-
Effects of simultaneous real-time fMRI and EEG neurofeedback in major depressive disorder evaluated with brain electromagnetic tomography
Authors:
Vadim Zotev,
Jerzy Bodurka
Abstract:
Recently, we reported an emotion self-regulation study (Zotev et al., 2020), in which patients with major depressive disorder (MDD) used simultaneous real-time fMRI and EEG neurofeedback (rtfMRI-EEG-nf) to upregulate two fMRI and two EEG activity measures, relevant to MDD. The target measures included fMRI activities of the left amygdala and left rostral anterior cingulate cortex, and frontal EEG…
▽ More
Recently, we reported an emotion self-regulation study (Zotev et al., 2020), in which patients with major depressive disorder (MDD) used simultaneous real-time fMRI and EEG neurofeedback (rtfMRI-EEG-nf) to upregulate two fMRI and two EEG activity measures, relevant to MDD. The target measures included fMRI activities of the left amygdala and left rostral anterior cingulate cortex, and frontal EEG asymmetries in the alpha band (FAA) and high-beta band (FBA). Here we apply the exact low resolution brain electromagnetic tomography (eLORETA) to investigate EEG source activities during the rtfMRI-EEG-nf procedure. The exploratory analyses reveal significant changes in hemispheric lateralities of upper alpha and high-beta current source densities in the prefrontal regions, consistent with upregulation of the FAA and FBA during the rtfMRI-EEG-nf task. Similar laterality changes are observed for current source densities in the amygdala. Prefrontal upper alpha current density changes show significant negative correlations with anhedonia severity. Changes in prefrontal high-beta current density are consistent with reduction in comorbid anxiety. Comparisons with results of previous LORETA studies suggest that the rtfMRI-EEG-nf training is beneficial to MDD patients, and may have the ability to correct functional deficiencies associated with anhedonia and comorbid anxiety in MDD.
△ Less
Submitted 21 October, 2020; v1 submitted 2 June, 2020;
originally announced June 2020.
-
Automated Pipeline for EEG Artifact Reduction (APPEAR) Recorded during fMRI
Authors:
Ahmad Mayeli,
Obada Al Zoubi,
Kaylee Henry,
Chung Ki Wong,
Evan J. White,
Qingfei Luo,
Vadim Zotev,
Hazem Refai,
the Tulsa 1000 Investigators,
Jerzy Bodurka
Abstract:
Objective. EEG data collected during fMRI acquisition are contaminated with MRI gradients and ballistocardiogram (BCG) artifacts, in addition to artifacts of physiological origin. There have been several attempts for reducing these artifacts with manual and time-consuming pre-processing, which may result in biasing EEG data due to variations in selecting steps order, parameters, and classification…
▽ More
Objective. EEG data collected during fMRI acquisition are contaminated with MRI gradients and ballistocardiogram (BCG) artifacts, in addition to artifacts of physiological origin. There have been several attempts for reducing these artifacts with manual and time-consuming pre-processing, which may result in biasing EEG data due to variations in selecting steps order, parameters, and classification of artifactual independent components. Thus, there is a strong urge to develop a fully automatic and comprehensive pipeline for reducing all major EEG artifacts. In this work, we introduced an open-access toolbox with a fully automatic pipeline for reducing artifacts from EEG data collected simultaneously with fMRI (refer to APPEAR). Approach. The pipeline integrates average template subtraction and independent component analysis (ICA) to suppress both MRI-related and physiological artifacts. To validate our results, we tested APPEAR on EEG data recorded from healthy control subjects during resting-state (n=48) and task-based (i.e., event-related-potentials [ERP]; n=8) paradigms. The chosen gold standard is an expert manual review of the EEG database. Main results. We compared manually and automated corrected EEG data during resting-state using frequency analysis and continuous wavelet transformation and found no significant differences between the two corrections. A comparison between ERP data recorded during a so-called stop-signal task (e.g., amplitude measures and signal-to-noise ratio) also showed no differences between the manually and fully automatic fMRI-EEG-corrected data. Significance: APPEAR offers the first comprehensive open-source toolbox that can speed up advancement of EEG analysis and enhance replication by avoiding experimenters' preferences while allowing for processing large EEG-fMRI cohorts composed of hundreds of subjects with manageable researcher time and effort.
△ Less
Submitted 30 June, 2021; v1 submitted 11 December, 2019;
originally announced December 2019.
