-
Deep Few-view High-resolution Photon-counting Extremity CT at Halved Dose for a Clinical Trial
Authors:
Mengzhou Li,
Chuang Niu,
Ge Wang,
Maya R Amma,
Krishna M Chapagain,
Stefan Gabrielson,
Andrew Li,
Kevin Jonker,
Niels de Ruiter,
Jennifer A Clark,
Phil Butler,
Anthony Butler,
Hengyong Yu
Abstract:
The latest X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging for tissue characterization and material decomposition. However, both radiation dose and imaging speed need improvement for contrast-enhanced and other studies. Despite the success of deep learning methods for 2D few-view reconstruction, applying them to HR volumetric reconstr…
▽ More
The latest X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging for tissue characterization and material decomposition. However, both radiation dose and imaging speed need improvement for contrast-enhanced and other studies. Despite the success of deep learning methods for 2D few-view reconstruction, applying them to HR volumetric reconstruction of extremity scans for clinical diagnosis has been limited due to GPU memory constraints, training data scarcity, and domain gap issues. In this paper, we propose a deep learning-based approach for PCCT image reconstruction at halved dose and doubled speed in a New Zealand clinical trial. Particularly, we present a patch-based volumetric refinement network to alleviate the GPU memory limitation, train network with synthetic data, and use model-based iterative refinement to bridge the gap between synthetic and real-world data. The simulation and phantom experiments demonstrate consistently improved results under different acquisition conditions on both in- and off-domain structures using a fixed network. The image quality of 8 patients from the clinical trial are evaluated by three radiologists in comparison with the standard image reconstruction with a full-view dataset. It is shown that our proposed approach is essentially identical to or better than the clinical benchmark in terms of diagnostic image quality scores. Our approach has a great potential to improve the safety and efficiency of PCCT without compromising image quality.
△ Less
Submitted 18 March, 2024;
originally announced March 2024.
-
MARS-MD: rejection based image domain material decomposition
Authors:
C. J. Bateman,
D. Knight,
B. Brandwacht,
J. Mc Mahon,
J. Healy,
R. Panta,
R. Aamir,
K. Rajendran,
M. Moghiseh,
M. Ramyar,
D. Rundle,
J. Bennett,
N. de Ruiter,
D. Smithies,
S. T. Bell,
R. Doesburg,
A. Chernoglazov,
V. B. H. Mandalika,
M. Walsh,
M. Shamshad,
M. Anjomrouz,
A. Atharifard,
L. Vanden Broeke,
S. Bheesette,
T. Kirkbride
, et al. (6 additional authors not shown)
Abstract:
This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problem…
▽ More
This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problems, each containing fewer materials; (2) solving each sub-problem; and (3) applying rejection criteria to eliminate all but one sub-problem's solution. An advantage of this process is that different constraints can be applied to each sub-problem if necessary. In addition, the result of this process is that solutions will be sparse in the material domain, which reduces crossover of signal between material images. Two algorithms based on this process are presented: the Segmentation variant, which uses segmented material classes to define each sub-problem; and the Angular Rejection variant, which defines the rejection criteria using the angle between reconstructed attenuation vectors.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
The Hidden K-edge Signal in K-edge Imaging
Authors:
Christopher J. Bateman,
Kishore Rajendran,
Niels J. A. de Ruiter,
Anthony P. Butler,
Philip H. Butler,
Peter F. Renaud
Abstract:
K-edge imaging is commonly used for viewing contrast pharmaceuticals in a variety of multi-energy x-ray imaging techniques, ranging from dual-energy and spectral computed tomography to fluoroscopy. When looking for the K-edge signal of a specific contrast, by taking measurements either side of the K-edge, it is found that the K-edge is not always observable for low concentrations. We have also obs…
▽ More
K-edge imaging is commonly used for viewing contrast pharmaceuticals in a variety of multi-energy x-ray imaging techniques, ranging from dual-energy and spectral computed tomography to fluoroscopy. When looking for the K-edge signal of a specific contrast, by taking measurements either side of the K-edge, it is found that the K-edge is not always observable for low concentrations. We have also observed that the ability to see the K-edge is unit dependent - a K-edge that is not observable in computed tomography (CT) reconstructed linear attenuation units can often be made visible by converting to Hounsfield units.
