Real-time antiproton annihilation vertexing with sub-micron resolution
Authors:
M. Berghold,
D. Orsucci,
F. Guatieri,
S. Alfaro,
M. Auzins,
B. Bergmann,
P. Burian,
R. S. Brusa,
A. Camper,
R. Caravita,
F. Castelli,
G. Cerchiari,
R. Ciuryło,
A. Chehaimi,
G. Consolati,
M. Doser,
K. Eliaszuk,
R. Ferguson,
M. Germann,
A. Giszczak,
L. T. Glöggler,
Ł. Graczykowski,
M. Grosbart,
F. Guatieri,
N. Gusakova
, et al. (42 additional authors not shown)
Abstract:
The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric…
▽ More
The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations with an accuracy of $0.62^{+0.40}_{-0.22}μm$, which represents a 35-fold improvement over the previous state-of-the-art for real-time antiproton vertexing. Importantly, these antiproton detection methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables the in-situ calibration of the moiré deflectometer, significantly reducing systematic errors. This sensor emerges as a breakthrough technology for achieving the \aegis scientific goals and has been selected as the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
△ Less
Submitted 23 June, 2024;
originally announced June 2024.
-
CIRCUS: an autonomous control system for antimatter, atomic and quantum physics experiments
Authors:
Marco Volponi,
Saiva Huck,
Ruggero Caravita,
Jakub Zielinski,
Georgy Kornakov,
Grzegorz Kasprowicz,
Dorota Nowicka,
Tassilo Rauschendorfer,
Benjamin Rienäcker,
Francesco Prelz,
Marcis Auzins,
Benedikt Bergmann,
Petr Burian,
Roberto Sennen Brusa,
Antoine Camper,
Fabrizio Castelli,
Roman Ciuryło,
Giovanni Consolati,
Michael Doser,
Lisa Glöggler,
Łukasz Graczykowski,
Malgorzata Grosbart,
Francesco Guatieri,
Nataly Gusakova,
Fredrik Gustafsson
, et al. (27 additional authors not shown)
Abstract:
A powerful and robust control system is a crucial, often neglected, pillar of any modern, complex physics experiment that requires the management of a multitude of different devices and their precise time synchronisation. The AEgIS collaboration presents CIRCUS, a novel, autonomous control system optimised for time-critical experiments such as those at CERN's Antiproton Decelerator and, more broad…
▽ More
A powerful and robust control system is a crucial, often neglected, pillar of any modern, complex physics experiment that requires the management of a multitude of different devices and their precise time synchronisation. The AEgIS collaboration presents CIRCUS, a novel, autonomous control system optimised for time-critical experiments such as those at CERN's Antiproton Decelerator and, more broadly, in atomic and quantum physics research. Its setup is based on Sinara/ARTIQ and TALOS, integrating the ALPACA analysis pipeline, the last two developed entirely in AEgIS. It is suitable for strict synchronicity requirements and repeatable, automated operation of experiments, culminating in autonomous parameter optimisation via feedback from real-time data analysis. CIRCUS has been successfully deployed and tested in AEgIS; being experiment-agnostic and released open-source, other experiments can leverage its capabilities.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
-
Positronium laser cooling via the $1^3S$-$2^3P$ transition with a broadband laser pulse
Authors:
L. T. Glöggler,
N. Gusakova,
B. Rienäcker,
A. Camper,
R. Caravita,
S. Huck,
M. Volponi,
T. Wolz,
L. Penasa,
V. Krumins,
F. Gustafsson,
M. Auzins,
B. Bergmann,
P. Burian,
R. S. Brusa,
F. Castelli,
R. Ciuryło,
D. Comparat,
G. Consolati,
M. Doser,
Ł. Graczykowski,
M. Grosbart,
F. Guatieri,
S. Haider,
M. A. Janik
, et al. (27 additional authors not shown)
Abstract:
We report on laser cooling of a large fraction of positronium (Ps) in free-flight by strongly saturating the $1^3S$-$2^3P$ transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground stat…
▽ More