-
Integration of Simultaneous Resting-State Electroencephalography, Functional Magnetic Resonance Imaging, and Eye-Tracker Methods to Determine and Verify Electroencephalography Vigilance Measure
Authors:
Ahmad Mayeli,
Obada Al Zoubi,
Masaya Misaki,
Jennifer L. Stewart,
Vadim Zotev,
Qingfei Luo,
Raquel Phillips,
Stefan Fischer,
Marcus Goetz,
Martin P. Paulus,
Hazem Refai,
Jerzy Bodurka
Abstract:
Background/Introduction: Concurrent electroencephalography and resting-state functional magnetic resonance imaging (rsfMRI) have been widely used for studying the (presumably) awake and alert human brain with high temporal/spatial resolution. Although rsfMRI scans are typically collected while individuals are instructed to focus their eyes on a fixated cross, objective and verified experimental me…
▽ More
Background/Introduction: Concurrent electroencephalography and resting-state functional magnetic resonance imaging (rsfMRI) have been widely used for studying the (presumably) awake and alert human brain with high temporal/spatial resolution. Although rsfMRI scans are typically collected while individuals are instructed to focus their eyes on a fixated cross, objective and verified experimental measures to quantify degree of vigilance are not readily available. Electroencephalography (EEG) is the modality extensively used for estimating vigilance, especially during eyes-closed resting state. However, pupil size measured using an eye-tracker device could provide an indirect index of vigilance. Methods: Three 12-min resting scans (eyes open, fixating on the cross) were collected from 10 healthy control participants. We simultaneously collected EEG, fMRI, physiological, and eye-tracker data and investigated the correlation between EEG features, pupil size, and heart rate. Furthermore, we used pupil size and EEG features as regressors to find their correlations with blood-oxygen-level-dependent fMRI measures. Results: EEG frontal and occipital beta power (FOBP) correlates with pupil size changes, an indirect index for locus coeruleus activity implicated in vigilance regulation (r = 0.306, p < 0.001). Moreover, FOBP also correlated with heart rate (r = 0.255, p < 0.001), as well as several brain regions in the anticorrelated network, including the bilateral insula and inferior parietal lobule. Discussion: In this study, we investigated whether simultaneous EEG-fMRI combined with eye-tracker measurements can be used to determine EEG signal feature associated with vigilance measures during eyes-open rsfMRI. Our results support the conclusion that FOBP is an objective measure of vigilance in healthy human subjects.
△ Less
Submitted 19 June, 2021; v1 submitted 10 December, 2019;
originally announced December 2019.
-
Emotion self-regulation training in major depressive disorder using simultaneous real-time fMRI and EEG neurofeedback
Authors:
Vadim Zotev,
Ahmad Mayeli,
Masaya Misaki,
Jerzy Bodurka
Abstract:
Simultaneous real-time fMRI and EEG neurofeedback (rtfMRI-EEG-nf) is an emerging neuromodulation approach, that enables simultaneous volitional regulation of both hemodynamic (BOLD fMRI) and electrophysiological (EEG) brain activities. Here we report the first application of rtfMRI-EEG-nf for emotion self-regulation training in patients with major depressive disorder (MDD). In this proof-of-concep…
▽ More
Simultaneous real-time fMRI and EEG neurofeedback (rtfMRI-EEG-nf) is an emerging neuromodulation approach, that enables simultaneous volitional regulation of both hemodynamic (BOLD fMRI) and electrophysiological (EEG) brain activities. Here we report the first application of rtfMRI-EEG-nf for emotion self-regulation training in patients with major depressive disorder (MDD). In this proof-of-concept study, MDD patients in the experimental group (n=16) used rtfMRI-EEG-nf during a happy emotion induction task to simultaneously upregulate two fMRI and two EEG activity measures relevant to MDD. The target measures included BOLD activities of the left amygdala (LA) and left rostral anterior cingulate cortex (rACC), and frontal EEG asymmetries in the alpha band (FAA, [7.5-12.5] Hz) and high-beta band (FBA, [21-30] Hz). MDD patients in the control group (n=8) were provided with sham feedback signals. An advanced procedure for improved real-time EEG-fMRI artifact correction was implemented. The experimental group participants demonstrated significant upregulation of the LA BOLD activity, FAA, and FBA during the rtfMRI-EEG-nf task, as well as significant enhancement in fMRI connectivity between the LA and left rACC. Average individual FAA changes during the rtfMRI-EEG-nf task positively correlated with depression and anhedonia severities, and negatively correlated with after-vs-before changes in depressed mood ratings. Temporal correlations between the FAA and FBA time courses and the LA BOLD activity were significantly enhanced during the rtfMRI-EEG-nf task. The experimental group participants reported significant mood improvements after the training. Our results suggest that the rtfMRI-EEG-nf may have potential for treatment of MDD.
△ Less
Submitted 29 June, 2020; v1 submitted 12 September, 2019;
originally announced September 2019.
