-
The New Small Wheel electronics
Authors:
G. Iakovidis,
L. Levinson,
Y. Afik,
C. Alexa,
T. Alexopoulos,
J. Ameel,
D. Amidei,
D. Antrim,
A. Badea,
C. Bakalis,
H. Boterenbrood,
R. S. Brener,
S. Chan,
J. Chapman,
G. Chatzianastasiou,
H. Chen,
M. C. Chu,
R. M. Coliban,
T. Costa de Paiva,
G. de Geronimo,
R. Edgar,
N. Felt,
S. Francescato,
M. Franklin,
T. Geralis
, et al. (77 additional authors not shown)
Abstract:
The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector te…
▽ More
The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the "small" Thin Gap Chambers, with a total of 2.45 Million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm$^{2}$ at the expected HL-LHC luminosity of $\mathcal{L}$=7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.
△ Less
Submitted 25 May, 2023; v1 submitted 22 March, 2023;
originally announced March 2023.
-
The design and performance of the XL-Calibur anticoincidence shield
Authors:
N. K. Iyer,
M. Kiss,
M. Pearce,
T. -A. Stana,
H. Awaki,
R. G. Bose,
A. Dasgupta,
G. De Geronimo,
E. Gau,
T. Hakamata,
M. Ishida,
K. Ishiwata,
W. Kamogawa,
F. Kislat,
T. Kitaguchi,
H. Krawczynski,
L. Lisalda,
Y. Maeda,
H. Matsumoto,
A. Miyamoto,
T. Miyazawa,
T. Mizuno,
B. F. Rauch,
N. Rodriguez Cavero,
N. Sakamoto
, et al. (9 additional authors not shown)
Abstract:
The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincide…
▽ More
The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ~0.5 Hz (20-40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight
Authors:
Quincy Abarr,
Banafsheh Beheshtipour,
Matthias Beilicke,
Richard Bose,
Dana Braun,
Gianluigi de Geronimo,
Paul Dowkontt,
Manel Errando,
Thomas Gadson,
Victor Guarino,
Scott Heatwole,
Md. Arman Hossen,
Nirmal K. Iyer,
Fabian Kislat,
Mózsi Kiss,
Takao Kitaguchi,
Henric Krawczynski,
R. James Lanzi,
Shaorui Li,
Lindsey Lisalda,
Takashi Okajima,
Mark Pearce,
Zachary Peterson,
Logan Press,
Brian Rauch
, et al. (6 additional authors not shown)
Abstract:
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launche…
▽ More
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.
△ Less
Submitted 20 April, 2022;
originally announced April 2022.
-
XL-Calibur -- a second-generation balloon-borne hard X-ray polarimetry mission
Authors:
Q. Abarr,
H. Awaki,
M. G. Baring,
R. Bose,
G. De Geronimo,
P. Dowkontt,
M. Errando,
V. Guarino,
K. Hattori,
K. Hayashida,
F. Imazato,
M. Ishida,
N. K. Iyer,
F. Kislat,
M. Kiss,
T. Kitaguchi,
H. Krawczynski,
L. Lisalda,
H. Matake,
Y. Maeda,
H. Matsumoto,
T. Mineta,
T. Miyazawa,
T. Mizuno,
T. Okajima
, et al. (16 additional authors not shown)
Abstract:
XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301-2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprisin…
▽ More
XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301-2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprising a beryllium rod surrounded by Cadmium Zinc Telluride (CZT) detectors. The polarimeter is housed in an anticoincidence shield to mitigate background from particles present in the stratosphere. The mirror and polarimeter-shield assembly are mounted at opposite ends of a 12 m long lightweight truss, which is pointed with arcsecond precision by WASP - the Wallops Arc Second Pointer. The XL-Calibur mission will achieve a substantially improved sensitivity over X-Calibur by using a larger effective area X-ray mirror, reducing background through thinner CZT detectors, and improved anticoincidence shielding. When observing a 1 Crab source for $t_{\rm day}$ days, the Minimum Detectable Polarisation (at 99% confidence level) is $\sim$2$\%\cdot t_{\rm day}^{-1/2}$. The energy resolution at 40 keV is $\sim$5.9 keV. The aim of this paper is to describe the design and performance of the XL-Calibur mission, as well as the foreseen science programme.
