-
Experiment Segmentation in Scientific Discourse as Clause-level Structured Prediction using Recurrent Neural Networks
Authors:
Pradeep Dasigi,
Gully A. P. C. Burns,
Eduard Hovy,
Anita de Waard
Abstract:
We propose a deep learning model for identifying structure within experiment narratives in scientific literature. We take a sequence labeling approach to this problem, and label clauses within experiment narratives to identify the different parts of the experiment. Our dataset consists of paragraphs taken from open access PubMed papers labeled with rhetorical information as a result of our pilot a…
▽ More
We propose a deep learning model for identifying structure within experiment narratives in scientific literature. We take a sequence labeling approach to this problem, and label clauses within experiment narratives to identify the different parts of the experiment. Our dataset consists of paragraphs taken from open access PubMed papers labeled with rhetorical information as a result of our pilot annotation. Our model is a Recurrent Neural Network (RNN) with Long Short-Term Memory (LSTM) cells that labels clauses. The clause representations are computed by combining word representations using a novel attention mechanism that involves a separate RNN. We compare this model against LSTMs where the input layer has simple or no attention and a feature rich CRF model. Furthermore, we describe how our work could be useful for information extraction from scientific literature.
△ Less
Submitted 17 February, 2017;
originally announced February 2017.
-
Insertable system for fast turnaround time microwave experiments in a dilution refrigerator
Authors:
Florian R. Ong,
Jean-Luc Orgiazzi,
Arlette de Waard,
Giorgio Frossati,
Adrian Lupascu
Abstract:
Microwave experiments in dilution refrigerators are a central tool in the field of superconducting quantum circuits and other research areas. This type of experiments relied so far on attaching a device to the mixing chamber of a dilution refrigerator. The minimum turnaround time in this case is a few days as required by cooling down and warming up the entire refrigerator. We developed a new appro…
▽ More
Microwave experiments in dilution refrigerators are a central tool in the field of superconducting quantum circuits and other research areas. This type of experiments relied so far on attaching a device to the mixing chamber of a dilution refrigerator. The minimum turnaround time in this case is a few days as required by cooling down and warming up the entire refrigerator. We developed a new approach, in which a suitable sample holder is attached to a cold-insertable probe and brought in contact with transmission lines permanently mounted inside the cryostat. The total turnaround time is 8 hours if the target temperature is 80 mK. The lowest attainable temperature is 30 mK. Our system can accommodate up to six transmission lines, with a measurement bandwidth tested between DC and 12 GHz. This bandwidth is limited by low pass components in the setup; we expect the intrinsic bandwidth to be at least 18 GHz. We present our setup, discuss the experimental procedure, and give examples of experiments enabled by this system. This new measurement method will have a major impact on systematic ultra-low temperature studies using microwave signals, including those requiring quantum coherence.
△ Less
Submitted 5 September, 2012;
originally announced September 2012.
-
CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background
Authors:
F. Alessandria,
E. Andreotti,
R. Ardito,
C. Arnaboldi,
F. T. Avignone III,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
A. Bryant,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Chott,
M. Clemenza
, et al. (94 additional authors not shown)
Abstract:
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been…
▽ More
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed.
△ Less
Submitted 5 September, 2011; v1 submitted 24 August, 2011;
originally announced August 2011.
-
Results from a search for the $0νββ$-decay of $^{130}Te$
Authors:
C. Arnaboldi,
D. R. Artusa,
F. T. Avignone III,
M. Balata,
I. Bandac,
M. Barucci,
J. W. Beeman,
F. Bellini,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Carbone,
S. Cebrian,
M. Clemenza,
O. Cremonesi,
R. J. Creswick,
A. de Waard,
S. Di Domizio,
M. J. Dolinski,
H. A. Farach,
E. Fiorini,
G. Frossati,
A. Giachero,
A. Giuliani,
P. Gorla
, et al. (26 additional authors not shown)
Abstract:
A detailed description of the CUORICINO $^{130}Te$ neutrinoless double-beta ($\nbb$) decay experiment is given and recent results are reported. CUORICINO is an array of 62 tellurium oxide ($TeO_{2}$) bolometers with an active mass of 40.7 kg. It is cooled to $\sim 8-10$ mK by a dilution refrigerator shielded from environmental radioactivity and energetic neutrons. It is running in the Laboratori…
▽ More
A detailed description of the CUORICINO $^{130}Te$ neutrinoless double-beta ($\nbb$) decay experiment is given and recent results are reported. CUORICINO is an array of 62 tellurium oxide ($TeO_{2}$) bolometers with an active mass of 40.7 kg. It is cooled to $\sim 8-10$ mK by a dilution refrigerator shielded from environmental radioactivity and energetic neutrons. It is running in the Laboratori Nazionali del Gran Sasso (LNGS) in Assergi, Italy. These data represent an exposure of $11.83\textrm{kg}...\textrm{y}$ or 91 mole-years of $^{130}Te$. No evidence for $\nbb$-decay was observed and a limit of $T^{0ν}_{1/2}(^{130}Te)\geq3.0\times10^{24}$ y (90% C.L.) is set. This corresponds to an upper limit on the effective mass, $< m_ν>$, between 0.19 and 0.68 eV when analyzed with the many published nuclear structure calculations. In the context of these nuclear models, the values fall within the range corresponding to the claim of evidence of $\nbb$-decay by H.V. Klapdor-Kleingrothaus, \textit{et al.} The experiment continues to acquire data.
