-
HighNESS Conceptual Design Report: Volume I
Authors:
V. Santoro,
O. Abou El Kheir,
D. Acharya,
M. Akhyani,
K. H. Andersen,
J. Barrow,
P. Bentley,
M. Bernasconi,
M. Bertelsen,
Y. Bessler,
A. Bianchi,
G. Brooijmans,
L. Broussard,
T. Brys,
M. Busi,
D. Campi,
A. Chambon,
J. Chen,
V. Czamler,
P. Deen,
D. D. DiJulio,
E. Dian,
L. Draskovits,
K. Dunne,
M. El Barbari
, et al. (65 additional authors not shown)
Abstract:
The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world's most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron…
▽ More
The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world's most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2--20\,Å), very cold (VCN, 10--120\,Å), and ultracold (UCN, ${>}\,{500}$\,Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.
△ Less
Submitted 28 May, 2024; v1 submitted 29 September, 2023;
originally announced September 2023.
-
Particle Physics at the European Spallation Source
Authors:
H. Abele,
A. Alekou,
A. Algora,
K. Andersen,
S. Baessler,
L. Barron-Palos,
J. Barrow,
E. Baussan,
P. Bentley,
Z. Berezhiani,
Y. Bessler,
A. K. Bhattacharyya,
A. Bianchi,
J. Bijnens,
C. Blanco,
N. Blaskovic Kraljevic,
M. Blennow,
K. Bodek,
M. Bogomilov,
C. Bohm,
B. Bolling,
E. Bouquerel,
G. Brooijmans,
L. J. Broussard,
O. Buchan
, et al. (154 additional authors not shown)
Abstract:
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons…
▽ More
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).
△ Less
Submitted 30 January, 2024; v1 submitted 18 November, 2022;
originally announced November 2022.
-
The Development of the NNBAR Experiment
Authors:
F. Backman,
J. Barrow,
Y. Beßler,
A. Bianchi,
C. Bohm,
G. Brooijmans,
L. J. Broussard,
H. Calen,
J. Cederkäll,
J. I. M. Damian,
E. Dian,
D. D. Di Julio,
K. Dunne,
L. Eklund,
M. J. Ferreira,
P. Fierlinger,
U. Friman-Gayer,
C. Happe,
M. Holl,
T. Johansson,
Y. Kamyshkov,
E. Klinkby,
R. Kolevatov,
A. Kupsc,
B. Meirose
, et al. (18 additional authors not shown)
Abstract:
The NNBAR experiment for the European Spallation Source will search for free neutrons converting to antineutrons with a sensitivity improvement of three orders of magnitude compared to the last such search. This paper describes progress towards a conceptual design report for NNBAR. The design of a moderator, neutron reflector, beamline, shielding and annihilation detector is reported. The simulati…
▽ More
The NNBAR experiment for the European Spallation Source will search for free neutrons converting to antineutrons with a sensitivity improvement of three orders of magnitude compared to the last such search. This paper describes progress towards a conceptual design report for NNBAR. The design of a moderator, neutron reflector, beamline, shielding and annihilation detector is reported. The simulations used form part of a model which will be used for optimisation of the experiment design and quantification of its sensitivity.
△ Less
Submitted 19 September, 2022;
originally announced September 2022.
-
Development of a High Intensity Neutron Source at the European Spallation Source: The HighNESS project
Authors:
V. Santoro,
K. H. Andersen,
M. Bernasconi,
M. Bertelsen,
Y. Beßler,
D. Campi,
V. Czamler,
D. D. Di Julio,
E. Diane,
K. Dunne,
P. Fierlinger,
A. Gaye,
G. Gorini,
C. Happe,
T. Kittelmann,
E. B. Klinkby,
Z. Kokai,
R. Kolevatov,
B. Lauritzen,
R. Linander,
J. I. Marquez Damian,
B. Meirose,
F. Mezei,
D. Milstead,
G. Muhrer
, et al. (14 additional authors not shown)
Abstract:
The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that will operate the world's most powerful pulsed neutron source. Supported by a 3M Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source below the spallation target. Compa…
▽ More
The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that will operate the world's most powerful pulsed neutron source. Supported by a 3M Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source below the spallation target. Compared to the first source, located above the spallation target and designed for high cold and thermal brightness, the new source will provide higher intensity, and a shift to longer wavelengths in the spectral regions of cold (2 /- 20 Å), very cold (VCN, 10 /- 120 Å), and ultra cold (UCN, > 500 Å) neutrons. The core of the second source will consist of a large liquid deuterium moderator to deliver a high flux of cold neutrons and to serve secondary VCN and UCN sources, for which different options are under study. The features of these new sources will boost several areas of condensed matter research and will provide unique opportunities in fundamental physics. Part of the HighNESS project is also dedicated to the development of future instruments that will make use of the new source and will complement the initial suite of instruments in construction at ESS. The HighNESS project started in October 2020. In this paper, the ongoing developments and the results obtained in the first year are described.
△ Less
Submitted 8 April, 2022;
originally announced April 2022.
-
Nested mirror optics for neutron extraction, transport, and focusing
Authors:
Christoph Herb,
Oliver Zimmer,
Robert Georgii,
Peter Böni
Abstract:
Neutron scattering is a well-established tool for the investigation of the static and dynamic properties of condensed matter systems over a wide range of spatial and temporal scales. Many studies of high interest, however, can only be performed on small samples and typically require elaborate environments for variation of parameters such as temperature, magnetic field and pressure. To improve the…
▽ More
Neutron scattering is a well-established tool for the investigation of the static and dynamic properties of condensed matter systems over a wide range of spatial and temporal scales. Many studies of high interest, however, can only be performed on small samples and typically require elaborate environments for variation of parameters such as temperature, magnetic field and pressure. To improve the achievable signal-to-background ratio, focusing devices based on elliptic or parabolic neutron guides or Montel mirrors have been implemented. Here we report an experimental demonstration of a nested mirror optics (NMO), which overcomes some of the disadvantages of such devices. While even simpler than the original Wolter design, our compact assembly of elliptic mirrors images neutrons from a source to a target, minimizing geometric aberrations, gravitational effects and waviness-induced blurring. Experiments performed at MIRA at FRM-II demonstrate the expected focusing properties and a beam transport efficiency of 72 % for our first prototype. NMO seem particularly well-suited to i) extraction of neutrons from compact high-brilliance neutron moderators, ii) general neutron transport, and iii) focusing and polarizing neutrons. The phase space of the neutrons hitting a sample can be tailored on-line to the needed experimental resolution, resulting in small scattering backgrounds. As additional benefits, NMO situated far away from both the moderator and the sample are less susceptible to radiation damage and can easily be replaced. NMO enable a modular and physically transparent realization of beam lines for neutron physics similar to setups used in visible light optics.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
A Computing and Detector Simulation Framework for the HIBEAM/NNBAR Experimental Program at the ESS
Authors:
J. Barrow,
G. Brooijmans,
J. I. M. Damian,
D. DiJulio,
K. Dunne,
M. Frost,
E. Golubeva,
Y. Kamyshkov,
T. Kittelmann,
E. Klinkby,
Z. Kókai,
J. Makkinje,
B. Meirose,
D. Milstead,
A. Nepomuceno,
A. Oskarsson,
K. Ramic,
N. Rizzi,
V. Santoro,
S. Silverstein,
A. Takibayev,
R. Wagner,
S-C. Yiu,
L. Zanini,
O. Zimmer
Abstract:
The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source focusing on searches for baryon number violation via processes in which neutrons convert to antineutrons. This paper outlines the computing and detector simulation framework for the HIBEAM/NNBAR program. The simulation is based on predictions of neutron flux and neutronics together with signal and backgro…
▽ More
The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source focusing on searches for baryon number violation via processes in which neutrons convert to antineutrons. This paper outlines the computing and detector simulation framework for the HIBEAM/NNBAR program. The simulation is based on predictions of neutron flux and neutronics together with signal and background generation. A range of diverse simulation packages are incorporated, including Monte Carlo transport codes, neutron ray-tracing simulation packages, and detector simulation software. The common simulation package in which these elements are interfaced together is discussed. Data management plans and triggers are also described.
