    Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector

    Authors: Florian Beißer, Dennis Haag, Rafael Ballabriga, Rolf Behrens, Michael Campbell, Christian Fuhg, Patrick Hufschmidt, Oliver Hupe, Carolin Kupillas, Xavier Llopart, Jürgen Roth, Sebastian Schmidt, Markus Schneider, Lukas Tlustos, Winnie Wong, Hayo Zutz, Thilo Michel, Erlangen Centre for Astroparticle Physics, CERN, Physikalisch-Technische Bundesantalt, was with the Erlangen Centre for Astroparticle Physics, is now with Helene-Lange-Gymnasium, was with the Erlangen Centre for Astroparticle Physics, is now with CodeCamp, : , et al. (6 additional authors not shown)

    Abstract: Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy de… ▽ More

    Submitted 1 August, 2023; v1 submitted 9 May, 2023; originally announced May 2023.

    Comments: This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible. 9 pages, 10 figures

  2. arXiv:2106.06714  [pdf, other

    physics.med-ph physics.ins-det

    Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector

    Authors: Dennis Haag, Sebastian Schmidt, Patrick Hufschmidt, Gisela Anton, Rafael Ballabriga, Rolf Behrens, Michael Campbell, Franziska Eberle, Christian Fuhg, Oliver Hupe, Xavier Llopart, Jürgen Roth, Lukas Tlustos, Winnie Wong, Hayo Zutz, Thilo Michel

    Abstract: First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of… ▽ More

    Submitted 30 November, 2022; v1 submitted 12 June, 2021; originally announced June 2021.

    Comments: 6 pages, 4 figures. This work was accepted for publication in IEEE Transactions on Nuclear Science