Sensitivity-Based Distributed Model Predictive Control for Nonlinear Systems under Inexact Optimization
Authors:
Maximilian Pierer von Esch,
Andreas Völz,
Knut Graichen
Abstract:
This paper presents a distributed model predictive control (DMPC) scheme for nonlinear continuous-time systems. The underlying distributed optimal control problem is cooperatively solved in parallel via a sensitivity-based algorithm. The algorithm is fully distributed in the sense that only one neighbor-to-neighbor communication step per iteration is necessary and that all computations are perform…
▽ More
This paper presents a distributed model predictive control (DMPC) scheme for nonlinear continuous-time systems. The underlying distributed optimal control problem is cooperatively solved in parallel via a sensitivity-based algorithm. The algorithm is fully distributed in the sense that only one neighbor-to-neighbor communication step per iteration is necessary and that all computations are performed locally. Sufficient conditions are derived for the algorithm to converge towards the central solution. Based on this result, stability is shown for the suboptimal DMPC scheme under inexact minimization with the sensitivity-based algorithm and verified with numerical simulations. In particular, stability can be guaranteed with either a suitable stop** criterion or a fixed number of algorithm iterations in each MPC sampling step which allows for a real-time capable implementation.
△ Less
Submitted 5 June, 2024;
originally announced June 2024.
-
R&D around a photoneutralizer-based NBI system (Siphore) in view of a DEMO Tokamak steady state fusion reactor
Authors:
A. Simonin,
Jocelyn Achard,
K. Achkasov,
S. Béchu,
C. Baudouin,
O. Baulaigue,
C. Blondel,
J. P. Boeuf,
Gilles Cartry,
W. Chaibi,
C. Drag,
H. P. L. de Esch,
D. Fiorucci,
G. Fubiani,
I. Furno,
R. Futtersack,
P. Garibaldi,
A. Gicquel,
C. Grand,
Ph Guittienne,
G. Hagelaar,
A. Howling,
R. Jacquier,
M. J. Kirkpatrick,
D. Lemoine
, et al. (6 additional authors not shown)
Abstract:
Since the signature of the ITER treaty in 2006, a new research programme targeting the emergence of a new generation of Neutral Beam (NB) system for the future fusion reactor (DEMO Tokamak) has been underway between several laboratories in Europe. The specifications required to operate a NB system on DEMO are very demanding: the system has to provide plasma heating, current drive and plasma contro…
▽ More
Since the signature of the ITER treaty in 2006, a new research programme targeting the emergence of a new generation of Neutral Beam (NB) system for the future fusion reactor (DEMO Tokamak) has been underway between several laboratories in Europe. The specifications required to operate a NB system on DEMO are very demanding: the system has to provide plasma heating, current drive and plasma control at a very high level of power (up to 150 MW) and energy (1 or 2 MeV), including high performances in term of wall-plug efficiency ($η$ > 60%), high availability and reliability. To this aim, a novel NB concept based on the photodetachment of the energetic negative ion beam is under study. The keystone of this new concept is the achievement of a photoneutralizer where a high power photon flux (~3 MW) generated within a Fabry Perot cavity will overlap, cross and partially photodetach the intense negative ion beam accelerated at high energy (1 or 2 MeV). The aspect ratio of the beam-line (source, accelerator, etc.) is specifically designed to maximize the overlap of the photon beam with the ion beam. It is shown that such a photoneutralized based NB system would have the capability to provide several tens of MW of D 0 per beam line with a wall-plug efficiency higher than 60%. A feasibility study of the concept has been launched between different laboratories to address the different physics aspects, i.e., negative ion source, plasma modelling, ion accelerator simulation, photoneutralization and high voltage holding under vacuum. The paper describes the present status of the project and the main achievements of the developments in laboratories.
