Target Mass Monitoring and Instrumentation in the Daya Bay Antineutrino Detectors
Authors:
Henry R. Band,
Jeffrey J. Cherwinka,
Lee S. Greenler,
Karsten M. Heeger,
Paul Hinrichs,
Li Kang,
Christine A. Lewis,
Shanfeng Li,
Shengxin Lin,
Michael C. McFarlane,
Wei Wang,
David M. Webber,
Yadong Wei,
Thomas S. Wise,
Qiang Xiao,
Li Yang,
Zhijian Zhang
Abstract:
The Daya Bay experiment measures sin^2 2θ_13 using functionally identical antineutrino detectors located at distances of 300 to 2000 meters from the Daya Bay nuclear power complex. Each detector consists of three nested fluid volumes surrounded by photomultiplier tubes. These volumes are coupled to overflow tanks on top of the detector to allow for thermal expansion of the liquid. Antineutrinos ar…
▽ More
The Daya Bay experiment measures sin^2 2θ_13 using functionally identical antineutrino detectors located at distances of 300 to 2000 meters from the Daya Bay nuclear power complex. Each detector consists of three nested fluid volumes surrounded by photomultiplier tubes. These volumes are coupled to overflow tanks on top of the detector to allow for thermal expansion of the liquid. Antineutrinos are detected through the inverse beta decay reaction on the proton-rich scintillator target. A precise and continuous measurement of the detector's central target mass is achieved by monitoring the the fluid level in the overflow tanks with cameras and ultrasonic and capacitive sensors. In addition, the monitoring system records detector temperature and levelness at multiple positions. This monitoring information allows the precise determination of the detectors' effective number of target protons during data taking. We present the design, calibration, installation and in-situ tests of the Daya Bay real-time antineutrino detector monitoring sensors and readout electronics.
△ Less
Submitted 4 March, 2013; v1 submitted 29 June, 2012;
originally announced June 2012.
The low-temperature energy calibration system for the CUORE bolometer array
Authors:
S. Sangiorgio,
L. M. Ejzak,
K. M. Heeger,
R. H. Maruyama,
A. Nucciotti,
M. Olcese,
T. S. Wise,
A. L. Woodcraft
Abstract:
The CUORE experiment will search for neutrinoless double beta decay (0nDBD) of 130Te using an array of 988 TeO_2 bolometers operated at 10 mK in the Laboratori Nazionali del Gran Sasso (Italy). The detector is housed in a large cryogen-free cryostat cooled by pulse tubes and a high-power dilution refrigerator. The TeO_2 bolometers measure the event energies, and a precise and reliable energy cal…
▽ More
The CUORE experiment will search for neutrinoless double beta decay (0nDBD) of 130Te using an array of 988 TeO_2 bolometers operated at 10 mK in the Laboratori Nazionali del Gran Sasso (Italy). The detector is housed in a large cryogen-free cryostat cooled by pulse tubes and a high-power dilution refrigerator. The TeO_2 bolometers measure the event energies, and a precise and reliable energy calibration is critical for the successful identification of candidate 0nDBD and background events. The detector calibration system under development is based on the insertion of 12 gamma-sources that are able to move under their own weight through a set of guide tubes that route them from deployment boxes on the 300K flange down into position in the detector region inside the cryostat. The CUORE experiment poses stringent requirements on the maximum heat load on the cryostat, material radiopurity, contamination risk and the ability to fully retract the sources during normal data taking. Together with the integration into a unique cryostat, this requires careful design and unconventional solutions. We present the design, challenges, and expected performance of this low-temperature energy calibration system.
△ Less
Submitted 3 August, 2009;
originally announced August 2009.