-
Laser spectroscopy of the $^2S_{1/2} - ^2P_{1/2}$, $^2P_{3/2}$ transitions in stored and cooled relativistic C$^{3+}$ ions
Authors:
D. Winzen,
V. Hannen,
M. Bussmann,
A. Buß,
C. Egelkamp,
L. Eidam,
Z. Huang,
D. Kiefer,
S. Klammes,
T. Kühl,
M. Loeser,
X. Ma,
W. Nörtershäuser,
H. -W. Ortjohann,
R. Sánchez,
M. Siebold,
T. Stöhlker,
J. Ullmann,
J. Vollbrecht,
T. Walther,
H. Wang,
C. Weinheimer,
D. F. A. Winters
Abstract:
The $^2S_{1/2} - ^2P_{1/2}$ and $^2S_{1/2} - ^2P_{3/2}$ transitions in Li-like carbon ions stored and cooled at a velocity of $β\approx 0.47$ in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection…
▽ More
The $^2S_{1/2} - ^2P_{1/2}$ and $^2S_{1/2} - ^2P_{3/2}$ transitions in Li-like carbon ions stored and cooled at a velocity of $β\approx 0.47$ in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry has been resolved and agreement between experiment and theory is confirmed.
△ Less
Submitted 6 May, 2021; v1 submitted 27 October, 2020;
originally announced October 2020.
-
New Test of Modulated Electron Capture Decay of Hydrogen-Like $^{142}$Pm Ions: Precision Measurement of Purely Exponential Decay
Authors:
F. C. Ozturk,
B. Akkus,
D. Atanasov,
H. Beyer,
F. Bosch,
D. Boutin,
C. Brandau,
P. Bühler,
R. B. Cakirli,
R. J. Chen,
W. D. Chen,
X. C. Chen,
I. Dillmann,
C. Dimopoulou,
W. Enders,
H. G. Essel,
T. Faestermann,
O. Forstner,
B. S. Gao,
H. Geissel,
R. Gernhäuser,
R. E. Grisenti,
A. Gumberidze,
S. Hagmann,
T. Heftrich
, et al. (70 additional authors not shown)
Abstract:
An experiment addressing electron capture (EC) decay of hydrogen-like $^{142}$Pm$^{60+}$ ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed d…
▽ More
An experiment addressing electron capture (EC) decay of hydrogen-like $^{142}$Pm$^{60+}$ ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7) s$^{-1}$ for automatic analysis and 0.0141(7) s$^{-1}$ for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).
△ Less
Submitted 9 August, 2019; v1 submitted 16 July, 2019;
originally announced July 2019.
-
Radiative electron capture as a tunable source of highly linearly polarized x-rays
Authors:
M. Vockert,
G. Weber,
H. Bräuning,
A. Surzhykov,
C. Brandau,
S. Fritzsche,
S. Geyer,
S. Hagmann,
S. Hess,
C. Kozhuharov,
R. Märtin,
N. Petridis,
R. Hess,
S. Trotsenko,
Yu. A. Litvinov,
J. Glorius,
A. Gumberidze,
M. Steck,
S. Litvinov,
T. Gaßner,
P. -M. Hillenbrand,
M. Lestinsky,
F. Nolden,
M. S. Sanjari,
U. Popp
, et al. (5 additional authors not shown)
Abstract:
The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U$^{92+}$. Owing to the improved detector technology a significant gain in precisi…
▽ More
The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U$^{92+}$. Owing to the improved detector technology a significant gain in precision of the present polarization measurement is achieved compared to the previously published results. The obtained data confirms that for medium-Z ions such as Xe the REC process is a source of highly polarized x-rays which can easily be tuned with respect to the degree of linear polarization and the photon energy. We argue, in particular, that for relatively low energies the photons emitted under large angles are almost fully linear polarized.
△ Less
Submitted 9 May, 2019; v1 submitted 22 February, 2019;
originally announced February 2019.