△ Less
Submitted 30 June, 2021;
originally announced June 2021.
-
Experimental Search for Non-Newtonian Forces in the Nanometer Scale with Slow Neutrons
Authors:
Y. Kamiya,
R. Cubitt,
L. Porcar,
O. Zimmer,
G. N. Kim,
S. Komamiya
Abstract:
Improved limits for new gravity-like short-range interactions, in which a scattering potential is modeled by the Yukawa-type parametrization, have been obtained by measuring the angular distribution of 6 Å neutrons scattering from atomic xenon gas. We have collected approximately $1.4 \times 10^8$ small-angle neutron scattering events. The data are interpreted as no evidence of new forces and show…
▽ More
Improved limits for new gravity-like short-range interactions, in which a scattering potential is modeled by the Yukawa-type parametrization, have been obtained by measuring the angular distribution of 6 Å neutrons scattering from atomic xenon gas. We have collected approximately $1.4 \times 10^8$ small-angle neutron scattering events. The data are interpreted as no evidence of new forces and show improved upper limits on the coupling strength in the interaction range of $0.3$ nm to $9$ nm. These improved constraints are also interpreted as new limits for a model, in which a charge of the new forces is expressed as a linear combination of the baryon number and the lepton number.
△ Less
Submitted 10 June, 2020;
originally announced June 2020.
-
New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the European Spallation Source
Authors:
A. Addazi,
K. Anderson,
S. Ansell,
K. Babu,
J. Barrow,
D. V. Baxter,
P. M. Bentley,
Z. Berezhiani,
R. Bevilacqua,
C. Bohm,
G. Brooijmans,
J. Broussard,
R. Biondi,
B. Dev,
C. Crawford,
A. Dolgov,
K. Dunne,
P. Fierlinger,
M. R. Fitzsimmons,
A. Fomin,
M. Frost,
S. Gardner,
A. Galindo-Uribarri,
E. Golubeva,
S. Girmohanta
, et al. (70 additional authors not shown)
Abstract:
The violation of Baryon Number, $\mathcal{B}$, is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR %experiment program is a proposed two-stage experiment at the European Spallation Source (ESS) to search for baryon numbe…
▽ More
The violation of Baryon Number, $\mathcal{B}$, is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR %experiment program is a proposed two-stage experiment at the European Spallation Source (ESS) to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron-antineutron oscillation ($n\rightarrow \bar{n}$) via mixing, neutron-antineutron oscillation via regeneration from a sterile neutron state ($n\rightarrow [n',\bar{n}'] \rightarrow \bar{n}$), and neutron disappearance ($n\rightarrow n'$); the effective $Δ\mathcal{B}=0$ process of neutron regeneration ($n\rightarrow [n',\bar{n}'] \rightarrow n$) is also possible. The program can be used to discover and characterise mixing in the neutron, antineutron, and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis, the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.
△ Less
Submitted 8 June, 2020;
originally announced June 2020.
-
Development of High Intensity Neutron Source at the European Spallation Source
Authors:
V. Santoro,
K. H. Andersen,
D. D. DiJulio,
E. B. Klinkby,
T. M. Miller,
D. Milstead,
G. Muhrer,
M. Stroble,
A. Takibayev,
L. Zanini,
O. Zimmer
Abstract:
The European Spallation Source being constructed in Lund, Sweden will provide the user community with a neutron source of unprecedented brightness. By 2025, a suite of 15 instruments will be served by a high-brightness moderator system placed above the spallation target. The ESS infrastructure, consisting of the proton linac, the target station, and the instrument halls, allows for implementation…
▽ More
The European Spallation Source being constructed in Lund, Sweden will provide the user community with a neutron source of unprecedented brightness. By 2025, a suite of 15 instruments will be served by a high-brightness moderator system placed above the spallation target. The ESS infrastructure, consisting of the proton linac, the target station, and the instrument halls, allows for implementation of a second source below the spallation target. We propose to develop a second neutron source with a high-intensity moderator able to (1) deliver a larger total cold neutron flux, (2) provide high intensities at longer wavelengths in the spectral regions of Cold (4-10 Å), Very Cold (10-40 Å), and Ultra Cold (several 100 Å) neutrons, as opposed to Thermal and Cold neutrons delivered by the top moderator. Offering both unprecedented brilliance, flux, and spectral range in a single facility, this upgrade will make ESS the most versatile neutron source in the world and will further strengthen the leadership of Europe in neutron science. The new source will boost several areas of condensed matter research such as imaging and spin-echo, and will provide outstanding opportunities in fundamental physics investigations of the laws of nature at a precision unattainable anywhere else. At the heart of the proposed system is a volumetric liquid deuterium moderator. Based on proven technology, its performance will be optimized in a detailed engineering study. This moderator will be complemented by secondary sources to provide intense beams of Very- and Ultra-Cold Neutrons.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
The PanEDM Neutron Electric Dipole Moment Experiment at the ILL
Authors:
David Wurm,
Douglas H. Beck,
Tim Chupp,
Skyler Degenkolb,
Katharina Fierlinger,
Peter Fierlinger,
Hanno Filter,
Sergey Ivanov,
Christopher Klau,
Michael Kreuz,
Eddy Lelièvre-Berna,
Tobias Lins,
Joachim Meichelböck,
Thomas Neulinger,
Robert Paddock,
Florian Röhrer,
Martin Rosner,
Anatolii P. Serebrov,
Jaideep Taggart Singh,
Rainer Stoepler,
Stefan Stuiber,
Michael Sturm,
Bernd Taubenheim,
Xavier Tonon,
Mark Tucker
, et al. (2 additional authors not shown)
Abstract:
The neutron's permanent electric dipole moment $d_n$ is constrained to below $3\times10^{-26} e~\text{cm}$ (90% C.L.) [ arXiv:hep-ex/0602020, arXiv:1509.04411 ], by experiments using ultracold neutrons (UCN). We plan to improve this limit by an order of magnitude or more with PanEDM, the first experiment exploiting the ILL's new UCN source SuperSUN. SuperSUN is expected to provide a high density o…
▽ More
The neutron's permanent electric dipole moment $d_n$ is constrained to below $3\times10^{-26} e~\text{cm}$ (90% C.L.) [ ar** factor and built-in coil system. No comagnetometer is needed for the first order-of-magnitude improvement in $d_n$, thanks to high magnetic stability and an assortment of sensors outside the UCN storage volumes. PanEDM will be commissioned and upgraded in parallel with SuperSUN, to take full advantage of the source's output in each phase. Commissioning is ongoing in 2019, and a new limit in the mid $10^{-27} e~\text{cm}$ range should be possible with two full reactor cycles of data in the commissioned apparatus.
△ Less
Submitted 20 November, 2019;
originally announced November 2019.
-
Improved determination of the $β$-$\overlineν_e$ angular correlation coefficient $a$ in free neutron decay with the $a$SPECT spectrometer
Authors:
M. Beck,
F. Ayala Guardia,
S. Baeßler,
M. Borg,
F. Glück,
W. Heil,
J. Kahlenberg,
M. Klopf,
G. Konrad,
R. Maisonobe,
R. Muñoz Horta,
C. Schmidt,
U. Schmidt,
M. Simson,
T. Soldner,
R. Virot,
A. Wunderle,
O. Zimmer
Abstract:
We report on a precise measurement of the electron-antineutrino angular correlation ($a$ coefficient) in free neutron beta-decay from the $a$SPECT experiment. The $a$ coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4$π$ by the $a$SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100 days run…
▽ More
We report on a precise measurement of the electron-antineutrino angular correlation ($a$ coefficient) in free neutron beta-decay from the $a$SPECT experiment. The $a$ coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4$π$ by the $a$SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100 days run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain $a = -0.10430(84)$ which is the most precise measurement of the neutron $a$ coefficient to date. From this, the ratio of axial-vector to vector coupling constants is derived giving $|λ| = 1.2677(28)$.