△ Less
Submitted 20 October, 2020;
originally announced October 2020.
-
Measuring nuclear reaction cross sections to extract information on neutrinoless double beta decay
Authors:
M. Cavallaro,
F. Cappuzzello,
C. Agodi,
L. Acosta,
N. Auerbach,
J. Bellone,
R. Bijker,
D. Bonanno,
D. Bongiovanni,
T. Borello-Lewin,
I. Boztosun,
V. Branchina,
M. P. Bussa,
S. Calabrese,
L. Calabretta,
A. Calanna,
D. Calvo,
D. Carbone,
E. R. Chávez Lomelí,
A. Coban,
M. Colonna,
G. D'Agostino,
G. De Geronimo,
F. Delaunay,
N. Deshmukh
, et al. (50 additional authors not shown)
Abstract:
Neutrinoless double beta decay (0v\b{eta}\b{eta}) is considered the best potential resource to access the absolute neutrino mass scale. Moreover, if observed, it will signal that neutrinos are their own anti-particles (Majorana particles). Presently, this physics case is one of the most important research "beyond Standard Model" and might guide the way towards a Grand Unified Theory of fundamental…
▽ More
Neutrinoless double beta decay (0v\b{eta}\b{eta}) is considered the best potential resource to access the absolute neutrino mass scale. Moreover, if observed, it will signal that neutrinos are their own anti-particles (Majorana particles). Presently, this physics case is one of the most important research "beyond Standard Model" and might guide the way towards a Grand Unified Theory of fundamental interactions.
Since the 0v\b{eta}\b{eta} decay process involves nuclei, its analysis necessarily implies nuclear structure issues. In the NURE project, supported by a Starting Grant of the European Research Council (ERC), nuclear reactions of double charge-exchange (DCE) are used as a tool to extract information on the 0v\b{eta}\b{eta} Nuclear Matrix Elements. In DCE reactions and \b{eta}\b{eta} decay indeed the initial and final nuclear states are the same and the transition operators have similar structure. Thus the measurement of the DCE absolute cross-sections can give crucial information on \b{eta}\b{eta} matrix elements. In a wider view, the NUMEN international collaboration plans a major upgrade of the INFN-LNS facilities in the next years in order to increase the experimental production of nuclei of at least two orders of magnitude, thus making feasible a systematic study of all the cases of interest as candidates for 0v\b{eta}\b{eta}.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors
Authors:
D. L. Adams,
M. Baird,
G. Barr,
N. Barros,
A. Blake,
E. Blaufuss,
A. Booth,
D. Brailsford,
N. Buchanan,
B. Carls,
H. Chen,
M. Convery,
G. De Geronimo,
T. Dealtry,
R. Dharmapalan,
Z. Djurcic,
J. Fowler,
S. Glavin,
R. A. Gomes,
M. C. Goodman,
M. Graham,
L. Greenler,
A. Hahn,
J. Hartnell,
R. Herbst
, et al. (49 additional authors not shown)
Abstract:
Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for "far detectors" of the next generation of neutrino oscill…
▽ More
Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for "far detectors" of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.
△ Less
Submitted 2 March, 2020; v1 submitted 18 December, 2019;
originally announced December 2019.
