-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Development of large-volume $^{130}$TeO$_2$ bolometers for the CROSS $2β$ decay search experiment
Authors:
F. T. Avignone III,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
L. Dumoulin,
F. Ferella,
F. Ferri,
A. Gallas,
A. Giuliani,
C. Gotti,
P. Gras,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (14 additional authors not shown)
Abstract:
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a fe…
▽ More
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a few ppm of the total concentration of residual elements (the main impurity is Fe). The purest part of the ingot (the first ~200 mm, ~80% of the total length of the cylindrical part of the ingot) was determined by scanning segregation profiles of impurities (both on the surface and in center of the ingot) and used for the $^{130}$TeO$_2$ powder production with no evidence of re-contamination. The crystal growth was verified with precursors produced from powder with natural Te isotopic composition, and two small-size (20x20x10 mm) samples were tested at a sea-level laboratory showing high bolometric and spectrometric performance together with acceptable $^{210}$Po content (below 10 mBq/kg). This growth method was then applied for the production of six large cubic $^{130}$TeO$_2$ crystals for the CROSS experiment and 4 of them were taken randomly to be characterized at the Canfranc underground laboratory, in the CROSS-dedicated low-background cryogenic facility. Two $^{130}$TeO$_2$ samples were coated with a thin metal film in form of Al layer (on 4 sides) or AlPd grid (on a single side) to investigate the possibility to tag surface events by pulse-shape discrimination. Similarly to the small natural precursors, large-volume $^{130}$TeO$_2$ bolometers show high performance and even better internal purity ($^{210}$Po activity ~ 1 mBq/kg, while activities of $^{228}$Th and $^{226}$Ra are below 0.01 mBq/kg), satisfying requirements for the CROSS and, potentially, next-generation experiments.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
Authors:
D. Auguste,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
T. Dixon,
L. Dumoulin,
F. Ferri,
A. Gallas,
A. Giuliani,
C. Gotti,
P. Gras,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (13 additional authors not shown)
Abstract:
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, kee** an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper si…
▽ More
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, kee** an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper side) in the Cu frame, allowing for a modular construction of a large-scale array. Two designs are released: the initial Thick version contains around 15% of Cu over the crystal mass (lithium molybdate, LMO), while this ratio is reduced to ~6% in a finer (Slim) design. Both designs were tested extensively at aboveground (IJCLab, France) and underground (LSC, Spain) laboratories. In particular, at LSC we used a pulse-tube-based CROSS facility to operate a 6-crystal array of LMOs enriched/depleted in $^{100}$Mo. The tested LMOs show high spectrometric performance in both designs; notably, the measured energy resolution is 5--7 keV FWHM at 2615 keV $γ$s, nearby the Q-value of $^{100}$Mo (3034 keV). Due to the absence of a reflective cavity around LMOs, a low scintillation signal is detected by Ge bolometers: ~0.3 keV (~150 photons) for 1-MeV $γ$($β$) LMO-event. Despite that, an acceptable separation between $α$ and $γ$($β$) events is achieved with most devices. The highest efficiency is reached with light detectors in the Thick design thanks to a lower baseline noise width (0.05--0.09 keV RMS) when compared to that obtained in the Slim version (0.10--0.35 keV RMS). Given the pivotal role of bolometric photodetectors for particle identification and random coincidences rejection, we will use the structure here described with upgraded light detectors, featuring thermal signal amplification via the Neganov-Trofimov-Luke effect, as also demonstrated in the present work.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
ANAIS-112 three years data: a sensitive model independent negative test of the DAMA/LIBRA dark matter signal
Authors:
Iván Coarasa,
Julio Amaré,
Jaime Apilluelo,
Susana Cebrián,
David Cintas,
Eduardo García,
María Martínez,
Miguel Ángel Oliván,
Ysrael Ortigoza,
Alfonso Ortiz de Solórzano,
Tamara Pardo,
Jorge Puimedón,
Ana Salinas,
María Luisa Sarsa,
Patricia Villar
Abstract:
Weakly interacting massive particles (WIMPs) are well-motivated candidates for dark matter. One signature of galactic WIMPs is the annual modulation expected in a detector's interaction rate, which arises from Earth's rotation around the Sun. Over two decades, the DAMA/LIBRA experiment has observed such modulation with 250 kg of NaI(Tl) scintillators, in accordance with WIMP expectations but incon…
▽ More
Weakly interacting massive particles (WIMPs) are well-motivated candidates for dark matter. One signature of galactic WIMPs is the annual modulation expected in a detector's interaction rate, which arises from Earth's rotation around the Sun. Over two decades, the DAMA/LIBRA experiment has observed such modulation with 250 kg of NaI(Tl) scintillators, in accordance with WIMP expectations but inconsistent with the negative results of other experiments. The signal, however, depends on the target, so in order to either validate or refute the DAMA signal it is necessary to replicate the experiment using the same material. This is the goal of the ANAIS-112 experiment, currently underway since August 2017 with 112.5 kg of NaI(Tl). In this work, we present a reanalysis of three years of data employing an improved analysis chain to enhance the experimental sensitivity. The results presented here are consistent with the absence of modulation and inconsistent with DAMA's observation at nearly 3$σ$ C.L., with the potential to reach a 5$σ$ level within 8 years of data collection. Additionally, we explore the impact of different scintillation quenching factors in the comparison between ANAIS-112 and DAMA/LIBRA.
△ Less
Submitted 26 April, 2024;
originally announced April 2024.
-
Using Micromegas detectors for direct dark matter searches: challenges and perspectives
Authors:
K. Altenmueller,
. Antolin,
D. Calvet,
F. R. Candon,
J. Castel,
S. Cebrian,
C. Cogollos,
T. Dafni,
D. Diez Ibanez,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
H. Gomez,
Y. Gu,
A. Ezquerro,
I. G Irastorza,
G. Luzon,
C. Margalejo,
H. Mirallas,
L. Obis,
A. Ortiz de Solorzano,
T. Papaevangelou,
O. Perez,
E. Picatoste,
J. Porron
, et al. (5 additional authors not shown)
Abstract:
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful s…
▽ More
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful signal-background discrimination. The Micromegas technology of the microbulk type is particularly suited to low-background applications and is being exploited by detectors for CAST and IAXO (solar axions) and TREX-DM (low-mass WIMPs) experiments. Challenges for the future include reducing intrinsic background levels, reaching lower energy detection levels, and technical issues such as robustness of detector, new design choices, novel gas mixtures and operation points, scaling up to larger detector sizes, handling large readout granularity, etc. We report on the status and prospects of the development ongoing in the context of IAXO and TREX-DM experiments, pointing to promising perspectives for the use of Micromegas detectors in directdark matter searches
△ Less
Submitted 15 April, 2024;
originally announced April 2024.