-
Real-time fMRI neurofeedback training of the amygdala activity with simultaneous EEG in veterans with combat-related PTSD
Authors:
Vadim Zotev,
Raquel Phillips,
Masaya Misaki,
Chung Ki Wong,
Brent E. Wurfel,
Frank Krueger,
Matthew Feldner,
Jerzy Bodurka
Abstract:
Posttraumatic stress disorder (PTSD) is a chronic and disabling neuropsychiatric disorder characterized by insufficient top-down modulation of the amygdala activity by the prefrontal cortex. Real-time fMRI neurofeedback (rtfMRI-nf) is an emerging method with potential for modifying the amygdala-prefrontal interactions. We report the first controlled emotion self-regulation study in veterans with c…
▽ More
Posttraumatic stress disorder (PTSD) is a chronic and disabling neuropsychiatric disorder characterized by insufficient top-down modulation of the amygdala activity by the prefrontal cortex. Real-time fMRI neurofeedback (rtfMRI-nf) is an emerging method with potential for modifying the amygdala-prefrontal interactions. We report the first controlled emotion self-regulation study in veterans with combat-related PTSD utilizing rtfMRI-nf of the amygdala activity. PTSD patients in the experimental group (EG, n=20) learned to upregulate BOLD activity of the left amygdala (LA) using rtfMRI-nf during a happy emotion induction task. PTSD patients in the control group (CG, n=11) were provided with a sham rtfMRI-nf. The study included three rtfMRI-nf training sessions, and EEG recordings were performed simultaneously with fMRI. PTSD severity was assessed using the Clinician-Administered PTSD Scale (CAPS). The EG participants showed a significant reduction in total CAPS ratings, including significant reductions in avoidance and hyperarousal symptoms. Overall, 80% of the EG participants demonstrated clinically meaningful reductions in CAPS ratings, compared to 38% in the CG. During the first session, fMRI connectivity of the LA with the orbitofrontal cortex and the dorsolateral prefrontal cortex (DLPFC) was progressively enhanced, and this enhancement significantly and positively correlated with initial CAPS ratings. Left-lateralized enhancement in upper alpha EEG coherence also exhibited a significant positive correlation with the initial CAPS. Reduction in PTSD severity between the first and last rtfMRI-nf sessions significantly correlated with enhancement in functional connectivity between the LA and the left DLPFC. Our results demonstrate that the rtfMRI-nf of the amygdala activity has the potential to correct the amygdala-prefrontal functional connectivity deficiencies specific to PTSD.
△ Less
Submitted 10 April, 2018; v1 submitted 27 January, 2018;
originally announced January 2018.
-
Real-time fMRI neurofeedback of the mediodorsal and anterior thalamus enhances correlation between thalamic BOLD activity and alpha EEG rhythm
Authors:
Vadim Zotev,
Masaya Misaki,
Raquel Phillips,
Chung Ki Wong,
Jerzy Bodurka
Abstract:
Real-time fMRI neurofeedback (rtfMRI-nf) with simultaneous EEG allows volitional modulation of BOLD activity of target brain regions and investigation of related electrophysiological activity. We applied this approach to study correlations between thalamic BOLD activity and alpha EEG rhythm. Healthy volunteers in the experimental group (EG, n=15) learned to upregulate BOLD activity of the target r…
▽ More
Real-time fMRI neurofeedback (rtfMRI-nf) with simultaneous EEG allows volitional modulation of BOLD activity of target brain regions and investigation of related electrophysiological activity. We applied this approach to study correlations between thalamic BOLD activity and alpha EEG rhythm. Healthy volunteers in the experimental group (EG, n=15) learned to upregulate BOLD activity of the target region consisting of the mediodorsal (MD) and anterior (AN) thalamic nuclei using the rtfMRI-nf during retrieval of happy autobiographical memories. Healthy subjects in the control group (CG, n=14) were provided with a sham feedback. The EG participants were able to significantly increase BOLD activities of the MD and AN. Functional connectivity between the MD and the inferior precuneus was significantly enhanced during the rtfMRI-nf task. Average individual changes in the occipital alpha EEG power significantly correlated with the average MD BOLD activity levels for the EG. Temporal correlations between the occipital alpha EEG power and BOLD activities of the MD and AN were significantly enhanced, during the rtfMRI-nf task, for the EG compared to the CG. Temporal correlations with the alpha power were also significantly enhanced for the posterior nodes of the default mode network, including the precuneus/posterior cingulate, and for the dorsal striatum. Our findings suggest that the temporal correlation between the MD BOLD activity and posterior alpha EEG power is modulated by the interaction between the MD and the inferior precuneus, reflected in their functional connectivity. Our results demonstrate the potential of the rtfMRI-nf with simultaneous EEG for non-invasive neuromodulation studies of human brain function.
△ Less
Submitted 19 November, 2017; v1 submitted 14 February, 2017;
originally announced February 2017.
