Application of isochronous mass spectrometry for the study of angular momentum population in projectile fragmentation reactions
Authors:
X. L. Tu,
A. Kelic-Heil,
Yu. A. Litvinov,
Zs. Podolyak,
Y. H. Zhang,
W. J. Huang,
H. S. Xu,
K. Blaum,
F. Bosch,
R. J. Chen,
X. C. Chen,
C. Y. Fu,
B. S. Gao,
Z. Ge,
Z. G. Hu,
D. W. Liu,
S. A. Litvinov,
X. W. Ma,
R. S. Mao,
B. Mei,
P. Shuai,
B. H. Sun,
Y. Sun,
Z. Y. Sun,
P. M. Walker
, et al. (15 additional authors not shown)
Abstract:
Isochronous mass spectrometry was applied to measure isomeric yield ratios of fragmentation reaction products. This approach is complementary to conventional gamma-ray spectroscopy in particular for measuring yield ratios for long-lived isomeric states. Isomeric yield ratios for the high-spin I = 19/2 states in the mirror nuclei 53Fe and 53Co are measured to study angular momentum population follo…
▽ More
Isochronous mass spectrometry was applied to measure isomeric yield ratios of fragmentation reaction products. This approach is complementary to conventional gamma-ray spectroscopy in particular for measuring yield ratios for long-lived isomeric states. Isomeric yield ratios for the high-spin I = 19/2 states in the mirror nuclei 53Fe and 53Co are measured to study angular momentum population following the projectile fragmentation of 78Kr at energies of 480A MeV on a beryllium target. The 19/2 state isomeric ratios of 53Fe produced from different projectiles in the literature have also been extracted as a function of mass number difference between projectile and fragment (mass loss). The results are compared to ABRABLA07 model calculations. The isomeric ratios of 53Fe produced using different projectiles suggest that the theory underestimates not only the previously reported dependence on the spin but also the dependence on the mass loss.
△ Less
Submitted 22 November, 2018;
originally announced November 2018.
-
Calculation of the coupled betatron motion introduced by cooler's solenoids of CSRm
Authors:
Mei-Tang Tang,
Xiao-Dong Yang,
Li-Jun Mao,
Jie Li,
Xiao-Ming Ma,
Tai-Lai Yan,
Wen-Heng Zheng,
He Zhao,
Bo Wu,
Geng Wang,
Shuang Ruan,
Xiao-** Sha,
Jiancheng Yang,
You-** Yuan,
Jia- Wen Xia
Abstract:
Several solenoids are usually installed in electron cooler device to guide the motion of the electron beam in the cooler. However, the solenoids also have influence to the ion beam in the cooler storage ring. The transverse motion of the ion beam in storage ring will become coupled, if the solenoids installed in the electron cooler are not compensated perfectly. In this paper, the coupled transver…
▽ More
Several solenoids are usually installed in electron cooler device to guide the motion of the electron beam in the cooler. However, the solenoids also have influence to the ion beam in the cooler storage ring. The transverse motion of the ion beam in storage ring will become coupled, if the solenoids installed in the electron cooler are not compensated perfectly. In this paper, the coupled transverse motion due to the uncompensated cooler's solenoids of CSRm (The main storage ring in the IMP, Lan Zhou, China) is studied, and the coupled beam envelopes are calculated by a new method.
△ Less
Submitted 10 August, 2015;
originally announced August 2015.
-
Charge and frequency resolved isochronous mass spectrometry in storage rings: First direct mass measurement of the short-lived neutron-deficient $^{51}$Co nuclide
Authors:
P. Shuai,
H. S. Xu,
X. L. Tu,
Y. H. Zhang,
B. H. Sun,
Yu. A. Litvinov,
X. L. Yan,
K. Blaum,
M. Wang,
X. H. Zhou,
J. J. He,
Y. Sun,
K. Kaneko,
Y. J. Yuan,
J. W. Xia,
J. C. Yang,
G. Audi,
X. C. Chen,
G. B. Jia,
Z. G. Hu,
X. W. Ma,
R. S. Mao,
B. Mei,
Z. Y. Sun,
S. T. Wang
, et al. (9 additional authors not shown)
Abstract:
Revolution frequency measurements of individual ions in storage rings require sophisticated timing detectors. One of common approaches for such detectors is the detection of secondary electrons released from a thin foil due to penetration of the stored ions. A new method based on the analysis of intensities of secondary electrons was developed which enables determination of the charge of each ion…
▽ More
Revolution frequency measurements of individual ions in storage rings require sophisticated timing detectors. One of common approaches for such detectors is the detection of secondary electrons released from a thin foil due to penetration of the stored ions. A new method based on the analysis of intensities of secondary electrons was developed which enables determination of the charge of each ion simultaneously with the measurement of its revolution frequency. Although the mass-over-charge ratios of $^{51}$Co$^{27+}$ and $^{34}$Ar$^{18+}$ ions are almost identical, and therefore, the ions can not be resolved in a storage ring, by applying the new method the mass excess of the short-lived $^{51}$Co is determined for the first time to be ME($^{51}$Co)=-27342(48) keV. Shell-model calculations in the $fp$-shell nuclei compared to the new data indicate the need to include isospin-nonconserving forces.
