-
Mass measurements beyond the major r-process waiting point 80Zn
Authors:
S. Baruah,
G. Audi,
K. Blaum,
M. Dworschak,
S. George,
C. Guenaut,
U. Hager,
F. Herfurth,
A. Herlert,
A. Kellerbauer,
H. -J. Kluge,
D. Lunney,
H. Schatz,
L. Schweikhard,
C. Yazidjian
Abstract:
High-precision mass measurements on neutron-rich zinc isotopes 71m,72-81Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of 81Zn has been experimentally determined. This makes 80Zn the first of the few major waiting points along the path of the astrophysical rapid neutron capture process where neutron separation energy and neutron capture Q-val…
▽ More
High-precision mass measurements on neutron-rich zinc isotopes 71m,72-81Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of 81Zn has been experimentally determined. This makes 80Zn the first of the few major waiting points along the path of the astrophysical rapid neutron capture process where neutron separation energy and neutron capture Q-value are determined experimentally. As a consequence, the astrophysical conditions required for this waiting point and its associated abundance signatures to occur in r-process models can now be mapped precisely. The measurements also confirm the robustness of the N = 50 shell closure for Z = 30 farther from stability.
△ Less
Submitted 14 November, 2008;
originally announced November 2008.
-
Electric and magnetic field optimization procedure for Penning trap mass spectrometers
Authors:
D. Beck,
K. Blaum,
G. Bollen,
P. Delahaye,
S. George,
C. Guenaut,
F. Herfurth,
A. Herlert,
D. Lunney,
L. Schweikhard,
C. Yazidjian
Abstract:
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency a…
▽ More
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.
△ Less
Submitted 29 May, 2008;
originally announced May 2008.
-
Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides
Authors:
S. George,
G. Audi,
B. Blank,
K. Blaum,
M. Breitenfeldt,
U. Hager,
F. Herfurth,
A. Herlert,
A. Kellerbauer,
H. -J. Kluge,
M. Kretzschmar,
D. Lunney,
R. Savreux,
S. Schwarz,
L. Schweikhard,
C. Yazidjian
Abstract:
High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single…
▽ More
High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitter 26Al m confirm previous measurements and corresponding theoretical corrections of the ft-values.
△ Less
Submitted 17 January, 2008;
originally announced January 2008.
-
Evidence for a breakdown of the Isobaric Multiplet Mass Equation: A study of the A=35, T=3/2 isospin quartet
Authors:
C. Yazidjian,
G. Audi,
D. Beck,
K. Blaum,
S. George,
C. Guenaut,
F. Herfurth,
A. Herlert,
A. Kellerbauer,
H. -J. Kluge,
D. Lunney,
L. Schweikhard
Abstract:
Mass measurements on radionuclides along the potassium isotope chain have been performed with the ISOLTRAP Penning trap mass spectrometer. For 35K T1/2=178ms) to 46K (T1/2=105s) relative mass uncertainties of 2x10-8 and better have been achieved. The accurate mass determination of 35K (dm=0.54keV) has been exploited to test the Isobaric Multiplet Mass Equation (IMME) for the A=35, T=3/2 isospinq…
▽ More
Mass measurements on radionuclides along the potassium isotope chain have been performed with the ISOLTRAP Penning trap mass spectrometer. For 35K T1/2=178ms) to 46K (T1/2=105s) relative mass uncertainties of 2x10-8 and better have been achieved. The accurate mass determination of 35K (dm=0.54keV) has been exploited to test the Isobaric Multiplet Mass Equation (IMME) for the A=35, T=3/2 isospinquartet. The experimental results indicate a deviation from the generally adopted quadratic form.
△ Less
Submitted 21 July, 2007;
originally announced July 2007.
-
The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results
Authors:
S. George,
K. Blaum,
F. Herfurth,
A. Herlert,
M. Kretzschmar,
S. Nagy,
S. Schwarz,
L. Schweikhard,
C. Yazidjian
Abstract:
The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has b…
▽ More
The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for different excitation times, pulse structures, and detunings of the quadrupole field has been carried out in a quantum mechanical framework and is discussed in detail in the preceding article in this journal by M. Kretzschmar. Here, the new excitation technique has been applied with the ISOLTRAP mass spectrometer at ISOLDE/CERN for mass measurements on stable as well as short-lived nuclides. The experimental resonances are in agreement with the theoretical predictions and a precision gain close to a factor of four was achieved compared to the use of the conventional excitation technique.
△ Less
Submitted 22 January, 2007;
originally announced January 2007.
-
Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides
Authors:
M. Marie-Jeanne,
J. Alonso,
K. Blaum,
S. Djekic,
M. Dworschak,
U. Hager,
A. Herlert,
Sz. Nagy,
R. Savreux,
L. Schweikhard,
S. Stahl,
C. Yazidjian
Abstract:
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pre…
▽ More
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK and dp=+/-50mtorr has been achieved, which corresponds to a relative frequency change of 2.7x10^{-9} and 1.5x10^{-10}, respectively. With this stabilization the frequency determination with the Penning trap only shows a linear temporal drift over several hours on the 10 ppb level due to the finite resistance of the superconducting magnet coils.
△ Less
Submitted 19 January, 2007;
originally announced January 2007.
-
High-precision mass measurements of nickel, copper, and gallium isotopes and the purported shell closure at N=40
Authors:
C. Guenaut,
G. Audi,
D. Beck,
K. Blaum,
G. Bollen,
P. Delahaye,
F. Herfurth,
A. Kellerbauer,
H. -J. Kluge,
J. Libert,
D. Lunney,
S. Schwarz,
L. Schweikhard,
C. Yazidjian
Abstract:
High-precision mass measurements of more than thirty neutron-rich nuclides around the Z=28 closed proton shell were performed with the triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN to address the question of a possible neutron shell closure at N=40. The results, for 57,60,64-69Ni (Z=28), 65-74,76Cu (Z=29), and 63-65,68-78Ga (Z=31), have a relative uncertainty of the order of 10^8. In par…
▽ More
High-precision mass measurements of more than thirty neutron-rich nuclides around the Z=28 closed proton shell were performed with the triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN to address the question of a possible neutron shell closure at N=40. The results, for 57,60,64-69Ni (Z=28), 65-74,76Cu (Z=29), and 63-65,68-78Ga (Z=31), have a relative uncertainty of the order of 10^8. In particular, the masses of 72-74,76Cu have been measured for the first time. We analyse the resulting mass surface for signs of magicity, comparing the behavior of N=40 to that of known magic numbers and to mid-shell behavior. Contrary to nuclear spectroscopy studies, no indications of a shell or sub-shell closure are found for N=40.
△ Less
Submitted 22 January, 2007;
originally announced January 2007.
-
Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry
Authors:
S. George,
S. Baruah,
B. Blank,
K. Blaum,
M. Breitenfeldt,
U. Hager,
F. Herfurth,
A. Herlert,
A. Kellerbauer,
H. J. Kluge,
M. Kretzschmar,
D. Lunney,
R. Savreux,
S. Schwarz,
L. Schweikhard,
C. Yazidjian
Abstract:
Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an…
▽ More
Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an uncertainty of $1.6\cdot 10^{-8}$ using the ISOLTRAP Penning trap mass spectrometer at CERN. The mass value of the superallowed beta-emitter $^{38}$Ca is an important contribution for testing the conserved-vector-current hypothesis of the electroweak interaction. It is shown that the Ramsey method applied to mass measurements yields a statistical uncertainty similar to that obtained by the conventional technique ten times faster.
△ Less
Submitted 19 January, 2007;
originally announced January 2007.