A Further Measurement of the beta-Delayed alpha-Particle Emission of 16N
Authors:
R. H. France III,
E. L. Wilds,
J. E. McDonald,
M. Gai
Abstract:
We measured the beta-delayed alpha-particle emission spectrum of 16N with a sensitivity for beta-decay branching ratios of the order of 10-10. The 16N nuclei were produced using the d(15N,16N)p reaction with 70 MeV 15N beams and a deuterium gas target 7.5 cm long at a pressure of 1250 torr. The 16N nuclei were collected (over 10 s) using a thin aluminum foil with an areal density of 180 mu g/cm2…
▽ More
We measured the beta-delayed alpha-particle emission spectrum of 16N with a sensitivity for beta-decay branching ratios of the order of 10-10. The 16N nuclei were produced using the d(15N,16N)p reaction with 70 MeV 15N beams and a deuterium gas target 7.5 cm long at a pressure of 1250 torr. The 16N nuclei were collected (over 10 s) using a thin aluminum foil with an areal density of 180 mu g/cm2 tilted at 7 Deg with respect to the beam. The activity was transferred to the counting area by means of a step** motor in less than 3 s with the counting carried out over 8 s. The beta-delayed alpha-particles were measured using a time of flight method to achieve a sufficiently low background. Standard calibration sources (148Gd, 241Am, 208,209Po, and 227Ac) as well as alpha-particles and 7Li from the 10B(n,alpha)7Li reaction were used for an accurate energy calibration. The energy resolution of the catcher foil (180-220 keV) was calculated and the time of flight resolution (3-10 nsec) was measured using the beta-delayed alpha-particle emission from 8Li that was produced using the d(7Li,8Li)p reaction with the same setup. The line shape was corrected to account for the variation in the energy and time resolution and a high statistics spectrum of the beta-delayed alpha-particle emission of 16N is reported. However, our data (as well as earlier Mainz data and unpublished Seattle data) do not agree with an earlier measurement of the beta-delayed alpha-particle emission of 16N taken at TRIUMF after averaging over the energy resolution of our collection system. This disagreement, amongst other issues, prohibits accurate inclusion of the f-wave component in the R-matrix analysis.
△ Less
Submitted 8 February, 2007;
originally announced February 2007.
In Beam Tests of Implanted Helium Targets
Authors:
J. E. McDonald,
R. H. France III,
R. A. Jarvis,
M. W. Ahmed,
M. A. Blackston,
Th. Delbar,
M. Gai,
T. J. Kading,
Y. Parpottas,
B. A. Perdue,
R. M. Prior,
D. A. Rubin,
M. C. Spraker,
J. D. Yeomans,
L. Weissman,
H. R. Weller,
E. L. Wilds Jr,
;,
UHartford,
GCSU,
LNS/UConn,
TUNL/Duke,
UCL/LLN,
Yale,
NGCSU
Abstract:
Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. He…
▽ More
Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. Helium implantation into the very thin (approximately 80-100 ug/cm^2) aluminum foils failed to produce useful targets (with only approximately 10% of the helium retained) due to an under estimation of the range by the code SRIM. The range of low energy helium in aluminum predicted by Northcliffe and Shilling and the NIST online tabulation are observed on the other hand to over estimate the range of low energy helium ions in aluminum. An attempt to increase the amount of helium by implanting a second deeper layer was also carried out, but it did not significantly increase the helium content beyond the blistering limit (approximately 6 x 10^17 helium/cm^2). The implanted targets were bombarded with moderately intense 4He and 16O beams of 50-100 particle nA . Rutherford Back Scattering of 1.0 and 2.5 MeV proton beams and recoil helium from 15.0 MeV oxygen beams were used to study the helium content and profile before, during and after bombardments. We observed the helium content and profile to be very stable even after a prolonged bombardment (up to two days) with moderately intense beams of 16O or 4He. Helium implanted into thin (aluminum) foils is a good choice for thin helium targets needed, for example, for a measurement of the 3he(a,g)7Be reaction and the associated S34 astrophysical cross section factor (S-factor).
△ Less
Submitted 16 August, 2006;
originally announced August 2006.