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
The ALMA Spectroscopic Survey in the HUDF: CO emission lines and 3 mm continuum sources
Authors:
Jorge González-López,
Roberto Decarli,
Ricardo Pavesi,
Fabian Walter,
Manuel Aravena,
Chris Carilli,
Leindert Boogaard,
Gergö Pop**,
Axel Weiss,
Roberto J. Assef,
Franz Erik Bauer,
Frank Bertoldi,
Richard Bouwens,
Thierry Contini,
Paulo C. Cortes,
Pierre Cox,
Elisabete da Cunha,
Emanuele Daddi,
Tanio Díaz-Santos,
Hanae Inami,
Jacqueline Hodge,
Rob Ivison,
Olivier Le Fèvre,
Benjamin Magnelli,
Pascal esch
, et al. (7 additional authors not shown)
Abstract:
The ALMA SPECtroscopic Survey in the {\it Hubble} Ultra Deep Field is an ALMA large program that obtained a frequency scan in the 3\,mm band to detect emission lines from the molecular gas in distant galaxies. We here present our search strategy for emission lines and continuum sources in the HUDF. We compare several line search algorithms used in the literature, and critically account for the lin…
▽ More
The ALMA SPECtroscopic Survey in the {\it Hubble} Ultra Deep Field is an ALMA large program that obtained a frequency scan in the 3\,mm band to detect emission lines from the molecular gas in distant galaxies. We here present our search strategy for emission lines and continuum sources in the HUDF. We compare several line search algorithms used in the literature, and critically account for the line-widths of the emission line candidates when assessing significance. We identify sixteen emission lines at high fidelity in our search. Comparing these sources to multi-wavelength data we find that all sources have optical/infrared counterparts. Our search also recovers candidates that have lower significance that can be used statistically to derive, e.g. the CO luminosity function. We apply the same detection algorithm to obtain a sample of six 3 mm continuum sources. All of these are also detected in the 1.2 mm continuum with optical/near-infrared counterparts. We use the continuum sources to compute 3 mm number counts in the sub-mJy regime, and find them to be higher by an order of magnitude than expected for synchrotron-dominated sources. However, the number counts are consistent with those derived at shorter wavelengths (0.85--1.3\,mm) once extrapolating to 3\,mm with a dust emissivity index of $β=1.5$, dust temperature of 35\,K and an average redshift of $z=2.5$. These results represent the best constraints to date on the faint end of the 3 mm number counts.
△ Less
Submitted 21 March, 2019;
originally announced March 2019.
-
Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
Authors:
M. Anastasopoulos,
R. Bebb,
K. Berry,
J. Birch,
T. Bryś,
J. -C. Buffet,
J. -F. Clergeau,
P. P. Deen,
G. Ehlers,
P. van Esch,
S. M. Everett,
B. Guerard,
R. Hall-Wilton,
K. Herwig,
L. Hultman,
C. Höglund,
I. Iruretagoiena,
F. Issa,
J. Jensen,
A. Khaplanov,
O. Kirstein,
I. Lopez-Higuera,
F. Piscitelli,
L. Robinson,
S. Schmidt
, et al. (1 additional authors not shown)
Abstract:
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demo…
▽ More
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
△ Less
Submitted 3 April, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors
Authors:
F. Piscitelli,
A. Khaplanov,
A. Devishvili,
S. Schmidt,
C. Höglund,
J. Birch,
A. J. C. Dennison,
P. Gutfreund,
R. Hall-Wilton,
P. Van Esch
Abstract:
Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In the case of strongly absorbing nuclei the number of neutrons is not conserved and the absorption can be directly measured by using the neutron-induced fluoresce…
▽ More
Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In the case of strongly absorbing nuclei the number of neutrons is not conserved and the absorption can be directly measured by using the neutron-induced fluorescence technique which exploits the prompt particle emission of absorbing isotopes. This technique is emerging from soft matter and biology where highly absorbing nuclei, generally in very small quantities, are used as a label for buried layers. Nowadays the importance of highly absorbing layers is rapidly increasing, partially because of their application in neutron detection; a field that has become more and more active also due to the 3He-shortage. In this manuscript we extend the neutron-induced fluorescence technique to the study of thick layers of highly absorbing materials; in particular 10B4C. The theory of neutron reflectometry is a commonly studied topic, however the subtle relationship between the reflection and the absorption of neutrons is not widely known, in particular when a strong absorption is present. The theory for a general stack of absorbing layers has been developed and compared to measurements. This new technique has potential as a tool for characterization of highly absorbing layers. We also report on the requirements that a 10B4C layer must fulfill in order to be employed as a converter in neutron detection.
△ Less
Submitted 5 October, 2015;
originally announced October 2015.
-
Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
Authors:
J. Birch,
J. -C. Buffet,
J. -F. Clergeau,
P. van Esch,
M. Ferraton,
B. Guerard,
R. Hall-Wilton,
L. Hultman,
C. Höglund,
J. Jensen,
A. Khaplanov,
F. Piscitelli
Abstract:
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of…
▽ More
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of of the Multi-Grid detector and other similar concepts due to its mechanical and neutronic properties. Due to natural concentration of $α$ emitters, however, the background from $α$ particles misidentified as neutrons can be unacceptably high. We present our experience operating a detector prototype affected by this issue. Monte Carlo simulations have been used to confirm the background as $α$ particles. The issues have been addressed in the more recent implementations of the Multi-Grid detector by the use of purified aluminium as well as Ni-plating of standard aluminium. The result is the reduction in background by two orders of magnitude. A new large-area prototype has been built incorporating these modifications.