△ Less
Submitted 6 June, 2020; v1 submitted 13 August, 2019;
originally announced August 2019.
-
Design of the Magnet System of the Neutron Decay Facility PERC
Authors:
Xiangzun Wang,
Carmen Ziener,
Hartmut Abele,
Stefan Bodmaier,
Dirk Dubbers,
Jaqueline Erhart,
Alexander Hollering,
Erwin Jericha,
Jens Klenke,
Harald Fillunger,
Werner Heil,
Christine Klauser,
Gertrud Konrad,
Max Lamparth,
Thorsten Lauer,
Michael Klopf,
Reinhard Maix,
Bastian Märkisch,
Wilfried Mach,
Holger Mest,
Daniel Moser,
Alexander Pethoukov,
Lukas Raffelt,
Nataliya Rebrova,
Christoph Roick
, et al. (5 additional authors not shown)
Abstract:
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element $V_{ud}$ from neutron decay data and to search for new…
▽ More
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element $V_{ud}$ from neutron decay data and to search for new physics via new effective couplings. PERC's central component is a 12m long superconducting magnet system. It hosts an 8m long decay region in a uniform field. An additional high-field region selects the phase space of electrons and protons which can reach the detectors and largely improves systematic uncertainties. We discuss the design of the magnet system and the resulting properties of the magnetic field.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
Neutron lifetime measurements with the big gravitational trap for ultracold neutrons
Authors:
A. P. Serebrov,
E . A. Kolomensky,
A. K. Fomin,
I. A. Krasnoschekova,
A. V. Vassiljev,
D. M. Prudnikov,
I. V. Shoka,
A. V. Chechkin,
M. E. Chaikovskiy,
V. E. Varlamov,
S. N. Ivanov,
A. N. Pirozhkov,
P. Geltenbort,
O. Zimmer,
T. Jenke,
M. Van der Grinten,
M. Tucker
Abstract:
Neutron lifetime is one of the most important physical constants which determines parameters of the weak interaction and predictions of primordial nucleosynthesis theory. There remains the unsolved problem of a 3.9σ discrepancy between measurements of this lifetime using neutrons in beams and those with stored neutrons (UCN). In our experiment we measure the lifetime of neutrons trapped by Earth's…
▽ More
Neutron lifetime is one of the most important physical constants which determines parameters of the weak interaction and predictions of primordial nucleosynthesis theory. There remains the unsolved problem of a 3.9σ discrepancy between measurements of this lifetime using neutrons in beams and those with stored neutrons (UCN). In our experiment we measure the lifetime of neutrons trapped by Earth's gravity in an open-topped vessel. Two configurations of the trap geometry are used to change the mean frequency of UCN collisions with the surfaces - this is achieved by plunging an additional surface into the trap without breaking the vacuum. The trap walls are coated with a hydrogen-less fluorine-containing polymer to reduce losses of UCN. The stability of this coating to multiple thermal cycles between 80 K and 300 K was tested. At 80 K, the probability of UCN loss due to collisions with the trap walls is just 1.5% of the probability of beta-decay. The free neutron lifetime is determined by extrapolation to an infinitely large trap with zero collision frequency. The result of these measurements is 881.5 +/- 0.7_stat +/- 0.6_syst s which is consistent with the conventional value of 880.2 +/- 1.0 s presented by the Particle Data Group. Future prospects for this experiment are in further cooling to 10 K which will lead to an improved accuracy of measurement. In conclusion we present an analysis of currently-available data on various measurements of the neutron lifetime.
△ Less
Submitted 15 December, 2017;
originally announced December 2017.
-
Multi-mirror imaging optics for low-loss transport of divergent neutron beams and tailored wavelength spectra
Authors:
Oliver Zimmer
Abstract:
A neutron optical transport system is proposed which comprises nested short elliptical mirrors located halfway between two common focal points M and M'. It images cold neutrons from a diverging beam or a source with finite size at M by single reflections onto a spot of similar size at M'. Direct view onto the neutron source is blocked by a central absorber with little impact on the transported sol…
▽ More
A neutron optical transport system is proposed which comprises nested short elliptical mirrors located halfway between two common focal points M and M'. It images cold neutrons from a diverging beam or a source with finite size at M by single reflections onto a spot of similar size at M'. Direct view onto the neutron source is blocked by a central absorber with little impact on the transported solid angle. Geometric neutron losses due to source size can be kept small using modern supermirrors and distances M-M' of a few tens of metres. Very short flat mirrors can be used in practical implementations. Transport with a minimum of reflections remedies losses due to multiple reflections that are common in long elliptical neutron guides. Moreover, well-defined reflection angles lead to new possibilities for enhancing the spectral quality of primary beams, such as clear-cut discrimination of short neutron wavelengths or beam monochromation using bandpass supermirrors. Multi-mirror imaging systems may thus complement or even replace ordinary neutron guides, in particular at the European Spallation Source.
△ Less
Submitted 22 November, 2016;
originally announced November 2016.
-
Comparison of ultracold neutron sources for fundamental physics measurements
Authors:
G. Bison,
M. Daum,
K. Kirch,
B. Lauss,
D. Ries,
P. Schmidt-Wellenburg,
G. Zsigmond,
T. Brenner,
P. Geltenbort,
T. Jenke,
O. Zimmer,
M. Beck,
W. Heil,
J. Kahlenberg,
J. Karch,
K. Ross,
K. Eberhardt,
C. Geppert,
S. Karpuk,
T. Reich,
C. Siemensen,
Y. Sobolev,
N. Trautmann
Abstract:
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently o…
▽ More
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a 'standard' UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.
△ Less
Submitted 26 October, 2016;
originally announced October 2016.
-
Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array
Authors:
K. K. H. Leung,
P. Geltenbort,
S. Ivanov,
F. Rosenau,
O. Zimmer
Abstract:
Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used…
▽ More
Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $τ_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $τ_{\rm n}$ experiments with magnetically stored UCNs.
△ Less
Submitted 2 June, 2016;
originally announced June 2016.
-
Neutrons on a surface of liquid helium
Authors:
P. D. Grigoriev,
O. Zimmer,
T. Ziman,
A. D. Grigoriev
Abstract:
We investigate the possibility of ultracold neutron (UCN) storage in quantum states defined by the combined potentials of the Earth's gravity and the neutron optical repulsion by a horizontal surface of liquid helium. We analyse the stability of the lowest quantum state, which is most susceptible to perturbations due to surface excitations, against scattering by helium atoms in the vapor and by ex…
▽ More
We investigate the possibility of ultracold neutron (UCN) storage in quantum states defined by the combined potentials of the Earth's gravity and the neutron optical repulsion by a horizontal surface of liquid helium. We analyse the stability of the lowest quantum state, which is most susceptible to perturbations due to surface excitations, against scattering by helium atoms in the vapor and by excitations of the liquid, comprised of ripplons, phonons and surfons. This is an unusual scattering problem since the kinetic energy of the neutron parallel to the surface may be much greater than the binding energies perpendicular. The total scattering time constant of these UCNs at 0.7 K is found to exceed one hour, and rapidly increasing with decreasing temperature. Such low scattering rates should enable high-precision measurements of the scheme of discrete energy levels, thus providing improved access to short-range gravity. The system might also be useful for neutron beta-decay experiments. We also sketch new experimental concepts for level population and trap** of UCNs above a flat horizontal mirror.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Ultracold neutron production and up-scattering in superfluid helium between 1.1 K and 2.4 K
Authors:
K. K. H. Leung,
S. Ivanov,
F. M. Piegsa,
M. Simson,
O. Zimmer
Abstract:
Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the number of accumulated UCNs was counted to be $91,\!700 \pm 300$. From this, we derive a volumetric UCN production rate of…
▽ More
Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the number of accumulated UCNs was counted to be $91,\!700 \pm 300$. From this, we derive a volumetric UCN production rate of $(6.9 \pm 1.7)\,\mathrm{cm^{-3}\,s^{-1}}$, which includes a correction for losses in the converter during UCN extraction caused by a short storage time, but not accounting for UCN transport and detection efficiencies. The up-scattering rate of UCNs due to excitations in the superfluid was studied by scanning the temperature between 1.2-2.4 K. Using the temperature-dependent UCN production rate calculated from inelastic neutron scattering data in the analysis, the only UCN up-scattering process found to be present was from two-phonon scattering. Our analysis rules out contributions from the other scattering processes to $\lesssim 10\%$ of their predicted levels.