We report on laser cooling of a large fraction of positronium (Ps) in free-flight by strongly saturating the $1^3S$-$2^3P$ transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived $3^3P$ states. The second effect is the one-dimensional Doppler cooling of Ps, reducing the cloud's temperature from 380(20) K to 170(20) K. We demonstrate a 58(9) % increase in the coldest fraction of the Ps ensemble.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Engineering the sensitivity of macroscopic physical systems to variations in the fine-structure constant
Authors:
Beata Zjawin,
Marcin Bober,
Roman Ciuryło,
Daniel Lisak,
Michał Zawada,
Piotr Wcisło
Abstract:
Experiments aimed at searching for variations in the fine-structure constant $α$ are based on spectroscopy of transitions in microscopic bound systems, such as atoms and ions, or resonances in optical cavities. The sensitivities of these systems to variations in $α$ are typically on the order of unity and are fixed for a given system. For heavy atoms, highly charged ions and nuclear transitions, t…
▽ More
Experiments aimed at searching for variations in the fine-structure constant $α$ are based on spectroscopy of transitions in microscopic bound systems, such as atoms and ions, or resonances in optical cavities. The sensitivities of these systems to variations in $α$ are typically on the order of unity and are fixed for a given system. For heavy atoms, highly charged ions and nuclear transitions, the sensitivity can be increased by benefiting from the relativistic effects and favorable arrangement of quantum states. This article proposes a new method for controlling the sensitivity factor of macroscopic physical systems. Specific concepts of optical cavities with tunable sensitivity to $α$ are described. These systems show qualitatively different properties from those of previous studies of the sensitivity of macroscopic systems to variations in $α$, in which the sensitivity was found to be fixed and fundamentally limited to an order of unity. Although possible experimental constraints attainable with the specific optical cavity arrangements proposed in this article do not yet exceed the present best constraints on $α$ variations, this work paves the way for develo** new approaches to searching for variations in the fundamental constants of physics.
△ Less
Submitted 18 May, 2023;
originally announced May 2023.
-
Optical ultra-stable optical clock cavities as resonant mass gravitational wave detectors in search for new physics
Authors:
M. Narożnik,
M. Bober,
M. Zawada
Abstract:
We propose to use table-top-size ultra-stable optical cavities from the state-of-the-art optical atomic clocks as bar gravitational wave detectors for the frequencies higher than 2 kHz. We show that 2-20 kHz range of gravitational waves' spectrum can be accessed with instruments below 2 meters in size. The proposed cavities' materials and properties are being within the present-day technology gras…
▽ More
We propose to use table-top-size ultra-stable optical cavities from the state-of-the-art optical atomic clocks as bar gravitational wave detectors for the frequencies higher than 2 kHz. We show that 2-20 kHz range of gravitational waves' spectrum can be accessed with instruments below 2 meters in size. The proposed cavities' materials and properties are being within the present-day technology grasp. The ultra-stable optical cavities allow detecting not only predicted gravitational wave signals from such sources as binary neutron star mergers and post-mergers, subsolar-mass primordial black-hole mergers, and collapsing stellar cores, but can reach new physics beyond standard model looking for ultralight bosons such as QCD axions and axion-like particles formed through black hole superradiance.
△ Less
Submitted 19 January, 2023;
originally announced January 2023.