-
Background discrimination with a Micromegas detector prototype and veto system for BabyIAXO
Authors:
K. Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafni,
D. Díez-Ibañez,
A. Ezquerro,
E. Ferrer-Ribas,
J. Galan,
J. Galindo,
J. A. García,
A. Giganon,
C. Goblin,
I. G. Irastorza,
C. Loiseau,
G. Luzón,
X. F. Navick,
C. Margalejo,
H. Mirallas,
L. Obis,
A. Ortiz de Solórzano,
T. Papaevangelou,
O. Pérez,
A. Quintana,
J. Ruz,
J. K. Vogel
Abstract:
In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The go…
▽ More
In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The goal of the measurement was to study techniques for background discrimination. In addition to common techniques we used a multi-layer veto system designed to tag cosmogenic neutron background. Over an effective time of 52 days, a background level of $8.6 \times 10^{-7}\,\text{counts keV}^{-1}\,\text{cm}^{-2} \, \text{s}^{-1}$ was reached in a laboratory at above ground level. This is the lowest background level achieved at surface level. In this paper we present the experimental setup, show simulations of the neutron-induced background, and demonstrate the process to identify background signals in the data. Finally, prospects to reach lower background levels down to $10^{-7} \, \text{counts keV}^{-1} \, \text{cm}^{-2} \, \text{s}^{-1}$ will be discussed.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
BINGO innovative assembly for background reduction in bolometric $0νββ$ experiments
Authors:
A. Armatol,
C. Augier,
I. C. Bandac,
D. Baudin,
G. Benato,
V. Berest,
L. Bergé,
J. Billard,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
F. A. Danevich,
M. De Jesus,
T. Dixon,
L. Dumoulin,
F. Ferri,
J. Gascon,
A. Giuliani,
H. Gomez,
C. Gotti,
Ph. Gras,
M. Gros,
A. Juillard,
H. Khalife,
V. V. Kobychev
, et al. (23 additional authors not shown)
Abstract:
BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on develo** innovative technologies (a detector assembly, cryogenic photodetectors and active veto) to achieve a very low background index, of the order of $10^{-5}$ counts/(keV kg yr) in th…
▽ More
BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on develo** innovative technologies (a detector assembly, cryogenic photodetectors and active veto) to achieve a very low background index, of the order of $10^{-5}$ counts/(keV kg yr) in the region of interest. The BINGO demonstrator, called MINI-BINGO, is designed to investigate the promising double-beta-decay isotopes $^{100}$Mo and $^{130}$Te and it will be composed of Li$_2$MoO$_4$ and TeO$_2$ crystals coupled to bolometric light detectors and surrounded by a Bi$_4$Ge$_3$O$_{12}$-based veto. This will allow us to reject a significant background in bolometers caused by surface contamination from $α$-active radionuclides by means of light yield selection and to mitigate other sources of background, such as surface contamination from $β$-active radionuclides, external $γ$ radioactivity, and pile-up due to random coincidence of background events. This paper describes an R\&D program towards the BINGO goals, particularly focusing on the development of an innovative assembly designed to reduce the passive materials within the line of sight of the detectors, which is expected to be a dominant source of background in next-generation bolometric experiments. We present the performance of two prototype modules -- housing four cubic (4.5-cm side) Li$_2$MoO$_4$ crystals in total -- operated in the Canfranc underground laboratory in Spain within a facility developed for the CROSS double-beta-decay experiment.
△ Less
Submitted 8 July, 2024; v1 submitted 19 February, 2024;
originally announced February 2024.
-
Searching for WIMPs with TREX-DM: achievements and challenges
Authors:
Juan F. Castel,
Susana Cebrián,
Theopisti Dafni,
David Díez-Ibáñez,
Álvaro Ezquerro,
Javier Galán,
Juan Antonio García,
Igor G. Irastorza,
María Jiménez,
Gloria Luzón,
Cristina Margalejo,
Ángel de Mira,
Hector Mirallas,
Luis Obis,
Alfonso Ortiz de Solórzano,
Oscar Pérez,
Jaime Ruz,
Julia Vogel
Abstract:
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day…
▽ More
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day$^{-1}$ in the region from 1 to 7 keV$_{ee}$, the experiment demonstrates its potential to search for low-mass WIMPs. Two of the most important challenges currently faced are the reduction of both, background level and energy threshold. With respect to the energy threshold, recently a new readout plane is being developed, based on the combination of Micromegas and GEM technologies, aiming to have a pre-amplification stage that would permit very low energy thresholds, close to the single-electron ionization energy. With respect to the background reduction, apart from studies to identify and minimize contamination population, a high sensitivity alpha detector is being developed in order to allow a proper material selection for the TREX-DM detector components. Both challenges, together with the optimization of the gas mixture used as target for the WIMP detection, will take TREX-DM to explore regions of WIMP's mass below 1 GeV c$^{-2}$.
△ Less
Submitted 19 December, 2023;
originally announced December 2023.
-
Neutron calibrations in dark matter searches: the ANAIS-112 case
Authors:
T. Pardo,
J. Amaré,
J. Apilluelo,
S. Cebrián,
D. Cintas,
I. Coarasa,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
M. Pellicer,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar
Abstract:
ANAIS is a direct dark matter detection experiment whose goal is to confirm or refute in a model independent way the positive annual modulation signal claimed by DAMA/LIBRA. Consisting of 112.5 kg of NaI(Tl) scintillators, ANAIS-112 is taking data at the Canfranc Underground Laboratory in Spain since August, 2017. Results corresponding to the analysis of three years of data are compatible with the…
▽ More
ANAIS is a direct dark matter detection experiment whose goal is to confirm or refute in a model independent way the positive annual modulation signal claimed by DAMA/LIBRA. Consisting of 112.5 kg of NaI(Tl) scintillators, ANAIS-112 is taking data at the Canfranc Underground Laboratory in Spain since August, 2017. Results corresponding to the analysis of three years of data are compatible with the absence of modulation and incompatible with DAMA/LIBRA. However, testing this signal relies on the knowledge of the scintillation quenching factors (QF), which measure the relative efficiency for the conversion into light of the nuclear recoil energy with respect to the same energy deposited by electrons. Previous measurements of the QF in NaI(Tl) show a large dispersion. Consequently, in order to better understand the response of the ANAIS-112 detectors to nuclear recoils, a specific neutron calibration program has been developed. This program combines two different approaches: on the one hand, QF measurements were carried out in a monoenergetic neutron beam; on the other hand, the study presented here aims at the evaluation of the QF by exposing directly the ANAIS-112 crystals to neutrons from low activity $^{252}$Cf sources, placed outside the lead shielding. Comparison between these onsite neutron measurements and detailed GEANT4 simulations will be presented, confirming that this approach allows testing different QF models.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
ANAIS-112: updated results on annual modulation with three-year exposure
Authors:
Iván Coarasa,
Julio Amaré,
Jaime Apilluelo,
Susana Cebrián,
David Cintas,
Eduardo García,
María Martínez,
Miguel Ángel Oliván,
Ysrael Ortigoza,
Alfonso Ortiz de Solórzano,
Tamara Pardo,
Jorge Puimedón,
Ana Salinas,
María Luisa Sarsa,
Patricia Villar
Abstract:
The ANAIS experiment is intended to search for dark matter annual modulation with ultrapure NaI(Tl) scintillators in order to provide a model independent confirmation or refutation of the long-standing DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. Other experiments exclude the region of parameters singled out by DAMA/LIBRA. Howe…
▽ More
The ANAIS experiment is intended to search for dark matter annual modulation with ultrapure NaI(Tl) scintillators in order to provide a model independent confirmation or refutation of the long-standing DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. Other experiments exclude the region of parameters singled out by DAMA/LIBRA. However, these experiments use different target materials, so the comparison of their results depends on the models assumed for the dark matter particle and its distribution in the galactic halo. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc., disposed in a 3$\times$3 matrix configuration, is taking data smoothly with excellent performance at the Canfranc Underground Laboratory, Spain, since August, 2017. Last published results corresponding to three-year exposure were compatible with the absence of modulation and incompatible with DAMA/LIBRA for a sensitivity above 2.5$σ$ C.L. Present status of the experiment and a reanalysis of the first 3 years data using new filtering protocols based on machine-learning techniques are reported. This reanalysis allows to improve the sensitivity previously achieved for the DAMA/LIBRA signal. Updated sensitivity prospects are also presented: with the improved filtering, testing the DAMA/LIBRA signal at 5$σ$ will be within reach in 2025.