-
High-resolution measurement of the time-modulated orbital electron capture and of the $β^+$ decay of hydrogen-like $^{142}$Pm$^{60+}$ ions
Authors:
The Two-Body-Weak-Decays Collaboration,
:,
P. Kienle,
F. Bosch,
P. Bühler,
T. Faestermann,
Yu. A. Litvinov,
M. S. Sanjari,
D. B. Shubina,
N. Winckler,
D. Atanasov,
H. Geissel,
V. Ivanova,
X. L. Yan,
D. Boutin,
C. Brandau,
I. Dillmann,
Ch. Dimopoulou,
R. Hess,
P. -M. Hillebrand,
T. Izumikawa,
R. Knöbel,
J. Kurcewicz,
N. Kuzminchuk,
M. Lestinsky
, et al. (24 additional authors not shown)
Abstract:
The periodic time modulations, found recently in the two-body orbital electron-capture (EC) decay of both, hydrogen-like $^{140}$Pr$^{58+}$ and $^{142}$Pm$^{60+}$ ions, with periods near to 7s and amplitudes of about 20%, were re-investigated for the case of $^{142}$Pm$^{60+}$ by using a 245 MHz resonator cavity with a much improved sensitivity and time resolution. We observed that the exponential…
▽ More
The periodic time modulations, found recently in the two-body orbital electron-capture (EC) decay of both, hydrogen-like $^{140}$Pr$^{58+}$ and $^{142}$Pm$^{60+}$ ions, with periods near to 7s and amplitudes of about 20%, were re-investigated for the case of $^{142}$Pm$^{60+}$ by using a 245 MHz resonator cavity with a much improved sensitivity and time resolution. We observed that the exponential EC decay is modulated with a period $T = 7.11(11)$s, in accordance with a modulation period $T = 7.12(11)$ s as obtained from simultaneous observations with a capacitive pick-up, employed also in the previous experiments. The modulation amplitudes amount to $a_R = 0.107(24)$ and $a_P = 0.134(27)$ for the 245 MHz resonator and the capacitive pick-up, respectively. These new results corroborate for both detectors {\it exactly} our previous findings of modulation periods near to 7s, though with {\it distinctly smaller} amplitudes. Also the three-body $β^+$ decays have been analyzed. For a supposed modulation period near to 7s we found an amplitude $a = 0.027(27)$, compatible with $a = 0$ and in agreement with the preliminary result $a = 0.030(30)$ of our previous experiment. These observations could point at weak interaction as origin of the observed 7s-modulation of the EC decay. Furthermore, the data suggest that interference terms occur in the two-body EC decay, although the neutrinos are not directly observed.
△ Less
Submitted 27 September, 2013;
originally announced September 2013.
-
Detection system for forward emitted photons at the Experimental Storage Ring at GSI
Authors:
V. Hannen,
D. Anielski,
C. Geppert,
R. Jöhren,
T. Kühl,
M. Lochmann,
R. López-Coto,
W. Nörtershäuser,
H. -W. Ortjohann,
R. Sánchez,
J. Vollbrecht,
C. Weinheimer,
D. F. A. Winters
Abstract:
A single photon counting system has been developed for efficient detection of forward emitted fluorescence photons at the Experimental Storage Ring (ESR) at GSI. The system employs a movable parabolic mirror with a central slit that can be positioned around the ion beam and a selected low noise photomultiplier for detection of the collected photons. Compared to the previously used system of mirror…
▽ More
A single photon counting system has been developed for efficient detection of forward emitted fluorescence photons at the Experimental Storage Ring (ESR) at GSI. The system employs a movable parabolic mirror with a central slit that can be positioned around the ion beam and a selected low noise photomultiplier for detection of the collected photons. Compared to the previously used system of mirror segments installed inside the ESR the collection efficiency for forward-emitted photons is improved by more than a factor of 5. No adverse effects on the stored ion beam have been observed during operation besides a small drop in the ion current of about 5% during movement of the mirror into the beam position. The new detection system has been used in the LIBELLE experiment at ESR and enabled for the first time the detection of the ground-state hyperfine M1 transition in lithium-like bismuth (209Bi80+) in a laser-spectroscopy measurement.
△ Less
Submitted 10 October, 2013; v1 submitted 17 May, 2013;
originally announced May 2013.
-
HITRAP: A facility at GSI for highly charged ions
Authors:
H. -J. Kluge,
T. Beier,
K. Blaum,
L. Dahl,
S. Eliseev,
F. Herfurth,
B. Hofmann,
O. Kester,
S. Koszudowski,
C. Kozhuharov,
G. Maero,
W. Noertershaeuser,
J. Pfister,
W. Quint,
U. Ratzinger,
A. Schempp,
R. Schuch,
T. Stoehlker,
R. C. Thompson,
M. Vogel,
G. Vorobjev,
D. F. A. Winters,
G. Werth
Abstract:
An overview and status report of the new trap** facility for highly charged ions at the Gesellschaft fuer Schwerionenforschung is presented. The construction of this facility started in 2005 and is expected to be completed in 2008. Once operational, highly charged ions will be loaded from the experimental storage ring ESR into the HITRAP facility, where they are decelerated and cooled. The kin…
▽ More
An overview and status report of the new trap** facility for highly charged ions at the Gesellschaft fuer Schwerionenforschung is presented. The construction of this facility started in 2005 and is expected to be completed in 2008. Once operational, highly charged ions will be loaded from the experimental storage ring ESR into the HITRAP facility, where they are decelerated and cooled. The kinetic energy of the initially fast ions is reduced by more than fourteen orders of magnitude and their thermal energy is cooled to cryogenic temperatures. The cold ions are then delivered to a broad range of atomic physics experiments.