-
Photoionization cross sections of ultracold $^{88}$Sr in $^1$P$_1$ and $^3$S$_1$ states at 390 nm and the resulting blue-detuned magic wavelength optical lattice clock constraints
Authors:
Marcin Witkowski,
Sławomir Bilicki,
Marcin Bober,
Domagoj Kovačić,
Vijay Singh,
Ara Tonoyan,
Michał Zawada
Abstract:
We present the measurements of the photoionisation cross sections of the excited $^1$P$_1$ and $^3$S$_1$ states of ultracold $^{88}$Sr atoms at 389.889 nm wavelength, which is the magic wavelength of the $^{1}$S$_{0}$-${}^{3}$P${}_{0}$ clock transition. The photoionisation cross section of the $^1$P$_1$ state is determined from the measured ionisation rates of $^{88}$Sr in the magneto-optical trap…
▽ More
We present the measurements of the photoionisation cross sections of the excited $^1$P$_1$ and $^3$S$_1$ states of ultracold $^{88}$Sr atoms at 389.889 nm wavelength, which is the magic wavelength of the $^{1}$S$_{0}$-${}^{3}$P${}_{0}$ clock transition. The photoionisation cross section of the $^1$P$_1$ state is determined from the measured ionisation rates of $^{88}$Sr in the magneto-optical trap in the $^1$P$_1$ state to be 2.20(50)$\times$10$^{-20}$ m$^2$, while the photoionisation cross section of $^{88}$Sr in the $^3$S$_1$ state is inferred from the photoionisation-induced reduction in the number of atoms transferred through the $^3\text{S}_1$ state in an operating optical lattice clock to be $1.38(66)\times$10$^{-18}$ m$^2$. Furthermore, the resulting limitations of employing a blue-detuned magic wavelength optical lattice in strontium optical lattice clocks are evaluated. We estimated photoionisation induced loss rates of atoms at 389.889 nm wavelength under typical experimental conditions and made several suggestions on how to mitigate these losses. In particular, the large photoionisation induced losses for the $^3$S$_1$ state would make the use of the $^3$S$_1$ state in the optical cycle in a blue-detuned optical lattice unfeasible and would instead require the less commonly used $^3$D$_{1,2}$ states during the detection part of the optical clock cycle.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
Ultimate stability of active optical frequency standards
Authors:
Georgy A. Kazakov,
Swadheen Dubey,
Anna Bychek,
Uwe Sterr,
Marcin Bober,
Michał Zawada
Abstract:
Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to keep the optical phase during a dead time between interrogations as in passive clocks, but only to boost the active clock's low output power to practically usa…
▽ More
Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to keep the optical phase during a dead time between interrogations as in passive clocks, but only to boost the active clock's low output power to practically usable levels with the current state of technology. Here we investigate the spectral properties and the stability of active clocks, including homogeneous and inhomogeneous broadening effects. We find that for short averaging times the stability is limited by photon shot noise from the limited emitted laser power and at long averaging times by phase diffusion of the laser output. Operational parameters for best long-term stability were identified. Using realistic numbers for an active clock with $^{87}$Sr we find that an optimized stability of $σ_y(τ) \approx 4\times10^{-18}/\sqrt{τ[\mathrm{s}]}$ is achievable.
△ Less
Submitted 26 October, 2022; v1 submitted 27 May, 2022;
originally announced May 2022.
-
Guidelines for develo** optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups develo** optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trap**, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Photoionization cross sections of the 5S${}_{1/2}$ and 5P${}_{3/2}$ states of Rb in simultaneous magneto-optical trap** of Rb and Hg
Authors:
M. Witkowski,
R. Munoz-Rodriguez,
A. Raczyński,
J. Zaremba,
B. Nagórny,
P. S. Żuchowski,
R. Ciuryło,
M. Zawada
Abstract:
We report the measurement of the photoionization cross sections of the 5S${}_{1/2}$ and 5P${}_{3/2}$ states of ${}^{87}$Rb in a two-species Hg and Rb magneto-optical trap (MOT) by the cooling laser for Hg. The photoionization cross sections of Rb in the 5S${}_{1/2}$ and 5P${}_{3/2}$ states at 253.7~nm are determined to be $1^{+4.3}_{-1}\times10^{-20}~\text{cm}^2$ and…
▽ More
We report the measurement of the photoionization cross sections of the 5S${}_{1/2}$ and 5P${}_{3/2}$ states of ${}^{87}$Rb in a two-species Hg and Rb magneto-optical trap (MOT) by the cooling laser for Hg. The photoionization cross sections of Rb in the 5S${}_{1/2}$ and 5P${}_{3/2}$ states at 253.7~nm are determined to be $1^{+4.3}_{-1}\times10^{-20}~\text{cm}^2$ and $4.63(30)\times 10^{-18}\text{cm}^2$, respectively. To measure the 5S${}_{1/2}$ and 5P${}_{3/2}$ states fractions in the MOT we detected photoionization rate of the 5P${}_{3/2}$ state by an additional 401.5~nm laser. The photoionization cross section of Rb in the 5P${}_{3/2}$ state at 401.5~nm is determined to be $\text{1.18(10)}\times10^{-17}~\text{cm}^2$.