△ Less
Submitted 4 November, 2023;
originally announced November 2023.
-
Directionality of nuclear recoils in a liquid argon time projection chamber
Authors:
The DarkSide-20k Collaboration,
:,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
M. Ave,
I. Ch. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado-Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
V. Bocci,
W. M. Bonivento,
B. Bottino,
M. G. Boulay,
J. Busto,
M. Cadeddu
, et al. (243 additional authors not shown)
Abstract:
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scint…
▽ More
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence level
△ Less
Submitted 28 July, 2023;
originally announced July 2023.
-
Test of $^{116}$CdWO$_4$ and Li$_2$MoO$_4$ scintillating bolometers in the CROSS underground facility with upgraded detector suspension
Authors:
A. Ahmine,
I. C. Bandac,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
T. Dixon,
L. Dumoulin,
F. Ferri,
A. Giuliani,
C. Gotti,
P. Gras,
D. L. Helis,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros
, et al. (16 additional authors not shown)
Abstract:
In preparation to the CROSS $2β$ decay experiment, we installed a new detector suspension with magnetic dum** inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditio…
▽ More
In preparation to the CROSS $2β$ decay experiment, we installed a new detector suspension with magnetic dum** inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditions and for comparing bolometric performance of an advanced Li2MoO4 crystal developed in the framework of the CLYMENE project, in view of next-generation double-beta decay experiments like CUPID. We cooled down detectors to 15 mK and achieved high performance for all tested devices. In particular both CWO-enr and LMO bolometers demonstrated the energy resolution of 6 keV FWHM for the 2.6 MeV gamma quanta, among the best for thermal detectors based on such compounds. The baseline noise resolution (FWHM) of the CWO-enr detector was improved by 2 keV, compared to the best previous measurement of this detector in the CROSS facility, while the noise of the Ge-based optical bolometer was improved by a factor 2, to 100 eV FWHM. Despite of the evident progress in the improving of noise conditions of the set-up, we see high-frequency harmonics of a pulse-tube induced noise, suggesting a noise pick-up by cabling. Another Ge light detector was assisted with the signal amplification exploiting the Neganov-Trofimov-Luke effect, which allowed to reach 20 eV FWHM noise resolution by applying 60 V electrode bias. Highly-efficient particle identification was achieved with both detectors, despite a low scintillation efficiency of the LMO material. The radiopurity level of the LMO crystal is rather high; only traces of 210Po and 226Ra were detected (0.1 mBq/kg each), while the 228Th activity is expected to be at least an order of magnitude lower, as well as a 40K activity is found to be < 6 mBq/kg.
△ Less
Submitted 27 July, 2023;
originally announced July 2023.
-
Li$_2$$^{100\textrm{depl}}$MoO$_4$ Scintillating Bolometers for Rare-Event Search Experiments
Authors:
I. C. Bandac,
A. S. Barabash,
L. Bergé,
Yu. A. Borovlev,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
L. Dumoulin,
F. Ferri,
A. Giuliani,
C. Gotti,
Ph. Gras,
V. D. Grigorieva,
A. Ianni,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
M. Madhukuttan,
E. P. Makarov,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (13 additional authors not shown)
Abstract:
We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-$β$ active isotope $^{100}$Mo (Li$_2$$^{100\textrm{depl}}$MoO$_4$). We used two Li$_2$$^{100\textrm{depl}}$MoO$_4$ cubic samples, 45 mm side and 0.28 kg each, produced following purification and crystallization protocols developed for double-$β$ search experimen…
▽ More
We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-$β$ active isotope $^{100}$Mo (Li$_2$$^{100\textrm{depl}}$MoO$_4$). We used two Li$_2$$^{100\textrm{depl}}$MoO$_4$ cubic samples, 45 mm side and 0.28 kg each, produced following purification and crystallization protocols developed for double-$β$ search experiments with $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals. Bolometric Ge detectors were utilized to register scintillation photons emitted by the Li$_2$$^{100\textrm{depl}}$MoO$_4$ crystal scintillators. The measurements were performed in the CROSS cryogenic set-up at the Canfranc underground laboratory (Spain). We observed that the Li$_2$$^{100\textrm{depl}}$MoO$_4$ scintillating bolometers are characterized by excellent spectrometric performance ($\sim$3--6 keV FWHM at 0.24--2.6 MeV $γ$'s), moderate scintillation signal ($\sim$0.3--0.6 keV/MeV depending on light collection conditions) and high radiopurity ($^{228}$Th and $^{226}$Ra activities are below a few $μ$Bq/kg), comparable to the best reported results of low-temperature detectors based on Li$_2$MoO$_4$ with natural or $^{100}$Mo-enriched molybdenum content. Prospects of Li$_2$$^{100\textrm{depl}}$MoO$_4$ bolometers for use in rare-event search experiments are briefly discussed.
△ Less
Submitted 25 April, 2023;
originally announced April 2023.
-
Ultra low background Micromegas detectors for BabyIAXO solar axion search
Authors:
E. Ferrer-Ribas,
K. Altenmüller,
B. Biasuzzi,
J. F. Castel,
S. Cebrián,
T. Dafni,
K. Desch,
D. Díez-Ibañez,
J. Galán,
J. Galindo,
J. A. García,
A. Giganon,
C. Goblin,
I. G. Irastorza,
J. Kaminski,
G. Luzón,
C. Margalejo,
H. Mirallas,
X. F. Navick,
L. Obis,
A. Ortiz de Solórzano,
J. von Oy,
T. Papaevangelou,
O. Pérez,
E. Picatoste
, et al. (5 additional authors not shown)
Abstract:
The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potentia…
▽ More
The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery.
