-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Search for neutrinoless quadruple beta decay of $^{136}$Xe in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens
, et al. (12 additional authors not shown)
Abstract:
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was obser…
▽ More
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experimental constraint of the neutrinoless quadruple beta decay of $^{136}$Xe.
△ Less
Submitted 5 August, 2022; v1 submitted 10 May, 2022;
originally announced May 2022.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Development of low-background photomultiplier tubes for liquid xenon detectors
Authors:
XMASS Collaboration,
K. Abe,
Y. Chen,
K. Hiraide,
K. Ichimura,
S. Imaizumi,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa
, et al. (14 additional authors not shown)
Abstract:
We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioact…
▽ More
We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioactive-contamination material; (2) the photocathode was produced with $^{39}$K-enriched potassium; and (3) the purest grade of aluminum material was used for the vacuum seal. As a result each R13111 PMT contains only about 0.4 mBq of $^{226}$Ra, less than 2 mBq of $^{238}$U, 0.3 mBq of $^{228}$Ra, 2 mBq of $^{40}$K and 0.2 mBq of $^{60}$Co. We also examined and resolved the intrinsic leakage of Xe gas into PMTs that was observed in several older models. We thus succeeded in develo** a PMT that has low background, large angular acceptance with high collection efficiency, good timing resolution, and long-term stable operation. These features are highly desirable for experiments searching for rare events beyond the standard model, such as dark matter particle interactions and neutrinoless double beta decay events.
△ Less
Submitted 18 August, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Search for exotic neutrino-electron interactions using solar neutrinos in XMASS-I
Authors:
XMASS collaboration,
K. Abe,
Y. Chen,
K. Hiraide,
K. Ichimura,
S. Imaizumi,
N. Kato,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Martens
, et al. (13 additional authors not shown)
Abstract:
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three spec…
▽ More
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three species of neutrino have common millicharge. We also set flavor dependent limits assuming the respective neutrino flavor is the only one carrying a millicharge, $7.3 \times 10^{-12} e$ for $ν_e$, $1.1 \times 10^{-11} e$ for $ν_μ$, and $1.1 \times 10^{-11} e$ for $ν_τ$. These limits are the most stringent yet obtained from direct measurements. We also obtain an upper limit for the neutrino magnetic moment of 1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for the coupling constant of dark photons in the $U(1)_{B-L}$ model of 1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$, and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
△ Less
Submitted 14 August, 2020; v1 submitted 24 May, 2020;
originally announced May 2020.
-
A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) an…
▽ More
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe.
$^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.
△ Less
Submitted 24 December, 2018; v1 submitted 16 September, 2018;
originally announced September 2018.
-
Search for WIMP-$^{129}$Xe inelastic scattering with particle identification in XMASS-I
Authors:
XMASS Collaboration,
T. Suzuki,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classific…
▽ More
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classification based on scintillation timing that distinguished $γ$-rays and $β$-rays, and simultaneous fitting of the energy spectra of $γ$-like and $β$-like samples. No evidence of a WIMP signal was found. Thus, we set the upper limits of the inelastic channel cross section at 90\% confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\; {\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm GeV}/c^2$ than the existing experimental limit.
△ Less
Submitted 19 March, 2019; v1 submitted 14 September, 2018;
originally announced September 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Direct dark matter search by annual modulation with 2.7 years of XMASS-I data
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more…
▽ More
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.
△ Less
Submitted 25 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant sig…
▽ More
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.
△ Less
Submitted 16 April, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Identification of $^{210}$Pb and $^{210}$Po in the bulk of copper samples with a low-background alpha particle counter
Authors:
XMASS collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. Th…
▽ More
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. The $^{210}$Pb contaminations of our oxygen free copper samples were 17-40 mBq/kg. Based on our investigation of copper samples in each production step, the $^{210}$Pb in oxygen free copper was understood to be a small residual of an electrolysis process. This method to measure bulk contaminations of $^{210}$Pb and $^{210}$Po could be applied to other materials.
△ Less
Submitted 9 January, 2018; v1 submitted 20 July, 2017;
originally announced July 2017.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Detectability of galactic supernova neutrinos coherently scattered on xenon nuclei in XMASS
Authors:
XMASS Collaboration
Abstract:
The coherent elastic neutrino-nucleus scattering (CEvNS) plays a crucial role at the final evolution of stars. The detection of it would be of importance in astroparticle physics. Among all available neutrino sources, galactic supernovae give the highest neutrino flux in the MeV range. Among all liquid xenon dark matter experiments, XMASS has the largest sensitive volume and light yield. The possi…
▽ More
The coherent elastic neutrino-nucleus scattering (CEvNS) plays a crucial role at the final evolution of stars. The detection of it would be of importance in astroparticle physics. Among all available neutrino sources, galactic supernovae give the highest neutrino flux in the MeV range. Among all liquid xenon dark matter experiments, XMASS has the largest sensitive volume and light yield. The possibility to detect galactic supernova via the CEvNS-process on xenon nuclei in the current XMASS detector was investigated. The total number of events integrated in about 18 seconds after the explosion of a supernova 10~kpc away from the Earth was expected to be from 3.5 to 21.1, depending on the supernova model used to predict the neutrino flux, while the number of background events in the same time window was measured to be negligible. All lead to very high possibility to detect CEvNS experimentally for the first time utilizing the combination of galactic supernovae and the XMASS detector. In case of a supernova explosion as close as Betelgeuse, the total observable events can be more than ten thousand, making it possible to distinguish different supernova models by examining the evolution of neutrino event rate in XMASS.
△ Less
Submitted 24 January, 2017; v1 submitted 5 April, 2016;
originally announced April 2016.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Search for two-neutrino double electron capture on $^{124}$Xe with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
J. Liu,
K. Martens,
Y. Suzuki,
R. Fujita,
K. Hosokawa
, et al. (19 additional authors not shown)
Abstract:
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$X…
▽ More
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$Xe is performed using 165.9 days of data collected with the XMASS-I liquid xenon detector. No significant excess above background was observed and we set a lower limit on the half-life as $4.7 \times 10^{21}$ years at 90% confidence level. The obtained limit has ruled out parts of some theoretical expectations. We obtain a lower limit on the $^{126}$Xe two-neutrino double electron capture half-life of $4.3 \times 10^{21}$ years at 90% confidence level as well.
△ Less
Submitted 25 May, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon
Authors:
K. Ueshima,
K. Abe,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
Y. Koshio,
J. Liu,
K. Martens,
S. Moriyama,
M. Nakahata,
H. Nishiie,
H. Ogawa,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
M. Yamashita,
K. Fujii,
I. Murayama,
S. Nakamura,
K. Otsuka,
Y. Takeuchi,
Y. Fukuda,
K. Nishijima
, et al. (12 additional authors not shown)
Abstract:
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a singl…
▽ More
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.
△ Less
Submitted 11 June, 2011;
originally announced June 2011.