△ Less
Submitted 29 October, 2018;
originally announced October 2018.
-
First observation with global network of optical atomic clocks aimed for a dark matter detection
Authors:
P. Wcisło,
P. Ablewski,
K. Beloy,
S. Bilicki,
M. Bober,
R. Brown,
R. Fasano,
R. Ciuryło,
H. Hachisu,
T. Ido,
J. Lodewyck,
A. Ludlow,
W. McGrew,
P. Morzyński,
D. Nicolodi,
M. Schioppo,
M. Sekido,
R. Le Targat,
P. Wolf,
X. Zhang,
B. Zjawin,
M. Zawada
Abstract:
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comp…
▽ More
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comparisons of the clocks. We report a two orders of magnitude improvement in constraints on transient variations of the fine-structure constant, which considerably improves the detection limit for the standard model (SM) - DM coupling. We use Yb and Sr optical atomic clocks at four laboratories on three continents to search for both topological defect (TD) and massive scalar field candidates. No signal consistent with a dark-matter coupling is identified, leading to significantly improved constraints on the DM-SM couplings.
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Fibre-optic delivery of time and frequency to VLBI station
Authors:
P. Krehlik,
Ł. Buczek,
J. Kołodziej,
M. Lipiński,
Ł. Śliwczyński,
J. Nawrocki,
P. Nogaś,
A. Marecki,
E. Pazderski,
P. Ablewski,
M. Bober,
R. Ciuryło,
A. Cygan,
D. Lisak,
P. Masłowski,
P. Morzyński,
M. Zawada,
R. M. Campbell,
J. Pieczerak,
A. Binczewski,
K. Turza
Abstract:
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabi…
▽ More
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekee** laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.
△ Less
Submitted 7 July, 2017; v1 submitted 28 March, 2017;
originally announced March 2017.
-
Dual Hg-Rb magneto-optical trap
Authors:
Marcin Witkowski,
Bartlomiej Nagoorny,
Rodolfo Munoz-Rodriguez,
Roman Ciurylo,
Piotr Szymon Zuchowski,
Slawomir Bilicki,
Marcin Piotrowski,
Piotr Morzynski,
Michal Zawada
Abstract:
We present a two-species laser cooling apparatus capable of simultaneously collecting Rb and Hg atomic gases into a magneto-optical trap (MOT). The atomic sources, laser system, and vacuum set-up are described. While there is a loss of Rb atoms in the MOT due to photoionization by the Hg cooling laser, we show that it does not prevent simultaneous trap** of Rb and Hg. We also demonstrate intersp…
▽ More
We present a two-species laser cooling apparatus capable of simultaneously collecting Rb and Hg atomic gases into a magneto-optical trap (MOT). The atomic sources, laser system, and vacuum set-up are described. While there is a loss of Rb atoms in the MOT due to photoionization by the Hg cooling laser, we show that it does not prevent simultaneous trap** of Rb and Hg. We also demonstrate interspecies collision-induced losses in the ${}^{87}$Rb-${}^{202}$Hg system.
△ Less
Submitted 14 February, 2017;
originally announced February 2017.