One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.
△ Less
Submitted 22 May, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Enhanced light signal for the suppression of pile-up events in Mo-based bolometers for the $0νββ$ decay search
Authors:
A. Ahmine,
A. Armatol,
I. Bandac,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
T. Dixon,
L. Dumoulin,
A. Giuliani,
Ph. Gras,
F. Ferri,
L. Imbert,
H. Khalife,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi,
C. Nones,
E. Olivieri,
A. Ortiz de Solòrzano,
G. Pessina,
D. V. Poda,
Th. Redon,
J. A. Scarpaci
, et al. (2 additional authors not shown)
Abstract:
Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of $^{100}$Mo with macro-bolometers, due to their modest time resolution. Scintillating bolometers as those based on Li$_2$MoO$_4$ crystals and employed in the CROSS and CUPID experiments can eventually exploit the coincident fast signal detected in a light detector to red…
▽ More
Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of $^{100}$Mo with macro-bolometers, due to their modest time resolution. Scintillating bolometers as those based on Li$_2$MoO$_4$ crystals and employed in the CROSS and CUPID experiments can eventually exploit the coincident fast signal detected in a light detector to reduce this background. However, the scintillation provides a modest signal-to-noise ratio, making difficult a pile-up pulse-shape recognition and rejection at timescales shorter than a few ms. Neganov-Trofimov-Luke assisted light detectors (NTL-LDs) offer the possibility to effectively increase the signal-to-noise ratio, preserving a fast time-response, and enhance the capability of pile-up rejection via pulse shape analysis. In this article we present: a) an experimental work performed with a Li$_2$MoO$_4$ scintillating bolometer, studied in the framework of the CROSS experiment, and utilizing a NTL-LD; b) a simulation method to reproduce, synthetically, randomly coincident two-neutrino double-beta decay events; c) a new analysis method based on a pulse-shape discrimination algorithm capable of providing high pile-up rejection efficiencies. We finally show how the NTL-LDs offer a balanced solution between performance and complexity to reach background index $\sim$$10^{-4}$ counts/keV/kg/year with 280~g Li$_2$MoO$_4$ ($^{100}$Mo enriched) bolometers at 3034 keV, the Q-value of the double-beta decay, and target the goal of a next generation experiment like CUPID.
△ Less
Submitted 3 April, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors
Authors:
K.,
Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafní,
D. Díez-Ibáñez,
J. Galán,
J. Galindo,
J. A. García,
I. G. Irastorza,
I. Katsioulas,
P. Knights,
G. Luzón,
I. Manthos,
C. Margalejo,
J. Matthews,
K. Mavrokoridis,
H. Mirallas,
T. Neep,
K. Nikolopoulos,
L. Obis,
A. Ortiz de Solórzano,
O. Pérez,
B. Philippou,
R. Ward
Abstract:
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potenti…
▽ More
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
Improving ANAIS-112 sensitivity to DAMA/LIBRA signal with machine learning techniques
Authors:
I. Coarasa,
J. Apilluelo,
J. Amaré,
S. Cebrián,
D. Cintas,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
T. Pardo,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar
Abstract:
The DAMA/LIBRA observation of an annual modulation in the detection rate compatible with that expected for dark matter particles from the galactic halo has accumulated evidence for more than twenty years. It is the only hint of a direct detection of the elusive dark matter, but it is in strong tension with the negative results of other very sensitive experiments, requiring ad-hoc scenarios to reco…
▽ More
The DAMA/LIBRA observation of an annual modulation in the detection rate compatible with that expected for dark matter particles from the galactic halo has accumulated evidence for more than twenty years. It is the only hint of a direct detection of the elusive dark matter, but it is in strong tension with the negative results of other very sensitive experiments, requiring ad-hoc scenarios to reconcile all the present experimental results. Testing the DAMA/LIBRA result using the same target material, NaI(Tl), removes the dependence on the particle and halo models and is the goal of the ANAIS-112 experiment, taking data at the Canfranc Underground Laboratory in Spain since August 2017 with 112.5 kg of NaI(Tl). At very low energies, the detection rate is dominated by non-bulk scintillation events and careful event selection is mandatory. This article summarizes the efforts devoted to better characterize and filter this contribution in ANAIS-112 data using a boosted decision tree (BDT), trained for this goal with high efficiency. We report on the selection of the training populations, the procedure to determine the optimal cut on the BDT parameter, the estimate of the efficiencies for the selection of bulk scintillation in the region of interest (ROI), and the evaluation of the performance of this analysis with respect to the previous filtering. The improvement achieved in background rejection in the ROI, but moreover, the increase in detection efficiency, push the ANAIS-112 sensitivity to test the DAMA/LIBRA annual modulation result around 3$σ$ with three-year exposure, being possible to reach 5$σ$ by extending the data taking for a few more years than the scheduled 5 years which were due in August 2022.
△ Less
Submitted 5 September, 2023; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Authors:
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. Ch. Avetisov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
E. Berzin,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino
, et al. (274 additional authors not shown)
Abstract:
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu…
▽ More
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino floor for GeV-scale masses and significant sensitivity down to 10 MeV/c$^2$ considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector's sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.
△ Less
Submitted 20 June, 2023; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Long term measurement of the $^{222}$Rn concentration in the Canfranc Underground Laboratory
Authors:
J. Amaré,
I. Bandac,
A. Blancas,
S. Borjabad,
S. Buisán,
S. Cebrián,
D. Cintas,
I. Coarasa,
E. García,
M. Martínez,
R. Núñez Lagos,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pérez,
J. Puimedón,
S. Rodríguez,
A. Salinas,
M. L. Sarsa,
P. Villar
Abstract:
We report the results of six years (2013-2018) of measurements of $^{222}$Rn air concentration, relative humidity, atmospheric pressure and temperature in the halls A, B and C of the Canfranc Underground Laboratory (LSC). We have calculated all the Pearson correlation coefficients among these parameters and we have found a positive correlation between the $^{222}$Rn concentration and the relative…
▽ More
We report the results of six years (2013-2018) of measurements of $^{222}$Rn air concentration, relative humidity, atmospheric pressure and temperature in the halls A, B and C of the Canfranc Underground Laboratory (LSC). We have calculated all the Pearson correlation coefficients among these parameters and we have found a positive correlation between the $^{222}$Rn concentration and the relative humidity. Both correlated variables show a seasonal periodicity. The joint analysis of laboratory data and four years (2015-2018) of the meteorological variables outside the laboratory shows the correlation between the $^{222}$Rn concentration and the outside temperature. The collected information stresses the relevance of designing good Rn-mitigation strategies in current and future experiments at LSC; in particular, we have checked for two years (2017-2018) the good performance of the mitigation procedure of the ANAIS--112 experiment. Finally, in another measurement (2019-2021) for two years of live time, we report an upper limit to the residual $^{222}$Rn content of the radon-free air provided by the radon abatement system installed in the laboratory.