△ Less
Submitted 16 September, 2015; v1 submitted 2 July, 2015;
originally announced July 2015.
-
Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype
Authors:
F. Piscitelli,
J. C. Buffet,
J. F. Clergeau,
S. Cuccaro,
B. Guerard,
A. Khaplanov,
Q. La Manna,
J. M. Rigal,
P. Van Esch
Abstract:
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Lau…
▽ More
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade detector which wants to increase the spatial resolution of 3He-based detectors for high flux applications. We developed a high spatial resolution prototype suitable for neutron reflectometry instruments. It exploits solid 10B-films employed in a proportional gas chamber. Two prototypes have been constructed at ILL and the results obtained on our monochromatic test beam line are presented here.
△ Less
Submitted 9 December, 2013;
originally announced December 2013.
-
An Information-Theoretical Approach to Image Resolution Applied to Neutron Imaging Detectors based upon Individual Discriminator Signals
Authors:
Jean-François Clergeau,
Matthieu Ferraton,
Bruno Guérard,
Anton Khaplanov,
Francesco Piscitelli,
Martin Platz,
Jean-Marie Rigal,
Patrick Van Esch,
Thibault Daullé
Abstract:
1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlap** in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-li…
▽ More
1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlap** in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-like spots of neutron impacts with a given distance between them act as a source of information (each neutron hit belongs to one spot or the other), and the detector plus signal treatment is regarded as an imperfect communication channel that transmits this information. The maximal mutual information obtained from this channel as a function of the distance between the spots allows to define a calibration-independent measure of resolution. We then apply this measure to quantify the power of resolution of different algorithms treating these individual discriminator signals which can be implemented in firmware. The method is then applied to different detectors existing at the ILL. Center-of-gravity methods usually improve the resolution over best-wire algorithms which are the standard way of treating these signals.
△ Less
Submitted 29 July, 2013;
originally announced July 2013.
-
Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
Authors:
Anton Khaplanov,
Francesco Piscitelli,
Jean-Claude Buffet,
Jean-Francois Clergeau,
Jonathan Correa,
Patrick van Esch,
Mathieu Ferraton,
Bruno Guerard,
Richard Hall-Wilton
Abstract:
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to…
▽ More
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.
△ Less
Submitted 26 June, 2013;
originally announced June 2013.
-
Analytical modeling of thin film neutron converters and its application to thermal neutron gas detectors
Authors:
Francesco Piscitelli,
Patrick Van Esch
Abstract:
A simple model is explored mainly analytically to calculate and understand the PHS of single and multi-layer thermal neutron detectors and to help optimize the design in different circumstances. Several theorems are deduced that can help guide the design.
A simple model is explored mainly analytically to calculate and understand the PHS of single and multi-layer thermal neutron detectors and to help optimize the design in different circumstances. Several theorems are deduced that can help guide the design.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Multi-Grid Boron-10 detector for large area applications in neutron scattering science
Authors:
Ken Andersen,
Thierry Bigault,
Jens Birch,
Jean-Claude Buffet,
Jonathan Correa,
Patrick van Esch,
Bruno Guerard,
Richard Hall-Wilton,
Lars Hultman,
Carina Höglund,
Jens Jensen,
Anton Khaplanov,
Oliver Kirstein,
Francesco Piscitelli,
Christian Vettier
Abstract:
The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of cutting-edge instrumentation for neutron scattering science. In this context, 10B-based detectors are being developed by collaboration between the ESS, ILL, and…
▽ More
The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of cutting-edge instrumentation for neutron scattering science. In this context, 10B-based detectors are being developed by collaboration between the ESS, ILL, and Linkö** University. This paper reports on progress of this technology and the prospects applying it in modern neutron scattering experiments. The detector is made-up of multiple rectangular gas counter tubes coated with B4C, enriched in 10B. An anode wire reads out each tube, thereby giving position of conversion in one of the lateral co-ordinates as well as in depth of the detector. Position resolution in the remaining co-ordinate is obtained by segmenting the cathode tube itself. Boron carbide films have been produced at Linkö** University and a detector built at ILL. The characterization study is presented in this paper, including measurement of efficiency, effects of the fill gas species and pressure, coating thickness variation on efficiency and sensitivity to gamma-rays.
△ Less
Submitted 4 September, 2012;
originally announced September 2012.
