A Segmented Total Energy Detector (sTED) optimized for $(n,γ)$ cross-section measurements at n_TOF EAR2
Authors:
V. Alcayne,
D. Cano-Ott,
J. Garcia,
E. Gonzalez-Romero,
T. Martinez,
A. Perez de Rada,
J. Plaza,
A. Sanchez-Caballero,
J. Balibrea-Correa,
C. Domingo-Pardo,
J. Lerendegui-Marco,
A. Casanovas,
F. Calvino,
O. Aberle,
the n_TOF collaboration
Abstract:
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Expe…
▽ More
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Experimental ARea 1 (EAR1) of $8\times10^5$ neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detectors response, by reducing the active volume per module and by using a photomultiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to $γ$-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.
△ Less
Submitted 14 March, 2024;
originally announced March 2024.
-
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
Authors:
J. Balibrea Correa,
J. Lerendegui-Marco,
V. Babiano-Suarez,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
A. Pérez de Rada,
J. Plaza del Olmo,
A. Sánchez-Caballero,
A. Casanovas,
F. Calviño,
S. Valenta,
O. Aberle,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes
, et al. (109 additional authors not shown)
Abstract:
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects…
▽ More
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
G Garcia,
E Nácher,
J L Tain,
V Alcayne,
O Alonso-Sañudo,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
J Gómez-Camacho,
E M González-Romero
, et al. (18 additional authors not shown)
Abstract:
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron…
▽ More
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron yields from 27Al(alpha, n)30P.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
miniBELEN: a modular neutron counter for (alpha,n) reactions
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
E Nácher,
J L Tain,
V Alcayne,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
G García,
J Gómez-Camacho,
E M González-Romero,
C Guerrero
, et al. (16 additional authors not shown)
Abstract:
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming…
▽ More
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (alpha,n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(alpha,n)30P reaction is also presented.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility
Authors:
J. Balibrea-Correa,
V. Babiano-Suarez,
J. Lerendegui-Marco,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
J. Plaza,
A. Sánchez-Caballero,
F. Calviño,
A. Casanovas,
C. Guerrero,
S. Heinitz,
U. Köster,
E. A. Maugeri,
R. Dressler,
D. Schumann,
I. Mönch,
S. Cristallo,
C. Lederer-Woods,
O. Aberle
, et al. (112 additional authors not shown)
Abstract:
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along di…
▽ More
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.
△ Less
Submitted 20 February, 2023; v1 submitted 26 January, 2023;
originally announced January 2023.
-
The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements
Authors:
N. Patronis,
A. Mengoni,
N. Colonna,
M. Cecchetto,
C. Domingo-Pardo,
O. Aberle,
J. Lerendegui-Marco,
G. Gervino,
M. E. Stamati,
S. Goula,
A. P. Bernardes,
M. Mastromarco,
A. Manna,
R. Vlastou,
C. Massimi,
M. Calviani,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea,
C. Beltrami,
S. Bennett
, et al. (108 additional authors not shown)
Abstract:
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to th…
▽ More
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
Authors:
C. Domingo-Pardo,
V. Babiano-Suarez,
J. Balibrea-Correa,
L. Caballero,
I. Ladarescu,
J. Lerendegui-Marco,
J. L. Tain,
A. Tarifeño-Saldivia,
O. Aberle,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes,
E. Berthoumieux,
M. Boromiza,
D. Bosnar,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
A. Casanovas
, et al. (114 additional authors not shown)
Abstract:
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also prese…
▽ More
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Characterization of a CLYC detector for underground experiments
Authors:
T. Martinez,
A. Pérez de Rada,
D. Cano-Ott,
R. Santorelli,
I. Bandac,
P. Garcia Abia,
A. R. Garcia,
A. Ianni,
B. Montes,
L. Romero,
D. Villamarin
Abstract:
Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $γ$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability.…
▽ More
Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $γ$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability. In this work we report on a wide series measurements performed with a commercial 2"x2" CLYC crystal. Good energy and timing resolution values of 4.7% (@ 662 keV) and 1340 ps (FWHM), respectively, were achieved, and a neutron/$γ$ separation figure of merit value of 4.2 was obtained. A dedicated measurement for investigating the intrinsic background of the detector was performed at the Laboratorio Subterráneo de Canfranc (Spain). It evidenced a sizeable contamination in the detector materials which poses limits in the use of CLYC in low background experiments. In addition, detailed Monte Carlo simulations with the GEANT4 toolkit were performed for modeling the response function of the CLYC detector to gamma-rays. An excellent agreement with the experimental data has been achieved.
△ Less
Submitted 6 October, 2017;
originally announced October 2017.