△ Less
Submitted 22 February, 2016; v1 submitted 27 July, 2015;
originally announced July 2015.
-
Experimental study of ultracold neutron production in pressurized superfluid helium
Authors:
P. Schmidt-Wellenburg,
J. Bossy,
E. Farhi,
M. Fertl,
K. K. H. Leung,
A. Rahli,
T. Soldner,
O. Zimmer
Abstract:
We have investigated experimentally the pressure dependence of the production of ultracold neutrons (UCN) in superfluid helium in the range from saturated vapor pressure to 20bar. A neutron velocity selector allowed the separation of underlying single-phonon and multiphonon pro- cesses by varying the incident cold neutron (CN) wavelength in the range from 3.5 to 10Å. The predicted pressure depende…
▽ More
We have investigated experimentally the pressure dependence of the production of ultracold neutrons (UCN) in superfluid helium in the range from saturated vapor pressure to 20bar. A neutron velocity selector allowed the separation of underlying single-phonon and multiphonon pro- cesses by varying the incident cold neutron (CN) wavelength in the range from 3.5 to 10Å. The predicted pressure dependence of UCN production derived from inelastic neutron scattering data was confirmed for the single-phonon excitation. For multiphonon based UCN production we found no significant dependence on pressure whereas calculations from inelastic neutron scattering data predict an increase of 43(6)% at 20bar relative to saturated vapor pressure. From our data we conclude that applying pressure to superfluid helium does not increase the overall UCN production rate at a typical CN guide.
△ Less
Submitted 29 July, 2015; v1 submitted 25 June, 2015;
originally announced June 2015.
-
A comparison of two magnetic ultra-cold neutron trap** concepts using a Halbach-octupole array
Authors:
K. Leung,
S. Ivanov,
F. Martin,
F. Rosenau,
M. Simson,
O. Zimmer
Abstract:
This paper describes a new magnetic trap for ultra-cold neutrons (UCNs) made from a 1.2 m long Halbach-octupole array of permanent magnets with an inner bore radius of 47 mm combined with an assembly of superconducting end coils and bias field solenoid. The use of the trap in a vertical, magneto-gravitational and a horizontal setup are compared in terms of the effective volume and ability to contr…
▽ More
This paper describes a new magnetic trap for ultra-cold neutrons (UCNs) made from a 1.2 m long Halbach-octupole array of permanent magnets with an inner bore radius of 47 mm combined with an assembly of superconducting end coils and bias field solenoid. The use of the trap in a vertical, magneto-gravitational and a horizontal setup are compared in terms of the effective volume and ability to control key systematic effects that need to be addressed in high precision neutron lifetime measurements.
△ Less
Submitted 17 March, 2015;
originally announced March 2015.
-
New measurements of neutron electric dipole moment with double chamber EDM spectrometer
Authors:
A. P. Serebrov,
E. A. Kolomenskiy,
A. N. Pirozhkov,
I. A. Krasnoshekova,
A. V. Vasiliev,
A. O. Polyushkin,
M. S. Lasakov,
A. N. Murashkin,
V. A. Solovey,
A. K. Fomin,
I. V. Shoka,
O. M. Zherebtsov,
P. Geltenbort,
S. N. Ivanov,
O. Zimmer,
E. B. Alexandrov,
S. P. Dmitriev,
N. A. Dovator
Abstract:
The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.
The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
Cooling neutrons using non-dispersive magnetic excitations
Authors:
Oliver Zimmer
Abstract:
A new method is proposed for cooling neutrons by inelastic magnetic scattering in weakly absorbing, cold paramagnetic systems. Kinetic neutron energy is removed in constant decrements determined by the Zeeman energy of paramagnetic atoms or ions in an external magnetic field, or by zero-field level splittings in magnetic molecules. Analytical solutions of the stationary neutron transport equation…
▽ More
A new method is proposed for cooling neutrons by inelastic magnetic scattering in weakly absorbing, cold paramagnetic systems. Kinetic neutron energy is removed in constant decrements determined by the Zeeman energy of paramagnetic atoms or ions in an external magnetic field, or by zero-field level splittings in magnetic molecules. Analytical solutions of the stationary neutron transport equation are given using inelastic neutron scattering cross sections derived in an appendix. They neglect any inelastic process except the paramagnetic scattering and hence still underestimate very-cold neutron densities. Molecular oxygen with its triplet ground state appears particularly promising, notably as a host in fully deuterated oxygen-clathrate hydrate, or more exotically, in dry oxygen-He4 van der Waals clusters. At a neutron temperature about 6 K, for which neutron conversion to ultra-cold neutrons by single-phonon emission in pure superfluid He4 works best, conversion rates due to paramagnetic scattering in the clathrate are found to be a factor 9 larger. While in conversion the neutron imparts only a single energy quantum to the medium, the multi-step paramagnetic cooling cascade leads to further strong enhancements of very-cold neutron densities, e.g., by a factor 14 (57) for an initial neutron temperature of 30 K (100 K), for the moderator held at about 1.3 K. Due to a favorable Bragg cutoff of the oxygen-clathrate the cascade-cooling can take effect in a moderator with linear extensions smaller than a meter. The paramagnetic cooling mechanism may offer benefits in novel intense sources of very cold neutrons and for enhancing production of ultra-cold neutrons.
△ Less
Submitted 14 June, 2014;
originally announced June 2014.
-
New source for ultracold neutrons at the Institut Laue-Langevin
Authors:
F. M. Piegsa,
M. Fertl,
S. N. Ivanov,
M. Kreuz,
K. K. H. Leung,
P. Schmidt-Wellenburg,
T. Soldner,
O. Zimmer
Abstract:
A new intense superthermal source for ultracold neutrons (UCN) has been installed at a dedicated beam line at the Institut Laue-Langevin. Incident neutrons with a wavelength of 0.89 nm are converted to UCN in a five liter volume filled with superfluid $^4$He at a temperature of about 0.7 K. The UCN can be extracted to room temperature experiments. We present the cryogenic setup of the source, a ch…
▽ More
A new intense superthermal source for ultracold neutrons (UCN) has been installed at a dedicated beam line at the Institut Laue-Langevin. Incident neutrons with a wavelength of 0.89 nm are converted to UCN in a five liter volume filled with superfluid $^4$He at a temperature of about 0.7 K. The UCN can be extracted to room temperature experiments. We present the cryogenic setup of the source, a characterization of the cold neutron beam, and UCN production measurements, where a UCN density in the production volume of at least 55 per cm$^3$ was determined.
△ Less
Submitted 14 April, 2014;
originally announced April 2014.