-
Multiple hits in wire chambers and other particle detectors
Authors:
Patrick Van Esch
Abstract:
We propose an analysis of the dead time losses in counting imaging detectors such as MWPC which can resolve $k$ simultaneous hits, and analyze in more detail an $X-Y$ detector which has a third wire set which allows for the recognition of simultaneous impacts.
We propose an analysis of the dead time losses in counting imaging detectors such as MWPC which can resolve $k$ simultaneous hits, and analyze in more detail an $X-Y$ detector which has a third wire set which allows for the recognition of simultaneous impacts.
△ Less
Submitted 8 June, 2007;
originally announced June 2007.
-
Effects of ion drift on time-over-threshold charge estimates using first-order integrators in thermal neutron MWPC
Authors:
Patrick Van Esch,
Thomas Durand
Abstract:
Time-over-threshold measurements of the output of a first order integration amplifier can be used as a cheap way to estimate the charge deposited on a wire in an MWPC. Even if the time scale of the first order system is seemingly much larger than the signal development time, we noticed experimentally a significant deviation from the relationship of time-over-threshold and the charge, as would be…
▽ More
Time-over-threshold measurements of the output of a first order integration amplifier can be used as a cheap way to estimate the charge deposited on a wire in an MWPC. Even if the time scale of the first order system is seemingly much larger than the signal development time, we noticed experimentally a significant deviation from the relationship of time-over-threshold and the charge, as would be naively expected from the exponential response of the amplifier. We strongly suspect the current induced by the residual ion movement to be at least partially responsible for this observation. It is of course well-known that the ion movement is responsible for the bulk of the signal generation in a wire chamber, this is not the point ; however, the surprise is rather that this movement has influences on time scales which are so long that the finite ion movement could be thought negligible. In this paper we will treat theoretically the influence of ion movement and of AC coupling on the expected time-over-threshold relationship and confront this to the measurements on a small test MWPC in thermal neutron detection.
△ Less
Submitted 3 November, 2006;
originally announced November 2006.
-
An Electrostatic Lens to Reduce Parallax in Banana Gas Detectors
Authors:
Patrick Van Esch,
Jean-Francois Clergeau,
Kadda Medjoubi
Abstract:
Cylindrical "banana" gas detectors are often used in fixed-target experiments, because they are free of parallax effects in the equatorial plane. However, there is a growing demand to increase the height of these detectors in order to be more efficient or to cover more solid angle, and hence a parallax effect starts to limit the resolution in that direction. In this paper we propose a hardware c…
▽ More
Cylindrical "banana" gas detectors are often used in fixed-target experiments, because they are free of parallax effects in the equatorial plane. However, there is a growing demand to increase the height of these detectors in order to be more efficient or to cover more solid angle, and hence a parallax effect starts to limit the resolution in that direction. In this paper we propose a hardware correction for this problem which reduces the parallax error thanks to an applied potential on the front window that makes the electrostatic field lines radially pointing to the interaction point at the entrance window. A detailed analytical analysis of the solution is also presented.
△ Less
Submitted 4 August, 2006;
originally announced August 2006.
-
An Optimal Lookup Table Construction for Charge Division with respect to Efficiency Flatness
Authors:
Patrick Van Esch,
Frederic Millier
Abstract:
Static lookup tables as often used in the position calculation electronics in position sensitive detectors suffer from the well known problem that the propagation of digitization errors in the division leads to unequal efficiencies for the different output channels. In this paper we present a solution to the construction of such a lookup table which is optimal in the sense that the least possibl…
▽ More
Static lookup tables as often used in the position calculation electronics in position sensitive detectors suffer from the well known problem that the propagation of digitization errors in the division leads to unequal efficiencies for the different output channels. In this paper we present a solution to the construction of such a lookup table which is optimal in the sense that the least possible efficiency errors are committed in the class of monotone lookup tables. The obtained resolution is comparable to what is obtained using the standard implementation of the fixed point division. After a theoretical explanation, we present some experimental results confirming our claim.
△ Less
Submitted 4 August, 2006;
originally announced August 2006.
-
Off line Parallax Correction for Neutral Particle Gas Detectors
Authors:
Patrick Van Esch
Abstract:
In a neutral particle gas detector, the parallax error resulting from the perpendicular projection on the detection plane or wire of the radial particle trajectories emanating from a point like source (such as a scattering sample) can significantly spoil the apparent angular resolution of the detector. However, as we will show, the information is not lost. We propose an off line data treatment t…
▽ More
In a neutral particle gas detector, the parallax error resulting from the perpendicular projection on the detection plane or wire of the radial particle trajectories emanating from a point like source (such as a scattering sample) can significantly spoil the apparent angular resolution of the detector. However, as we will show, the information is not lost. We propose an off line data treatment to restore as much as possible the original scattering information in the case of a one-dimensional parallax effect. The reversibility of parallax follows from the algebraic structure of this effect, which is different from the resolution loss which is essentially irreversible. The interplay between finite resolution and parallax complicates the issue, but this can be resolved.