△ Less
Submitted 8 April, 2014; v1 submitted 4 April, 2014;
originally announced April 2014.
-
Longitudinal Schottky spectra of a bunched Ne10+ ion beam at the CSRe
Authors:
W. Q. Wen,
X. Ma,
D. C. Zhang,
X. L. Zhu,
L. J. Meng,
J. Li,
H. P. Liu,
D. M. Zhao,
Z. S. Wang,
R. S. Mao,
T. C. Zhao,
J. X. Wu,
X. M. Ma,
T. L. Yan,
G. H. Li,
X. D. Yang,
Y. Liu,
J. C. Yang,
Y. J. Yuan,
J. W. Xia,
H. S. Xu,
G. Q. Xiao,
H. W. Zhao
Abstract:
The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP. For an RF-bunched ion beam, a longitudinal momentum spread of has been reached with less than 107 stored ions. The reduction of momentum spread compared with coas…
▽ More
The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP. For an RF-bunched ion beam, a longitudinal momentum spread of has been reached with less than 107 stored ions. The reduction of momentum spread compared with coasting ion beam was observed from Schottky noise signal of the bunched ion beam. In order to prepare the future laser cooling experiment at the CSRe, the RF-bunching power was modulated at 25th, 50th and 75th harmonic of the revolution frequency, effective bunching amplitudes were extracted from the Schottky spectrum analysis. Applications of Schottky noise for measuring beam lifetime with ultra-low intensity of ion beams are presented, and it is relevant to upcoming experiments on laser cooling of relativistic heavy ion beams and nuclear physics at the CSRe.
△ Less
Submitted 22 May, 2013;
originally announced May 2013.
-
The SHER-HIAF Ring Lattice Design
Authors:
X. Gao,
J. C. Yang,
J. W. Xia,
W. P. Chai,
J. Shi,
G. D. Shen
Abstract:
Super Heavy Experimental Ring (SHER) is one of the rings of the next accelerator complex High Intensity Heavy Ion Accelerator Facility (HIAF) at IMP[4]. Here, present ideas of the lattice design for the operation of the large acceptance ring are presented. The SHER ring has to be optimized for e-cooling and the lattice is designed for different modes. First of all, it is designed in the so called…
▽ More
Super Heavy Experimental Ring (SHER) is one of the rings of the next accelerator complex High Intensity Heavy Ion Accelerator Facility (HIAF) at IMP[4]. Here, present ideas of the lattice design for the operation of the large acceptance ring are presented. The SHER ring has to be optimized for e-cooling and the lattice is designed for different modes. First of all, it is designed in the so called isochronous mode as time-of-flight mass spectrometer for short-lived secondary nuclei. Secondly, SHER can also be used to be a storage ring for collecting and cooling the secondary rare isotope beams from the transport line. In order to fulfil it's purpose, the ion optics can be set to different ion optical modes.
△ Less
Submitted 21 May, 2013;
originally announced May 2013.
-
Test of detuning system for dielectronic recombination experiment at CSRm
Authors:
L. J. Meng,
X. Ma,
V. V. Parkhomchuk,
D. Yang,
V. B. Reva,
J. Li,
L. J. Mao,
X. M. Ma,
T. L. Yan,
J. W. Xia,
Y. J. Yuan,
H. S. Xu,
J. C. Yang,
G. Q. Xiao
Abstract:
The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfil the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+…
▽ More
The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfil the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+ beam was performed to examine the influence of this system on the performance of the stored ion beam. The Schottky spectra and the ion beam currents were recorded to monitor the beam status. The influence of pulse heights and widths of the detuning voltage on the ion beam was investigated. For the small pulse height, the experimental results from the Schottky spectrum were in good agreement with the theoretical results. The frequency shift in the Schottky spectrum is significantly reduced for the short pulse width. For the large pulse height, an oscillation phenomenon was observed. From the Schottky spectrum, we found the oscillation amplitude is dependent on the pulse width of detuning and the ion beam intensity. The detailed description of the phenomenon and the theoretical model based on the plasma oscillation was discussed in this paper.
△ Less
Submitted 14 February, 2012;
originally announced February 2012.