-
Development of a High Rate Front-end ASIC for X-ray Spectroscopy and Diffraction Applications
Authors:
Emerson Vernon,
Gianluigi De Geronimo,
Jonathan Baldwin,
Wei Chen,
Jack Fried,
Gabriele Giacomini,
Anthony Kuczewski,
John Kuczewski,
Joe Mead,
Antonino Miceli,
John S. Okasinski,
Don Pinelli,
Orlando Quaranta,
Abdul K. Rumaiz,
Peter Siddons,
Graham Smith,
Milutin Stanacevic,
Russell Woods
Abstract:
We developed a new front-end application specific integrated circuit (ASIC) for the upgrade of the Maia x-ray microprobe. The ASIC instruments 32 configurable front-end channels that perform either positive or negative charge amplification, pulse sha**, peak amplitude and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1 $μ$s peaking time and a temperature of 248 K, an…
▽ More
We developed a new front-end application specific integrated circuit (ASIC) for the upgrade of the Maia x-ray microprobe. The ASIC instruments 32 configurable front-end channels that perform either positive or negative charge amplification, pulse sha**, peak amplitude and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1 $μ$s peaking time and a temperature of 248 K, an electronic resolution of 13- and 10 electrons rms was measured with and without a SDD sensor respectively. A spectral resolution of 170 eV FWHM at 5.9 keV was obtained with an $^{55}$Fe source. The channel linearity was better than $\pm$ 1 % with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250 nm process with a footprint of 6.3 mm x 3.9 mm and dissipates 167 mW of static power.
△ Less
Submitted 13 May, 2019;
originally announced May 2019.
-
Front-end ASIC for Spectroscopic Readout of Virtual Frisch-Grid CZT Bar Sensors
Authors:
Emerson Vernon,
Gianluigi De Geronimo,
Aleksey Bolotnikov,
Milutin Stanacevic,
Jack Fried,
Luis Ocampo Giraldo,
Kevin Wolniewicz,
Kim Ackley,
Cynthia Salwen,
John Triolo,
Don Pinelli,
Kenny Luong
Abstract:
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at th…
▽ More
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order sha**, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than $\pm$ 1 % with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 x 4 array of 6 mm x 6 mm x 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of $\approx$ 270 rms $e^{-}$ for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8 % FWHM at 238 keV and 0.9 % FWHM at 662 keV.
△ Less
Submitted 2 April, 2019;
originally announced April 2019.
-
The NUMEN project: NUclear Matrix Elements for Neutrinoless double beta decay
Authors:
F. Cappuzzello,
C. Agodi,
M. Cavallaro,
D. Carbone,
S. Tudisco,
D. Lo Presti,
J. R. B. Oliveira,
P. Finocchiaro,
M. Colonna,
D. Rifuggiato,
L. Calabretta,
D. Calvo,
L. Pandola,
L. Acosta,
N. Auerbach,
J. Bellone,
R. Bijker,
D. Bonanno,
D. Bongiovanni,
T. Borello-Lewin,
I. Boztosun,
O. Brunasso,
S. Burrello,
S. Calabrese,
A. Calanna
, et al. (46 additional authors not shown)
Abstract:
The article describes the main achievements of the NUMEN project together with an updated and detailed overview of the related R&D activities and theoretical developments. NUMEN proposes an innovative technique to access the nuclear matrix elements entering the expression of the lifetime of the double beta decay by cross section measurements of heavy-ion induced Double Charge Exchange (DCE) reacti…
▽ More
The article describes the main achievements of the NUMEN project together with an updated and detailed overview of the related R&D activities and theoretical developments. NUMEN proposes an innovative technique to access the nuclear matrix elements entering the expression of the lifetime of the double beta decay by cross section measurements of heavy-ion induced Double Charge Exchange (DCE) reactions. Despite the two processes, namely neutrinoless double beta decay and DCE reactions, are triggered by the weak and strong interaction respectively, important analogies are suggested. The basic point is the coincidence of the initial and final state many-body wave-functions in the two types of processes and the formal similarity of the transition operators. First experimental results obtained at the INFN-LNS laboratory for the 40Ca(18O,18Ne)40Ar reaction at 270 MeV, give encouraging indication on the capability of the proposed technique to access relevant quantitative information. The two major aspects for this project are the K800 Superconducting Cyclotron and MAGNEX spectrometer. The former is used for the acceleration of the required high resolution and low emittance heavy ion beams and the latter is the large acceptance magnetic spectrometer for the detection of the ejectiles. The use of the high-order trajectory reconstruction technique, implemented in MAGNEX, allows to reach the experimental resolution and sensitivity required for the accurate measurement of the DCE cross sections at forward angles. However, the tiny values of such cross sections and the resolution requirements demand beam intensities much larger than manageable with the present facility. The on-going upgrade of the INFN-LNS facilities in this perspective is part of the NUMEN project and will be discussed in the article.