△ Less
Submitted 4 August, 2006;
originally announced August 2006.
-
Design guide for electronics for resistive charge division in thermal neutron detection
Authors:
Patrick Van Esch,
Thomas Gahl,
Bruno Guerard
Abstract:
An amplifier has been designed for optimal use of position sensitive thermal neutron detectors using the principle of resistive charge division. The important points in this optimization are: high counting rates and good spatial resolution. This amplifier is built as a hybrid circuit and is now used on several new instruments at the ILL. It consists of a fast low noise current pre-amplifier, a g…
▽ More
An amplifier has been designed for optimal use of position sensitive thermal neutron detectors using the principle of resistive charge division. The important points in this optimization are: high counting rates and good spatial resolution. This amplifier is built as a hybrid circuit and is now used on several new instruments at the ILL. It consists of a fast low noise current pre-amplifier, a gaussian sha** circuit based on a 4th order active filter and an essentially noiseless baseline reconstruction. In this paper, we present a rather complete theoretical analysis of the problem that lead us to the choices made above, and allows for an optimal adaptation to other situations. An analysis of unwanted, secondary effects is also worked out.
△ Less
Submitted 4 August, 2006;
originally announced August 2006.
-
Capacity formulas in MWPC: some critical reflexions
Authors:
Patrick Van Esch
Abstract:
An approximate analytical expression for "capacitance" of MWPC configurations circulates in the literature since decades and is copied over and over again. In this paper we will try to show that this formula corresponds to a physical quantity that is different from what it is usually thought to stand for.
An approximate analytical expression for "capacitance" of MWPC configurations circulates in the literature since decades and is copied over and over again. In this paper we will try to show that this formula corresponds to a physical quantity that is different from what it is usually thought to stand for.
△ Less
Submitted 2 August, 2006;
originally announced August 2006.
-
On the Everett programme and the Born rule
Authors:
Patrick Van Esch
Abstract:
Proponents of the Everett interpretation of Quantum Theory have made efforts to show that to an observer in a branch, everything happens as if the projection postulate were true without postulating it. In this paper, we will indicate that it is only possible to deduce this rule if one introduces another postulate that is logically equivalent to introducing the projection postulate as an extra as…
▽ More
Proponents of the Everett interpretation of Quantum Theory have made efforts to show that to an observer in a branch, everything happens as if the projection postulate were true without postulating it. In this paper, we will indicate that it is only possible to deduce this rule if one introduces another postulate that is logically equivalent to introducing the projection postulate as an extra assumption. We do this by examining the consequences of changing the projection postulate into an alternative one, while kee** the unitary part of quantum theory, and indicate that this is a consistent (although strange) physical theory.
△ Less
Submitted 9 May, 2005;
originally announced May 2005.
-
The H1 Forward Proton Spectrometer at HERA
Authors:
P. van Esch,
M. Kapichine,
A. Morozov,
V. Spaskov,
W. Bartel,
B. List,
H. Mahlke-Krueger,
V. Schroeder,
T. Wilksen,
F. W. Buesser,
K. Geske,
O. Karschnik,
F. Niebergall,
H. Riege,
J. Schuett,
R. van Staa,
C. Wittek,
D. Dau,
D. Newton,
S. K. Kotelnikov,
A. Lebedev,
S. Rusakov,
A. Astvatsatourov,
J. Baehr,
U. Harder
, et al. (4 additional authors not shown)
Abstract:
The forward proton spectrometer is part of the H1 detector at the HERA collider. Protons with energies above 500 GeV and polar angles below 1 mrad can be detected by this spectrometer. The main detector components are scintillating fiber detectors read out by position-sensitive photo-multipliers. These detectors are housed in so-called Roman Pots which allow them to be moved close to the circula…
▽ More
The forward proton spectrometer is part of the H1 detector at the HERA collider. Protons with energies above 500 GeV and polar angles below 1 mrad can be detected by this spectrometer. The main detector components are scintillating fiber detectors read out by position-sensitive photo-multipliers. These detectors are housed in so-called Roman Pots which allow them to be moved close to the circulating proton beam. Four Roman Pot stations are located at distances between 60 m and 90 m from the interaction point.
△ Less
Submitted 20 January, 2000;
originally announced January 2000.