-
A Jamming-Resilient MAC-layer Device Identification for Internet of Things
Authors:
Przemysław Błaśkiewicz,
Jacek Cichoń,
Jakub Lemiesz,
Mirosław Kutyłowski,
Marcin Zawada,
Krystyna Napierała,
Michał Panek,
Stanisław Strzyż
Abstract:
In a number of practical scenarios a wireless device needs to mark its presence, for instance, to some access point. That enables the access point to assign the device its transmission slot or update the count of the network nodes. Many protocols can achieve exactly this result. In this paper, our goal is to show how that can be done in the simplest messaging model, the so-called bee** model. Co…
▽ More
In a number of practical scenarios a wireless device needs to mark its presence, for instance, to some access point. That enables the access point to assign the device its transmission slot or update the count of the network nodes. Many protocols can achieve exactly this result. In this paper, our goal is to show how that can be done in the simplest messaging model, the so-called bee** model. Consequently, we constrain our design so that the station does not send any modulated information in the signal and the receiver actually does not need to demodulate/decode it. We are interested in sending just a short signal, so called 'beep'. Moreover, we want to design such protocol that is resilient to random interference and enables us to identify devices which are sending the signal, as opposed to only note their presence. To do that, we leverage temporal correlations of a sequence of beeps issued by a device, as if the time-moments when they happen come from a pre-defined probability distribution, that is the fingerpring of the device.
△ Less
Submitted 4 July, 2016;
originally announced July 2016.
-
One- and Multi-Pass Long-Hop Routing for Wireless Network
Authors:
Przemysław Błaśkiewicz,
Jacek Cichoń,
Jakub Lemiesz,
Mirosław Kutyłowski,
Marcin Zawada
Abstract:
In our paper we provide mathematical analysis of a probabilistic long-hop routing algorithms which uses as the randomizing factor the estimate of distance of a station from the previous-hop source of the message.
In our paper we provide mathematical analysis of a probabilistic long-hop routing algorithms which uses as the randomizing factor the estimate of distance of a station from the previous-hop source of the message.
△ Less
Submitted 4 July, 2016;
originally announced July 2016.
-
$λ$-persistant CSMA: a radio-channel access protocol
Authors:
Przemysław Błaśkiewicz,
Jacek Cichoń,
Jakub Lemiesz,
Mirosław Kutyłowski,
Marcin Zawada,
Szymon Stefański,
Krzysztof Chrobak
Abstract:
This paper presents an algorithm that improves channel-access statistics for wireless medium. The proposed modification of the standard CSMA algorithm is analytically shown to yield better results and simulation results are given to support this claim.
This paper presents an algorithm that improves channel-access statistics for wireless medium. The proposed modification of the standard CSMA algorithm is analytically shown to yield better results and simulation results are given to support this claim.
△ Less
Submitted 4 July, 2016;
originally announced July 2016.
-
Searching for topological defect dark matter with optical atomic clocks
Authors:
Piotr Wcislo,
Piotr Morzynski,
Marcin Bober,
Agata Cygan,
Daniel Lisak,
Roman Ciurylo,
Michal Zawada
Abstract:
The total mass density of the Universe appears to be dominated by dark matter. However, beyond its gravitational interactions at the galactic scale, little is known about its nature. Extensions of the quantum electrodynamics Lagrangian with dark-matter coupling terms may result in changes to Standard Model parameters. Recently, it was proposed that a network of atomic clocks could be used to searc…
▽ More
The total mass density of the Universe appears to be dominated by dark matter. However, beyond its gravitational interactions at the galactic scale, little is known about its nature. Extensions of the quantum electrodynamics Lagrangian with dark-matter coupling terms may result in changes to Standard Model parameters. Recently, it was proposed that a network of atomic clocks could be used to search for transient signals of a hypothetical dark matter in the form of stable topological defects. The clocks become desynchronized when a dark-matter object sweeps through the network. This pioneering approach, which is applicable only for distant clocks, is limited by the quality of the fibre links. Here, we present an alternative experimental approach that is applicable to both closely spaced and distant optical atomic clocks and benefits from their individual susceptibilities to dark matter, hence not requiring fibre links. We explore a new dimension of astrophysical observations by constraining the strength of atomic coupling to the hypothetical dark-matter cosmic objects. Our experimental constraint exceeds the previous limits; in fact, it not only reaches the ultimate level expected to be achievable with a constellation of GPS atomic clocks but also has a large potential for improvement.
△ Less
Submitted 2 September, 2016; v1 submitted 18 May, 2016;
originally announced May 2016.