This paper presents an investigation of this K-edge hiding phenomenon. We conclude that if a multi-energy x-ray measurement of any K-edge material contains a signal of any other material, then there will be a positive concentration of that K-edge material below which its K-edge cannot be observed without extracting the K-edge signal through means of basis decomposition. Mathematical descriptions of this limiting minimum concentration is provided in three cases - multi-energy radiographic projection images; and reconstructed multi-energy CT images for both linear attenuation and Hounsfield units. Two important properties of this limiting concentration are provided: the minimum concentration for Hounsfield units is always strictly less than the minimum concentration for linear attenuation; and the minimum concentration for radiographic projections will typically be much larger than the minimum concentration for reconstructed linear attenuation. Finally experimental observation of this phenomenon is presented using data collected by the MARS spectral CT scanner equipped with a CdTe Medipix-3RX camera operating in charge-summing mode, where it is also shown that the K-edge can be recovered through basis decomposition.
△ Less
Submitted 13 June, 2015;
originally announced June 2015.
-
Reducing beam hardening effects and metal artefacts using Medipix3RX: With applications from biomaterial science
Authors:
K. Rajendran,
M. F. Walsh,
N. J. A. de Ruiter,
A. I. Chernoglazov,
R. K. Panta,
A. P. H. Butler,
P. H. Butler,
S. T. Bell,
N. G. Anderson,
T. B. F. Woodfield,
S. J. Tredinnick,
J. L. Healy,
C. J. Bateman,
R. Aamir,
R. M. N. Doesburg,
P. F. Renaud,
S. P. Gieseg,
D. J. Smithies,
J. L. Mohr,
V. B. H. Mandalika,
A. M. T. Opie,
N. J. Cook,
J. P. Ronaldson,
S. J. Nik,
A. Atharifard
, et al. (6 additional authors not shown)
Abstract:
This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routi…
▽ More
This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routine. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. Narrow high energy acquisition using the photon-processing detector revealed substantial reduction in beam hardening effects and metal artefacts.
△ Less
Submitted 20 November, 2013;
originally announced November 2013.
-
MARS spectral molecular imaging of lamb tissue: data collection and image analysis
Authors:
R Aamir,
A Chernoglazov,
C J Bateman,
A P H Butler,
P H Butler,
N G Anderson,
S T Bell,
R K Panta,
J L Healy,
J L Mohr,
K Rajendran,
M F Walsh,
N de Ruiter,
S P Gieseg,
T Woodfield,
P F Renaud,
L Brooke,
S Abdul-Majid,
M Clyne,
R Glendenning,
P J Bones,
M Billinghurst,
C Bartneck,
H Mandalika,
R Grasset
, et al. (13 additional authors not shown)
Abstract:
Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectros…
▽ More
Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectroscopic photon-processing detector, to discriminate fat, calcium, and water in tissue. We present data collected from a sample of lamb meat including bone as an illustrative example of human tissue imaging. The data is analyzed using our 3D Algebraic Reconstruction Algorithm (MARS-ART) and by material decomposition based on a constrained linear least squares algorithm. The results presented here clearly show the quantification of lipid-like, water-like and bone-like components of tissue. However, it is also clear to us that better algorithms could extract more information of clinical interest from our data. Because we are one of the first to present data from multi-energy photon-processing small animal CT systems, we make the raw, partial and fully processed data available with the intention that others can analyze it using their familiar routines. The raw, partially processed and fully processed data of lamb tissue along with the phantom calibration data can be found at [http://hdl.handle.net/10092/8531].
△ Less
Submitted 23 January, 2014; v1 submitted 18 November, 2013;
originally announced November 2013.