△ Less
Submitted 30 October, 2007;
originally announced October 2007.
-
Scintillation light produced by low-energy beams of highly-charged ions
Authors:
M. Vogel,
D. F. A. Winters,
H. Ernst,
H. Zimmermann,
O. Kester
Abstract:
Measurements have been performed of scintillation light intensities emitted from various inorganic scintillators irradiated with low-energy beams of highly-charged ions from an electron beam ion source (EBIS) and an electron cyclotron resonance ion source (ECRIS). Beams of xenon ions Xe$^{q+}$ with various charge states between $q$=2 and $q$=18 have been used at energies between 5 keV and 17.5 k…
▽ More
Measurements have been performed of scintillation light intensities emitted from various inorganic scintillators irradiated with low-energy beams of highly-charged ions from an electron beam ion source (EBIS) and an electron cyclotron resonance ion source (ECRIS). Beams of xenon ions Xe$^{q+}$ with various charge states between $q$=2 and $q$=18 have been used at energies between 5 keV and 17.5 keV per charge generated by the ECRIS. The intensity of the beam was typically varied between 1 and 100 nA. Beams of highly charged residual gas ions have been produced by the EBIS at 4.5 keV per charge and with low intensities down to 100 pA. The scintillator materials used are flat screens of P46 YAG and P43 phosphor. In all cases, scintillation light emitted from the screen surface was detected by a CCD camera. The scintillation light intensity has been found to depend linearly on the kinetic ion energy per time deposited into the scintillator, while up to $q$=18 no significant contribution from the ions' potential energy was found. We discuss the results on the background of a possible use as beam diagnostics e.g. for the new HITRAP facility at GSI, Germany.
△ Less
Submitted 25 October, 2007;
originally announced October 2007.
-
Atomic physics experiments with trapped and cooled highly charged ions
Authors:
H. -J. Kluge,
W. Quint,
D. F. A. Winters
Abstract:
Trap** and cooling techniques have become very important for many fundamental experiments in atomic physics. When applied to highly charged ions confined in Penning traps, these procedures are very effective for testing quantum electrodynamics in extreme electromagnetic fields produced by heavy highly charged ions such as uranium U$^{91+}$. In addition, fundamental constants or nuclear ground…
▽ More
Trap** and cooling techniques have become very important for many fundamental experiments in atomic physics. When applied to highly charged ions confined in Penning traps, these procedures are very effective for testing quantum electrodynamics in extreme electromagnetic fields produced by heavy highly charged ions such as uranium U$^{91+}$. In addition, fundamental constants or nuclear ground state properties can be determined with high accuracy in these simple systems. Finally, by studying a single trapped radioactive ion, its nuclear decay can be studied in detail by observing the disappearance of the signal of the mother and the appearance of that of the daughter isotope. Such experiments on highly charged ions at extremely low energy will become possible by the HITRAP facility which is currently being built up at GSI. Also the future Facility for Antiproton and Ion Research (FAIR) will be briefly described which is expected to be operational by 2014.
△ Less
Submitted 26 April, 2007;
originally announced April 2007.
-
Laser spectroscopy of hyperfine structure in highly-charged ions: a test of QED at high fields
Authors:
D. F. A. Winters,
M. Vogel,
D. M. Segal,
R. C. Thompson,
W. Noertershaeuser
Abstract:
An overview is presented of laser spectroscopy experiments with cold, trapped, highly-charged ions, which will be performed at the HITRAP facility at GSI in Darmstadt (Germany). These high-resolution measurements of ground state hyperfine splittings will be three orders of magnitude more precise than previous measurements. Moreover, from a comparison of measurements of the hyperfine splittings i…
▽ More
An overview is presented of laser spectroscopy experiments with cold, trapped, highly-charged ions, which will be performed at the HITRAP facility at GSI in Darmstadt (Germany). These high-resolution measurements of ground state hyperfine splittings will be three orders of magnitude more precise than previous measurements. Moreover, from a comparison of measurements of the hyperfine splittings in hydrogen- and lithium-like ions of the same isotope, QED effects at high electromagnetic fields can be determined within a few percent. Several candidate ions suited for these laser spectroscopy studies are presented.
△ Less
Submitted 26 April, 2007; v1 submitted 4 April, 2007;
originally announced April 2007.