△ Less
Submitted 25 March, 2022;
originally announced March 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination
Authors:
Konrad Altenmüller,
Juan F. Castel,
Susana Cebrián,
Theopisti Dafni,
David Díez-Ibáñez,
Javier Galán,
Javier Galindo,
Juan Antonio García,
Igor G. Irastorza,
Gloria Luzón,
Cristina Margalejo,
Hector Mirallas,
Luis Obis,
Alfonso Ortiz de Solórzano,
Oscar Pérez
Abstract:
Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one of the most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with a segmented Micromegas, for the direct measurement of $^{210}$Pb surface contamination of flat samples. The detection concept exploits the readout capabi…
▽ More
Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one of the most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with a segmented Micromegas, for the direct measurement of $^{210}$Pb surface contamination of flat samples. The detection concept exploits the readout capabilities of the Micromegas detectors for the reconstruction of $^{210}$Po alpha tracks to increase the signal-to-background ratio. We report here on the design and realization of a first 26$\times$26 cm$^2$ non-radiopure prototype, with which the detection concept is demonstrated by the use of a new algorithm for the reconstruction of alpha tracks. AlphaCAMM aims for minimum detectable $^{210}$Pb activities of $100$ nBq cm$^{-2}$ and sensitivity upper limits about $60$ nBq cm$^{-2}$ at 95\% of C.L., which requires an intrinsic background level of $5\times10^{-8}$ alphas cm$^{-2}$ s$^{-1}$. We discuss here the prospects to reach these sensitivity goals with a radiopure AlphaCAMM prototype currently under construction.
△ Less
Submitted 20 July, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
-
Radon Mitigation Applications at the Laboratorio Subterraneo de Canfranc (LSC)
Authors:
J. Perez-Perez,
J. C. Amare,
I. C. Bandac,
A. Bayo,
S. Borjabad-Sanchez,
J. M. Calvo-Mozota,
L. Cid-Barrio,
R. Hernandez-Antolin,
B. Hernandez-Molinero,
P. Novella,
K. Pelczar,
C. Peña-Garay,
B. Romeo,
A. Ortiz de Solorzano,
M. Sorel,
J. Torrent,
A. Uson,
A. Wojna-Pelczar,
G. Zuzel
Abstract:
The Laboratorio Subterra neo de Canfranc (LSC) is the national hub for low radioactivity techniques and the associated scientific and technological applications. The concentration of the airborne radon is a major component of the radioactive budget in the neighborhood of the detectors. The LSC hosts a Radon Abatement System (RAS), which delivers a radon suppressed air with < 1 mBq/m3 of 222Rn. The…
▽ More
The Laboratorio Subterra neo de Canfranc (LSC) is the national hub for low radioactivity techniques and the associated scientific and technological applications. The concentration of the airborne radon is a major component of the radioactive budget in the neighborhood of the detectors. The LSC hosts a Radon Abatement System (RAS), which delivers a radon suppressed air with < 1 mBq/m3 of 222Rn. The radon content in the air is continuously monitored with an Electrostatic Radon Monitor (ERM). Measurements with the doble beta decay demonstrators NEXT-NEW and CROSS and the gamma HPGe detectors demonstrate the important reduction of the radioactive background due to the replaced air in the vicinity of the detectors. We also discuss the use of this facility in the LSC current program which includes NEXT-100, low background biology experiments and radiopure copper electroformation equipment placed in the radon-free clean room.
△ Less
Submitted 15 March, 2022; v1 submitted 31 December, 2021;
originally announced December 2021.
-
Machine-learning techniques applied to three-year exposure of ANAIS-112
Authors:
I. Coarasa,
J. Apilluelo,
J. Amaré,
S. Cebrián,
D. Cintas,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar
Abstract:
ANAIS is a direct dark matter detection experiment aiming at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. ANAIS-112, located at the Canfranc Underground Laboratory in Spain, is operating an array of 3$\times$3 ultrapure NaI(Tl) crystals with a total mass of 112.5 kg since August 2017. The t…
▽ More
ANAIS is a direct dark matter detection experiment aiming at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. ANAIS-112, located at the Canfranc Underground Laboratory in Spain, is operating an array of 3$\times$3 ultrapure NaI(Tl) crystals with a total mass of 112.5 kg since August 2017. The trigger rate in the region of interest (1-6 keV) is dominated by non-bulk scintillation events. In order to discriminate these noise events from bulk scintillation events, robust filtering protocols have been developed. Although this filtering procedure works very well above 2 keV, the measured rate from 1 to 2 keV is about 50% higher than expected according to our background model, and we cannot discard non-bulk scintillation events as responsible of that excess. In order to improve the rejection of noise events, a Boosted Decision Tree has been developed and applied. With this new PMT-related noise rejection algorithm, the ANAIS-112 background between 1 and 2 keV is reduced by almost 30%, leading to an increase in sensitivity to the annual modulation signal. The reanalysis of the three years of ANAIS-112 data with this technique is also presented.
△ Less
Submitted 20 October, 2021;
originally announced October 2021.
-
Background model of the ANAIS-112 dark matter experiment
Authors:
J Amare,
S Cebrian,
D Cintas,
I Coarasa,
E Garcia,
M Martinez,
M A Olivan,
Y Ortigoza,
A Ortiz de Solorzano,
J Puimedon,
A Salinas,
M L Sarsa,
P Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules, is taking data since August, 2017 at the Canfranc Underground Laboratory (LSC) in Spain. Results from the analysis of three years of data are compatible…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules, is taking data since August, 2017 at the Canfranc Underground Laboratory (LSC) in Spain. Results from the analysis of three years of data are compatible with the absence of modulation. The background model developed for all nine ANAIS-112 detectors was established from commissioning data and non-blinded events in the first year of data taking. Now, background characterization is being improved profiting from the larger accumulated exposure available. Here, the background model is described and comparisons of model and measurements for energy spectra and counting rate time evolution for three-year exposure (considering different analysis conditions) are presented.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
Annual modulation results from three-year exposure of ANAIS-112
Authors:
J. Amare,
S. Cebrian,
D. Cintas,
I. Coarasa,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
A. Salinas,
M. L. Sarsa,
P. Villar
Abstract:
ANAIS (Annual modulation with NaI Scintillators) is a dark matter direct detection experiment consisting of 112.5 kg of NaI(Tl) detectors in operation at the Canfranc Underground Laboratory (LSC), in Spain, since August 2017. ANAIS' goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate having all the features e…
▽ More
ANAIS (Annual modulation with NaI Scintillators) is a dark matter direct detection experiment consisting of 112.5 kg of NaI(Tl) detectors in operation at the Canfranc Underground Laboratory (LSC), in Spain, since August 2017. ANAIS' goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate having all the features expected for the signal induced by dark matter particles in a standard galactic halo. This modulation, observed for about 20 years, is in strong tension with the negative results of other very sensitive experiments, but a model-independent comparison is still lacking. By using the same target material, NaI(Tl), such comparison is more direct and almost independent on dark matter particle and halo models. Here, we present the annual modulation analysis corresponding to three years of ANAIS data (for an effective exposure of 313.95 kg$\times$y), applying a blind procedure which updates that developed for the 1.5 years analysis, and later applied to 2 years. The analysis also improves the background modelling in the fitting of the region of interest rates. We obtain for the best fit in the [1-6] keV ([2-6] keV) energy region a modulation amplitude of -0.0034$\pm$0.0042 cpd/kg/keV (0.0003$\pm$0.0037 cpd/kg/keV), supporting the absence of modulation in our data, and incompatible with DAMA/LIBRA result at 3.3 (2.6) $σ$, for a sensitivity of 2.5 (2.7) $σ$. Moreover, we include two complementary analyses: a phase-free annual modulation search and the exploration of the possible presence of a periodic signal at other frequencies. Finally, we carry out several consistency checks of our result, and we update the ANAIS-112 projected sensitivity for the scheduled 5 years of operation.