-
New measurements of neutron electric dipole moment
Authors:
A. P. Serebrov,
E. A. Kolomenskiy,
A. N. Pirozhkov,
I. A. Krasnoshekova,
A. V. Vasiliev,
A. O. Polyushkin,
M. S. Lasakov,
A. K. Fomin,
I. V. Shoka,
V. A. Solovey,
O. M. Zherebtsov,
P. Geltenbort,
O. Zimmer,
S. N. Ivanov,
E. B. Alexandrov,
S. P. Dmitriev,
N. A. Dovator
Abstract:
We report a new measurement of the neutron electric dipole moment with the PNPI EDM spectrometer using the ultracold neutron source PF2 at the research reactor of the ILL. Its first results can be interpreted as a limit on the neutron EDM of $|d_{\rm n}| < 5.5 \times 10^{-26} \rm{e} \cdot \rm{cm}$ (90% confidence level).
We report a new measurement of the neutron electric dipole moment with the PNPI EDM spectrometer using the ultracold neutron source PF2 at the research reactor of the ILL. Its first results can be interpreted as a limit on the neutron EDM of $|d_{\rm n}| < 5.5 \times 10^{-26} \rm{e} \cdot \rm{cm}$ (90% confidence level).
△ Less
Submitted 16 December, 2013; v1 submitted 21 October, 2013;
originally announced October 2013.
-
Ultracold neutron accumulation in a superfluid-helium converter with magnetic multipole reflector
Authors:
O. Zimmer,
R. Golub
Abstract:
We analyze accumulation of ultracold neutrons (UCN) in a superfluid-helium converter vessel surrounded by a magnetic multipole reflector. We solved the spin-dependent rate equation, employing formulas valid for adiabatic spin transport of trapped UCN in mechanical equilibrium. Results for saturation UCN densities are obtained in dependence of order and strength of the multipolar field. The additio…
▽ More
We analyze accumulation of ultracold neutrons (UCN) in a superfluid-helium converter vessel surrounded by a magnetic multipole reflector. We solved the spin-dependent rate equation, employing formulas valid for adiabatic spin transport of trapped UCN in mechanical equilibrium. Results for saturation UCN densities are obtained in dependence of order and strength of the multipolar field. The addition of magnetic storage to neutron optical potentials can increase the density and energy of the low field seeking UCN produced and serves to mitigate the effects of wall losses on the source performance. It also can provide a highly polarized sample of UCN without need to polarize the neutron beam incident on the converter. This work was performed in preparation of the UCN source project SuperSUN at the ILL.
△ Less
Submitted 4 March, 2015; v1 submitted 8 March, 2013;
originally announced March 2013.
-
V_{ud} from neutron beta decay
Authors:
Oliver Zimmer
Abstract:
The experimental determination of V_{ud} from neutron beta decay requires accurate values of the neutron lifetime and the ratio of the weak axial-vector to vector coupling constants of the nucleon. The latter is derived from measurements of angular correlation coefficients in the differential decay probability, such as the beta asymmetry parameter A, the neutrino-electron angular correlation coeff…
▽ More
The experimental determination of V_{ud} from neutron beta decay requires accurate values of the neutron lifetime and the ratio of the weak axial-vector to vector coupling constants of the nucleon. The latter is derived from measurements of angular correlation coefficients in the differential decay probability, such as the beta asymmetry parameter A, the neutrino-electron angular correlation coefficient a, or the parameter C of the proton asymmetry. As a probe free from nuclear structure corrections the decay of the free neutron has the potential to provide the most accurate value of V_{ud}. Towards that end however, the experimental sensitivity still needs to be further improved to become competitive with superallowed nuclear beta decays. This contribution briefly reviews the current status of those neutron decay studies relevant for the determination of V_{ud}.
△ Less
Submitted 18 February, 2013; v1 submitted 9 January, 2013;
originally announced January 2013.
-
Polarized Neutron Laue Diffraction on a Crystal Containing Dynamically Polarized Proton Spins
Authors:
F. M. Piegsa,
M. Karlsson,
B. van den Brandt,
C. J. Carlile,
E. M. Forgan,
P. Hautle,
J. A. Konter,
G. J. McIntyre,
O. Zimmer
Abstract:
We report on a polarized-neutron Laue diffraction experiment on a single crystal of neodynium doped lanthanum magnesium nitrate hydrate containing polarized proton spins. By using dynamic nuclear polarization to polarize the proton spins, we demonstrate that the intensities of the Bragg peaks can be enhanced or diminished significantly, whilst the incoherent background, due to proton spin disorder…
▽ More
We report on a polarized-neutron Laue diffraction experiment on a single crystal of neodynium doped lanthanum magnesium nitrate hydrate containing polarized proton spins. By using dynamic nuclear polarization to polarize the proton spins, we demonstrate that the intensities of the Bragg peaks can be enhanced or diminished significantly, whilst the incoherent background, due to proton spin disorder, is reduced. It follows that the method offers unique possibilities to tune continuously the contrast of the Bragg reflections and thereby represents a new tool for increasing substantially the signal-to-noise ratio in neutron diffraction patterns of hydrogenous matter.
△ Less
Submitted 9 October, 2012;
originally announced October 2012.
-
Observability of an induced electric dipole moment of the neutron from nonlinear QED
Authors:
O. Zimmer,
C. A. Dominguez,
H. Falomir,
M. Loewe
Abstract:
It has been shown recently that a neutron placed in an external quasistatic electric field develops an induced electric dipole moment $\mathbf{p}_{\mathrm{IND}}$ due to quantum fluctuations in the QED vacuum. A feasible experiment which could detect such an effect is proposed and described here. It is shown that the peculiar angular dependence of $\mathbf{p}_{\mathrm{IND}}$ on the orientation of t…
▽ More
It has been shown recently that a neutron placed in an external quasistatic electric field develops an induced electric dipole moment $\mathbf{p}_{\mathrm{IND}}$ due to quantum fluctuations in the QED vacuum. A feasible experiment which could detect such an effect is proposed and described here. It is shown that the peculiar angular dependence of $\mathbf{p}_{\mathrm{IND}}$ on the orientation of the neutron spin leads to a characteristic asymmetry in polarized neutron scattering by heavy nuclei. This asymmetry can be of the order of $10^{-3}$ for neutrons with epithermal energies. For thermalized neutrons from a hot moderator one still expects experimentally accessible values of the order of $10^{-4}$. The contribution of the induced effect to the neutron scattering length is expected to be only one order of magnitude smaller than that due to the neutron polarizability from its quark substructure. The experimental observation of this scattering asymmetry would be the first ever signal of nonlinearity in electrodynamics due to quantum fluctuations in the QED vacuum.
△ Less
Submitted 7 April, 2011;
originally announced April 2011.
-
Search for macroscopic CP violating forces using a neutron EDM spectrometer
Authors:
A. P. Serebrov,
O. Zimmer,
P. Geltenbort,
A. K. Fomin,
S. N. Ivanov,
E. A. Kolomensky,
I. A. Krasnoshekova,
M. S. Lasakov,
V. M. Lobashev,
A. N. Pirozhkov,
V. E. Varlamov,
A. V. Vasiliev,
O. M. Zherebtsov,
E. B. Aleksandrov,
S. P. Dmitriev,
N. A. Dovator
Abstract:
The search for CP violating forces between nucleons in the so-called axion window of force ranges lam between 2x10^-5 m and 0.02 m is interesting because only little experimental information is available there. Axion-like particles would induce a pseudo-magnetic field for neutrons close to bulk matter. A laboratory search investigates neutron spin precession close to a heavy mirror using ultraco…
▽ More
The search for CP violating forces between nucleons in the so-called axion window of force ranges lam between 2x10^-5 m and 0.02 m is interesting because only little experimental information is available there. Axion-like particles would induce a pseudo-magnetic field for neutrons close to bulk matter. A laboratory search investigates neutron spin precession close to a heavy mirror using ultracold neutrons in a magnetic resonance spectrometer. From the absence of a shift of the magnetic resonance we established new constraints on the coupling strength of axion-like particles in terms of the product gs x gp of scalar and pseudo-scalar dimensionless constants, as a function of the force range lam, gs x gp x lam^2 <= 2x10-21 [cm^2] (C.L.95%) for 10^-4 cm < lam < 1 cm. For 0.1 cm < lam < 1 cm previous limits are improved by 4 to 5 orders of magnitude.