△ Less
Submitted 21 November, 2018;
originally announced November 2018.
-
Noise Characterization and Filtering in the MicroBooNE Liquid Argon TPC
Authors:
MicroBooNE collaboration,
R. Acciarri,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
L. Bagby,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
M. Bishai,
A. Blake,
T. Bolton,
B. Bullard,
L. Camilleri,
D. Caratelli,
B. Carls,
R. Castillo Fernandez,
F. Cavanna,
H. Chen,
E. Church
, et al. (130 additional authors not shown)
Abstract:
The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction planes. This paper describes the characteristics and mitigation of the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase LArTPC comprises t…
▽ More
The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction planes. This paper describes the characteristics and mitigation of the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase LArTPC comprises two induction planes and one collection sense wire plane with a total of 8256 wires. Current induced on each TPC wire is amplified and shaped by custom low-power, low-noise ASICs immersed in the liquid argon. The digitization of the signal waveform occurs outside the cryostat. Using data from the first year of MicroBooNE operations, several excess noise sources in the TPC were identified and mitigated. The residual equivalent noise charge (ENC) after noise filtering varies with wire length and is found to be below 400 electrons for the longest wires (4.7 m). The response is consistent with the cold electronics design expectations and is found to be stable with time and uniform over the functioning channels. This noise level is significantly lower than previous experiments utilizing warm front-end electronics.
△ Less
Submitted 20 May, 2017;
originally announced May 2017.
-
Design of the telescope truss and gondola for the balloon-borne X-ray polarimeter X-Calibur
Authors:
Fabian Kislat,
Banafsheh Beheshtipour,
Paul Dowkontt,
Victor Guarino,
R. James Lanzi,
Takashi Okajima,
Dana Braun,
Scott Cannon,
Gialuigi De Geronimo,
Scott Heatwole,
Janie Hoorman,
Shaorui Li,
Hideyuki Mori,
Christopher M. Shreves,
David Stuchlik,
Henric Krawczynski
Abstract:
X-ray polarimetry has seen a growing interest in recent years. Improvements in detector technology and focusing X-ray optics now enable sensitive astrophysical X-ray polarization measurements. These measurements will provide new insights into the processes at work in accreting black holes, the emission of X-rays from neutron stars and magnetars, and the structure of AGN jets. X-Calibur is a balloo…
▽ More
X-ray polarimetry has seen a growing interest in recent years. Improvements in detector technology and focusing X-ray optics now enable sensitive astrophysical X-ray polarization measurements. These measurements will provide new insights into the processes at work in accreting black holes, the emission of X-rays from neutron stars and magnetars, and the structure of AGN jets. X-Calibur is a balloon-borne hard X-ray scattering polarimeter. An X-ray mirror with a focal length of 8 m focuses X-rays onto the detector, which consists of a plastic scattering element surrounded by Cadmium-Zinc-Telluride detectors, which absorb and record the scattered X-rays. Since X-rays preferentially scatter perpendicular to their polarization direction, the polarization properties of an X-ray beam can be inferred from the azimuthal distribution of scattered X-rays. A close alignment of the X-ray focal spot with the center of the detector is required in order to reduce systematic uncertainties and to maintain a high photon detection efficiency. This places stringent requirements on the mechanical and thermal stability of the telescope structure. During the flight on a stratospheric balloon, X-Calibur makes use of the Wallops Arc-Second Pointer (WASP) to point the telescope at astrophysical sources. In this paper, we describe the design, construction, and test of the telescope structure, as well as its performance during a 25-hour flight from Ft. Sumner, New Mexico. The carbon fiber-aluminum composite structure met the requirements set by X-Calibur and its design can easily be adapted for other types of experiments, such as X-ray imaging or spectroscopic telescopes.
△ Less
Submitted 17 January, 2017;
originally announced January 2017.
