Skip to main content

Showing 1–10 of 10 results for author: andía, M

.
  1. arXiv:2406.07752  [pdf, ps, other

    gr-qc

    Resonant behavior and stability of a linear three-mirror cavity

    Authors: Paul Stevens, Vincent Loriette, Manuel Andia, François Glotin, Angélique Lartaux-Vollard, Nicolas Leroy, Aymeric van de Walle

    Abstract: The implementation of Fabry-Perot cavities in gravitational-wave detectors has been pivotal to improving their sensitivity, allowing the observation of an increasing number of cosmological events with higher signal-to-noise ratio. Notably, Fabry-Perot cavities play a key role in the frequency-dependent squeezing technique, which provides a reduction of quantum noise over the whole observation freq… ▽ More

    Submitted 11 June, 2024; originally announced June 2024.

  2. arXiv:2403.03004  [pdf, other

    astro-ph.CO gr-qc hep-ph

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Authors: The LIGO Scientific Collaboration, the Virgo Collaboration, the KAGRA Collaboration, A. G. Abac, R. Abbott, H. Abe, I. Abouelfettouh, F. Acernese, K. Ackley, C. Adamcewicz, S. Adhicary, N. Adhikari, R. X. Adhikari, V. K. Adkins, V. B. Adya, C. Affeldt, D. Agarwal, M. Agathos, O. D. Aguiar, I. Aguilar, L. Aiello, A. Ain, P. Ajith, T. Akutsu, S. Albanesi , et al. (1778 additional authors not shown)

    Abstract: Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we prese… ▽ More

    Submitted 5 March, 2024; originally announced March 2024.

    Comments: 20 pages, 5 figures

    Report number: LIGO-P2300250

  3. arXiv:2308.03822  [pdf, other

    astro-ph.HE

    Search for Eccentric Black Hole Coalescences during the Third Observing Run of LIGO and Virgo

    Authors: The LIGO Scientific Collaboration, the Virgo Collaboration, the KAGRA Collaboration, A. G. Abac, R. Abbott, H. Abe, F. Acernese, K. Ackley, C. Adamcewicz, S. Adhicary, N. Adhikari, R. X. Adhikari, V. K. Adkins, V. B. Adya, C. Affeldt, D. Agarwal, M. Agathos, O. D. Aguiar, I. Aguilar, L. Aiello, A. Ain, P. Ajith, T. Akutsu, S. Albanesi, R. A. Alfaidi , et al. (1750 additional authors not shown)

    Abstract: Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effect… ▽ More

    Submitted 7 August, 2023; originally announced August 2023.

    Comments: 24 pages, 5 figures

    Report number: LIGO-P2300080

  4. Open data from the third observing run of LIGO, Virgo, KAGRA and GEO

    Authors: The LIGO Scientific Collaboration, the Virgo Collaboration, the KAGRA Collaboration, R. Abbott, H. Abe, F. Acernese, K. Ackley, S. Adhicary, N. Adhikari, R. X. Adhikari, V. K. Adkins, V. B. Adya, C. Affeldt, D. Agarwal, M. Agathos, O. D. Aguiar, L. Aiello, A. Ain, P. Ajith, T. Akutsu, S. Albanesi, R. A. Alfaidi, A. Al-Jodah, C. Alléné, A. Allocca , et al. (1719 additional authors not shown)

    Abstract: The global network of gravitational-wave observatories now includes five detectors, namely LIGO Hanford, LIGO Livingston, Virgo, KAGRA, and GEO 600. These detectors collected data during their third observing run, O3, composed of three phases: O3a starting in April of 2019 and lasting six months, O3b starting in November of 2019 and lasting five months, and O3GK starting in April of 2020 and lasti… ▽ More

    Submitted 7 February, 2023; originally announced February 2023.

    Comments: 27 pages, 3 figures

    Report number: LIGO-P2200316

  5. arXiv:2010.10563  [pdf, other

    cs.CV cs.AI cs.CL cs.LG

    A Survey on Deep Learning and Explainability for Automatic Report Generation from Medical Images

    Authors: Pablo Messina, Pablo Pino, Denis Parra, Alvaro Soto, Cecilia Besa, Sergio Uribe, Marcelo andía, Cristian Tejos, Claudia Prieto, Daniel Capurro

    Abstract: Every year physicians face an increasing demand of image-based diagnosis from patients, a problem that can be addressed with recent artificial intelligence methods. In this context, we survey works in the area of automatic report generation from medical images, with emphasis on methods using deep neural networks, with respect to: (1) Datasets, (2) Architecture Design, (3) Explainability and (4) Ev… ▽ More

    Submitted 8 January, 2022; v1 submitted 20 October, 2020; originally announced October 2020.