△ Less
Submitted 11 December, 2009;
originally announced December 2009.
-
UCN production by multiphonon processes in superfluid Helium under pressure
Authors:
P. Schmidt-Wellenburg,
K. H. Andersen,
O. Zimmer
Abstract:
Cold neutrons are converted to ultra-cold neutrons (UCN) by the excitation of a single phonon or multiphonons in superfluid helium. The dynamic scattering function S(q, omega) of the superfluid helium strongly depends on pressure, leading to a pressure- dependent differential UCN production rate. A phenomenological expression for the multiphonon part of the scattering function s(lambda) describi…
▽ More
Cold neutrons are converted to ultra-cold neutrons (UCN) by the excitation of a single phonon or multiphonons in superfluid helium. The dynamic scattering function S(q, omega) of the superfluid helium strongly depends on pressure, leading to a pressure- dependent differential UCN production rate. A phenomenological expression for the multiphonon part of the scattering function s(lambda) describing UCN production has been derived from inelastic neutron scattering data. When combined with the production rate from single phonon processes this allows us to calculate the UCN production for any incident neutron flux. For calculations of the UCN production from single phonon processes we propose to use the values for S*(SVP) = 0.118(8) and S*(20 bar) = 0.066(6). As an example we will calculate the expected UCN production rate at the cold neutron beam for fundamental physics PF1b at the Institut Laue Langevin. We conclude that UCN production in superfluid helium under pressure is not attractive.
△ Less
Submitted 29 January, 2009; v1 submitted 26 November, 2008;
originally announced November 2008.
-
Measuring the proton spectrum in neutron decay - latest results with aSPECT
Authors:
M. Simson,
F. Ayala Guardia,
S. Baeßler,
M. Borg,
F. Glück,
W. Heil,
I. Konorov,
G. Konrad,
R. Muñoz Horta,
K. K. H. Leung,
Yu. Sobolev,
T. Soldner,
H. -F. Wirth,
O. Zimmer
Abstract:
The retardation spectrometer aSPECT was built to measure the shape of the proton spectrum in free neutron decay with high precision. This allows us to determine the antineutrino electron angular correlation coefficient a. We aim for a precision more than one order of magnitude better than the present best value, which is Delta_a /a = 5%.
In a recent beam time performed at the Institut Laue-Lan…
▽ More
The retardation spectrometer aSPECT was built to measure the shape of the proton spectrum in free neutron decay with high precision. This allows us to determine the antineutrino electron angular correlation coefficient a. We aim for a precision more than one order of magnitude better than the present best value, which is Delta_a /a = 5%.
In a recent beam time performed at the Institut Laue-Langevin during April / May 2008 we reached a statistical accuracy of about 2% per 24 hours measurement time. Several systematic effects were investigated experimentally. We expect the total relative uncertainty to be well below 5%.
△ Less
Submitted 24 November, 2008;
originally announced November 2008.
-
Progress Towards A Permanent Octupole Magnetic Ultra-Cold Neutron Trap for Lifetime Measurements
Authors:
Kent Leung,
Oliver Zimmer
Abstract:
The current knowledge of the neutron $β$-decay lifetime has come under scrutiny as of late due to large disagreements between recent precise measurements. Measurements using magnetically trapped Ultra-Cold Neutrons (UCNs) offer the possibility of storage without spurious losses which can provide a reliable value for the neutron lifetime. The progress towards realizing a neutron lifetime measurem…
▽ More
The current knowledge of the neutron $β$-decay lifetime has come under scrutiny as of late due to large disagreements between recent precise measurements. Measurements using magnetically trapped Ultra-Cold Neutrons (UCNs) offer the possibility of storage without spurious losses which can provide a reliable value for the neutron lifetime. The progress towards realizing a neutron lifetime measurement using a Ioffe-type trap made with a Halbach-type permanent octupole magnet is presented here. The experimental procedure extracts a gas of UCNs into vacuum, which reduces many known channels of neutron losses, and detects the neutron decays via in-situ detection of the produced protons.
△ Less
Submitted 5 February, 2009; v1 submitted 12 November, 2008;
originally announced November 2008.
-
Ultracold-neutron infrastructure for the gravitational spectrometer GRANIT
Authors:
P. Schmidt-Wellenburg,
K. H. Andersen,
P. Courtois,
M. Kreuz,
S. Mironov,
V. V. Nesvizhevsky,
G. Pignol,
K. V. Protasov,
T. Soldner,
F. Vezzu,
O. Zimmer
Abstract:
The gravitational spectrometer GRANIT will be set up at the Institut Laue Langevin. It will profit from the high ultracold neutron density produced by a dedicated source. A monochromator made of crystals from graphite intercalated with potassium will provide a neutron beam with 0.89 nm incident on the source. The source employs superthermal conversion of cold neutrons in superfluid helium, in a…
▽ More
The gravitational spectrometer GRANIT will be set up at the Institut Laue Langevin. It will profit from the high ultracold neutron density produced by a dedicated source. A monochromator made of crystals from graphite intercalated with potassium will provide a neutron beam with 0.89 nm incident on the source. The source employs superthermal conversion of cold neutrons in superfluid helium, in a vessel made from BeO ceramics with Be windows. A special extraction technique has been tested which feeds the spectrometer only with neutrons with a vertical velocity component v < 20 cm/s, thus kee** the density in the source high. This new source is expected to provide a density of up to 800 1/cm3 for the spectrometer.
△ Less
Submitted 29 January, 2009; v1 submitted 11 November, 2008;
originally announced November 2008.
-
Constraining spin-dependent short range interactions using neutron spin precession close to a mirror
Authors:
O. Zimmer
Abstract:
Spin-dependent short range interactions of free neutrons with matter may be searched for in various ways. This short note discusses pseudomagnetic precession of trapped ultracold neutrons in vicinity to bulk matter, which should be several orders of magnitude more sensitive than any other method proposed so far.
Spin-dependent short range interactions of free neutrons with matter may be searched for in various ways. This short note discusses pseudomagnetic precession of trapped ultracold neutrons in vicinity to bulk matter, which should be several orders of magnitude more sensitive than any other method proposed so far.
△ Less
Submitted 17 October, 2008;
originally announced October 2008.
-
Search for neutron - mirror neutron oscillations in a laboratory experiment with ultracold neutrons
Authors:
A. P. Serebrov,
E. B. Aleksandrov,
N. A. Dovator,
S. P. Dmitriev,
A. K. Fomin,
P. Geltenbort,
A. G. Kharitonov,
I. A. Krasnoschekova,
M. S. Lasakov,
A. N. Murashkin,
G. E. Shmelev,
V. E. Varlamov,
A. V. Vassiljev,
O. M. Zherebtsov,
O. Zimmer
Abstract:
Mirror matter is considered as a candidate for dark matter. In connection with this an experimental search for neutron - mirror neutron (nn') transitions has been carried out using storage of ultracold neutrons in a trap with different magnetic fields. As a result, a new limit for the neutron - mirror neutron oscillation time has been obtained, tau_osc >= 448 s (90% C.L.), assuming that there is…
▽ More
Mirror matter is considered as a candidate for dark matter. In connection with this an experimental search for neutron - mirror neutron (nn') transitions has been carried out using storage of ultracold neutrons in a trap with different magnetic fields. As a result, a new limit for the neutron - mirror neutron oscillation time has been obtained, tau_osc >= 448 s (90% C.L.), assuming that there is no mirror magnetic field larger than 100 nT. Besides a first attempt to obtain some restriction for mirror magnetic field has been done.