-
A Proposal for a Three Detector Short-Baseline Neutrino Oscillation Program in the Fermilab Booster Neutrino Beam
Authors:
R. Acciarri,
C. Adams,
R. An,
C. Andreopoulos,
A. M. Ankowski,
M. Antonello,
J. Asaadi,
W. Badgett,
L. Bagby,
B. Baibussinov,
B. Baller,
G. Barr,
N. Barros,
M. Bass,
V. Bellini,
P. Benetti,
S. Bertolucci,
K. Biery,
H. Bilokon,
M. Bishai,
A. Bitadze,
A. Blake,
F. Boffelli,
T. Bolton,
M. Bonesini
, et al. (199 additional authors not shown)
Abstract:
A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-sca…
▽ More
A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-scale through both appearance and disappearance oscillation channels. Using data sets of 6.6e20 protons on target (P.O.T.) in the LAr1-ND and ICARUS T600 detectors plus 13.2e20 P.O.T. in the MicroBooNE detector, we estimate that a search for muon neutrino to electron neutrino appearance can be performed with ~5 sigma sensitivity for the LSND allowed (99% C.L.) parameter region. In this proposal for the SBN Program, we describe the physics analysis, the conceptual design of the LAr1-ND detector, the design and refurbishment of the T600 detector, the necessary infrastructure required to execute the program, and a possible reconfiguration of the BNB target and horn system to improve its performance for oscillation searches.
△ Less
Submitted 4 March, 2015;
originally announced March 2015.
-
Optimization of <= 200 um pitch CZT detectors for future high-resolution X-ray instrumentation in astrophysics
Authors:
Anna Zajczyk,
Marie Draper,
Paul Dowkontt,
Qingzhen Guo,
Fabian Kislat,
Henric Krawczynski,
Gianluigi De Geronimo,
Shaorui Li,
Matthias Beilicke
Abstract:
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about…
▽ More
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of <= 250um. Additional detector requirements include a low energy threshold of less than 5keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this contribution, we report on our R&D studies with the goal to optimise small-pixel Cadmium Zinc Telluride and Cadmium Telluride detectors.
△ Less
Submitted 14 January, 2015;
originally announced January 2015.
-
Design and Performance of the X-ray polarimeter X-Calibur
Authors:
Matthias Beilicke,
F. Kislat,
A. Zajczyk,
Q. Guo,
R. Endsley,
M. Stork,
R. Cowsik,
P. Dowkontt,
S. Barthelmy,
T. Hams,
T. Okajima,
M. Sasaki,
B. Zeiger,
G. De Geronimo,
M. G. Baring,
H. Krawczynski
Abstract:
X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope. X-Calibur combines a low-Z…
▽ More
X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope. X-Calibur combines a low-Z scatterer with a CZT detector assembly to measure the polarization of 20-80keV X-rays making use of the fact that polarized photons scatter preferentially perpendicular to the electric field orientation. X-Calibur achieves a high detection efficiency of ~80%. The X-Calibur detector assembly is completed, tested, and fully calibrated. The response to a polarized X-ray beam was measured successfully at the Cornell High Energy Synchrotron Source. This paper describes the design, calibration and performance of the X-Calibur polarimeter. In principle, a similar space-borne scattering polarimeter could operate over the broader 2-100keV energy band.
△ Less
Submitted 19 December, 2014;
originally announced December 2014.
