-
Measurement Accuracy in Silicon Photonic Ring Resonator Thermometers: Identifying and Mitigating Intrinsic Impairments
Authors:
Siegfried Janz,
Sergey Dedyulin,
D. -X. Xu,
Martin Vachon,
Shurui Wang,
Ross Cheriton,
John Weber
Abstract:
Silicon photonic ring resonator thermometers have been shown to provide temperature measurements with a 10 mK accuracy. In this work we identify and quantify the intrinsic on-chip impairments that may limit further improvement in temperature measurement accuracy. The impairments arise from optically induced changes in the waveguide effective index, and from back-reflections and scattering at defec…
▽ More
Silicon photonic ring resonator thermometers have been shown to provide temperature measurements with a 10 mK accuracy. In this work we identify and quantify the intrinsic on-chip impairments that may limit further improvement in temperature measurement accuracy. The impairments arise from optically induced changes in the waveguide effective index, and from back-reflections and scattering at defects and interfaces inside the ring cavity and along the path between light source and detector. These impairments are characterized for 220 x 500 nm Si waveguide rings by experimental measurement in a calibrated temperature bath and by phenomenological models of ring response. At different optical power levels both positive and negative light induced resonance shifts are observed. For a ring with L = 100 um cavity length, the self-heating induced resonance red shift can alter the temperature reading by 200 mK at 1 mW incident power, while a small blue shift is observed below 100 uW. The effect of self-heating is shown to be effectively suppressed by choosing longer ring cavities. Scattering and back-reflections often produce split and distorted resonance line shapes. Although these distortions can vary with resonance order, they are almost completely invariant with temperature for a given resonance and do not lead to measurement errors in themselves. The effect of line shape distortions can largely be mitigated by tracking only selected resonance orders with negligible shape distortion, and by measuring the resonance minimum wavelength directly, rather than attempting to fit the entire resonance line shape. The results demonstrate the temperature error due to these impairments can be limited to below the 3 mK level through appropriate design choices and measurement procedures.
△ Less
Submitted 27 June, 2023;
originally announced June 2023.
-
Ultra-low power nonlinear optics in a high Q CMOS compatible integrated micro-ring resonator
Authors:
M. Ferrera,
D. Duchesne,
L. Razzari,
M. Peccianti,
R. Morandotti,
P. Cheben,
S. Janz,
D. -X. Xu,
B. E. Little,
S. Chu,
D. J. Moss
Abstract:
We demonstrate efficient, low power, continuous-wave four-wave mixing in the C-band, using a high index doped silica glass micro ring resonator having a Q-factor of 1.2 million. A record high conversion efficiency for this kind of device is achieved over a bandwidth of 20nm. We show theoretically that the characteristic low dispersion enables phase-matching over a bandwidth > 160nm.
We demonstrate efficient, low power, continuous-wave four-wave mixing in the C-band, using a high index doped silica glass micro ring resonator having a Q-factor of 1.2 million. A record high conversion efficiency for this kind of device is achieved over a bandwidth of 20nm. We show theoretically that the characteristic low dispersion enables phase-matching over a bandwidth > 160nm.
△ Less
Submitted 12 November, 2017;
originally announced November 2017.
-
Optically bright Active Galactic Nuclei in the ROSAT-Faint Source Catalogue
Authors:
M. -P. Veron-Cetty,
S. K. Balayan,
A. M. Mickaelian,
R. Mujica,
V. Chavushyan,
S. A. Hakopian,
D. Engels,
P. Veron,
F. -J. Zickgraf,
W. Voges,
D. -W. Xu
Abstract:
To build a large, optically bright, X-ray selected AGN sample we have correlated the ROSAT-FSC catalogue of X-ray sources with the USNO catalogue limited to objects brighter than O=16.5 and then with the APS database. Each of the 3,212 coincidences was classified using the slitless Hamburg spectra. 493 objects were found to be extended and 2,719 starlike. Using both the extended objects and the…
▽ More
To build a large, optically bright, X-ray selected AGN sample we have correlated the ROSAT-FSC catalogue of X-ray sources with the USNO catalogue limited to objects brighter than O=16.5 and then with the APS database. Each of the 3,212 coincidences was classified using the slitless Hamburg spectra. 493 objects were found to be extended and 2,719 starlike. Using both the extended objects and the galaxies known from published catalogues we built up a sample of 185 galaxies with O_APS < 17.0 mag, which are high-probability counterparts of RASS-FSC X-ray sources. 130 galaxies have a redshift from the literature and for another 34 we obtained new spectra. The fraction of Seyfert galaxies in this sample is 20 %. To select a corresponding sample of 144 high-probability counterparts among the starlike sources we searched for very blue objects in an APS-based color-magnitude diagram. Forty-one were already known AGN and for another 91 objects we obtained new spectra, yielding 42 new AGN, increasing their number in the sample to 83. This confirms that surveys of bright QSOs are still significantly incomplete. On the other hand we find that, at a flux limit of 0.02 count /-1 and at this magnitude, only 40 % of all QSOs are detected by ROSAT.
△ Less
Submitted 4 December, 2003;
originally announced December 2003.