-
Correlation between amygdala BOLD activity and frontal EEG asymmetry during real-time fMRI neurofeedback training in patients with depression
Authors:
Vadim Zotev,
Han Yuan,
Masaya Misaki,
Raquel Phillips,
Kymberly D. Young,
Matthew T. Feldner,
Jerzy Bodurka
Abstract:
Real-time fMRI neurofeedback (rtfMRI-nf) is an emerging approach for studies and novel treatments of major depressive disorder (MDD). EEG performed simultaneously with an rtfMRI-nf procedure allows an independent evaluation of rtfMRI-nf brain modulation effects. Frontal EEG asymmetry in the alpha band is a widely used measure of emotion and motivation that shows profound changes in depression. How…
▽ More
Real-time fMRI neurofeedback (rtfMRI-nf) is an emerging approach for studies and novel treatments of major depressive disorder (MDD). EEG performed simultaneously with an rtfMRI-nf procedure allows an independent evaluation of rtfMRI-nf brain modulation effects. Frontal EEG asymmetry in the alpha band is a widely used measure of emotion and motivation that shows profound changes in depression. However, it has never been directly related to simultaneously acquired fMRI data. We report the first study investigating electrophysiological correlates of the rtfMRI-nf procedure, by combining rtfMRI-nf with simultaneous and passive EEG recordings. In this pilot study, MDD patients in the experimental group (n=13) learned to upregulate BOLD activity of the left amygdala using an rtfMRI-nf during a happy emotion induction task. MDD patients in the control group (n=11) were provided with a sham rtfMRI-nf. Correlations between frontal EEG asymmetry in the upper alpha band and BOLD activity across the brain were examined. Average individual changes in frontal EEG asymmetry during the rtfMRI-nf task for the experimental group showed a significant positive correlation with the MDD patients' depression severity ratings, consistent with an inverse correlation between the depression severity and frontal EEG asymmetry at rest. Temporal correlations between frontal EEG asymmetry and BOLD activity were significantly enhanced, during the rtfMRI-nf task, for the amygdala and many regions associated with emotion regulation. Our findings demonstrate an important link between amygdala BOLD activity and frontal EEG asymmetry. Our EEG asymmetry results suggest that the rtfMRI-nf training targeting the amygdala is beneficial to MDD patients, and that alpha-asymmetry EEG-nf would be compatible with the amygdala rtfMRI-nf. Combination of the two could enhance emotion regulation training and benefit MDD patients.
△ Less
Submitted 10 February, 2016; v1 submitted 6 September, 2014;
originally announced September 2014.
-
Prefrontal control of the amygdala during real-time fMRI neurofeedback training of emotion regulation
Authors:
Vadim Zotev,
Raquel Phillips,
Kymberly D. Young,
Wayne C. Drevets,
Jerzy Bodurka
Abstract:
We observed in a previous study (PLoS ONE 6:e24522) that the self-regulation of amygdala activity via real-time fMRI neurofeedback (rtfMRI-nf) with positive emotion induction was associated, in healthy participants, with an enhancement in the functional connectivity between the left amygdala (LA) and six regions of the prefrontal cortex. These regions included the left rostral anterior cingulate c…
▽ More
We observed in a previous study (PLoS ONE 6:e24522) that the self-regulation of amygdala activity via real-time fMRI neurofeedback (rtfMRI-nf) with positive emotion induction was associated, in healthy participants, with an enhancement in the functional connectivity between the left amygdala (LA) and six regions of the prefrontal cortex. These regions included the left rostral anterior cingulate cortex (rACC), bilateral dorsomedial prefrontal cortex (DMPFC), bilateral superior frontal gyrus (SFG), and right medial frontopolar cortex (MFPC). Together with the LA, these six prefrontal regions thus formed the functional neuroanatomical network engaged during the rtfMRI-nf procedure. Here we perform a structural vector autoregression (SVAR) analysis of the effective connectivity for this network. The SVAR analysis demonstrates that the left rACC plays an important role during the rtfMRI-nf training, modulating the LA and the other network regions. According to the analysis, the rtfMRI-nf training leads to a significant enhancement in the time-lagged effect of the left rACC on the LA. The training is also accompanied by significant increases in the instantaneous (contemporaneous) effects of the left rACC on four other regions - the bilateral DMPFC, the right MFPC, and the left SFG. The instantaneous effects of the LA on the bilateral DMPFC are also significantly enhanced. Our results are consistent with a broad literature supporting the role of the rACC in emotion processing and regulation. Our analysis provides, for the first time, insights into the causal relationships within the network of regions engaged during the rtfMRI-nf procedure targeting the amygdala. It suggests that the rACC may constitute a promising target for rtfMRI-nf training along with the amygdala in patients with affective disorders, particularly posttraumatic stress disorder (PTSD).
△ Less
Submitted 25 August, 2013;
originally announced August 2013.
