaffe, S. H. Kettell, J. R. Klein, K. Lande, J. G. Learned, K. B. Luk, J. Maricic, P. Marleau , et al. (25 additional authors not shown)

    Abstract: The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would include determination of the neutrino mass hierarchy and observation of CP violation with long-baseline neutrino… ▽ More

    Submitted 24 October, 2014; v1 submitted 20 September, 2014; originally announced September 2014.

    Report number: BNL-106082-2014-JA

  9. arXiv:1405.3685  [pdf, other

    physics.ins-det hep-ex

    Future Directions in the Microwave Cavity Search for Dark Matter Axions

    Authors: T. M. Shokair, J. Root, K. A. Van Bibber, B. Brubaker, Y. V. Gurevich, S. B. Cahn, S. K. Lamoreaux, M. A. Anil, K. W. Lehnert, B. K. Mitchell, A. Reed, G. Carosi

    Abstract: The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrate… ▽ More

    Submitted 14 May, 2014; originally announced May 2014.

  10. arXiv:1306.3591  [pdf, ps, other

    physics.ins-det hep-ex quant-ph

    Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches

    Authors: S. K. Lamoreaux, K. A. van Bibber, K. W. Lehnert, G. Carosi

    Abstract: We show that at higher frequencies, and thus higher axion masses, single-photon detectors become competitive and ultimately favored, when compared to quantum-limited linear amplifiers, as the detector technology in microwave cavity experimental searches for galactic halo dark matter axions. The cross-over point in this comparison is of order 10 GHz ($\sim 40\ μ$eV), not far above the frequencies o… ▽ More

    Submitted 3 August, 2013; v1 submitted 15 June, 2013; originally announced June 2013.

    Comments: 5 pages, 1 figure new version address comments received