-
Absolute measurement of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ clock transition in neutral ${}^{88}$Sr over the 330 km-long stabilized fibre optic link
Authors:
Piotr Morzynski,
Marcin Bober,
Dobroslawa Bartoszek-Bober,
Jerzy Nawrocki,
Przemyslaw Krehlik,
Lukasz Sliwczynski,
Marcin Lipinski,
Piotr Maslowski,
Agata Cygan,
Piotr Dunst,
Michal Garus,
Daniel Lisak,
Jerzy Zachorowski,
Wojciech Gawlik,
Czeslaw Radzewicz,
Roman Ciurylo,
Michal Zawada
Abstract:
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fi…
▽ More
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.
-
Polarizabilities of the 87Sr Clock Transition
Authors:
C Shi,
J. -L Robyr,
U Eismann,
M Zawada,
L Lorini,
R Le Targat,
J Lodewyck
Abstract:
In this paper, we propose an in-depth review of the vector and tensor polarizabilities of the two energy levels of the 87Sr clock transition whose measurement was reported in [P. G. Westergaard et al., Phys. Rev. Lett. 106, 210801 (2011)]. We conduct a theoretical calculation that reproduces the measured coefficients. In addition, we detail the experimental conditions used for their measurement in…
▽ More
In this paper, we propose an in-depth review of the vector and tensor polarizabilities of the two energy levels of the 87Sr clock transition whose measurement was reported in [P. G. Westergaard et al., Phys. Rev. Lett. 106, 210801 (2011)]. We conduct a theoretical calculation that reproduces the measured coefficients. In addition, we detail the experimental conditions used for their measurement in two Sr optical lattice clocks, and exhibit the quadratic behaviour of the vector and tensor shifts with the depth of the trap** potential and evaluate their impact on the accuracy of the clock.
△ Less
Submitted 31 March, 2015;
originally announced March 2015.
-
Absolute Frequency Measurement of Rubidium 5S-7S Two-Photon Transitions
Authors:
Piotr Morzynski,
Piotr Wcislo,
Piotr Ablewski,
Rafal Gartman,
Wojciech Gawlik,
Piotr Maslowski,
Bartlomiej Nagorny,
Filip Ozimek,
Czeslaw Radzewicz,
Marcin Witkowski,
Roman Ciurylo,
Michal Zawada
Abstract:
We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm) insensitive to first order in a magnetic field, is a promising candidate for frequency reference. The performed tests yield the transition frequency with accurac…
▽ More
We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm) insensitive to first order in a magnetic field, is a promising candidate for frequency reference. The performed tests yield the transition frequency with accuracy better than reported previously.
△ Less
Submitted 14 November, 2013;
originally announced November 2013.
-
Matter-Wave Interference versus Spontaneous Pattern Formation in Spinor Bose-Einstein Condensate
Authors:
Marcin Witkowski,
Rafal Gartman,
Bartlomiej Nagorny,
Marcin Piotrowski,
Marcin Plodzien,
Krzysztof Sacha,
Jacek Szczepkowski,
Jerzy Zachorowski,
Michal Zawada,
Wojciech Gawlik
Abstract:
We describe effects of matter-wave interference of spinor states in the $^{87}$Rb Bose-Einstein condensate. The components of the F=2 manifold are populated by forced Majorana transitions and then fall freely due to gravity in an applied magnetic field. Weak inhomogeneities of the magnetic field, present in the experiment, impose relative velocities onto different $m_F$ components, which show up a…
▽ More
We describe effects of matter-wave interference of spinor states in the $^{87}$Rb Bose-Einstein condensate. The components of the F=2 manifold are populated by forced Majorana transitions and then fall freely due to gravity in an applied magnetic field. Weak inhomogeneities of the magnetic field, present in the experiment, impose relative velocities onto different $m_F$ components, which show up as interference patterns upon measurement of atomic density distributions with a Stern-Gerlach imaging method. We show that interference effects may appear in experiments even if gradients of the magnetic field components are eliminated but higher order inhomogeneity is present and the duration of the interaction is long enough. In particular, we show that the resulting matter-wave interference patterns can mimic spontaneous pattern formation in the quantum gas.