-
Self-regulation of human brain activity using simultaneous real-time fMRI and EEG neurofeedback
Authors:
Vadim Zotev,
Raquel Phillips,
Han Yuan,
Masaya Misaki,
Jerzy Bodurka
Abstract:
Neurofeedback is a promising approach for non-invasive modulation of human brain activity with applications for treatment of mental disorders and enhancement of brain performance. Neurofeedback techniques are commonly based on either electroencephalography (EEG) or real-time functional magnetic resonance imaging (rtfMRI). Advances in simultaneous EEG-fMRI have made it possible to combine the two a…
▽ More
Neurofeedback is a promising approach for non-invasive modulation of human brain activity with applications for treatment of mental disorders and enhancement of brain performance. Neurofeedback techniques are commonly based on either electroencephalography (EEG) or real-time functional magnetic resonance imaging (rtfMRI). Advances in simultaneous EEG-fMRI have made it possible to combine the two approaches. Here we report the first implementation of simultaneous multimodal rtfMRI and EEG neurofeedback (rtfMRI-EEG-nf). It is based on a novel system for real-time integration of simultaneous rtfMRI and EEG data streams. We applied the rtfMRI-EEG-nf to training of emotional self-regulation in healthy subjects performing a positive emotion induction task based on retrieval of happy autobiographical memories. The participants were able to simultaneously regulate their BOLD fMRI activation in the left amygdala and frontal EEG power asymmetry in the high-beta band using the rtfMRI-EEG-nf. Our proof-of-concept results demonstrate the feasibility of simultaneous self-regulation of both hemodynamic (rtfMRI) and electrophysiological (EEG) activity of the human brain. They suggest potential applications of rtfMRI-EEG-nf in the development of novel cognitive neuroscience research paradigms and enhanced cognitive therapeutic approaches for major neuropsychiatric disorders, particularly depression.
△ Less
Submitted 12 August, 2013; v1 submitted 20 January, 2013;
originally announced January 2013.
-
EEG-assisted retrospective motion correction for fMRI: E-REMCOR
Authors:
Vadim Zotev,
Han Yuan,
Raquel Phillips,
Jerzy Bodurka
Abstract:
We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are utilized for slice-specific motion correction of unprocessed fMRI data. Performance of the…
▽ More
We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are utilized for slice-specific motion correction of unprocessed fMRI data. Performance of the method is demonstrated by correction of fMRI data from five patients with major depressive disorder, who exhibited head movements by 1-3 mm during a resting EEG-fMRI run. The fMRI datasets, corrected using eight to ten EEG-based motion regressors, show significant improvements in temporal SNR (TSNR) of fMRI time series, particularly in the frontal brain regions and near the surface of the brain. The TSNR improvements are as high as 50% for large brain areas in single-subject analysis and as high as 25% when the results are averaged across the subjects. Simultaneous application of the EEG-based motion correction and physiological noise correction by means of RETROICOR leads to average TSNR enhancements as high as 35% for large brain regions. These TSNR improvements are largely preserved after the subsequent fMRI volume registration and regression of fMRI motion parameters. The proposed EEG-assisted method of retrospective fMRI motion correction (referred to as E-REMCOR) can be used to improve quality of fMRI data with severe motion artifacts and to reduce spurious correlations between the EEG and fMRI data caused by head movements. It does not require any specialized equipment beyond the standard EEG-fMRI instrumentation and can be applied retrospectively to any existing EEG-fMRI data set.
△ Less
Submitted 16 July, 2012; v1 submitted 21 January, 2012;
originally announced January 2012.
-
Microtesla MRI with dynamic nuclear polarization
Authors:
V. S. Zotev,
T. Owens,
A. N. Matlashov,
I. M. Savukov,
J. J. Gomez,
M. A. Espy
Abstract:
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by SQUID sensors to enable in vivo MRI at microtesla-range magnetic fields. Despite significant advances, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample p…
▽ More
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by SQUID sensors to enable in vivo MRI at microtesla-range magnetic fields. Despite significant advances, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample polarization. Dynamic nuclear polarization (DNP) is a widely used approach that allows polarization enhancement by two-four orders of magnitude without an increase in the polarizing field strength. In this work, the first implementation of microtesla MRI with Overhauser DNP and SQUID signal detection is described. The first measurements of carbon-13 NMR spectra at microtesla fields are also reported. The experiments were performed at the measurement field of 96 microtesla with Overhauser enhancement at 3.5 - 5.7 mT field. The Overhauser DNP enabled nuclear polarization enhancement by factor as high as -95 for protons and as high as -200 for carbon-13, corresponding to thermal polarizations at 0.33 T and 1.1 T fields, respectively. These results demonstrate that SQUID-based microtesla MRI can be naturally combined with Overhauser DNP in one system, and that its signal-to-noise performance is greatly improved in this case. They also suggest that microtesla MRI can become an efficient tool for in vivo imaging of hyperpolarized carbon-13, produced by the low-temperature dissolution DNP.
△ Less
Submitted 11 July, 2010; v1 submitted 5 November, 2009;
originally announced November 2009.
-
SQUID-based microtesla MRI for in vivo relaxometry of the human brain
Authors:
V. S. Zotev,
P. L. Volegov,
A. N. Matlashov,
I. M. Savukov,
T. Owens,
M. A. Espy
Abstract:
SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 m…
▽ More
SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 microtesla field using a seven-channel SQUID system designed for microtesla MRI and MEG. Values of T1, measured for different tissues at this field, are found to be close (within 5%) to the corresponding values of the transverse relaxation time T2 at the same field. Implications of this result for imaging contrast in microtesla MRI are discussed.