    Comments: Accepted for publication in ACM CSUR

  6. arXiv:2003.10510  [pdf, ps, other

    physics.optics physics.atom-ph

    Accurate laser frequency locking to optical frequency combs under low-signal-to-noise-ratio conditions

    Authors: C. Guo, M. Favier, N. Galland, V. Cambier, H. Álvarez-Martínez, M. Lours, L. De Sarlo, M. Andia, R. Le Targat, S. Bize

    Abstract: We demonstrate a method for accurately locking the frequency of a continuous-wave laser to an optical frequency comb in conditions where the signal-to-noise ratio is low, too low to accommodate other methods. Our method is typically orders of magnitude more accurate than conventional wavemeters and can considerably extend the usable wavelength range of a given optical frequency comb. We illustrate… ▽ More

    Submitted 23 March, 2020; originally announced March 2020.

    Comments: 13 pages, 7 figures, 24 references

    Journal ref: Rev.Sci.Instrum. 91, 033202 (2020)

  7. Microwave preparation of two-dimensional fermionic spin mixtures

    Authors: B. Peaudecerf, M. Andia, M. Brown, E. Haller, S. Kuhr

    Abstract: We present a method for preparing a single two-dimensional sample of a two-spin mixture of fermionic potassium in a single antinode of an optical lattice, in a quantum-gas microscope apparatus. Our technique relies on spatially-selective microwave transitions in a magnetic field gradient. Adiabatic transfer pulses were optimized for high efficiency and minimal atom loss and heating due to spin-cha… ▽ More

    Submitted 25 January, 2019; v1 submitted 2 October, 2018; originally announced October 2018.

    Comments: 8 pages, 5 figures

    Journal ref: New J. Phys. 21 013020 (2019)

  8. Observation of Extra Photon Recoil in a Distorted Optical Field

    Authors: Satyanarayana Bade, Lionel Djadaojee, Manuel Andia, Pierre Cladé, Saïda Guellati-Khélifa

    Abstract: Light carries momentum which induces on atoms a recoil for each photon absorbed. In vacuum, for a monochromatic beam of frequency $ν$, the global momentum per photon is bounded by general principles and is smaller than $h ν/c$ leading to a limit on the recoil. However, locally this limit can be broken. In this paper, we give a general formula to calculate the recoil in vacuum. We show that in a la… ▽ More

    Submitted 20 December, 2018; v1 submitted 11 December, 2017; originally announced December 2017.

    Journal ref: Phys. Rev. Lett. 121, 073603 (2018)

  9. arXiv:1612.04583  [pdf, other

    physics.atom-ph cond-mat.quant-gas quant-ph

    Sub-Doppler laser cooling of 40K with Raman gray molasses on the D2 line

    Authors: G. D. Bruce, E. Haller, B. Peaudecerf, D. A. Cotta, M. Andia, S. Wu, M. Y. H. Johnson, B. W. Lovett, S. Kuhr

    Abstract: Gray molasses is a powerful tool for sub-Doppler laser cooling of atoms to low temperatures. For alkaline atoms, this technique is commonly implemented with cooling lasers which are blue-detuned from either the D1 or D2 line. Here we show that efficient gray molasses can be implemented on the D2 line of 40K with red-detuned lasers. We obtained temperatures of 48(2) microKelvin, which enables direc… ▽ More

    Submitted 14 December, 2016; originally announced December 2016.

    Comments: 6 pages, 5 figures

    Journal ref: J. Phys. B: At. Mol. Opt. Phys. 50, 095002 (2017)

  10. arXiv:1309.1713  [pdf, other

    physics.atom-ph quant-ph

    Compact atomic gravimeter based on a pulsed and accelerated optical lattice

    Authors: Manuel Andia, Raphael Jannin, François Nez, François Biraben, Saïda Guellati-Khélifa, Pierre Cladé

    Abstract: We present a new scheme of compact atomic gravimeter based on atom interferometry. Atoms are maintained against gravity using a sequence of coherent accelerations performed by the Bloch oscillations technique. We demonstrate a sensitivity of 4.8$\times 10^{-8}$ with an integration time of 4 min. Combining this method with an atomic elevator allows to measure the local gravity at different position… ▽ More

    Submitted 6 September, 2013; originally announced September 2013.