-
The Long-Baseline Neutrino Experiment: Exploring Fundamental Symmetries of the Universe
Authors:
LBNE Collaboration,
Corey Adams,
David Adams,
Tarek Akiri,
Tyler Alion,
Kris Anderson,
Costas Andreopoulos,
Mike Andrews,
Ioana Anghel,
João Carlos Costa dos Anjos,
Maddalena Antonello,
Enrique Arrieta-Diaz,
Marina Artuso,
Jonathan Asaadi,
Xinhua Bai,
Bagdat Baibussinov,
Michael Baird,
Baha Balantekin,
Bruce Baller,
Brian Baptista,
D'Ann Barker,
Gary Barker,
William A. Barletta,
Giles Barr,
Larry Bartoszek
, et al. (461 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early Universe, the dynamics of the supernova bursts that produced the heavy elements necessary for life and whether protons eventually decay --- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our Universe, its current state and its eventual fate. The Long-Baseline Neutrino Exp…
▽ More
The preponderance of matter over antimatter in the early Universe, the dynamics of the supernova bursts that produced the heavy elements necessary for life and whether protons eventually decay --- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our Universe, its current state and its eventual fate. The Long-Baseline Neutrino Experiment (LBNE) represents an extensively developed plan for a world-class experiment dedicated to addressing these questions. LBNE is conceived around three central components: (1) a new, high-intensity neutrino source generated from a megawatt-class proton accelerator at Fermi National Accelerator Laboratory, (2) a near neutrino detector just downstream of the source, and (3) a massive liquid argon time-projection chamber deployed as a far detector deep underground at the Sanford Underground Research Facility. This facility, located at the site of the former Homestake Mine in Lead, South Dakota, is approximately 1,300 km from the neutrino source at Fermilab -- a distance (baseline) that delivers optimal sensitivity to neutrino charge-parity symmetry violation and mass ordering effects. This ambitious yet cost-effective design incorporates scalability and flexibility and can accommodate a variety of upgrades and contributions. With its exceptional combination of experimental configuration, technical capabilities, and potential for transformative discoveries, LBNE promises to be a vital facility for the field of particle physics worldwide, providing physicists from around the globe with opportunities to collaborate in a twenty to thirty year program of exciting science. In this document we provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess.
△ Less
Submitted 22 April, 2014; v1 submitted 28 July, 2013;
originally announced July 2013.
-
Integrated Circuit Design in US High-Energy Physics
Authors:
G. De Geronimo,
D. Christian,
C. Bebek,
M. Garcia-Sciveres,
H. Von der Lippe,
G. Haller,
A. A. Grillo,
M. Newcomer
Abstract:
This whitepaper summarizes the status, plans, and challenges in the area of integrated circuit design in the United States for future High Energy Physics (HEP) experiments. It has been submitted to CPAD (Coordinating Panel for Advanced Detectors) and the HEP Community Summer Study 2013(Snowmass on the Mississippi) held in Minnesota July 29 to August 6, 2013. A workshop titled: US Workshop on IC De…
▽ More
This whitepaper summarizes the status, plans, and challenges in the area of integrated circuit design in the United States for future High Energy Physics (HEP) experiments. It has been submitted to CPAD (Coordinating Panel for Advanced Detectors) and the HEP Community Summer Study 2013(Snowmass on the Mississippi) held in Minnesota July 29 to August 6, 2013. A workshop titled: US Workshop on IC Design for High Energy Physics, HEPIC2013 was held May 30 to June 1, 2013 at Lawrence Berkeley National Laboratory (LBNL). A draft of the whitepaper was distributed to the attendees before the workshop, the content was discussed at the meeting, and this document is the resulting final product. The scope of the whitepaper includes the following topics: Needs for IC technologies to enable future experiments in the three HEP frontiers Energy, Cosmic and Intensity Frontiers; Challenges in the different technology and circuit design areas and the related R&D needs; Motivation for using different fabrication technologies; Outlook of future technologies including 2.5D and 3D; Survey of ICs used in current experiments and ICs targeted for approved or proposed experiments; IC design at US institutes and recommendations for collaboration in the future.
△ Less
Submitted 15 July, 2013; v1 submitted 10 July, 2013;
originally announced July 2013.