△ Less
Submitted 25 August, 2013; v1 submitted 19 March, 2013;
originally announced March 2013.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Observation and cancellation of the dc Stark shift in strontium optical lattice clocks
Authors:
Jérôme Lodewyck,
Michal Zawada,
Luca Lorini,
Mikhail Gurov,
Pierre Lemonde
Abstract:
We report on the observation of a dc Stark frequency shift at the $10^{-13}$ level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residua…
▽ More
We report on the observation of a dc Stark frequency shift at the $10^{-13}$ level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residual dc Stark frequency shift on the clock transition at the $10^{-18}$ level by applying an external electric field. This study shows that the dc Stark shift can play an important role in the accuracy budget of lattice clocks, and should be duly taken into account.
△ Less
Submitted 22 August, 2011;
originally announced August 2011.
-
Lattice Induced Frequency Shifts in Sr Optical Lattice Clocks at the $10^{-17}$ Level
Authors:
Philip G. Westergaard,
Jérôme Lodewyck,
Luca Lorini,
Arnaud Lecallier,
Eric Burt,
Michal Zawada,
Jacques Millo,
Pierre Lemonde
Abstract:
We present a comprehensive study of the frequency shifts associated with the lattice potential for a Sr lattice clock. By comparing two such clocks with a frequency stability reaching $5\times 10^{-17}$ after a one hour integration time, and varying the lattice depth up to $U_0=900 \, E_r$ with $E_r$ being the recoil energy, we evaluate lattice related shifts with an unprecedented accuracy. We put…
▽ More
We present a comprehensive study of the frequency shifts associated with the lattice potential for a Sr lattice clock. By comparing two such clocks with a frequency stability reaching $5\times 10^{-17}$ after a one hour integration time, and varying the lattice depth up to $U_0=900 \, E_r$ with $E_r$ being the recoil energy, we evaluate lattice related shifts with an unprecedented accuracy. We put the first experimental upper bound on the recently predicted frequency shift due to the magnetic dipole (M1) and electric quadrupole (E2) interactions. This upper bound is significantly smaller than the theoretical upper limit. We also give a new upper limit on the effect of hyperpolarizability with an improvement by more than one order of magnitude. Finally, we report the first observation of the vector and tensor shifts in a lattice clock. Combining these measurements, we show that all known lattice related perturbation will not affect the clock accuracy down to the $10^{-17}$ level, even for very deep lattices, up to $U_0=150\,E_r$.
△ Less
Submitted 9 February, 2011;
originally announced February 2011.
-
Analysis and calibration of absorptive images of Bose-Einstein condensate at non-zero temperatures
Authors:
J. Szczepkowski,
R. Gartman,
M. Witkowski,
L. Tracewski,
M. Zawada,
W. Gawlik
Abstract:
We describe the method allowing quantitative interpretation of absorptive images of mixtures of BEC and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different m…
▽ More
We describe the method allowing quantitative interpretation of absorptive images of mixtures of BEC and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.
△ Less
Submitted 25 November, 2008;
originally announced November 2008.
-
Free-fall expansion of finite-temperature Bose-Einstein condensed gas in the non Thomas-Fermi regime
Authors:
M. Zawada,
R. Abdoul,
J. Chwedeńczuk,
R. Gartman,
J. Szczepkowski,
L. Tracewski,
M. Witkowski,
W. Gawlik
Abstract:
We report on our study of the free-fall expansion of a finite-temperature Bose-Einstein condensed cloud of 87Rb. The experiments are performed with a variable total number of atoms while kee** constant the number of atoms in the condensate. The results provide evidence that the BEC dynamics depends on the interaction with thermal fraction. In particular, they provide experimental evidence that…
▽ More
We report on our study of the free-fall expansion of a finite-temperature Bose-Einstein condensed cloud of 87Rb. The experiments are performed with a variable total number of atoms while kee** constant the number of atoms in the condensate. The results provide evidence that the BEC dynamics depends on the interaction with thermal fraction. In particular, they provide experimental evidence that thermal cloud compresses the condensate.
