-
Accurate reference spectra of HD in H$_2$/He bath for planetary applications
Authors:
H. Jóźwiak,
N. Stolarczyk,
K. Stankiewicz,
M. Zaborowski,
D. Lisak,
S. Wójtewicz,
P. Jankowski,
K. Patkowski,
K. Szalewicz,
F. Thibault,
I. E. Gordon,
P. Wcisło
Abstract:
The hydrogen deuteride (HD) molecule is an important deuterium tracer in astrophysical studies. The atmospheres of gas giants are dominated by molecular hydrogen, and simultaneous observation of H$_2$ and HD lines provides reliable information on the D/H ratios on these planets. The reference spectroscopic parameters play a crucial role in such studies. Under thermodynamic conditions encountered i…
▽ More
The hydrogen deuteride (HD) molecule is an important deuterium tracer in astrophysical studies. The atmospheres of gas giants are dominated by molecular hydrogen, and simultaneous observation of H$_2$ and HD lines provides reliable information on the D/H ratios on these planets. The reference spectroscopic parameters play a crucial role in such studies. Under thermodynamic conditions encountered in these atmospheres, the spectroscopic studies of HD require not only the knowledge of line intensities and positions but also accurate reference data on pressure-induced line shapes and shifts. Our aim is to provide accurate collision-induced line-shape parameters for HD lines that cover any thermodynamic conditions relevant to the atmospheres of giant planets, i.e., any relevant temperature, pressure, and perturbing gas (the H$_2$/He mixture) composition. We perform quantum-scattering calculations on a new highly accurate ab initio potential energy surface, and we use scattering S-matrices obtained this way to determine the collision-induced line-shape parameters. We use the cavity ring-down spectroscopy for validation of our theoretical methodology. We report accurate collision-induced line-shape parameters for the pure rotational R(0), R(1), and R(2) lines, the most relevant HD lines for the investigations of atmospheres of the giant planets. Besides the basic Voigt-profile collisional parameters (i.e. the broadening and shift parameters), we also report their speed dependences and the complex Dicke parameter, which can influence the effective width and height of the HD lines up to almost a factor of 2 for giant planet conditions. The sub-percent-level accuracy, reached in this work, considerably improves the previously available data. All the reported parameters are consistent with the HITRAN database format, hence allowing for the use of HAPI for generating the beyond-Voigt spectra of HD.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
Heterodyne dispersive cavity ring-down spectroscopy exploiting eigenmode frequencies for high-fidelity measurements
Authors:
Agata Cygan,
Szymon Wójtewicz,
Hubert Jóźwiak,
Grzegorz Kowzan,
Nikodem Stolarczyk,
Katarzyna Bielska,
Piotr Wcisło,
Roman Ciuryło,
Daniel Lisak
Abstract:
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by…
▽ More
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by the ring-down cavity electromagnetic field, not explored in conventional CRDS, for high-fidelity spectroscopy. Instead of measuring only the decaying light intensity, we perform heterodyne detection of ring-downs followed by Fourier analysis to provide exact frequencies of optical cavity modes and a dispersive spectrum of a gas sample from them. This approach is insensitive to inaccuracies in light intensity measurements and eliminates the problem of detector band nonlinearity, the main cause of measurement error in traditional CRDS. Using the CO and HD line intensities as examples, we demonstrate the sub-permille accuracy of our method, confirmed by the best ab initio results, and the long-term repeatability of our dispersion measurements at 10^(-4) level. Such results have not been achieved in optical spectroscopy before. The high accuracy of the presented method indicates its potential in atmospheric studies, isotope ratio metrology, thermometry, and the establishment of primary gas standards.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Stimulated-Raman-Scattering Metrology
Authors:
M. Lamperti,
L. Rutkowski,
D. Ronchetti,
D. Gatti,
R. Gotti,
G. Cerullo,
F. Thibault,
H. Jóźwiak,
S. Wójtewicz,
P. Masłowski,
P. Wcisło,
D. Polli,
M. Marangoni
Abstract:
Frequency combs have revolutionized optical frequency metrology, allowing one to determine highly accurate transition frequencies of a wealth of molecular species. Despite a recognized scientific interest, these progresses have only marginally benefited infrared-inactive transitions, due to their inherently weak cross-sections. Here we overcome this limitation by introducing stimulated-Raman-scatt…
▽ More
Frequency combs have revolutionized optical frequency metrology, allowing one to determine highly accurate transition frequencies of a wealth of molecular species. Despite a recognized scientific interest, these progresses have only marginally benefited infrared-inactive transitions, due to their inherently weak cross-sections. Here we overcome this limitation by introducing stimulated-Raman-scattering metrology, where a frequency comb is exploited to calibrate the frequency detuning between the pump and Stokes excitation lasers. We apply this approach to molecular hydrogen to test quantum electrodynamics. We measure the transition frequency of the Q(1) fundamental line of H$_2$ around 4155 cm$^{-1}$ with few parts-per-billion uncertainty, which is comparable to the theoretical benchmark of ab initio calculations and more than a decade better than the experimental state of the art. Our comb-calibrated stimulated Raman scattering spectrometer extends the toolkit of optical frequency metrology as it can be applied, with simple technical changes, to many other infrared-inactive transitions, over a 50-5000 cm$^{-1}$ range that covers also purely rotational bands.
△ Less
Submitted 8 July, 2022;
originally announced July 2022.
-
Ultra-high finesse cavity-enhanced spectroscopy for accurate tests of quantum electrodynamics for molecules
Authors:
M. Zaborowski,
M. Słowiński,
K. Stankiewicz,
F. Thibault,
A. Cygan,
H. Jóźwiak,
G. Kowzan,
P. Masłowski,
A. Nishiyama,
N. Stolarczyk,
S. Wójtewicz,
R. Ciuryło,
D. Lisak,
P. Wcisło
Abstract:
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reach…
▽ More
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reached 40 kHz of statistical uncertainty and 161 kHz of absolute accuracy, achieving the highest accuracy for homonuclear isotopologues of molecular hydrogen. The accuracy of our measurement corresponds to the fifth significant digit of the leading term in QED correction. We observe 2.3$σ$ discrepancy with the recent theoretical value.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Measurement of electron-calcium ionization integral cross section using an ion trap with a low-energy, pulsed electron gun
Authors:
Łukasz Kłosowski,
Mariusz Piwiński,
Szymon Wójtewicz,
Daniel Lisak
Abstract:
An apparatus for production of various atomic and molecular ions inside a linear Paul trap has been set up. The system applies a custom-made, low energy, pulsed electron gun to produce ions in electron impact process. Such ionization method can find some interesting possible applications such as derivation of ions inaccessible other-ways, which can be used in molecular ion experiments. The techniq…
▽ More
An apparatus for production of various atomic and molecular ions inside a linear Paul trap has been set up. The system applies a custom-made, low energy, pulsed electron gun to produce ions in electron impact process. Such ionization method can find some interesting possible applications such as derivation of ions inaccessible other-ways, which can be used in molecular ion experiments. The technique allows also for determination of cross sections for various collisional processes.
As a feasibility study, the apparatus was used for determination of ionization integral cross section of calcium in the 16--160 eV range of electron impact energy. The obtained cross section values are discussed and compared with existing data sets.
△ Less
Submitted 4 May, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.