-
Assessing the impact of valence sd neutrons and protons on fusion
Authors:
Varinderjit Singh,
J. Vadas,
T. K. Steinbach,
B. B. Wiggins,
S. Hudan,
R. T. deSouza
Abstract:
Experimental above-barrier fusion cross-sections for $^{17}$F + $^{12}$C are compared to the fusion excitation functions for $^{16,18}$O, $^{19}$F, and $^{20}$Ne ions on a carbon target. In comparing the different systems both the differing static size of the incident ions and changes in fusion barrier are accounted for by examining the reduced fusion cross-section. Remaining trends of the fusion…
▽ More
Experimental above-barrier fusion cross-sections for $^{17}$F + $^{12}$C are compared to the fusion excitation functions for $^{16,18}$O, $^{19}$F, and $^{20}$Ne ions on a carbon target. In comparing the different systems both the differing static size of the incident ions and changes in fusion barrier are accounted for by examining the reduced fusion cross-section. Remaining trends of the fusion cross-section above the barrier which reflect the sensitive interplay of the sd protons and neutrons are observed. The experimental data are also compared to both a widely-used analytical model of near-barrier fusion, as well as a time-dependent Hartree-Fock model. Both models fail to describe the trends observed.
△ Less
Submitted 3 March, 2021; v1 submitted 12 October, 2020;
originally announced October 2020.
-
Development of a compact ExB microchannel plate detector for beam imaging
Authors:
B. B. Wiggins,
Varinderjit Singh,
J. Vadas,
J. Huston,
T. K. Steinbach,
S. Hudan,
R. T. deSouza
Abstract:
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an $α$-source with an intervening mask that consists of a series of precisely-machined s…
▽ More
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an $α$-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520$μ$m FWHM, which was improved to 413$μ$m FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatial resolution of 413$μ$m FWHM corresponds to an intrinsic resolution of 334$μ$m FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.
△ Less
Submitted 18 September, 2017;
originally announced September 2017.
-
Disentangling the role of vibration, rotation, and neutron transfer in the fusion of neutron-rich mid-mass nuclei
Authors:
J. Vadas,
Varinderjit Singh,
B. B. Wiggins,
J. Huston,
S. Hudan,
R. T. deSouza,
Z. Lin,
C. J. Horowitz,
A. Chbihi,
D. Ackermann,
M. Famiano,
K. W. Brown
Abstract:
We report the first measurement of the fusion excitation functions for $^{39,47}$K + $^{28}$Si at near-barrier energies. Evaporation residues resulting from the fusion process were identified by direct measurement of their energy and time-of-flight with high geometric efficiency. At the lowest incident energy, the cross-section measured for the neutron-rich $^{47}$K induced reaction is ~6 times la…
▽ More
We report the first measurement of the fusion excitation functions for $^{39,47}$K + $^{28}$Si at near-barrier energies. Evaporation residues resulting from the fusion process were identified by direct measurement of their energy and time-of-flight with high geometric efficiency. At the lowest incident energy, the cross-section measured for the neutron-rich $^{47}$K induced reaction is ~6 times larger than that of the $β$-stable system. The experimental data are compared with both a dynamical deformation model and coupled channels calculations (CCFULL).
△ Less
Submitted 18 September, 2017;
originally announced September 2017.
-
High-rate axial-field ionization chamber for particle identification of radioactive beams
Authors:
J. Vadas,
Varinderjit Singh,
G. Visser,
A. Alexander,
S. Hudan,
J. Huston,
B. B. Wiggins,
A. Chbihi,
M. Famiano,
M. M. Bischak,
R. T. deSouza
Abstract:
The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the detector presents only three 0.5 $μ$m/cm$^2$ foils to the beam in addition to the detector gas. A fast charge sensitive amplifier (CSA) integrated into the detector…
▽ More
The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the detector presents only three 0.5 $μ$m/cm$^2$ foils to the beam in addition to the detector gas. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a risetime of 60-70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate. Tests with an $α$ source establish the detector energy resolution as $\sim$8 $\%$ for an energy deposit of $\sim$3.5 MeV. The energy resolution with beams of 2.5 and 4.0 MeV/A $^{39}$K ions and the dependence of the energy resolution on beam intensity is measured. At an instantaneous rate of 3 x 10$^5$ ions/s the energy resolution has degraded to 14% with a pileup of 12%. The good energy resolution of this detector at rates up to 3 x 10$^5$ ions/s makes it an effective tool in the characterization of low-energy radioactive beams.
△ Less
Submitted 10 August, 2016;
originally announced August 2016.
-
Enhancement of fusion at near and sub-barrier energies for neutron-rich light nuclei
Authors:
Varinderjit Singh,
J. Vadas,
T. K. Steinbach,
B. B. Wiggins,
S. Hudan,
R. T. deSouza Zidu Lin,
C. J. Horowitz,
L. T. Baby,
S. A. Kuvin,
Vandana Tripathi,
I. Wiedenhover
Abstract:
Measurement of the fusion cross-section for neutron-rich light nuclei is crucial in ascertaining if fusion of these nuclei occurs in the outer crust of a neutron star. We have therefore measured the fusion excitation function at near-barrier energies for the 19O + 12C system and compared the experimental results with the fusion excitation function of 18O + 12C and 16O + 12C. In the experiment a be…
▽ More
Measurement of the fusion cross-section for neutron-rich light nuclei is crucial in ascertaining if fusion of these nuclei occurs in the outer crust of a neutron star. We have therefore measured the fusion excitation function at near-barrier energies for the 19O + 12C system and compared the experimental results with the fusion excitation function of 18O + 12C and 16O + 12C. In the experiment a beam of 19O, produced via the 18O(d,p) reaction, was incident on a 12C target at energies near the Coulomb barrier. Evaporation residues produced in fusion of 18,19O ions with 12C target nuclei were detected with good geometric efficiency and identified by measuring their energy and time-of-flight. A significant enhancement in the fusion probability of 19O ions with a 12C target as compared to 18O ions is observed. The significantly larger cross-sections observed at near barrier energies are not predicted by a static model of fusion for 19O + 12C indicating that dynamics play an important role in the fusion of neutron-rich light nuclei.
△ Less
Submitted 26 May, 2016;
originally announced May 2016.
-
Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector
Authors:
Davinder Siwal,
B. B. Wiggins,
R. T. deSouza
Abstract:
Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division ana…
▽ More
Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a position measured resolution of 170 $μ$m (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92 $μ$m (FWHM), corresponding to an intrinsic resolution of 64 $μ$m (FMHM) for a single Z-stack MCP detector.
△ Less
Submitted 8 September, 2015;
originally announced September 2015.