△ Less
Submitted 3 November, 2008;
originally announced November 2008.
-
Microtesla MRI of the human brain combined with MEG
Authors:
V. S. Zotev,
A. N. Matlashov,
P. L. Volegov,
I. M. Savukov,
M. A. Espy,
J. C. Mosher,
J. J. Gomez,
R. H. Kraus Jr
Abstract:
One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single…
▽ More
One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single instrument. Indirect matching of MEG and MRI data leads to significant co-registration errors. A recently proposed imaging method - SQUID-based microtesla MRI - can be naturally combined with MEG in the same system to directly provide structural maps for MEG-localized sources. It enables easy and accurate integration of MEG and MRI/fMRI, because microtesla MR images can be precisely matched to structural images provided by high-field MRI and other techniques. Here we report the first images of the human brain by microtesla MRI, together with auditory MEG (functional) data, recorded using the same seven-channel SQUID system during the same imaging session. The images were acquired at 46 microtesla measurement field with pre-polarization at 30 mT. We also estimated transverse relaxation times for different tissues at microtesla fields. Our results demonstrate feasibility and potential of human brain imaging by microtesla MRI. They also show that two new types of imaging equipment - low-cost systems for anatomical MRI of the human brain at microtesla fields, and more advanced instruments for combined functional (MEG) and structural (microtesla MRI) brain imaging - are practical.
△ Less
Submitted 28 June, 2008; v1 submitted 1 November, 2007;
originally announced November 2007.
-
SQUID-based instrumentation for ultra-low-field MRI
Authors:
V. S. Zotev,
A. N. Matlashov,
P. L. Volegov,
A. V. Urbaitis,
M. A. Espy,
R. H. Kraus Jr
Abstract:
Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement field. In this work, a seven-channel SQUID system designed for simultaneous 3D ULF MRI and magnetoencephalography (MEG) is described. The system includes seven sec…
▽ More
Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement field. In this work, a seven-channel SQUID system designed for simultaneous 3D ULF MRI and magnetoencephalography (MEG) is described. The system includes seven second-order SQUID gradiometers, characterized by magnetic field resolutions of 1.2 - 2.8 fT/rtHz. It is also equipped with five sets of coils for 3D Fourier imaging with pre-polarization. Essential technical details of the design are discussed. The system's ULF MRI performance is demonstrated by multi-channel 3D images of a preserved sheep brain acquired at 46 microtesla measurement field with pre-polarization at 40 mT. The imaging resolution is 2.5 mm x 2.5 mm x 5 mm. The ULF MRI images are compared to images of the same brain acquired using conventional high-field MRI. Different ways to improve imaging SNR are discussed.
△ Less
Submitted 30 July, 2007; v1 submitted 4 May, 2007;
originally announced May 2007.
-
Parallel MRI at microtesla fields
Authors:
V. S. Zotev,
P. L. Volegov,
A. N. Matlashov,
M. A. Espy,
J. C. Mosher,
R. H. Kraus Jr
Abstract:
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precessi…
▽ More
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at microtesla-range measurement fields. In this work, parallel imaging at microtesla fields is systematically studied for the first time. A seven-channel SQUID system, designed for both ULF MRI and magnetoencephalography (MEG), is used to acquire 3D images of a human hand, as well as 2D images of a large water phantom. The imaging is performed at 46 microtesla measurement field with pre-polarization at 40 mT. It is shown how the use of seven channels increases imaging field of view and improves signal-to-noise ratio for the hand images. A simple procedure for approximate correction of concomitant gradient artifacts is described. Noise propagation is analyzed experimentally, and the main source of correlated noise is identified. Accelerated imaging based on one-dimensional undersampling and 1D SENSE (sensitivity encoding) image reconstruction is studied in the case of the 2D phantom. Actual 3-fold imaging acceleration in comparison to single-average fully encoded Fourier imaging is demonstrated. These results show that parallel imaging methods are efficient in ULF MRI, and that imaging performance of SQUID-based instruments improves substantially as the number of channels is increased.
△ Less
Submitted 27 March, 2008; v1 submitted 16 January, 2007;
originally announced January 2007.
-
Multi-sensor system for simultaneous ultra-low-field MRI and MEG
Authors:
V. S. Zotev,
A. N. Matlachov,
P. L. Volegov,
H. J. Sandin,
M. A. Espy,
J. C. Mosher,
A. V. Urbaitis,
S. G. Newman,
R. H. Kraus Jr
Abstract:
Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low fields (ULF MRI) are two methods based on the ability of SQUID (superconducting quantum interference device) sensors to detect femtotesla magnetic fields. Combination of these methods will allow simultaneous functional (MEG) and structural (ULF MRI) imaging of the human brain. In this paper, we report the first implementati…
▽ More
Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low fields (ULF MRI) are two methods based on the ability of SQUID (superconducting quantum interference device) sensors to detect femtotesla magnetic fields. Combination of these methods will allow simultaneous functional (MEG) and structural (ULF MRI) imaging of the human brain. In this paper, we report the first implementation of a multi-sensor SQUID system designed for both MEG and ULF MRI. We present a multi-channel image of a human hand obtained at 46 microtesla field, as well as results of auditory MEG measurements with the new system.