△ Less
Submitted 31 May, 2021; v1 submitted 1 March, 2021;
originally announced March 2021.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
The TREX-DM experiment at the Canfranc Underground Laboratory
Authors:
J Castel,
S Cebrián,
T Dafni,
J Galán,
IG Irastorza,
G Luzón,
C Margalejo,
H Mirallas,
A Ortiz de Solórzano,
A Peiró,
E Ruiz-Chóliz
Abstract:
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly…
▽ More
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly presented.
△ Less
Submitted 22 March, 2020; v1 submitted 30 October, 2019;
originally announced October 2019.
-
ANAIS-112 status: two years results on annual modulation
Authors:
J. Amaré,
S. Cebrián,
D. Cintas,
I. Coarasa,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar
Abstract:
ANAIS (Annual modulation with NaI Scintillators) is a dark matter direct detection experiment located at the Canfranc Underground Laboratory (LSC), in Spain. The goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate compatible with the expected signal induced by dark matter particles in the galactic halo. This…
▽ More
ANAIS (Annual modulation with NaI Scintillators) is a dark matter direct detection experiment located at the Canfranc Underground Laboratory (LSC), in Spain. The goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate compatible with the expected signal induced by dark matter particles in the galactic halo. This signal, observed for about 20 years, is in strong tension with the negative results of other very sensitive experiments, but a direct comparison using the same target material, NaI(Tl), was still lacking. ANAIS-112, consisting of 112.5 kg of NaI(Tl) scintillators, is taking data at the LSC since August 2017. Here we present the preliminary annual modulation analysis corresponding to two years of data (exposure of 220.69 kg x y) and the ANAIS-112 projected sensitivity for the scheduled 5 y of operation.
△ Less
Submitted 30 October, 2019; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Physics potential of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
D. Attie,
S. Basso,
P. Brun,
N. Bykovskiy,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
M. Cicoli,
M. Civitani,
C. Cogollos,
J. P. Conlon,
D. Costa,
T. Dafni,
R. Daido,
A. V. Derbin,
M. A. Descalle,
K. Desch,
I. S. Dratchnev,
B. Döbrich,
A. Dudarev,
E. Ferrer-Ribas,
I. Fleck,
J. Galán,
G. Galanti
, et al. (66 additional authors not shown)
Abstract:
We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the…
▽ More
We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the strong CP problem, can account for the cold dark matter of the Universe and be responsible for the anomalous cooling observed in a number of stellar systems. At the same time, IAXO will have enough sensitivity to detect lower mass axions invoked to explain: 1) the origin of the anomalous "transparency" of the Universe to gamma-rays, 2) the observed soft X-ray excess from galaxy clusters or 3) some inflationary models. In addition, we review string theory axions with parameters accessible by IAXO and discuss their potential role in cosmology as Dark Matter and Dark Radiation as well as their connections to the above mentioned conundrums.
△ Less
Submitted 6 June, 2019; v1 submitted 19 April, 2019;
originally announced April 2019.
-
First results on dark matter annual modulation from ANAIS-112 experiment
Authors:
J. Amaré,
S. Cebrián,
I. Coarasa,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
ANAIS is a direct detection dark matter experiment aiming at the testing of the DAMA/LIBRA annual modulation result, which standing for about two decades has neither been confirmed nor ruled out by any other experiment in a model independent way. ANAIS-112, consisting of 112.5 kg of sodium iodide crystals, is taking data at the Canfranc Underground Laboratory, Spain, since August 2017. This letter…
▽ More
ANAIS is a direct detection dark matter experiment aiming at the testing of the DAMA/LIBRA annual modulation result, which standing for about two decades has neither been confirmed nor ruled out by any other experiment in a model independent way. ANAIS-112, consisting of 112.5 kg of sodium iodide crystals, is taking data at the Canfranc Underground Laboratory, Spain, since August 2017. This letter presents the annual modulation analysis of 1.5 years of data, amounting to 157.55 kg$\times$y. We focus on the model independent analysis searching for modulation and the validation of our sensitivity prospects. ANAIS-112 data are consistent with the null hypothesis (p-values of 0.65 and 0.16 for [2-6] and [1-6] keV energy regions, respectively). The best fits for the modulation hypothesis are consistent with the absence of modulation ($S_m$=-0.0044$\pm$0.0058 cpd/kg/keV and -0.0015$\pm$0.0063 cpd/kg/keV, respectively). They are in agreement with our estimated sensitivity for the accumulated exposure, supporting our projected goal of reaching a 3$σ$ sensitivity to the DAMA/LIBRA result in 5 years of data taking.
△ Less
Submitted 10 March, 2019;
originally announced March 2019.
-
Background assessment for the TREX Dark Matter experiment
Authors:
J. Castel,
S. Cebrian,
I. Coarasa,
T. Dafni,
J. Galan,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
H. Mirallas,
A. Ortiz de Solorzano,
E. Ruiz-Choliz
Abstract:
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing…
▽ More
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
△ Less
Submitted 22 September, 2019; v1 submitted 11 December, 2018;
originally announced December 2018.
-
ANAIS-112 sensitivity in the search for dark matter annual modulation
Authors:
I. Coarasa,
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search…
▽ More
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. A simple figure of merit has been obtained to compare the different experiments looking for the annual modulation observed by DAMA/LIBRA. We conclude that after 5 years of measurement, ANAIS-112 can detect the annual modulation in the 3$σ$ region compatible with the DAMA/LIBRA result.
△ Less
Submitted 11 March, 2019; v1 submitted 4 December, 2018;
originally announced December 2018.