△ Less
Submitted 11 February, 2009; v1 submitted 29 September, 2008;
originally announced September 2008.
-
Accumulation and extraction of ultracold neutrons from a superfluid helium converter coated with fluorinated grease
Authors:
O. Zimmer,
P. Schmidt-Wellenburg,
M. Assmann,
M. Fertl,
J. Klenke,
S. Mironov,
H. -F. Wirth,
B. van den Brandt
Abstract:
We report experiments on the production of ultracold neutrons (UCN) in a converter of superfluid helium coated with fluorinated grease. We employed our technique of window-free extraction of accumulated UCN from the helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. The time constant for UCN passage through the same extraction aperture…
▽ More
We report experiments on the production of ultracold neutrons (UCN) in a converter of superfluid helium coated with fluorinated grease. We employed our technique of window-free extraction of accumulated UCN from the helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. The time constant for UCN passage through the same extraction aperture as in a previous experiment was a factor two shorter, despite a lower mean velocity of the accumulated UCN in the present experiments. A time-of-flight measurement of the cold neutron spectrum incident on the converter allowed us to estimate the multi-phonon contribution to the UCN production. The UCN production rate inferred from two methods agrees with the theoretical expectation.
△ Less
Submitted 31 January, 2008;
originally announced January 2008.
-
Measurement of the parity-violating triton emission asymmetry in the reaction 6Li(n,alfa)3H with polarised cold neutrons
Authors:
V. A. Vesna,
Yu. M. Gledenov,
V. V. Nesvizhevsky,
A. K. Petoukhov,
P. V. Sedyshev,
T. Soldner,
O. Zimmer,
E. V. Shulgina
Abstract:
We describe measurements of the parity-violating (P-odd) triton emission asymmetry coefficient in the 6Li(n,alfa)3H reaction with polarised cold neutrons. Experiments were carried out at the Petersburg Nuclear Physics Institute (Gatchina, Russia) and at the Institut Laue-Langevin (Grenoble, France). We employed an ionisation chamber in a configuration allowing us to suppress the left-right asymm…
▽ More
We describe measurements of the parity-violating (P-odd) triton emission asymmetry coefficient in the 6Li(n,alfa)3H reaction with polarised cold neutrons. Experiments were carried out at the Petersburg Nuclear Physics Institute (Gatchina, Russia) and at the Institut Laue-Langevin (Grenoble, France). We employed an ionisation chamber in a configuration allowing us to suppress the left-right asymmetry well below 10^(-8). A test for a false asymmetry due to eventual target impurities ("zero test") resulted in the value (0.0+-0.5)x10^(-8). As final result we obtained P-odd effect (-8.6+-2.0)x10^(-8).
△ Less
Submitted 19 October, 2007;
originally announced October 2007.
-
A clean, bright, and versatile source of neutron decay products
Authors:
D. Dubbers,
H. Abele,
S. Baessler,
B. Maerkisch,
M. Schumann,
T. Soldner,
O. Zimmer
Abstract:
We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay…
▽ More
We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay electrons and protons, under well-defined and precisely variable conditions, which can be well separated from the cold neutron beam. In this way a general-purpose source of neutron decay products is obtained which can be used for various different experiments in neutron decay correlation spectroscopy. A gain in phase space density of several orders of magnitude can be achieved with PERC, as compared to existing neutron decay spectrometers. Neutron beam related background is separately measurable in PERC, and magnetic mirror effects on the charged neutron decay products and edge effects in the active neutron beam volume are both strongly suppressed. Therefore the spectra and angular distributions of the emerging decay particles will be distortion-free on the level of 10^-4, more than 10 times better than achieved today.
△ Less
Submitted 27 September, 2007;
originally announced September 2007.
-
A source of ultra-cold neutrons for the gravitational spectrometer GRANIT
Authors:
P. Schmidt-Wellenburg,
P. Geltenbort,
V. V. Nesvizhevsky,
C. Plonka,
T. Soldner,
F. Vezzu,
O. Zimmer
Abstract:
We present the status of the development of a dedicated high density ultra-cold neutron (UCN) source dedicated to the gravitational spectrometer GRANIT. The source employs superthermal conversion of cold neutrons to UCN in superfluid helium. Tests have shown that UCN produced inside the liquid can be extracted into vacuum. Furthermore a dedicated neutron selection channel was tested to maintain…
▽ More
We present the status of the development of a dedicated high density ultra-cold neutron (UCN) source dedicated to the gravitational spectrometer GRANIT. The source employs superthermal conversion of cold neutrons to UCN in superfluid helium. Tests have shown that UCN produced inside the liquid can be extracted into vacuum. Furthermore a dedicated neutron selection channel was tested to maintain high initial density and extract only neutrons with a vertical velocity component 20 cm/s for the spectrometer. This new source would have a phase-space density of 0.18 cm-3(m/s)-3 for the spectrometer.
△ Less
Submitted 21 August, 2007; v1 submitted 10 August, 2007;
originally announced August 2007.
-
Experimental search for neutron - mirror neutron oscillations using storage of ultracold neutrons
Authors:
A. P. Serebrov,
E. B. Aleksandrov,
N. A. Dovator,
S. P. Dmitriev,
A. K. Fomin,
P. Geltenbort,
A. G. Kharitonov,
I. A. Krasnoschekova,
M. S. Lasakov,
A. N. Murashkin,
G. E. Shmelev,
V. E. Varlamov,
A. V. Vassiljev,
O. M. Zherebtsov,
O. Zimmer
Abstract:
The idea of a hidden sector of mirror partners of elementary particles has attracted considerable interest as a possible candidate for dark matter. Recently it was pointed out by Berezhiani and Bento that the present experimental data cannot exclude the possibility of a rapid oscillation of the neutron n to a mirror neutron n' with oscillation time much smaller than the neutron lifetime. A dedic…
▽ More
The idea of a hidden sector of mirror partners of elementary particles has attracted considerable interest as a possible candidate for dark matter. Recently it was pointed out by Berezhiani and Bento that the present experimental data cannot exclude the possibility of a rapid oscillation of the neutron n to a mirror neutron n' with oscillation time much smaller than the neutron lifetime. A dedicated search for vacuum transitions n->n' has to be performed at weak magnetic field, where both states are degenerate. We report the result of our experiment, which compares rates of ultracold neutrons after storage at a weak magnetic field well below 20 nT and at a magnetic field strong enough to suppress the seeked transitions. We obtain a new limit for the oscillation time of n-n' transitions, tau_osc (90% C.L.) > 414 s. The corresponding limit for the mixing energy of the normal and mirror neutron states is delta_m (90% C.L.) < 1.5x10-18 eV.
△ Less
Submitted 25 June, 2007;
originally announced June 2007.
-
A superfluid helium converter for accumulation and extraction of ultracold neutrons
Authors:
O. Zimmer,
K. Baumann,
M. Fertl,
B. Franke,
S. Mironov,
C. Plonka,
D. Rich,
P. Schmidt-Wellenburg,
H. -F. Wirth,
B. van den Brandt
Abstract:
We report the first successful extraction of accumulated ultracold neutrons (UCN) from a converter of superfluid helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. Windowless UCN extraction is performed in vertical direction through a mechanical cold valve. This prototype of a versatile UCN source is comprised of a novel cryostat desig…
▽ More
We report the first successful extraction of accumulated ultracold neutrons (UCN) from a converter of superfluid helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. Windowless UCN extraction is performed in vertical direction through a mechanical cold valve. This prototype of a versatile UCN source is comprised of a novel cryostat designed to keep the source portable and to allow for rapid cooldown. We measured time constants for UCN storage and extraction into a detector at room temperature, with the converter held at various temperatures between 0.7 and 1.3 K. The UCN production rate inferred from the count rate of extracted UCN is close to the theoretical expectation.