△ Less
Submitted 5 December, 2006;
originally announced December 2006.
-
Multi-Channel SQUID System for MEG and Ultra-Low-Field MRI
Authors:
Vadim S. Zotev,
Andrei N. Matlachov,
Petr L. Volegov,
Henrik J. Sandin,
Michelle A. Espy,
John C. Mosher,
Algis V. Urbaitis,
Shaun G. Newman,
Robert H. Kraus Jr
Abstract:
A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm baseline, having magnetic field resolution of 1.2-2.8 fT/rtHz. It also includes four sets of coils for 2-D Fourier imaging with pre-polarization. The system'…
▽ More
A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm baseline, having magnetic field resolution of 1.2-2.8 fT/rtHz. It also includes four sets of coils for 2-D Fourier imaging with pre-polarization. The system's MEG performance was demonstrated by measurements of auditory evoked response. The system was also used to obtain a multi-channel 2-D image of a whole human hand at the measurement field of 46 microtesla with 3 by 3 mm resolution.
△ Less
Submitted 29 November, 2006;
originally announced November 2006.
-
Comment on "New Methods for Old Coulomb Few-Body Problems"
Authors:
V. S. Zotev
Abstract:
In this Comment on the above mentioned paper by F. E. Harris, A. M. Frolov, and V. H. Smith, we briefly review our contributions to development of new methods for solution of the Coulomb four-body problem. We show that our research group, headed by Prof. T. K. Rebane, had a priority in using the fully correlated exponential basis for variational calculations of four-body systems. We also draw at…
▽ More
In this Comment on the above mentioned paper by F. E. Harris, A. M. Frolov, and V. H. Smith, we briefly review our contributions to development of new methods for solution of the Coulomb four-body problem. We show that our research group, headed by Prof. T. K. Rebane, had a priority in using the fully correlated exponential basis for variational calculations of four-body systems. We also draw attention to the fact that our group subsequently implemented a more advanced method, which uses highly efficient exponential-trigonometric basis functions for solution of the same problem.
△ Less
Submitted 31 May, 2005; v1 submitted 14 March, 2005;
originally announced March 2005.
-
SQUID Magnetometry for Cancer Screening a Feasibility Study
Authors:
G. G. Kenning,
R. Rodriguez,
V. S. Zotev,
A. Moslemi,
S. Wilson,
L. Hawel,
C. Byus,
J. S. Kovach
Abstract:
The recent demonstration that nanoparticles associated with various biological molecules and pharmacological agents can be administered systemically to humans, without toxicity from the particles, has opened a new era in the targeting of such particles to specific tissues in the body for the imaging and therapy of disease. The majority of particles used for this purpose contain iron and are dete…
▽ More
The recent demonstration that nanoparticles associated with various biological molecules and pharmacological agents can be administered systemically to humans, without toxicity from the particles, has opened a new era in the targeting of such particles to specific tissues in the body for the imaging and therapy of disease. The majority of particles used for this purpose contain iron and are detected in the body by magnetic resonance imaging. We believe a superconducting quantum interference device (SQUID) could provide quantitative and spatial information relevant to localization of superparamagnetic nanoparticles directed to a specific cell target in vivo. We envision a scanning system consisting of a DC induction field, a transport device, and an array of planar first order gradiometer coils coupled to DC SQUID amplifiers. We performed a set of computer simulations using experimentally determined values for concentrations of paramagnetic particles achievable in specific tissues of the mouse in vivo and concentrations of particles linked to monoclonal antibodies specific to antigens of two human cancer cell lines in vitro. An instrument to target distance of 10 centimeters was selected so that for an average adult scanning both the anterior and posterior surfaces could provide coverage of most of the body. The simulations demonstrate the feasibility of SQUID magnetometry for monitoring achievable concentrations of superparamagnetic particles in vivo and raise the possibility of using this approach to detect and localize collections of abnormal cells targeted by such particles.
△ Less
Submitted 2 September, 2003;
originally announced September 2003.