-
Performance of ANAIS-112 experiment after the first year of data taking
Authors:
J. Amaré,
S. Cebrián,
I. Coarasa,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique than DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint…
▽ More
ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique than DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint of particles with the required properties, although comparison is model dependent. In 2017, ANAIS-112 experiment was installed at the Canfranc Underground Laboratory (LSC), in Spain, and after the commissioning run for calibration and general assessment, ANAIS-112 started data taking in dark matter mode on August 3$^{rd}$, 2017. It consists of nine NaI(Tl) modules, amounting 112.5 kg of mass in total. ANAIS-112 will be able to test the DAMA/LIBRA result with the achieved background and threshold at three sigma level in five years of data taking. Here we report on the experimental apparatus and detector performance after the first year of data taking. Total live time available amounts to 341.72 days, being the corresponding exposure 105.32 kg x yr.
△ Less
Submitted 11 March, 2019; v1 submitted 4 December, 2018;
originally announced December 2018.
-
Analysis of backgrounds for the ANAIS-112 dark matter experiment
Authors:
J. Amare,
S. Cebrian,
I. Coarasa,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
A. Salinas,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of theDAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique, at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix configuration, i…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of theDAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique, at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix configuration, is taking data smoothly in "dark matter search" mode since August, 2017, after a commissioning phase and operation of the first detectors during the last years in various setups. A large effort has been carried out withinANAIS to characterize the background of sodium iodide detectors, before unblinding the data and performing the first annual modulation analysis. Here, the background models developed for all the nine ANAIS-112 detectors are presented. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities independently estimated following several approaches. In the region from 1 to 6 keVee the measured, efficiency corrected background level is 3.58+-0.02 keV-1 kg-1 day-1; NaI crystal bulk contamination is the dominant background source being 210Pb, 40K, 22Na and 3H contributions the most relevant ones. This background level, added to the achieved 1 keVee analysis threshold (thanks to the outstanding light collection and robust filtering procedures developed), allow ANAIS-112 to be sensitive to the modulation amplitude measured by DAMA/LIBRA, and able to explore at three sigma level in 5 years the WIMP parameter region singled out by this experiment.
△ Less
Submitted 28 May, 2019; v1 submitted 4 December, 2018;
originally announced December 2018.
-
The ANAIS-112 experiment at the Canfranc Underground Laboratory
Authors:
J Amare,
S Cebrian,
I Coarasa,
C Cuesta,
E Garcia,
M Martinez,
M A Olivan,
Y Ortigoza,
A Ortiz de Solorzano,
J Puimedon,
A Salinas,
M L Sarsa,
P Villar,
J A Villar
Abstract:
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Several 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. have been operated there during the last years in various set-ups; an outstanding light collection at the level of 15 photoelectrons per keV, which allows triggering at 1 keV of visible energy, has been measured for all…
▽ More
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Several 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. have been operated there during the last years in various set-ups; an outstanding light collection at the level of 15 photoelectrons per keV, which allows triggering at 1 keV of visible energy, has been measured for all of them and a complete characterization of their background has been achieved. In the first months of 2017, the full ANAIS-112 set-up consisting of nine Alpha Spectra detectors with a total mass of 112.5 kg was commissioned at LSC and the first dark matter run started in August, 2017. Here, the latest results on the detectors performance and measured background from the commissioning run will be presented and the sensitivity prospects of the ANAIS-112 experiment will be discussed.
△ Less
Submitted 10 October, 2017;
originally announced October 2017.
-
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Authors:
F Aznar,
J Castel,
S Cebrian,
I Coarasa,
T Dafni,
J Galan,
JG Garza,
FJ Iguaz,
IG Irastorza,
G Luzon,
H Mirallas,
A Ortiz de Solorzano,
E Ruiz-Choliz,
JA Villar
Abstract:
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effe…
▽ More
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.
-
Cosmogenic production of tritium in dark matter detectors
Authors:
J. Amare,
J. Castel,
S. Cebrian,
I. Coarasa,
C. Cuesta,
T. Dafni,
J. Galan,
E. Garcia,
J. G. Garza,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
M. Martinez,
H. Mirallas,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
E. Ruiz-Choliz,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and…
▽ More
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
△ Less
Submitted 24 November, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
Annual modulation of dark matter: The ANAIS-112 case
Authors:
I. Coarasa,
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search…
▽ More
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators under commissioning at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. The analysis is based on the detector response and the background level measured for the first modules operated in Canfranc.
△ Less
Submitted 22 April, 2017;
originally announced April 2017.
-
Light yield determination in large sodium iodide detectors applied in the search for dark matter
Authors:
M. A. Oliván,
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioacti…
▽ More
Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioactive background (at a few counts/keV/kg/day), and high detection mass (at or above the 100 kg scale). One of the most relevant technical issues is the optimization of the crystal intrinsic scintillation light yield and the efficiency of the light collecting system for large mass crystals. In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project large NaI(Tl) crystals from different providers coupled to two photomultiplier tubes (PMTs) have been tested at the Canfranc Underground Laboratory. In this paper we present the estimates of the NaI(Tl) scintillation light collected using full-absorption peaks at very low energy from external and internal sources emitting gammas/electrons, and single-photoelectron events populations selected by using very low energy pulses tails. Outstanding scintillation light collection at the level of 15~photoelectrons/keV can be reported for the final design and provider chosen for ANAIS detectors. Taking into account the Quantum Efficiency of the PMT units used, the intrinsic scintillation light yield in these NaI(Tl) crystals is above 40~photoelectrons/keV for energy depositions in the range from 3 up to 25~keV. This very high light output of ANAIS crystals allows triggering below 1~keV, which is very important in order to increase the sensitivity in the direct detection of dark matter.
△ Less
Submitted 3 March, 2017;
originally announced March 2017.
-
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Authors:
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
S. Cebrián,
C. Cerna,
J. P Cesar,
E. Chauveau,
A. Chopra,
T. Dafní,
S. De Capua,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt
, et al. (71 additional authors not shown)
Abstract:
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been…
▽ More
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.
△ Less
Submitted 7 June, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Assessment of backgrounds of the ANAIS experiment for dark matter direct detection
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
A large effort has been carried out to characterize the background of sodium iodide crystals within the ANAIS (Annual modulation with NaI Scintillators) project. In this paper, the background models developed for three 12.5-kg NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the Canfranc Underground Laboratory are presented together with an evaluation of the background prospect…
▽ More
A large effort has been carried out to characterize the background of sodium iodide crystals within the ANAIS (Annual modulation with NaI Scintillators) project. In this paper, the background models developed for three 12.5-kg NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the Canfranc Underground Laboratory are presented together with an evaluation of the background prospects for the full experiment. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities. At the region of interest, crystal bulk contamination is the dominant background source. Contributions from 210Pb, 40K, 22Na and 3H are the most relevant. Those from 40K and 22Na could be efficiently suppressed thanks to anticoincidence operation in a crystals matrix or inside a Liquid Scintillator Veto (LSV), while that from 210Pb has been reduced by improving crystal production methods and 3H production could be reduced by shielding against cosmic rays during production. Assuming the activities of the last characterized detector, for nine crystals with a total mass of 112.5 kg the expected background rate is 2.5 counts/(keV kg d) in the region from 1 to 4 keV, which could be reduced at 1.4 counts/(keV kg d) by using a LSV.