-
Electronic detection of charged particle effects in a Penning trap
Authors:
D. F. A. Winters,
M. Vogel,
D. M. Segal,
R. C. Thompson
Abstract:
We present a thorough analysis of the electronic detection of charged particles, confined in a Penning trap, via image charges induced in the trap electrodes. Trap** of charged particles in an electrode structure leads to frequency shifts, which are due to image charge and space charge effects. These effects are of importance for Penning trap experiments which involve high charge densities or…
▽ More
We present a thorough analysis of the electronic detection of charged particles, confined in a Penning trap, via image charges induced in the trap electrodes. Trap** of charged particles in an electrode structure leads to frequency shifts, which are due to image charge and space charge effects. These effects are of importance for Penning trap experiments which involve high charge densities or require high precision in the motional frequencies. Our analysis of image charges shows that only (higher order) odd powers of the particle displacement lead to induced charge differences, giving rise to a signal. This implies that, besides the centre-of-mass frequency of a trapped particle cloud, also higher order individual particle frequencies induce a signal, which can be picked up by an electronic detection circuit attached to the trap electrodes. We also derive analytic expressions for the image charge and space charge induced frequency shifts and perform simulations of space charge effects. In relation to this, we discuss the consequences of the shifted particle frequencies for resistive cooling of the particle motion.
△ Less
Submitted 4 August, 2006;
originally announced August 2006.
-
Novel designs for Penning ion traps
Authors:
J. R. Castrejon-Pita,
H. Ohadi,
D. R. Crick,
D. F. A. Winters,
D. M. Segal,
R. C. Thompson
Abstract:
We present a number of alternative designs for Penning ion traps suitable for quantum information processing (QIP) applications with atomic ions. The first trap design is a simple array of long straight wires which allows easy optical access. A prototype of this trap has been built to trap Ca+ and a simple electronic detection scheme has been employed to demonstrate the operation of the trap. An…
▽ More
We present a number of alternative designs for Penning ion traps suitable for quantum information processing (QIP) applications with atomic ions. The first trap design is a simple array of long straight wires which allows easy optical access. A prototype of this trap has been built to trap Ca+ and a simple electronic detection scheme has been employed to demonstrate the operation of the trap. Another trap design consists of a conducting plate with a hole in it situated above a continuous conducting plane. The final trap design is based on an array of pad electrodes. Although this trap design lacks the open geometry of the traps described above, the pad design may prove useful in a hybrid scheme in which information processing and qubit storage take place in different types of trap. The behaviour of the pad traps is simulated numerically and techniques for moving ions rapidly between traps are discussed. Future experiments with these various designs are discussed. All of the designs lend themselves to the construction of multiple trap arrays, as required for scalable ion trap QIP.
△ Less
Submitted 22 March, 2006;
originally announced March 2006.
-
Proposed precision laser spectrometer for trapped, highly charged ions
Authors:
M. Vogel,
D. F. A. Winters,
D. M. Segal,
R. C. Thompson
Abstract:
We propose a novel type of precision laser spectrometer for trapped, highly charged ions nearly at rest. It consists of a cylindrical open-endcap Penning trap in which an externally produced bunch of highly charged ions can be confined and investigated by means of laser spectroscopy. The combination of confinement, cooling and compression of a dense ion cloud will allow the ground state hyperfin…
▽ More
We propose a novel type of precision laser spectrometer for trapped, highly charged ions nearly at rest. It consists of a cylindrical open-endcap Penning trap in which an externally produced bunch of highly charged ions can be confined and investigated by means of laser spectroscopy. The combination of confinement, cooling and compression of a dense ion cloud will allow the ground state hyperfine splitting in highly charged ions to be measured with an accuracy three orders of magnitude better than in any previous experiment. A systematic study of different charge states and different isotopes of the same element allows for highly sensitive tests of bound-state QED and for a precision determination of nuclear properties. Apart from stable isotopes, also radioactive species with half-lives longer than about one hour can be investigated.
△ Less
Submitted 21 October, 2005;
originally announced October 2005.
-
Plans for laser spectroscopy of trapped cold hydrogen-like HCI
Authors:
D. F. A. Winters,
A. M. Abdulla,
J. R. Castrejon Pita,
A. de Lange,
D. M. Segal,
R. C. Thompson
Abstract:
Laser spectroscopy studies are being prepared to measure the 1s ground state hyperfine splitting in trapped cold highly charged ions. The purpose of such experiments is to test quantum electrodynamics in the strong electric field regime. These experiments form part of the HITRAP project at GSI. A brief review of the planned experiments is presented.
Laser spectroscopy studies are being prepared to measure the 1s ground state hyperfine splitting in trapped cold highly charged ions. The purpose of such experiments is to test quantum electrodynamics in the strong electric field regime. These experiments form part of the HITRAP project at GSI. A brief review of the planned experiments is presented.
△ Less
Submitted 19 January, 2005;
originally announced January 2005.