-
Analytic Evaluation of Four-Particle Integrals with Complex Parameters
Authors:
V. S. Zotev,
T. K. Rebane
Abstract:
The method for analytic evaluation of four-particle integrals, proposed by Fromm and Hill, is generalized to include complex exponential parameters. An original procedure of numerical branch tracking for multiple valued functions is developed. It allows high precision variational solution of the Coulomb four-body problem in a basis of exponential-trigonometric functions of interparticle separati…
▽ More
The method for analytic evaluation of four-particle integrals, proposed by Fromm and Hill, is generalized to include complex exponential parameters. An original procedure of numerical branch tracking for multiple valued functions is developed. It allows high precision variational solution of the Coulomb four-body problem in a basis of exponential-trigonometric functions of interparticle separations. Numerical results demonstrate high efficiency and versatility of the new method.
△ Less
Submitted 4 March, 2002;
originally announced March 2002.
-
A Role of Initial Conditions in Spin-Glass Aging Experiments
Authors:
V. S. Zotev,
G. F. Rodriguez,
R. Orbach,
E. Vincent,
J. Hammann
Abstract:
Effect of initial conditions on aging properties of the spin-glass state is studied for a single crystal Cu:Mn 1.5 at %. It is shown that memory of the initial state, created by the cooling process, remains strong on all experimental time scales. Scaling properties of two relaxation functions, the TRM and the IRM (with $t_{w1}=0$ and $t_{w2}=t_{w}$), are compared in detail. The TRM decay exhibit…
▽ More
Effect of initial conditions on aging properties of the spin-glass state is studied for a single crystal Cu:Mn 1.5 at %. It is shown that memory of the initial state, created by the cooling process, remains strong on all experimental time scales. Scaling properties of two relaxation functions, the TRM and the IRM (with $t_{w1}=0$ and $t_{w2}=t_{w}$), are compared in detail. The TRM decay exhibits the well-known subaging behavior, with $μ<1$ and $t_{w}^{eff}>t_{w}$. The IRM relaxation demonstrates the superaging behavior, with $μ>1$ and $t_{w}^{eff}<t_{w}$. It is shown that an average over different initial conditions leads to systematic improvement in $t/t_{w}$ scaling. An effective barrier, describing influence of the initial state on spin-glass relaxation, is found to be almost independent of temperature. These results suggest that departures from full $t/t_{w}$ scaling, observed in aging experiments, are largely due to cooling effects.
△ Less
Submitted 22 February, 2002; v1 submitted 15 February, 2002;
originally announced February 2002.
-
Magnetic Field Scaling in Spin Glasses and the Mean-Field Theory
Authors:
V. S. Zotev,
R. Orbach
Abstract:
The scaling of the magnetic field dependence of the remanent magnetization for different temperatures and different spin-glass samples is studied. Particular attention is paid to the effect of the de Almeida-Thouless (AT) critical line on spin-glass dynamics. It is shown that results of the mean-field theory of aging phenomena, with two additional experimentally justified assumptions, predict…
▽ More
The scaling of the magnetic field dependence of the remanent magnetization for different temperatures and different spin-glass samples is studied. Particular attention is paid to the effect of the de Almeida-Thouless (AT) critical line on spin-glass dynamics. It is shown that results of the mean-field theory of aging phenomena, with two additional experimentally justified assumptions, predict $H/H_{AT}(T)$ scaling for remanent magnetization curves. Experiments on a single crystal Cu:Mn 1.5 at % sample in the temperature interval from $0.7T_{g}$ to $0.85T_{g}$ give results consistent with this scaling. Magnetization vs. field curves for different Cu:Mn and thiospinel samples also scale together. These experimental results support the predictions of the mean-field theory of aging phenomena.
△ Less
Submitted 14 January, 2002;
originally announced January 2002.
-
From Linear to Nonlinear Response in Spin Glasses: Importance of Mean-Field-Theory Predictions
Authors:
V. S. Zotev,
R. Orbach
Abstract:
Deviations from spin-glass linear response in a single crystal Cu:Mn 1.5 at % are studied for a wide range of changes in magnetic field, $ΔH$. Three quantities, the difference $TRM-(MFC-ZFC)$, the effective waiting time, $t_{w}^{eff}$, and the difference $TRM(t_{w})-TRM(t_{w}=0)$ are examined in our analysis. Three regimes of spin-glass behavior are observed as $ΔH$ increases. Lines in the…
▽ More
Deviations from spin-glass linear response in a single crystal Cu:Mn 1.5 at % are studied for a wide range of changes in magnetic field, $ΔH$. Three quantities, the difference $TRM-(MFC-ZFC)$, the effective waiting time, $t_{w}^{eff}$, and the difference $TRM(t_{w})-TRM(t_{w}=0)$ are examined in our analysis. Three regimes of spin-glass behavior are observed as $ΔH$ increases. Lines in the $(T,ΔH)$ plane, corresponding to ``weak'' and ``strong'' violations of linear response under a change in magnetic field, are shown to have the same functional form as the de Almeida-Thouless critical line. Our results demonstrate the existence of a fundamental link between static and dynamic properties of spin glasses, predicted by the mean-field theory of aging phenomena.
△ Less
Submitted 31 December, 2001; v1 submitted 28 December, 2001;
originally announced December 2001.