Creation of super-high-flux photo-neutrons and gamma-rays > 8 MeV using a petawatt laser to irradiate high-Z solid targets
Authors:
E. Liang,
W. Lo,
B. Cage,
E. Fang,
S. Arora,
K. Q. Zheng,
H . Quvedo,
S. A. Bruce,
M. Spinks,
E. Medina,
A. Helal,
T. Ditmire
Abstract:
We report the creation of super-high-flux gamma-rays with energy >8 MeV and photo-neutrons via the (g,n) reaction near giant dipole resonance energies (8 - 20 MeV), using the ~130 J Texas Petawatt laser to irradiate high-Z (Au, Pt, Re, W) targets of mm - cm thickness, at laser intensities up to ~5x1021W/cm2. We detected up to ~ several x 1012 gamma-rays > 8 MeV (~3% of incident laser energy) and ~…
▽ More
We report the creation of super-high-flux gamma-rays with energy >8 MeV and photo-neutrons via the (g,n) reaction near giant dipole resonance energies (8 - 20 MeV), using the ~130 J Texas Petawatt laser to irradiate high-Z (Au, Pt, Re, W) targets of mm - cm thickness, at laser intensities up to ~5x1021W/cm2. We detected up to ~ several x 1012 gamma-rays > 8 MeV (~3% of incident laser energy) and ~ 1010 photo-neutrons per shot. Due to the short pulse and narrow gamma-ray cone (~17o half-width) around laser forward, the peak emergent gamma-ray flux >8 MeV reached ~1027 gammas/cm2/sec, and the peak emergent neutron flux reached ~1020 neutrons/cm2/sec. Such intense gamma-ray and neutron fluxes are among the highest achieved for short-pulse laser experiments. They will facilitate the study of nuclear reactions requiring super-high-flux of gamma-rays or neutrons, such as the creation of r-process elements. These results may also have far-reaching applications for nuclear energy, such as the transmutation of nuclear waste.
△ Less
Submitted 15 February, 2023; v1 submitted 13 February, 2023;
originally announced February 2023.
A Scintillator Attenuation Spectrometer For Intense Gamma-Rays
Authors:
Edison Liang,
Kevin Qinyuan Zheng,
Kelly Yao,
Willie Lo,
Hannah Hasson,
Aileen Zhang,
Matthew Burns,
Wai-Hoi Wong,
Yuxuan Zhang,
Andriy Dashko,
Hernan Quevedo,
Todd Ditmire,
Gillis Dyer
Abstract:
A new type of compact high resolution high sensitivity gamma ray spectrometer for short pulse intense 250 keV to 50 MeV gamma rays has been developed by combining the principles of scintillators and attenuation spectrometers. The first prototype of this scintillator attenuation spectrometer or SAS was tested successfully in Trident laser experiments at LANL. Later versions have been used extensive…
▽ More
A new type of compact high resolution high sensitivity gamma ray spectrometer for short pulse intense 250 keV to 50 MeV gamma rays has been developed by combining the principles of scintillators and attenuation spectrometers. The first prototype of this scintillator attenuation spectrometer or SAS was tested successfully in Trident laser experiments at LANL. Later versions have been used extensively in the Texas Petawatt laser experiments in Austin TX, and more recently in OMEGAEP laser experiments at LLE, Rochester, NY. The SAS is particularly useful for high repetition rate laser applications. Here we give a concise description of the design principles, capabilities and sample preliminary results of the SAS.
△ Less
Submitted 12 May, 2022; v1 submitted 17 April, 2019;
originally announced April 2019.