△ Less
Submitted 22 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
The ANAIS Dark Matter Project: Status and Prospects
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA positive annual modulation signal using the same target and technique at the Canfranc Underground Laboratory (LSC). A first step, named ANAIS-25 (two 12.5 kg NaI(Tl) modules) taking data from December 2012 to February 2015, provided interesting outcomes: very high light collection efficie…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA positive annual modulation signal using the same target and technique at the Canfranc Underground Laboratory (LSC). A first step, named ANAIS-25 (two 12.5 kg NaI(Tl) modules) taking data from December 2012 to February 2015, provided interesting outcomes: very high light collection efficiency, that could allow to lower the analysis energy threshold down to the level of 1 keVee, and a good understanding of the different background components, in particular the cosmogenic activated isotopes in the crystal bulk and other radioactive contaminations of the NaI crystal/powder. But those prototypes clearly pointed to the need for improved crystal radiopurity, in particular for $^{210}$Pb contamination. Since then, improvements in the purification and growing procedures in order to reduce background in the very low energy region have been implemented and a new 12.5 kg module has been constructed and installed between the former two crystals, forming the ANAIS-37 setup. Very preliminary results of this setup evidence the improvement on radiopurity of the new crystal and are presented here. In addition, background simulations and prospects for the full experiment are discussed.
△ Less
Submitted 6 January, 2016;
originally announced January 2016.
-
Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). Along 2016, 112.5 kg of ultra pure NaI(Tl) crystals will be installed at LSC in a 3x3 modules matrix configuration. The ANAIS-25 and ANAIS-37 set-ups have been taking data at the LSC testing the detec…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). Along 2016, 112.5 kg of ultra pure NaI(Tl) crystals will be installed at LSC in a 3x3 modules matrix configuration. The ANAIS-25 and ANAIS-37 set-ups have been taking data at the LSC testing the detector performance, the DAQ and analysis systems, and assessing the background. Main results coming from both set-ups will be summarized in this paper, focusing on the excellent detector performance and background understanding. Prospects for the experiment will be also briefly revised.
△ Less
Submitted 14 December, 2015;
originally announced December 2015.
-
Background model of NaI(Tl) detectors for the ANAIS Dark Matter Project
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
A thorough understanding of the background sources is mandatory in any experiment searching for rare events. The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Two NaI(Tl) crystals of 12.5 kg each produced by Alpha Spectra have been taking data since December 2012. The complete backgrou…
▽ More
A thorough understanding of the background sources is mandatory in any experiment searching for rare events. The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Two NaI(Tl) crystals of 12.5 kg each produced by Alpha Spectra have been taking data since December 2012. The complete background model of these detectors and more precisely in the region of interest will be described. Preliminary background analysis of a new 12.5 kg crystal received at Canfranc in March 2015 will be presented too. Finally, the power of anticoincidence rejection in the region of interest has been analyzed in a 4x 5 12.5 kg detector matrix.
△ Less
Submitted 31 August, 2015;
originally announced August 2015.
-
Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal. A detailed analysis of two NaI(Tl) crystals of 12.5 kg each grown by Alpha Spectra will be shown: effective threshold at 1 keVee is at reach thanks to outstanding light collection and robust PMT noise filtering protocols and the measured background is well understood down to 3 keVee, having quantified K, U and Th content and c…
▽ More
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal. A detailed analysis of two NaI(Tl) crystals of 12.5 kg each grown by Alpha Spectra will be shown: effective threshold at 1 keVee is at reach thanks to outstanding light collection and robust PMT noise filtering protocols and the measured background is well understood down to 3 keVee, having quantified K, U and Th content and cosmogenic activation in the crystals. A new detector was installed in Canfranc in March 2015 together with the two previous modules and preliminary characterization results will be presented. Finally, the status and expected sensitivity of the full experiment with 112 kg will be reviewed.
△ Less
Submitted 28 August, 2015;
originally announced August 2015.
-
Light Collection in the Prototypes of the ANAIS Dark Matter Project
Authors:
Julio Amaré,
Susana Cebrián,
Clara Cuesta,
Eduardo García,
María Martínez,
Miguel A. Oliván,
Ysrael Ortigoza,
Alfonso Ortíz de Solórzano,
Carlos Pobes,
Jorge Puimedón,
María Luisa Sarsa,
José Ángel Villar,
Patricia Villar
Abstract:
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS detectors consist of large NaI crystals coupled to two photomultipliers (PMTs). In this work we present Single Electron Response (SER) data for several units of the Hamamatsu R12669SEL2 PMT model extracted from normal operation data…
▽ More
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS detectors consist of large NaI crystals coupled to two photomultipliers (PMTs). In this work we present Single Electron Response (SER) data for several units of the Hamamatsu R12669SEL2 PMT model extracted from normal operation data of ANAIS underground prototypes and we compare them with PMT SER characterization previously done at surface lab before coupling them to NaI crystal. Moreover, total light collection for different ANAIS prototypes has been calculated, producing an excellent average result of 15 phe/keV, which has a good impact in both energy resolution and threshold.
△ Less
Submitted 25 August, 2015;
originally announced August 2015.
-
Background analysis and status of the ANAIS dark matter project
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
C. Ginestra,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The compa…
▽ More
ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for Th-232 and U-238 chains, but a Pb-210 contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Radon and material radiopurity assessment for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
E. D. C. Freitas,
L. M. P. Fernandes,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is un…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, hel** in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Production and relevance of cosmogenic radionuclides in NaI(Tl) crystals
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
C. Ginestra,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few activation data were available. We present results from two 12.5 kg NaI(Tl) detectors, developed within the ANAIS project and installed at the Canfranc Underground La…
▽ More
The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few activation data were available. We present results from two 12.5 kg NaI(Tl) detectors, developed within the ANAIS project and installed at the Canfranc Underground Laboratory. The prompt data taking starting made possible a reliable quantification of production of some I, Te and Na isotopes with half-lives larger than ten days. Initial activities underground were measured and then production rates at sea level were estimated following the history of detectors; a comparison of these rates with calculations using typical cosmic neutron flux at sea level and a selected description of excitation functions was also carried out. After including the contribution from the identified cosmogenic products in the detector background model, we found that the presence of 3H in the crystal bulk would help to fit much better our background model and experimental data. We have analyzed the cosmogenic production of 3H in NaI, and although precise quantification has not been attempted, we can conclude that it could imply a very relevant contribution to the total background below 15 keV in NaI detectors.
△ Less
Submitted 22 May, 2015;
originally announced May 2015.