△ Less
Submitted 27 May, 2007;
originally announced May 2007.
-
Efficient extraction of a collimated ultra-cold neutron beam using diffusive channels
Authors:
P. Schmidt-Wellenburg,
J. Barnard,
P. Geltenbort,
V. V. Nesvizhevsky,
C. Plonka,
T. Soldner,
O. Zimmer
Abstract:
We present a first experimental demonstration of a new method to extract a well-collimated beam of ultra-cold neutrons (UCN) from a storage vessel. Neutrons with too large divergence are not removed from the beam by an absorbing collimation, but a diffuse or semidiffuse channel with high Fermi potential reflects them back into the vessel. This avoids unnecessary losses and keeps the storage time…
▽ More
We present a first experimental demonstration of a new method to extract a well-collimated beam of ultra-cold neutrons (UCN) from a storage vessel. Neutrons with too large divergence are not removed from the beam by an absorbing collimation, but a diffuse or semidiffuse channel with high Fermi potential reflects them back into the vessel. This avoids unnecessary losses and keeps the storage time high, which may be beneficial when the vessel is part of a UCN source with long buildup time of a high UCN density.
△ Less
Submitted 7 March, 2007;
originally announced March 2007.
-
Comment to "Observation of the neutron radiative decay" by R.U. Khafizov et al., published in JETP Letters 83 (2006) 5 (Pis'ma v ZhETF 83 (2006) 7)
Authors:
N. Severijns,
O. Zimmer,
H. -F. Wirth,
D. Rich
Abstract:
The commented manuscript was submitted for publication without informing at least four of the other authors, viz. N. Severijns, O. Zimmer, H.-F. Wirth and D. Rich. This violates our rights as collaborators. The analysis presented and the manuscript itself have not been discussed and have also not been approved by the entire collaboration prior to submission. Besides this formal incorrectness, we…
▽ More
The commented manuscript was submitted for publication without informing at least four of the other authors, viz. N. Severijns, O. Zimmer, H.-F. Wirth and D. Rich. This violates our rights as collaborators. The analysis presented and the manuscript itself have not been discussed and have also not been approved by the entire collaboration prior to submission. Besides this formal incorrectness, we also criticise the content of the paper.
△ Less
Submitted 19 July, 2006;
originally announced July 2006.
-
Comment about constraints on nanometer-range modifications to gravity from low-energy neutron experiments
Authors:
O. Zimmer,
N. Kaiser
Abstract:
A topic of present interest is the application of experimentally observed quantum mechanical levels of ultra-cold neutrons in the earth's gravitational field for searching short-range modifications to gravity. A constraint on new forces in the nanometer-range published by Nesvizhevsky and Protasov follows from inadequate modelling of the interaction potential of a neutron with a mirror wall. Lim…
▽ More
A topic of present interest is the application of experimentally observed quantum mechanical levels of ultra-cold neutrons in the earth's gravitational field for searching short-range modifications to gravity. A constraint on new forces in the nanometer-range published by Nesvizhevsky and Protasov follows from inadequate modelling of the interaction potential of a neutron with a mirror wall. Limits by many orders of magnitude better were already derived long ago from the consistency of experiments on the neutron-electron interaction.
△ Less
Submitted 14 February, 2006;
originally announced February 2006.
-
Discovery of the neutron radiative decay
Authors:
R. U. Khafizov,
N. Severijns,
O. Zimmer,
H. -F. Wirth,
D. Rich,
S. V. Tolokonnikov,
V. A. Solovei,
M. R. Kolhidashvili
Abstract:
The aim of this work is experimental discovery and research of a rare neutron mode, the radiative beta-decay, where a new particle, the radiative gamma-quantum, is formed along with the expected decay products beta-electron, recoil proton and antineutrino. The discovery of this rare neutron decay mode was conducted through identification of triple coincidences events: simultaneous registration o…
▽ More
The aim of this work is experimental discovery and research of a rare neutron mode, the radiative beta-decay, where a new particle, the radiative gamma-quantum, is formed along with the expected decay products beta-electron, recoil proton and antineutrino. The discovery of this rare neutron decay mode was conducted through identification of triple coincidences events: simultaneous registration of beta electron, proton and radiative gamma-quantum. The ordinary neutron decay was registered by double coincidences of beta electron and recoil proton. The ratio of triple to double coincidences is connected with relative intensity of radiative neutron decay (branching ratio - B.R.) B.R. = (3.2+1.6)10-3 (with 90 % C.L. and in the gamma energy region greater than 35 keV), which we are the first in the world to measure during the second and third cycles on FRMII (TUM, Germany) in Summer 2005. This value of B.R. is consistent with standard electroweak theory.
△ Less
Submitted 16 May, 2006; v1 submitted 30 November, 2005;
originally announced December 2005.
-
The spin-dependent nd scattering length - a proposed high-accuracy measurement
Authors:
B. van den Brandt,
H. W. Griesshammer,
P. Hautle,
J. Kohlbrecher,
J. A. Konter,
O. Zimmer
Abstract:
The understanding of few-nucleon systems at low energies is essential, e.g. for accurate predictions of element abundances in big-bang and stellar fusion. Novel effective field theories, taking only nucleons, or nucleons and pions as explicit degrees of freedom, provide a systematic approach, permitting an estimate of theoretical uncertainties. Basic constants parameterising the short range phys…
▽ More
The understanding of few-nucleon systems at low energies is essential, e.g. for accurate predictions of element abundances in big-bang and stellar fusion. Novel effective field theories, taking only nucleons, or nucleons and pions as explicit degrees of freedom, provide a systematic approach, permitting an estimate of theoretical uncertainties. Basic constants parameterising the short range physics are derived from only a handful of experimental values. The doublet neutron scattering length a_2 of the deuteron is particularly sensitive to a three-nucleon contact interaction, but experimentally known with only 6% accuracy. It can be deduced from the two experimentally accessible parameters of the nd scattering length. We plan to measure the poorly known "incoherent" nd scattering length a_{i,d} with 10^{-3} accuracy, using a Ramsey apparatus for pseudomagnetic precession with a cold polarised neutron beam at PSI. A polarised target containing both deuterons and protons will permit a measurement relative to the incoherent np scattering length, which is know experimentally with an accuracy of 2.4\times 10^{-4}.
△ Less
Submitted 23 January, 2004;
originally announced January 2004.
-
Is the Unitarity of the quark-mixing-CKM-matrix violated in neutron $β$-decay?
Authors:
H. Abele,
M. Astruc Hoffmann,
S. Baessler,
D. Dubbers,
F. Glück,
U. Müller,
V. Nesvizhevsky,
J. Reich,
O. Zimmer
Abstract:
We report on a new measurement of neutron $β$-decay asymmetry. From the result \linebreak $A_0$ = -0.1189(7), we derive the ratio of the axial vector to the vector coupling constant $λ$ = ${\it g_A/g_V}$ = -1.2739(19). When included in the world average for the neutron lifetime $τ$ = 885.7(7)s, this gives the first element of the Cabibbo-Kobayashi-Maskawa (CKM) matrix $V_{ud} $. With this value…
▽ More
We report on a new measurement of neutron $β$-decay asymmetry. From the result \linebreak $A_0$ = -0.1189(7), we derive the ratio of the axial vector to the vector coupling constant $λ$ = ${\it g_A/g_V}$ = -1.2739(19). When included in the world average for the neutron lifetime $τ$ = 885.7(7)s, this gives the first element of the Cabibbo-Kobayashi-Maskawa (CKM) matrix $V_{ud} $. With this value and the Particle Data Group values for $V_{us}$ and $V_{ub}$, we find a deviation from the unitarity condition for the first row of the CKM matrix of $Δ$ = 0.0083(28), which is 3.0 times the stated error.
△ Less
Submitted 23 June, 2002;
originally announced June 2002.