△ Less
Submitted 22 September, 2008; v1 submitted 23 February, 2008;
originally announced February 2008.
-
Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K
Authors:
L. Gottardi,
A. de Waard,
A. Usenko,
G. Frossati,
M. Podt,
J. Flokstra,
M. Bassan,
V. Fafone,
Y. Minenkov,
A. Rocchi
Abstract:
We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output sygnal. We measured a peak strain sensitivity of…
▽ More
We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output sygnal. We measured a peak strain sensitivity of $1.5\cdot 10^{-20} Hz^{-1/2}$ at 2942.9 Hz. A strain sensitivity of better than $5\cdot 10{-20}Hz{-1/2}$ has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than one order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3kHz range.
△ Less
Submitted 1 May, 2007;
originally announced May 2007.
-
Catastrophe observation in a Josephson junction system
Authors:
M. G. Castellano,
F. Chiarello,
R. Leoni,
F. Mattioli,
G. Torrioli,
P. Carelli,
M. Cirillo,
C. Cosmelli,
A. de Waard,
G. Frossati,
N. Grønbech-Jensen,
S. Poletto
Abstract:
We report on a direct quantitative comparison between Thom's general catastrophe theory for systems presenting discontinuous behavior and experimental reality. It is demonstrated that the model provides a striking quantitative description of the measured experimental features of the complex nonlinear system generating the most appealing class of sensors and devices nowadays used in experiments,…
▽ More
We report on a direct quantitative comparison between Thom's general catastrophe theory for systems presenting discontinuous behavior and experimental reality. It is demonstrated that the model provides a striking quantitative description of the measured experimental features of the complex nonlinear system generating the most appealing class of sensors and devices nowadays used in experiments, namely the Superconducting Quantum Interference Devices (SQUIDs). The parameter space of the SQUID system that we investigate displays all the features associated with a butterfly catastrophe, namely a catastrophe expected for a system having four control parameters and one state variable.
△ Less
Submitted 5 May, 2009; v1 submitted 2 September, 2006;
originally announced September 2006.
-
A New Limit on the Neutrinoless DBD of 130Te
Authors:
C. Arnaboldi,
D. R. Artusa,
F. T. Avignone III,
M. Balata,
I. Bandac,
M. Barucci,
J. W. Beeman,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Carbone,
S. Cebrian,
O. Cremonesi,
R. J. Creswick,
A. de Waard,
H. A. Farach,
E. Fiorini,
G. Frossati,
E. Guardincerri,
A. Giuliani,
P. Gorla,
E. E. Haller,
J. McDonald,
E. B. Norman,
A. Nucciotti
, et al. (16 additional authors not shown)
Abstract:
We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution refrigerator, heavily shielded against environmental radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK in the Gran Sasso Undergrou…
▽ More
We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution refrigerator, heavily shielded against environmental radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK in the Gran Sasso Underground Laboratory. Temperature pulses induced by particle interacting in the crystals are recorded and measured by means of Neutron Transmutation Doped thermistors. The gain of each bolometer is stabilized with voltage pulses developed by a high stability pulse generator across heater resistors put in thermal contact with the absorber.
The calibration is performed by means of two thoriated wires routinely inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of 130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the lifetime of this process. Taking largely into account the uncertainties in the theoretical values of nuclear matrix elements, this implies an upper boud on the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This sensitivity is similar to those of the 76Ge experiments.
△ Less
Submitted 13 January, 2005;
originally announced January 2005.
-
CUORE: A Cryogenic Underground Observatory for Rare Events
Authors:
C. Arnaboldi,
F. T. Avignone III,
J. Beeman,
M. Barucci,
M. Balata,
C. Brofferio,
C. Bucci,
S. Cebrian,
R. J. Creswick,
S. Capelli,
L. Carbone,
O. Cremonesi,
A. de Ward,
E. Fiorini,
H. A. Farach,
G. Frossati,
A. Giuliani,
D. Giugni,
P. Gorla,
E. E. Haller,
I. G. Irastorza,
R. J. McDonald,
A. Morales,
E. B. Norman,
P. Negri
, et al. (14 additional authors not shown)
Abstract:
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark m…
▽ More
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.
△ Less
Submitted 20 December, 2002;
originally announced December 2002.
-
Resonance widening in spherical GW detectors: model descriptions of the dissipation processes
Authors:
Eugenio Coccia,
Viviana Fafone,
Giorgio Frossati,
Arlette de Waard,
J. Alberto Lobo
Abstract:
Internal friction effects are responsible for line widening of the resonance frequencies in mechanical oscillators and result in damped oscillations of its eigenmodes with a decay time Q/ω. We study the solutions to the equations of motion for the case of spherical oscillators, to be used as next generation of acoustic gravitational wave detectors, based on various different assumptions about th…
▽ More
Internal friction effects are responsible for line widening of the resonance frequencies in mechanical oscillators and result in damped oscillations of its eigenmodes with a decay time Q/ω. We study the solutions to the equations of motion for the case of spherical oscillators, to be used as next generation of acoustic gravitational wave detectors, based on various different assumptions about the material's constituent equations. Quality factor dependence on mode frequency is determined in each case, and a discussion of its applicability to actual gravitational wave detectors is made on the basis of available experimental evidence.
△ Less
Submitted 28 October, 2002;
originally announced October 2002.