-
Study of Thick CZT Detectors for X-ray and Gamma-Ray Astronomy
Authors:
Qiang Li,
M. Beilicke,
Kuen Lee,
Alfred Garson III,
Q. Guo,
Jerrad Martin,
Y. Yin,
P. Dowkontt,
G. De Geronimo,
I. Jung,
H. Krawczynski
Abstract:
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and γ-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT detectors for the detection of 15-150 keV X-rays from Gamma-Ray Bursts. We report on the systematic tests of thicker (\geq 0.5 cm) CZT detectors with volumes between 2 cm3 and 4 cm3 which…
▽ More
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and γ-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT detectors for the detection of 15-150 keV X-rays from Gamma-Ray Bursts. We report on the systematic tests of thicker (\geq 0.5 cm) CZT detectors with volumes between 2 cm3 and 4 cm3 which are potential detector choices for a number of future X-ray telescopes that operate in the 10 keV to a few MeV energy range. The detectors contacted in our laboratory achieve Full Width Half Maximum energy resolutions of 2.7 keV (4.5%) at 59 keV, 3 keV (2.5%) at 122 keV and 4 keV (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are among the world-best results for \geq 0.5 cm thick CZT detectors. We use the data set to study trends of how the energy resolution depends on the detector thickness and on the pixel pitch. Unfortunately, we do not find clear trends, indicating that even for the extremely good energy resolutions reported here, the achievable energy resolutions are largely determined by the properties of individual crystals. Somewhat surprisingly, we achieve the reported results without applying a correction of the anode signals for the depth of the interaction. Measuring the interaction depths thus does not seem to be a pre-requisite for achieving sub-1% energy resolutions at 662 keV.
△ Less
Submitted 8 February, 2011;
originally announced February 2011.
-
AXTAR: Mission Design Concept
Authors:
Paul S. Ray,
Deepto Chakrabarty,
Colleen A. Wilson-Hodge,
Bernard F. Phlips,
Ronald A. Remillard,
Alan M. Levine,
Kent S. Wood,
Michael T. Wolff,
Chul S. Gwon,
Tod E. Strohmayer,
Michael Baysinger,
Michael S. Briggs,
Peter Capizzo,
Leo Fabisinski,
Randall C. Hopkins,
Linda S. Hornsby,
Les Johnson,
C. Dauphne Maples,
Janie H. Miernik,
Dan Thomas,
Gianluigi De Geronimo
Abstract:
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at…
▽ More
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at the natural time scales of neutron star surfaces and black hole event horizons, thus probing the physics of ultradense matter, strongly curved spacetimes, and intense magnetic fields. AXTAR's main instrument, the Large Area Timing Array (LATA) is a collimated instrument with 2-50 keV coverage and over 3 square meters effective area. The LATA is made up of an array of supermodules that house 2-mm thick silicon pixel detectors. AXTAR will provide a significant improvement in effective area (a factor of 7 at 4 keV and a factor of 36 at 30 keV) over the RXTE PCA. AXTAR will also carry a sensitive Sky Monitor (SM) that acts as a trigger for pointed observations of X-ray transients in addition to providing high duty cycle monitoring of the X-ray sky. We review the science goals and technical concept for AXTAR and present results from a preliminary mission design study.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
HX-POL - A Balloon-Borne Hard X-Ray Polarimeter
Authors:
H. Krawczynski,
A. Garson III,
Q. Li,
M. Beilicke,
P. Dowkontt,
E. Wulf,
J. Kurfess,
E. Novikova,
G. De Geronimo,
M. G. Baring,
A. K. Harding,
J. Grindlay,
J. S. Hong
Abstract:
We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-…
▽ More
We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.
△ Less
Submitted 3 June, 2010; v1 submitted 9 December, 2008;
originally announced December 2008.
-
Fabrication and Test of Pixelated CZT Detectors with Different Pixel Pitches and Thicknesses
Authors:
Q. Li,
A. Garson,
P. Dowkontt,
J. Martin,
M. Beilicke,
I. Jung,
M. Groza,
A. Burger,
G. De Geronimo,
H. Krawczynski,
.,
.,
.,
.
Abstract:
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system based on two 32-channel NCI-ASICs for pixellated CZT detector arrays has been developed and tested. The CZT detectors supplied by Orbotech (MHB) and eV produ…
▽ More
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system based on two 32-channel NCI-ASICs for pixellated CZT detector arrays has been developed and tested. The CZT detectors supplied by Orbotech (MHB) and eV products (HPB) are tested by NCI-ASIC readout system. The CZT detectors have an array of 8x8 or 11x11 pixel anodes fabricated on the anode surface with the area up to 2 cm x2 cm and the thickness of CZT detectors ranges from 0.5 cm to 1 cm. Energy spectra resolution and electron mobility-lifetime products of 8x8 pixels CZT detector with different thicknesses have been investigated.
△ Less
Submitted 19 November, 2008;
originally announced November 2008.