△ Less
Submitted 11 November, 2008;
originally announced November 2008.
-
Optimal geometry for efficient loading of an optical dipole trap
Authors:
Andrzej Szczepkowicz,
Leszek Krzemien,
Adam Wojciechowski,
Krzysztof Brzozowski,
Michael Kruger,
Michal Zawada,
Marcin Witkowski,
Jerzy Zachorowski,
Wojciech Gawlik
Abstract:
One important factor which determines efficiency of loading cold atoms into an optical dipole trap from a magneto-optical trap is the distance between the trap centers. By studying this efficiency for various optical trap depths (2--110 mK) we find that for optimum dipole trap loading, longitudinal displacements up to 15 mm are necessary. An explanation for this observation is presented and comp…
▽ More
One important factor which determines efficiency of loading cold atoms into an optical dipole trap from a magneto-optical trap is the distance between the trap centers. By studying this efficiency for various optical trap depths (2--110 mK) we find that for optimum dipole trap loading, longitudinal displacements up to 15 mm are necessary. An explanation for this observation is presented and compared with other work and a simple analytical formula is derived for the optimum distance between the trap centers.
△ Less
Submitted 31 December, 2008; v1 submitted 11 September, 2008;
originally announced September 2008.
-
Probe spectroscopy in an operating magneto-optical trap: the role of Raman transitions between discrete and continuum atomic states
Authors:
Tomasz M. Brzozowski,
Maria Brzozowska,
Jerzy Zachorowski,
Michał Zawada,
Wojciech Gawlik
Abstract:
We report on cw measurements of probe beam absorption and four-wave-mixing spectra in a $^{85}$Rb magneto-optical trap taken while the trap is in operation. The trap** beams are used as pump light. We concentrate on the central feature of the spectra at small pump-probe detuning and attribute its narrow resonant structures to the superposition of Raman transitions between light-shifted subleve…
▽ More
We report on cw measurements of probe beam absorption and four-wave-mixing spectra in a $^{85}$Rb magneto-optical trap taken while the trap is in operation. The trap** beams are used as pump light. We concentrate on the central feature of the spectra at small pump-probe detuning and attribute its narrow resonant structures to the superposition of Raman transitions between light-shifted sublevels of the ground atomic state and to atomic recoil processes. These two contributions have different dependencies on trap parameters and we show that the former is inhomogeneously broadened. The strong dependence of the spectra on the probe-beam polarization indicates the existence of large optical anisotropy of the cold-atom sample, which is attributed to the recoil effects. We point out that the recoil-induced resonances can be isolated from other contributions, making pump-probe spectroscopy a highly sensitive diagnostic tool for atoms in a working MOT.
△ Less
Submitted 20 October, 2004; v1 submitted 1 September, 2004;
originally announced September 2004.
-
Optically-induced lensing effect on a Bose-Einstein condensate expanding in a moving lattice
Authors:
L. Fallani,
F. S. Cataliotti,
J. Catani,
C. Fort,
M. Modugno,
M. Zawada,
M. Inguscio
Abstract:
We report the experimental observation of a lensing effect on a Bose-Einstein condensate expanding in a moving 1D optical lattice. The effect of the periodic potential can be described by an effective mass dependent on the condensate quasi-momentum. By changing the velocity of the atoms in the frame of the optical lattice we induce a focusing of the condensate along the lattice direction. The ex…
▽ More
We report the experimental observation of a lensing effect on a Bose-Einstein condensate expanding in a moving 1D optical lattice. The effect of the periodic potential can be described by an effective mass dependent on the condensate quasi-momentum. By changing the velocity of the atoms in the frame of the optical lattice we induce a focusing of the condensate along the lattice direction. The experimental results are compared with the numerical predictions of an effective 1D theoretical model. Besides, a precise band spectroscopy of the system is carried out by looking at the real-space propagation of the atomic wavepacket in the optical lattice.
△ Less
Submitted 21 January, 2004; v1 submitted 31 March, 2003;